Quick Notes. BioCapture : Acquiring EMG data

Similar documents
Exercise, the Electrocardiogram, and Peripheral Circulation

Technical Note Series

Electrocardiography I Laboratory

Laboratory Guide. Anatomy and Physiology

Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle

Bagnoli-2 EMG System. User s Guide

The Super 7 For Tennis Elbow

Fiber Optic Cable Installation

HOW TO USE THE LIFEPAK 1000 DEFIBRILLATOR 3

EEG Cap Instructions

Introduction. Basis and preliminary investigations

Electrocardiogram and Heart Sounds

Product Introduction MyoMuscle. Telemyo DTS-System. Telemetry system for EMG and Biomechanical Sensors.

Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

iworx Sample Lab Experiment HN-2: Stretch Receptors and Reflexes

Improving ECG Quality

A. FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT

R Series Quick Reference Guide

Muscle Physiology. Lab 5. Human Muscle Physiology

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Experiment MP-1: Electromyogram (EMG) Activity and Muscle Strength

Picture 1 Lead Color Code Lead Function V-Link Function V-Link Pin Table 2 Picture 2 Node Commander software

Throwers Ten Exercise Program

Wireless Internet Keyboard and Laser Mouse

Information for patients What is an EMG/Nerve Conduction Study?

Jabra BIZ User manual.

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Pre-operative Instructions for MIS Total Knee Stephen J Kelly, M.D.

Oxford University Hospitals. NHS Trust. Hand & Plastics Physiotherapy Department Flexor Tendon Repair. Information for patients

VENOUS BLOOD COLLECTION

HSG Engineering Tech Bulletin

Welch Allyn 1500 Patient Monitor Train the Trainer

Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K

Shoulders (free weights)

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

12/15-Lead ECG Protocol approved October 2005 revised October 2008

Prepared by: Paul Lee ON Semiconductor

Shoulder Extension Exercise Using Theraband

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Digital Photo Picture Frame. Operation Manual

Heavy / Light Workout Routine

HOSPITALITY RISK FACTORS & BEST PRACTICES - LAUNDRY

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

THROWER S TEN EXERCISE PROGRAM

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

CAR SEAT/ STROLLER INSTRUCTION MANUAL

Instructions for Use. Components of the GENOTROPIN PEN 12

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

Strength Training HEALTHY BONES, HEALTHY HEART

Strength Training for the Shoulder

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

SOUND ISOLATING EARPHONES. Português INSTRUCTION MANUAL. Pусский

MAINTENANCE & TROUBLESHOOTING

Fabric Replacement Top Installation Instructions

Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center

Wireless Optical Mouse

Reflex Response (Patellar Tendon) Using BIOPAC Reflex Hammer Transducer SS36L

Concept Design Of A Labview-MySQL Data Warehouse For Digital Recording of ECG-EMG

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Wireless Medical Telemetry Laboratory

Userʼs Manual. 7 Color LCD TV & Monitor V7000

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Single Lens Reflex (SLR) Camera

Tele Radio Panther SAFETY instructions

Getting Your Hand Moving After a Wrist Fracture

EXERCISE DESCRIPTIONS PHASE I Routine #1

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

SHOULDER EXERCISE ROUTINE

PART 1 - INTRODUCTION...

Basics of SURFACE ELECTROMYOGRAPHY

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

VP HDMI to VGA Converter

Ultra640 SCSI Measured Data from Cables & Backplanes

Self-Install Security System Installation and User Guide

Hand & Plastics Physiotherapy Department Carpal Tunnel Syndrome Information for patients

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

E500 Sound Isolating Earphones

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

SAMPLE WORKOUT Full Body

Control Box Wiring For PRSstandard Tool

ROTATOR CUFF TEARS SMALL

Home Care for Your Wound Drain

Operating Instructions

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

TM Advanced Tracking Technologies, Inc ATTI All rights reserved

Dash 18X / Dash 18 Data Acquisition Recorder

Lab 1: The Digital Oscilloscope

TENS and Electrodes Guide

Functional Firefighter Fitness

Hazardous Drugs Spill Kit

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

MIAMI POLICE DEPARTMENT

W850. Maintenance Guide

MZ Series Overview. Introduction. (MZ 220 Illustrated)

ELECTROCARDIOGRAPHY (I) THE GENESIS OF THE ELECTROCARDIOGRAM

Tektronix RSA306 USB Spectrum Analyzer

CamSplice Assembly Manual

PRODUCT SHEET OUT1 SPECIFICATIONS

Transcription:

BioCapture : Acquiring EMG data

Electromyography (EMG) is a recording used to examine the electrical activity of the muscles. More specifically, BioCapture uses surface electrodes for surface electromyography (semg) to monitor the general picture of superficial muscles that are close to the skin. This quick note will demonstrate a basic 1 channel EMG recording. Need to re-order supplies? Contact your local Sales Representative, call 1-855-GLNeuro (855-456-3876) or e-mail sales@glneurotech.com What you will need 3 cloth surface electrodes (P/N 040-0026, pkg of 30) / Healthcare Alcohol Prep 2Ply Large 5110 Alcohol wipes* Shielded lead electrode cable (optional, P/N 502-0189) Nuprep skin prep gel* LBS BioRadio User Unit Set up USB Bluetooth adapter (optional) 3 high performance foam snap electrodes (optional P/N 040-0038, pkg of 60) Free weight (optional) (i.e., a heavy book or bag or dumbbell) 3 button snap electrode cables (any color, P/N 116-0045-R, pkg of 5) *part of Disposable Supply Kit, P/N 602-0036-R Using an alcohol wipe and skin prep gel, prepare the surface of the skin where the electrodes will be placed by gently abrading and then wiping clean the area. Make sure the skin is dry before placing the electrodes. If sweating occurs, the cloth surface electrode contact will diminish and you may have to repeat this process in order to ensure sufficient skin/electrode contact. With arms relaxed, place two cloth surface electrodes approximately two to three inches apart on the left or right biceps muscle. See figure on the next page for details. Place a third cloth surface electrode right below the elbow of the same arm, ensuring the electrode is over a bony surface. This will be the ground electrode. 2

