Comparison of various Wind Turbine Generators

Similar documents
Outline. Turbine Generators. Generator History 3/25/2014

WIND TURBINE TECHNOLOGY

Synchronous motor. Type. Non-excited motors

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

8 Speed control of Induction Machines

Motor Fundamentals. DC Motor

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current

AC Induction Motor Slip What It Is And How To Minimize It

Unit 33 Three-Phase Motors

SYNCHRONOUS MACHINES

LOSSELESS STARTING METHOD FOR THE WOUND ROTOR INDUCTION MOTOR

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Offshore Wind Farm Layouts

FREQUENCY CONTROLLED AC MOTOR DRIVE

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

13 ELECTRIC MOTORS Basic Relations

Principles of Adjustable Frequency Drives

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

Lecture 4 Energy Conversion in Wind Turbine

Analysis, Calculation and Reduction of Shaft Voltage in Induction Generators

WIND AS A RENEWABLE SOURCE OF ENERGY

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Lab 8: DC generators: shunt, series, and compounded.

Renewable Energy Laboratory for Engineering Students

Performance Analysis of Grid connected Wind Energy Conversion System with a DFIG during Fault Condition

GUJARAT TECHNOLOGICAL UNIVERSITY

ELECTRICAL ENGINEERING

Configuration study of large wind parks

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Lab 14: 3-phase alternator.

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Simulation of Power Control of a Wind Turbine Permanent Magnet Synchronous Generator System

PMG vs. DFIG the big generator technology debate

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Modeling and Simulation of a Large Chipper Drive

Control Strategies of the Doubly Fed Induction Machine for Wind Energy Generation Applications

THESIS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY. Modeling of Wind Turbines for Power System Studies

Analysis, Modeling and Control of Doubly-Fed Induction Generators for Wind Turbines

Understanding the Alternator

Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.

Power Quality Paper #3

Basics of Electricity

Motors and Generators

Induction Motor Theory

DIRECT CURRENT GENERATORS

Brochure. Generators for wind power Proven generators reliable power

Chapter 3 AUTOMATIC VOLTAGE CONTROL

Chen. Vibration Motor. Application note

Dynamic Models of Wind Turbines

WIND POWER IN INDIA: PROS AND CONS AN OVERVIEW

WIND POWER GENERATION TECHNOLOGY Mrs. N.V. Vader Mrs. V.A. Joshi

APPLICATION GUIDELINE FOR ELECTRIC MOTOR DRIVE EQUIPMENT FOR NATURAL GAS COMPRESSORS

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Power Conversion Controlling the Power of Energy

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

The Reliance on Wind Energy Depends on Advancements in Blade Pitch Control

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE

THIS paper reports some results of a research, which aims to investigate the

Selection of Generator for the Micro Hydro Power Plant

300 MW Variable Speed Drives for Pump-Storage Plant Application Goldisthal

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

Offshore Platform Powered With New Electrical Motor Drive System

Control Development and Modeling for Flexible DC Grids in Modelica

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

Institute of Energy Technology, 9 th Semester Report. Control of a variable speed variable pitch wind turbine with full scale power converter

Transformer Based Voltage Sag Generator to test Renewable Energy Systems during Grid Faults in the Laboratory

ELECTRODYNAMICS 05 AUGUST 2014

Inductance. Motors. Generators

Management of Low- and High-Frequency Power Components in Demand- Generation Fluctuations of a DFIG-Based Wind-Using Fuelcell

Reactive Power Generation by DFIG Based Wind Farms with AC Grid

ABB PSPS Erich Steinmann; Generator control-2013

Modeling Grid Connection for Solar and Wind Energy

HVDC Technology for Large Scale Offshore Wind Connections

Brochure. Electric generators to power the world

C Standard AC Motors

Application and Design of the ebooster from BorgWarner

Advance Electronic Load Controller for Micro Hydro Power Plant

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Distributed Generation and Power Quality Case Study

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

The stable way. Synchronous condenser solutions. siemens.com/energy/facts

ABB drives. Technical guide No. 4 Guide to variable speed drives

V kw The turbine that goes anywhere

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Solar Power Plant Design and Interconnection

