Transformer Diagnostic Testing. Performing Winding Resistance and Turns Ratio Tests

Similar documents
Current Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21,

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

WINDING RESISTANCE TESTING

A Guide to Transformer Winding Resistance Measurements

Table of Contents. TransformerIQ FAQs 1

Practical Transformers: Operation, Maintenance and Testing

Unit 33 Three-Phase Motors

Three-phase AC circuits

Introduction. Harmonics and IEEE 519 Page 1 of 19

T Substation Maintenance and Commissioning Test Equipment

Electrical Safety Tester Verification

On-line PD Monitoring Makes Good Business Sense

Electronics Technology

GE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry

GUIDE FOR TESTING POWER TRANSFORMERS

A Practical Guide to Dielectric Testing

Transformer circuit calculations

THE VALUE OF POWER FACTOR TESTING

COMPLIANCE WEST USA A Compliance Products USA, Inc. Company

TROUBLESHOOTING ABS DIAGNOSTIC CODES L20293, Rev. 1/13

ABB PSPS Erich Steinmann; Generator control-2013

Dielectric Withstand Testing in a Production Environment

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Voltage Regulator SPAU 341 C. Product Guide

High Voltage Power Supplies for Analytical Instrumentation

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

World Leader in HV Testing Technology

Electronics Technology

Owner s Manual & Safety Instructions

Exploring the Necessity of the Hot Hipot Test

Electrical Predictive and Preventative Maintenance

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Welcome to Linear Controls Quarterly Training

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

SURGE PROTECTIVE DEVICES

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Fundamentals of Power

ABR Brake Rectifier Instruction Manual

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Primary Test Manager (PTM) Testing and management software for primary assets

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

FRAX 150 Sweep Frequency Response Analyzer

employed to ensure the continuing reliability of critical systems.

CAPACITOR BANK TESTING SWP

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

User Guide. Model Insulation Tester / Megohmmeter

Current Transformers Ratio / Polarity / Types

VOLTAGE REGULATOR AND PARALLEL OPERATION

Transformer Design & Design Parameters

ELECTRONIC POWER SYSTEMS

Transformers. Special transformers Reactors products

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Product Information Sheet UH28CS-12kV Hi Pot Tester

EET272 Worksheet Week 9

Hydro Plant Risk Assessment Guide

TIG INVERTER INSTRUCTION MANUAL

Transformer Calculations

INSTALLATION & SERVICE MANUAL. Display Panel

MOTOR CONTROL IS OUR NATURE

Bourns Resistive Products

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

The full wave rectifier consists of two diodes and a resister as shown in Figure

TC-9102 Series Surface Mount Temperature Controllers

Tamura Closed Loop Hall Effect Current Sensors

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Understanding Arc Flash

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012


TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

Incipient Failure Detection in Power Transformers through Frequency Sweep Response

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

HIGH RELIABILITY POWER SUPPLY TESTING

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Table of Contents. Inductive Loop Vehicle Detector Applications

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

OMICRON Monitoring Solutions

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Typical Data Requirements Data Required for Power System Evaluation

Product Data Bulletin

CT Application Guide for the 489 Generator Management Relay

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

How To Understand The Electrical Power Supply Of A Power Supply System

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS

Video Surveillance UPS. Installation Guide

SX460. Generator Automatic Voltage Regulator Operation Manual

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Transcription:

Transformer Diagnostic Testing Performing Winding Resistance and Turns Ratio Tests Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 June 2016 Revision 1