Connect any color button snap electrode cable to each cloth surface electrode. 1 channel EMG hook up Approx. 2-3 inches apart For the best EMG signal display during high levels of activity, use the shielded lead electrode cable and high performance foam electrodes in place of button snap electrode cables and cloth surface electrodes. Approx. 1 inch past the elbow Connecting electrode cables to BioRadio User Unit Connect the biceps muscle electrode cables to the black and red inputs of Ch1, on the BioRadio. It does not matter which input an electrode cable connects to. Connect the elbow ( Ground ) electrode cable to the GND input of the User Unit. To prevent motion artifact from encroaching EMG signal data, twist or bundle together any dangling cables, or tape any dangling cables to the skin with medical tape. SETUP QUESTIONS? CONTACT 1-855-GLNEURO OR VISIT WWW.GLNEUROTECH.COM/SUPPORT

Configuring your BioCapture system With BioCapture launched and your BioRadio turned on, connected and ready for use, press Device Config, from the tool bar to configure the BioRadio for one channel of EMG. Device Config From the Configure Device window, select Differential, enable Channel 1 ( Ch1 ), type in EMG for a custom name and the select EMG option under the Type drop down box. Ensure that all other inputs are disabled. For this demonstration, a 2 khz sampling rate is recommended. For further reading on Sampling Rate and Resolution, please refer to the BioCapture Owner s Manual. Press Program Device to program your BioRadio. Program Device Acquiring EMG data Your BioCapture system should now be ready to collect one channel of EMG data. Please note that the EMG configuration option presets the following display properties: y-axis max/min, custom filters, gain and offset. With arms at rest and relaxed, press Start Acquisition from the tool bar to begin acquiring data. A small data trace will appear. Start Acquisition This is the muscle activity at rest, also known as rest potential. 4

You may need to access the Y-Axis Set Max/Min option for a more prominent EMG signal display. The EMG hardware configuration option sets a display range of ± 25 mv. You can auto-scale all signals by pressing Ctrl + A or by selecting View > Auto-Scale Signals. Auto-Scale Signals Biceps exercises Bicep curls Simply squeezing, flexing or contracting your biceps muscles will produce a short series of bursts. Each burst is an action potential a rise and fall event of the muscle cell s membrane potential. In between flexes or as soon as you stop, the biceps muscles cells membrane potential will return to their rest potential, creating a small, electrically silent signal trace. Performing biceps curls arm at your side, bend your elbow and raise your hand to your shoulder with a heavy book, bag or a dumbbell genuinely demonstrates EMG activity of the biceps muscles. As a hand firmly grips the weight, the biceps muscle cells become electrically excited and their membrane potential begins to spike or fire, creating an action potential. As the weight is curled and brought back down, the biceps flex and extend, and the EMG signal data amplitude grows and attenuates. This coincides with the boisterous firing of the biceps numerous muscle cells. Biceps flex Firm grip Biceps flex Biceps extending The harder the biceps flexes, the greater the action potential, hence, the greater the EMG signal data s amplitude. A biceps curl s dynamic range of motion requires the biceps muscles to complement other muscle groups. 5

Ready. Set. Go! Your are now familiar with an essential EMG recording. For further reading on EMG, please refer to the BioCapture Owner s Manual and/or the following references: Guyton and Hall. Textbook of Medical Physiology, 9 th Edition, Saunders, Philadelphia, 1996. Kandel ER, Schwartz JH, Jessel, TM. Essentials of Neuroscience and Behavior. Appleton and Lange, Norwalk, Connecticut, 1998 By monitoring multiple muscle groups, dynamic exercises, like biceps curls, demonstrate activity of both biceps and wrist extensor muscles. HAVE QUESTIONS? NEED TECHNICAL SUPPORT? WE RE HERE TO HELP. Telephone: (216) 361-5410 or Toll-free 1-855-GLNeuro (1-855-456-3876) 9:00 a.m. - 5:00 p.m. EST, Monday Friday E-mail: support@glneurotech.com Web: http://www.glneurotech.com/support BioCapture is intended for scientific and research purposes only. IRB approval must be obtained before using this device in human testing. BioCapture is a trademark and BioRadio is a registered trademark of Great Lakes NeuroTechnologies Inc., Cleveland. OH. Acknowledgments: This work utilizes technologies supported by Small Business Innovation Research grants from the National Institutes of Health (NINDS, NHLBI, NIMH) and the Department of Defense. EC REP Emergo Europe Molenstraat 15 2513 BH, The Hague The Netherlands Tel: +31 (0) 70 345 8570 Fax: +31 (0) 70 346 7299 SETUP QUESTIONS? Great Lakes NeuroTechnologies 10055 Sweet Valley Drive VAlley View, OH 44125 USA Tel: 216-361-5410 Fax: 216-361-5420 DCO G131 G396-5015 Rev A Great Lakes NeuroTechnologies Inc. 2011 CONTACT 1-855-GLNEURO OR VISIT WWW.GLNEUROTECH.COM/SUPPORT