Common Sense Pathology

Similar documents
Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Validation of measurement procedures

Validation and Calibration. Definitions and Terminology

RE: Australian Safety and Quality Goals for Health Care: Consultation paper

WHAT IS DIABETES MELLITUS? CAUSES AND CONSEQUENCES. Living your life as normal as possible

How to Verify Performance Specifications

POCT in diagnosing and monitoring of Diabetes Mellitus. 13th EFLM Continuous Postgraduate Course, Sverre Sandberg, Noklus / EFLM


USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

BREAST CANCER PATHOLOGY

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Electronic Oral Health Risk Assessment Tools

Self-Monitoring Of Blood Glucose (SMBG)

blood glucose monitoring

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

ASSURING THE QUALITY OF TEST RESULTS

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

ALACC Frequently Asked Questions (FAQs)

Quality Assurance/Quality Control in Acid Deposition Monitoring

USE OF REFERENCE MATERIALS IN THE LABORATORY

Quality Requirements of a Point of Care Testing Service

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Scottish Diabetes Survey Scottish Diabetes Survey Monitoring Group

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

1.5 Function of analyte For albumin, see separate entry. The immunoglobulins are components of the humoral arm of the immune system.

American Association for Laboratory Accreditation

I HAVE JUST BEEN DIAGNOSED WITH TYPE 1 DIABETES

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Big Data: a new era for Statistics

Terms concerned with internal quality control procedures

To avoid potential inspection

Basic Lessons in Laboratory Quality Control

Homeostatic Model Assessment (HOMA)

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Ecology Quality Assurance Glossary

General Information. Our Background Automated Phone Services Holiday Coverage Licenses & Accreditations

This information explains the advice about type 2 diabetes in adults that is set out in NICE guideline NG28.

Australian Standard. Quality management systems Guidelines for configuration management AS ISO ISO 10007:2003 AS ISO 10007

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

Gravimetric determination of pipette errors

Obtaining insurance coverage for human growth hormone treatment for Idiopathic Short Stature In 2003, the Food and Drug Administration (FDA) approved

CLINICAL GUIDELINE FOR THE MANAGEMENT OF HYPERGLYCAEMIA IN ADULTS WITH ACUTE CORONARY SYNDROME

Diabetes Mellitus 1. Chapter 43. Diabetes Mellitus, Self-Assessment Questions

National Diabetes Audit and Report 1: Care Processes and Treatment Targets. Version 1.0 Published: 28 January 2016

1 Quality Assurance and Quality Control Project Plan

Six Sigma Metric Analysis for Analytical Testing Processes

APPENDIX N. Data Validation Using Data Descriptors

Checklist. Standard for Medical Laboratory

DECISION LIMITS FOR THE CONFIRMATORY QUANTIFICATION OF THRESHOLD SUBSTANCES

Screening for Prostate Cancer

Procedure for Equipment Calibration and Maintenance

Type 2 Diabetes: When to Initiate And Intensify Insulin Therapy. Julie Bate on behalf of: Dr John Wilson Endocrinologist Capital and Coast DHB

Scottish Diabetes Survey

SMF Awareness Seminar 2014

Diabetes and exercise

X-Plain Hypoglycemia Reference Summary

The LifeWave ALAVIDA Non-transdermal Antiaging Patch Improves Cellular Functional Status in Different Organs

You are a doctor at a busy general practice surgery in the city suburbs.

Effectiveness of an iphone application on Diabetes Self-Management

Clinical and cost-effectiveness of continuous subcutaneous insulin infusion therapy in diabetes.

calibrate confidence with Risk Management: The Critical Role of Measurement and Calibration WHITE PAPER SERVICES

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

Evaluation of Diagnostic and Screening Tests: Validity and Reliability. Sukon Kanchanaraksa, PhD Johns Hopkins University

Non-random/non-probability sampling designs in quantitative research

SIMULATION STUDIES IN STATISTICS WHAT IS A SIMULATION STUDY, AND WHY DO ONE? What is a (Monte Carlo) simulation study, and why do one?

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

The Family Library. Understanding Diabetes

Lab 2. Spectrophotometric Measurement of Glucose

Diabetic nephropathy is detected clinically by the presence of persistent microalbuminuria or proteinuria.

Understanding Diabetes

Centro de Salud México España Centro de Salud San Francisco Culhuacán Mexico City, Mexico

rtech laboratories began working toward ISO 9002:1994 in ISO 17025: Practical Benefits of Implementing a Quality System STATISTICAL ANALYSIS

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

THE ROYAL AUSTRALIAN AND NEW ZEALAND COLLEGE OF RADIOLOGISTS

Analytical Test Method Validation Report Template

Chapter 2 What Is Diabetes?

AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

The Facts on Equine Drug Testing

CHAPTER THREE COMMON DESCRIPTIVE STATISTICS COMMON DESCRIPTIVE STATISTICS / 13

Type 2 Diabetes. Tabinda Dugal GP Day 4/05/16

Class time required: Two 40-minute class periods + homework. Part 1 may be done as pre-lab homework

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Freiburg Study. The other 24 subjects had healthy markers closer to what would be considered ideal.

PROCEDURES FOR HANDLING OOS RESULTS

U.K. Familial Ovarian Cancer Screening Study (UK FOCSS) Phase 2 Patient Information Sheet

The Association of Vitamin D Dietary Intake and Type 2 Diabetes Among African Americans in Central Ohio

TUTORIAL on ICH E9 and Other Statistical Regulatory Guidance. Session 1: ICH E9 and E10. PSI Conference, May 2011

Statistical estimation using confidence intervals

Down s Syndrome Association Medical Series 5. DIABETES AND DOWN S SYNDROME. Notes for parents & carers

Means, standard deviations and. and standard errors

MENOPAUSE WOMAN'S TEST (Assessment of hormone balance)

Diabetic Ketoacidosis: When Sugar Isn t Sweet!!!

Diabetes Questionnaire

Standard Deviation Estimator

Trastuzumab (Herceptin ) for patients with metastatic breast cancer

G104 - Guide for Estimation of Measurement Uncertainty In Testing. December 2014

Published by the Labour Department

Why is Diabetes Important To Your Company?

Transcription:

Common Sense Pathology A REGULAR CASE-BASED SERIES ON PRACTICAL PATHOLOGY FOR GPs JULY 2015 Measurement Uncertainty A JOIN INITIATIVE OF The Royal College of Pathologists of Australasia

This issue of Common Sense Pathology is a joint initiative of Australian Doctor and the Royal College of Pathologists of Australasia. Published by Cirrus Media Tower 2, 475 Victoria Ave, Locked Bag 2999 Chatswood DC NSW 2067. Ph: (02) 8484 0888 Fax: (02) 8484 8000 E-mail: mail@australiandoctor.com.au Website: www.australiandoctor.com.au (Inc. in NSW) ACN 000 146 921 ABN 47 000 146 921 ISSN 1039-7116 2014 by the Royal College of Pathologists of Australasia www.rcpa.edu.au CEO Dr Debra Graves Email: debrag@rcpa.edu.au While the views expressed are those of the authors, modified by expert reviewers, they are not necessarily held by the College. Common Sense Pathology Editor: Dr Steve Flecknoe-Brown Email: sflecknoebrown@gmail.com Australian Doctor Education Director: Dr Amy Kavka Email: amy.kavka@cirrusmedia.com.au Reviewer: Dr Amanda McBride Email: amanda.mcbride@cirrusmedia.com.au Chief Content Producer: Cheree Corbin Email: cheree.corbin@cirrusmedia.com.au Graphic designer: Edison Bartolome Email: edison.bartolome@cirrusmedia.com.au Production co-ordinator: Eve Allen Email: eve.allen@cirrusmedia.com.au For an electronic version of this and previous articles, you can visit www.australiandoctor.com.au or download an ebook version from www.australiandoctor.com. au/ebooks You can also visit the Royal College of Pathologists of Australasia s web site at www.rcpa.edu.au Click on Library and Publications, then Common Sense Pathology. This publication is supported by financial assistance from the Australian Federal Department of Health. 2 AUTHORS Associate Professor Tony Badrick RCPA Quality Assurance Programs, Sydney, NSW. Associate Professor Peter Stewart Sydney South West Pathology Service, Royal Prince Alfred Hospital, Sydney, NSW. Understanding measurement uncertainty ANY measurement has some error associated with the process itself. For example, measuring weight is affected by the accuracy of the scales, what the patient is wearing, if the patient moves and the parallax error of the scale reader. Understanding this measurement uncertainty assists in interpreting this result, and understanding if there is a real difference between this and a future result. Technically, uncertainty means doubt about accuracy of a measurement. The commonly used term used to describe this concept is measurement uncertainty (MU) and characterises the dispersion of results about a single measurement. Medical pathology laboratories are required as part of their accreditation to determine or estimate the MU for all quantitative results.