Control of Motor Characteristics by Squirrel-Cage Rotor Design

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Modal Analysis of Weak Networks with the Integration of Wind Power

Application of a Large Hybrid Turbocharger for Marine Electric-power Generation

AC-Synchronous Generator

How To Improve A Variable Frequency Drive

Transcription:

Journal homepage: www.mjret.in ISSN:2348 6953 Anagha R. Tiwari Anuradha J. Shewale Comparison of various Wind Turbine Generators Anuja R. Gagangras Netra M. Lokhande Abstract This paper analyzes and compares various wind turbine generator connections and its control using various power electronic circuits. This paper deals with the current status of generator and power electronics in wind turbine concepts. It shows that doubly fed induction generator driving variable speed wind turbine controlled by back to back converter is most effective as compared to others. 1. INTRODUCTION Wind turbines produce electricity by using the power of the wind to drive an electrical generator. Wind passes over the blades, generating lift and exerting a turning force. The rotating blades turn a shaft inside the nacelle, which goes into a gearbox. The gearbox increases the rotational speed to that which is appropriate for the generator, which uses magnetic fields to convert the rotational energy into electrical energy. The power output goes to a transformer, which converts the electricity from the generator at around 700 to the appropriate voltage for the power collection system, typically 33 kv. Wind turbine is having 129 P a g e

two types. One is fixed speed wind turbine and another one is variable wind turbine. The most common type of wind turbine is the fixed-speed wind turbine with the induction generator directly connected to the grid. This system has a number of drawbacks, however. The reactive power and, therefore, the grid voltage level cannot be controlled. Most of the drawbacks of fixed wind turbine are avoided when variable-speed wind turbines are used. These turbines improve the dynamic behavior of the turbine and reduce the noise at low wind speeds. But in variable speed wind turbine power electronics converter is needed which makes the variable speed operation possible. Basically, a wind turbine can be equipped with any type of three-phase generator, such as synchronous generator and asynchronous generator. Out of these, doubly fed induction generator which is type of asynchronous generator is more preferable because of its several advantages. The DFIG technology allows extracting maximum energy from the wind for low wind speeds by optimizing the turbine speed, while minimizing mechanical stresses on the turbine during gusts of wind. The optimum turbine speed producing maximum mechanical energy for a given wind speed is proportional to the wind speed. Another advantage of the DFIG technology is the ability for power electronic converters to generate or absorb reactive power, thus eliminating the need for installing capacitor banks as in the case of squirrel-cage induction generator. Some researchers believe that the DFIG should be used only for the purpose for which it has been installed, i.e., supplying active power only. The paper describes the current status regarding generators and power electronics for wind turbine. 2. TYPES OF WIND TURBINES It is characteristic of fixed-speed wind turbines that they are equipped with an induction generator that is directly connected to the grid, with a soft-starter and a capacitor bank for reducing reactive power compensation. They are designed to achieve maximum efficiency at one particular wind speed. In order to increase power production, the generator of some fixed-speed wind turbines has two winding sets. The fixed-speed wind turbine has the advantage of being simple, robust and reliable and well-proven. And the cost of its electrical parts is low. Its disadvantages are an uncontrollable reactive power consumption, mechanical stress and limited power quality control. Owing to its fixed-speed operation, all fluctuations in the wind speed are further transmitted as fluctuations in the mechanical torque and then as fluctuations in the electrical power on the grid. Variable-speed wind turbines are designed to achieve maximum aerodynamic efficiency over a wide range of wind speeds. It has more complicated electrical system than that of a fixedspeed wind turbine. It is typically equipped with an induction or synchronous generator and connected to the grid through a power converter. The power converter controls the generator speed. The advantages of variable-speed wind turbines are an increased energy capture, improved power quality and reduced mechanical stress on the wind turbine. The disadvantages are losses in power electronics, the use of more components and the increased cost of equipment because of the power electronics. The introduction of variable-speed wind- 130 P a g e