REV 1 TRANSFORMER DIAGNOSTIC TESTING Power transformers play a vital role in power transmission. They are used to raise or lower the voltages in the power delivery system. High voltage (HV) power transformers are very expensive to manufacture and require long lead times since they are very labor intensive. A failed transformer is not only costly to replace but also causes loss of revenue to the utilities. Due to this reason, proper maintenance to ensure reliable performance and longevity is of utmost importance. In operation, all transformers are subjected to internal as well as external fault current. Transformers will see more external than internal fault. Fault current imposes high mechanical stresses on the transformer's windings and its mechanical structure. These high stresses weaken and alter the mechanical structure of the transformer. Hoop buckling of windings and winding deformations are typical effects of high stresses caused by a short circuit in the system. Also the heat generated during normal operation and during a fault, oxidizes the transformer oil. Over time, the interaction of the insulation paper (used for conductor wrapping) with the hot transformer oil weakens the dielectric strength of the transformer. In current operational environments, getting the required long outage to test transformers is not that common. So when the outage is planned, all the required tests need to be performed quickly. Although all tests need to be performed during the short outage time, personnel safety should never be overlooked or compromised. For transformer maintenance, personnel safety and speedy testing are the two most important factors. Several different tests can be performed on a transformer to analyze its condition. The transformer winding integrity can be verified by using the Sweep Frequency Response Analyzer test. The transformer bushing and overall insulation integrity can be analyzed using the Tan-delta (or Power Factor) test. Chemical analysis of the transformer oil should be conducted to detect moisture and determine the dielectric strength of the oil. Additionally, transformer turns ratio and winding resistance tests are used to detect shorted windings and possible connection issues. The focus of this application note is on winding resistance and turns ratio tests. Winding resistance tests can verify the winding connections to the transformer bushings, or the winding contact resistance (as in the case of the load tap changer and voltage regulator). A properly-designed winding resistance meter can obtain fast and accurate resistance readings when performing an HV transformer winding resistance test. A typical transformer winding resistance meter employs a high DC power supply (20Vdc to 60Vdc) to drive the winding into saturation. The use of a high DC voltage will quickly drive the winding into saturation and reduce the waiting time for stable readings. A high test current also delivers more accurate readings in noisy environments. Since the transformer winding is highly inductive, it will store the energy injected into it during testing. This energy must be safely discharged in a controlled way to avoid the risk of injury to test technician as well as damage to the test instrument. For operator safety, this discharge circuit should be built into a transformer winding resistance meter. The test equipment should also provide clear audio and visual warnings to the user. 1

TRANSFORMER DIAGNOSTIC TESTING REV 1 Vanguard Instruments offers the economical WRM-10, a 10A/36Vdc winding resistance meter that features dual resistance reading channels. The WRM-10 is capable of measuring winding resistance of transformers up to 200MVA. For higher test currents, Vanguard offers the TRM-20 (20A) and TRM-40 (40A). Both devices employ a 60Vdc voltage source that can quickly saturate very large HV transformer windings, providing fast and stable readings. Dual resistor reading channels can simultaneously read the HV and LV winding resistances (Figure 1). This feature further reduces the measuremen nt time by at least 50% Figure 1. Dual winding Connection Vanguard also offers three-phase winding resistance meters, the TRM 203 (20A) and TRM 403 (40A). The test terminals from these devices can connect to all the transformerr HV or LV bushings. The devicee will then inject the DC test current to each of the phases and measuree the resistance value. This feature reduces the testing time by making connections to the transformer only once (Figure 2) ). 2

REV 1 TRANSFORMER DIAGNOSTIC TESTING Figure 2. Three-phase Winding Connection Since a DC test current is passed through the transformer winding during the DC resistance test, the transformer core will be magnetized. When a magnetized-core HV transformer is energized the first time, the excessive in-rush current may trip the protection relays. Steps should be taken to eliminate this remnant magnetism. Both the TRM-20/400 and TRM-203/403 have built-in transformer demagnetization capabilities. This feature minimizes the remnant magnetism in the transformer core after a DC resistance test. For high voltage transformers with a load tap changer, it is a very desirable feature that the DC winding resistance meter also verify the continuity and correct operation of the load tap changers (LTC's). These are the only moving parts of a transformer, and like all mechanical devices, they are susceptible to wear and tear. In fact, LTC's result in more failures and outages than any other transformer component, so regular testing to ensuree reliable and safe operation is essential. The Vanguard LTCA-10 on the Load tap changer on the transformer. The test current used for LTCA - and LTCA-40 Load Tap Changer Analyzers offer dynamic resistance testing capability 10 and LTCA-40 are 10A and 40 A, respectively. A typical LTCA-10 test connection diagram is shown in figure 3. A DC test current is injected through the LTC contact. The LTC is then operated through alll taps while the Vanguard LTCA records the testt current and voltage drop across the LTC contact. The LTCA can produce a high resolution resistance waveform of the LTCA contact during operation as shown in figure 4. The user can observe the LTCA contact resistance reading/graph transitioning from one position to another. This is a powerful diagnostic tool for analyzing LTC and voltage regulator contact issues. 3