Medical pathology laboratories are required to determine or estimate the measurement uncertainty for all quantitative results. Estimating MU in a laboratory environment is a fourstep process involving the following: 1. Define what will be measured. 2. Identify all sources of uncertainty. 3. Quantify the uncertainties of each of these sources. 4. Calculate the combined uncertainty. The measurement of HbA 1c is an important marker for diagnosis and control of diabetes. An ideal primary goal of diabetes therapy is an HbA 1c level of less than 6.5% (48mmol/mol), although this does vary depending on the individual patient s treatment plan. The non-diabetic reference range is generally accepted as 4.0-6.0% (20mmol/mol-42mmol/mol). Note HbA 1c results must only apply to assay methods that are traceable to the Diabetes Control and Complications Trial reference procedure, to ensure that the conclusions of the study and decision points are applicable for interpreting patient HbA 1c values. To provide a clear analytical distinction between the recommended HbA 1c concentrations, an analytical (method) uncertainty expressed statistically as a coefficient of variation (CV) of less than 3% is required. Methods that produce analytical CVs of 4.0% or greater are not considered fit for purpose, as this degree of analytical imprecision cannot distinguish changes in the HbA 1c level of 1%, that is, cannot distinguish a HbA 1c level of 7.0% (53mmol/mol) from 8.0% (64mmol/mol). When the analytical CV (uncertainty of measurement) is applied to the actual measured HbA 1c value, the possible range of HbA 1c values applicable to this measurement can be determined. (It is usual practice to calculate the 95% confidence interval for pathology measurements, calculated as 1.96 standard deviations or 1.96 coefficients of variation about the measured value.) For example, if the analytical CV is 3%, a measured HbA 1c can only be regarded as falling within a range of values defined by ± twice the CV; in this example it is ± 6% of the measured value. Examples for a nominal analytical CV of 3% at various measured HbA 1c levels are shown in the table on the next page. 3

ANALYTICAL CV of 3% for HBA1C MEASUREMENTS Measured HbA1C% (mmol/mol) Uncertainty of measurement range for an analytical CV of 3% 5.0 (31) 4.7 5.3 (28-34) 6.0 (42) 5.6 6.4 (38-46) 6.5 (48) 6.1 6.9 (43-52) 7.0 (53) 6.6 7.4 (49-57) 7.5 (58) 7.1 8.0 (54-64) 8.0 (64) 7.5 8.5 (58-69) 8.5 (69) 8.0 9.0 (64-75) 9.0 (75) 8.5 9.5 (69-80) 10.0 (86) 9.4 10.6 (79-92) CASE study Mrs A is 48 and had diabetes diagnosed four years previously and is on oral hypoglycaemic treatment. Her GP monitors control with three-monthly HbA 1c measurements. Three previous readings are 6.6, 7and 7.4 % (49, 53 and 57mmol/mol). Question: The GP is concerned that her control is deteriorating. Is that correct? Answer: Not necessarily. All these results are within the same MU, and cannot be distinguished from each other. Sources of variation in results Sources of uncertainty in laboratory measurements include: Non-representative sampling. Environmental effects on the measurement process (for example, heat and light). Personal reading errors. Finite instrument resolution of discrimination thresholds. Inexact values of measurement standards. Approximations incorporated into the measurement. Variations in reported observations under apparently identical conditions. All together these different effects can be classified as either imprecision, bias, calibration or others. A number of these sources of uncertainty are difficult to quantify. The laboratory will limit the uncertainty calculation to the analytical process. The GP needs to call the pathology laboratory to ascertain the most correct levels, or variability status, so that the GP can understand the patient s situation. For any test, there are a number of causes of variation. If we take glucose as an example, there are various disease states that will elevate glucose concentrations, including diabetes mellitus caused by deficient or ineffective insulin; or decrease glucose concentrations, such as excessive insulin levels in insulinoma. Other endocrine disease will also increase glucose levels 4

The GP needs to call the pathology laboratory to ascertain the most correct levels, or variability status, so that the GP can understand the patient s situation. because of the antagonistic effects of some hormones on insulin action. However, there are many other non-pathological factors that affect glucose levels, leading to apparent elevations or decreases in glucose levels. These are grouped into biological variation, pre-analytical or analytical variation. This non-pathological variation can be characterised for all tests, and allows an understanding of the causes of variation and possible means of minimising the source, and hence better interpretation by the clinician. Biological variation is due to normal physiological rhythms such as: Daily patterns of sleep and wake. Food and water intake and exercise. Monthly hormonal changes in the menstrual cycle, during menopause or in pregnancy. Seasonal variations (eg, temperature and sunlight). The effects of the ageing process. Biological variation is different from the concept of a normal or reference interval. There is a normal biological variation of an individual as well as the biological variation of a population at a particular season and place. Pre-analytical variation in test results is related to the preparation of the patient and the treatment of the sample. The test result depends on the time the sample is taken, how it is taken and how the sample is preserved. For serum glucose levels to reflect the normal state of the patient, the sample must be a fasting sample, taken without any collection problems, and any cellular impacts on the sample glucose levels must 5