turbine types increases the number of applicable generator types and also introduces several degrees of freedom in the combination of generator type and power converter type. 3. TYPES OF GENERATORS Basically, a wind turbine can be equipped with any type of three-phase generator. Today, the demand for grid-compatible electric current can be met by connecting frequency converters, even if the generator supplies alternating current (AC) of variable frequency or direct current (DC). Several generic types of generators may be used in wind turbines: Asynchronous (induction) generator: squirrel cage induction generator (SCIG) wound rotor induction generator (WRIG) o OptiSlip induction generator (OSIG) o Doubly-fed induction generator (DFIG) Synchronous generator: wound rotor generator (WRSG) permanent magnet generator (PMSG) 3.1 Synchronous generator Synchronous generator has two types: 3.1.1 Wound rotor generator Fig. (c) The stator windings of WRSGs are connected directly to the grid and hence the rotational speed is strictly fixed by the frequency of the supply grid. The rotor winding is excited with direct current using slip rings and brushes or with a brushless exciter with a rotating rectifier. Unlike the induction generator, the synchronous generator does not need any further reactive power compensation system. The rotor winding, through which direct current flows, generates the exciter field, which rotates with synchronous speed. The speed of the synchronous generator is determined by the frequency of the rotating field and by the number of pole pairs of the rotor. It has the advantage that it does not need a gearbox. But the price 131 P a g e

that has to be paid for such gearless design is a large and heavy generator and a full-scale power converter that has to handle the full power of the system. 3.1.2 Permanent magnet generator In the permanent magnet machine, the efficiency is higher than in the induction machine, as the excitation is provided without any energy supply. However, the materials used for producing permanent magnets are expensive, and they are difficult to work during manufacturing. Additionally, the use of PM excitation requires the use of a full scale power converter in order to adjust the voltage and frequency of generation to the voltage and the frequency of transmission, respectively. This is an added expense. However, the benefit is that power can be generated at any speed so as to fit the current conditions. The stator of PMSGs is wound, and the rotor is provided with a permanent magnet pole system. The synchronous nature of the PMSG may cause problems during startup, synchronization and voltage regulation. It does not readily provide a constant voltage. Another disadvantage of PMSGs is that the magnetic materials are sensitive to temperature. Therefore, the rotor temperature of a PMSG must be supervised and a cooling system is required 3.2. Asynchronous (induction) generator Asynchronous generator has two types: 3.2.1 Squirrel cage induction generator Fig. (a) As illustrated in Figure (a) the SCIG is directly grid coupled. The SCIG speed changes by only a few percent because of the generator slip caused by changes in wind speed. Therefore, this generator is used for constant-speed wind turbines. The generator and the wind turbine rotor are coupled through a gearbox. Wind turbines based on a SCIG are typically equipped with a soft-starter mechanism and an installation for reactive power compensation, as SCIGs consume reactive power. SCIGs have a steep torque speed characteristic and therefore fluctuations in wind power are transmitted directly to the grid. These transients are especially critical during the grid connection of the wind turbine, where the in-rush current can be up to 7 8 times the rated current. Therefore, the connection of the SCIG to the grid should be made 132 P a g e

gradually in order to limit the in-rush current. The major problem is because of the magnetizing current the full load power factor is relatively low. Too low a power factor is compensated by connecting capacitors in parallel to the generator. In the case of a fault, SCIGs without any reactive power compensation system can lead to voltage instability on the grid. The wind turbine rotor may speed up, for instance, when a fault occurs, owing to the imbalance between the electrical and mechanical torque. Thus, when the fault is cleared, SCIGs draw a large amount of reactive power from the grid, which leads to a further decrease in voltage. 3.2.2 Wound rotor induction generator Fig. (b) Wound rotor induction has two subtypes: 3.2.2.1 Optislip induction generator The Optislip feature allows generator to have a variable slip and to choose the optimum slip, resulting in smaller fluctuations in torque and power output. The variable slip is a very simple, reliable and cost-effective way to achieve load reductions. WRIG includes a variable external rotor resistance by means of which slip can be controlled. The converter is optically controlled, which means that no slip rings are necessary. The stator of the generator is connected directly to the grid. The advantages of this generator concept are a simple circuit topology, no need for slip rings and an improved operating speed range compared with the SCIG. To a certain extend, this concept can reduce the mechanical loads and power fluctuations caused gusts. However, it still requires a reactive power compensation system. The disadvantages include the speed range is typically limited to 0 10 %, poor control of active and reactive power is achieved and the slip power is dissipated in the variable resistance as losses. 3.2.2.2 Doubly fed induction generator The term doubly fed refers to the fact that the voltage on the stator is applied from the grid and the voltage on the rotor is induced by the power converter. This system allows a variablespeed operation over a large, but restricted, range. The converter compensates the difference 133 P a g e