TRANSFORMER DIAGNOSTIC TESTING REV 1 Figure 3. Dynamic Resistance Test Connections Figure 4. Dynamic Resistance Waveform of a Voltage Regulator The IEEE C57.12.90 standard provides the guidelines for measuring transformerr turns ratios using the voltage method. Turns ratio tests verify the transformer winding configuration, winding turns ratio, and excitation current. A typical 3-phase turns ratio tester applies a single phase excitation testt voltage on the HV side of the transformer winding. The induced voltage on the corresponding phase is then measured on the secondary side. The turns ratio reading and excitation current is then displayed. Vanguard Instruments offers three 3-phase transformer turns ratio testers: ATRT-03 S2, TRF-100 and TRF-250. The TRF-250 provides the highest test voltage in the industry (250Vac). 4

REV 1 TRANSFORMER DIAGNOSTIC TESTING A built-in thermal printer conveniently prints the test reports on site for instantt analysis. All Vanguard Turns Ratio Testers can be used in stand-alone mode or can be PC-controlled with the providedd software. Figure 5. Thermal Printout from ATRT-03 S2 The ATRT-03 S2 and TRF-250 are also available as battery-operated models (ATRT-03A S2 and TRF-250A, respectively). This allows users to test transformers at a constructionn site when an AC supply is not available. Vanguard Instruments also offers single phase transformer turns ratio tester models ATRT-01 S3 (AC power) and ATRT-01B S3 (AC/Battery powered). Phase-shifting transformers are special transformers that require a 3-phase testt voltage for the turns ratio test. Vanguard Instruments offers the Tri-Phase turns ratio tester for this application. The Tri-Phase generates its own 3-phase test voltage (8Vac, 40Vac, 100Vac) to test the transformers. This device accurately measures the turns ratio and the phase shift relationship between the HV and LV of the transformer. Sample testt results are shown below in figure 6. 5 Figure 6. Typical Tri-Phase report showing the phase relationship

TRANSFORMER DIAGNOSTIC TESTING REV 1 To get the most out of the limited time available during a transformer outage, a user typically performs as many tests as possible. The Vanguard Trip Saver Box (TSB) provides a convenient way to perform winding resistance tests as well as turns ratio tests in one go. The TSB eliminates the need to change test cables between the winding resistance meter (heavy gauge conductors to carry current) and the lighter gauge cables of the Turns Ratio tester as shown in figure 7. The TSB allows the same TRM cables to be used with the turns ratio tester. Figure 7. Trip Saver Connections to TRM-403 and ATRT-03 S2 6

REV 1 TRANSFORMER DIAGNOSTIC TESTING The table below shows the Vanguard offerings for DC winding resistance measurement Model DC Test Current # Windings Tested Demag Routine TRM-20 Up to 20A Test two windings Yes TRM-40 Up to 40A Test two windings Yes TRM-203 Up to 20A Test three phases Yes TRM-403 Up to 40A Test three phases Yes WRM-10 Up to 10A Test two windings No LTCA-10 Up to 10A Test three phases + LTC diagnostics No LTCA-40 Up to 40A Test three phases + LTC diagnostics No The table below shows the Vanguard offerings for turns ratio testing Model Description Test Voltages Turns Ratio Range ATRT-01 S3 Single phase 4, 40V 0.8 15,000 to 1 ATRT-01B S3 Single phase, Battery Powered 4, 40V 0.8 15,000 to 1 ATRT-03 S2 3-phase 8, 40, 100V 0.8 15,000 to 1 ATRT-03A S2 3-phase, Battery Power 8, 40, 100V 0.8 15,000 to 1 TRF-100 3-phase 4, 40, 100V 0.8 50,000 to 1 TRF-250 3-phase 4, 40, 100, 250V 0.8 50,000 to 1 Tri-Phase True 3-phase 8, 40, 100V 0.8 15,000 to 1 Vanguard Instruments Winding Resistance Meters and Transformer Turns Ratio Testers are housed in field-rugged enclosures and feature rugged membrane keypads for convenient data entry and control. Optional built-in thermal printers are available for field use. All devices can be used in stand-alone mode or can be computer-controlled with the included software. For further information on Vanguard Instruments' offerings for current transformer testing, please contact our local channel partner or visit our web site at www.vanguardinstuments.com. 7

1520 S. Hellman Ave Ontario, CA 91761 USA Phone: 909-923-9390 Fax: 909-923-9391 www.vanguard-instruments.com Copyright 2016 by Vanguard Instruments Company, Inc. Transformer Diagnostic Testing Revision A June 23, 2016 JG, HN, TA