be controlled. It should be a freely flowing sample (without stasis, not from an arm with a drip, and not from sample contaminated by tissue fluid as can happen with a finger prick), collected into the correct container with the appropriate preservative, and transported promptly to the laboratory. Analytical sources of error are those where the assay is not calibrated correctly, or where there are random sources of error because of reagent deterioration or poor instrument maintenance. The total physiological variation is the sum of the individual, population and analytical variation. Calculating measurement uncertainty Laboratories routinely determine if an analysis has been acceptable by comparing the results of known quality control (QC) samples against predetermined values. These QC samples are purchased in large volumes, often sufficient for the laboratory for two or more years. Thus laboratories quickly accumulate a lot of data on replicate samples for every assay they perform. These data are the basis for determining MU and is expressed as the standard deviation or coefficient of variation. These QC sample concentrations are ideally chosen to reflect critical clinical decision points for the assays (eg, HbA 1c close to 6.5% [48mmol/mol]). Uses of measurement uncertainty The main clinical applications of MU are listed below: 1. Appropriateness for use Tests are used to identify diseases where the test result is above or below normal levels. For a test to be able to discriminate between healthy state and disease state, the assay must be able to measure concentrations within the normal range. As every measurement has an MU associated with it, the MU must be less than the normal range if the test is to be able to measure differences from the normal. To measure changes within the normal range, the MU must be less that the biological variation, ideally less than a quarter of that. Laboratories are required by the accreditation authority to have determined the MU for each quantitative assay and to assess the appropriateness for use of those assays. All assays used routinely are fit for this purpose. With some tests, the analytical variation is high compared with the biological variation; hence great care is needed to ensure the assay does indeed discriminate between normal and pathological levels. 2. Diagnosis Pathology test results can be interpreted in three ways: against a reference interval (the proper term for normal range ), against a decision level or against previous results. Some tests are interpreted against a decision level, such as glucose in a glucose tolerance test, cholesterol levels and HbA 1c measurements. In the case of HbA 1c, a level of 48mmol/mol(6.5%) is a critical clinical 6

A decision level needs to be cautiously interpreted with the knowledge that the cut off has an associated measurement error. decision level in terms of diabetes diagnosis. But as discussed above, the MU of HbA 1c at the level of 48mmol/mol is +/- 4mmol/mol. Therefore a decision level needs to be cautiously interpreted with the knowledge that the cut off has an associated measurement error. For this reason, it is good practice to repeat these measurements at a different time before a diagnosis is made and management is changed. Monitoring a patient involves comparing a test result against a previous result to determine if treatment or compliance is successful. To be sure that two results used to monitor the patient are different requires an understanding of biological variation and MU. For example, HbA 1c results that differ by less than the MU are not different, so consecutive results of 47, 49 and 51mmol/mol are all the same within the error of the method. 3. Quality control in the laboratory MU is used when assessing the quality control rules and rigor required keeping an assay performance acceptable. An assay that has a high MU requires more vigilance than one with low variation. CASE studies Mr P is a 56-year-old man who has been having serum PSA measurements annually by his GP. Mr P has a PSA result of 4.2µg/L; 12 months ago, the result by the same laboratory and measurement procedure was 3.8µg/L. (Reference Range <3.8ug/L in the laboratory) Question: Considering only the measurement uncertainty, has the PSA increased? 7

Answer: When the laboratory was asked, they provided the MU for PSA at a concentration of 2.9µg/L to be 0.15µg/L (uncertainty = 5.0%). The PSA has increased from 3.8 to 4.2. This is 0.4/3.8 x 100 = 10.5% So, is the PSA increase greater than the laboratory would expect from the measurement imprecision? Laboratories can calculate what an expected difference in two results measured at different times should be, based only on the MU of the method. This is achieved using a statistical formula expressed as 2.77 x SD of the method. For the above example: 2.77 x 5.0% = 14%, namely the two results should differ by >14% (>0.53µg/L) for there to be 95% confidence that they are in fact different. In this case, the laboratory has used its MU data in several ways to assist the referring practitioner with an interpretative comment, Taking account of measurement variability, this result is not significantly different at a confidence level of 95%. Question: Is the latest PSA value significantly above the age-related clinical decision value of 4.0µg/L? Answer: The clinical decision value of 4.0µg/L does not have a known uncertainty associated with it. The MU of the result of 5.0% = 0.21µg/L at a level of 4.2µg/L. The lab can assist with calculating the confidence interval for the patient result, which was found to be +/- 0.4µg/L. Thus the 95% confidence interval for the latest result = 3.8-4.4µg/L. So the result is not significantly different to 4.0 µg/l. These examples demonstrate the importance of understanding the information that MU can provide to assist clinical decisions. Advice on the interpretation of results can always be sought from the providing laboratory. In particular, the laboratory would be able to help with any calculations for statistical validation and always welcomes such enquiries. References Clinical Biochemist Review 2004; 25(4):S1 S24. 8