between the mechanical and electrical frequency by injecting a rotor current with a variable frequency. Both during normal operation and faults the behaviour of the generator is thus governed by the power converter and its controllers. The power converter consists of two converters, the rotor-side converter and grid-side converter, which are controlled independently of each other. The rotor-side converter controls the active and reactive power by controlling the rotor current components, while the line-side converter controls the DClink voltage and ensures a converter operation at unity power factor. In both cases sub synchronous and over synchronous the stator feeds energy into the grid. The DFIG has several advantages. It has the ability to control reactive power and to decouple active and reactive power control by independently controlling the rotor excitation current. The DFIG has not necessarily to be magnetized from the power grid, it can be magnetized from the rotor circuit, too. It is also capable of generating reactive power that can be delivered to the stator by the grid-side converter. In the case of a weak grid, where the voltage may fluctuate, the DFIG may be ordered to produce or absorb an amount of reactive power to or from the grid, with the purpose of voltage control. The converter used in DFIG is back to back converter Fig. (d) the back-to-back converter is highly relevant to wind turbines today. The back-to-back converter is a bidirectional power converter consisting of two conventional pulse-width modulated converters. The DC link voltage is boosted to a level higher than the amplitude of the grid line-to-line voltage in order to achieve full control of the grid current. The capacitor between the inverter and rectifier makes it possible to decouple the control of the two inverters without affecting the other side of the converter. The power flow at the grid-side converter is controlled to keep the DC link voltage constant, and the control of the generatorside converter is set to suit the magnetization demand and the desired rotor speed.. it is concluded that the back to back converter is the ones recommended for further studies in different generator topologies. 4. CONCLUSION This paper provides a brief and comprehensive survey of the generator and power electronic concepts used by the modern wind turbine industry. A short introduction, presenting the basic 134 P a g e

wind turbine topologies and control strategies, was followed by the state of the art of wind turbines, from an electrical point of view. Old and new potentially promising concepts of generators and power electronics based on technical aspects and market trends were presented. It is obvious that the introduction of variable-speed options in wind turbines increases the number of applicable generator types and further introduces several degrees of freedom in the combination of generator type and power converter type. A very significant trend for wind turbines is that large wind farms will have to behave as integral parts of the electrical power system and develop power plant characteristics. Power electronic devices are promising technical solutions to provide wind power installations with power system control capabilities and to improve their effect on power system stability. ACKNOWLEDGEMENT We would like to articulate our deep gratitude to our Project Guide Prof. N.M. Lokhande, Head of Department who has always been source of motivation and firm support for carrying out the paper. We would also like to convey our sincerest gratitude and indebtedness to all other faculty members and staff of Department of,, Pune who bestowed their great effort and guidance at appropriate times without which it would have been very difficult on our paper work. REFERENCES [1]. Johan Morren, student IEEE and Sjoerd W.H. de Hann, member IEEE, Ridethrough of wind turbines with doubly fed induction generator during a voltage dip, IEEE transaction on energy conversion, vol. 20 No. 2 June 2005. [2]. Bijaya Pokharel, Master of science in electrical engineering, faculty of graduate school, Tennessee technological university, an abstract of thesis modeling, control and analysis of doubly fed induction generator based wind turbine system with voltage regulation. [3]. Anca D.Hansen, Generators and Power Electronics for wind turbines, Edited by Thomas Ackermann, Royal Institute of techonology, Stockholm, Sweden. [4]. www.wikipedia.com [5]. www.ieeeexplore.ieee.org 135 P a g e