Design and Analysis of Regenerative Air Cooler

Similar documents
Chapter 3.4: HVAC & Refrigeration System

Because here you can see a simple an elementary direct evaporative cooling system this is called as a single stage system you can see from the

Waste Heat Recovery through Air Conditioning System

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Automobile Air Conditioning Primer

Performance Test of Solar Assisted Solid Desiccant Dryer

Research on the Air Conditioning Water Heater System

How Ground/Water Source Heat Pumps Work

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Refrigeration Basics 101. By: Eric Nelson

AIR CONDITIONING TECHNOLOGY

The Development of a Frost-Less Heat Pump

Evaporative Cooling for Residential and Light-Commercial

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Glossary of Heating, Ventilation and Air Conditioning Terms

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

New Trends in the Field of Automobile Air Conditioning

How do I measure the amount of water vapor in the air?

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Thermal efficiency characteristics of indirect evaporative cooling systems

Evaporative Cooling System for Aquacultural Production 1

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

UNIT 2 REFRIGERATION CYCLE

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

Wet Bulb Temperature and Its Impact on Building Performance

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Creating Efficient HVAC Systems

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

How To Calculate The Performance Of A Refrigerator And Heat Pump

AIR REVERSING R744 AIR CONDITIONING SYSTEM

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

ThermoStar Refrigeration Air Dryers

Characteristics of Evaporators

ThermoSorb Desiccant Dryers

Air Conditioning 101. STN Presentation AC101

Drives and motors. A guide to using variable-speed drives and motors in retail environments

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Mohan Chandrasekharan #1

Chapter 14. At temperatures below the critical temperature, the gas GAS VAPOR MIXTURES AND AIR-CONDITIONING. Objectives

Solar Desiccant Air Conditioner

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Contents and Nomenclature

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Experimental Evaluation Of The Frost Formation

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Product Data Bulletin

A Cover HVAC ENERGY EFFICIENT

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

The Second Law of Thermodynamics

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

SOLAR-POWERED COOLING, DEHUMIDIFICATION AND AIR CONDITIONING

HVAC Systems: Overview

Why and How we Use Capacity Control

A Demonstration Plant of a Liquid Desiccant Air Conditioning Unit for Drying Applications

Model-Based Approach for Optimizing a Data Center Centralized Cooling System

Refrigeration Air Dryers. Catalogue

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

The Second Law of Thermodynamics

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

imagine SOLAR AIR CONDITIONING MADE EASY

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Refrigerated Air Dryers. Catalogue

Analysis of data centre cooling energy efficiency

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Thermodynamics - Example Problems Problems and Solutions

HEATER, AIR CONDITIONING AND VENTILATION

Air-Conditioning Buying Guide

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Energy Efficiency. Energy Efficient Home Cooling:

Experimental Study on Super-heated Steam Drying of Lignite

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

How To Know If A Refrigeration System Is Efficient

Transcription:

Design and Analysis of Regenerative Air Cooler Mr. S.N Tripathy 1, Vicky Verma 2, Abhishek Kumar 3, Sidharth kumar 4 Associate Professor 1, student 2, 3, 4, Dept. Of Mechanical Engineering, GIET, Gunupur, Odisha, India Email: kumarabhishek0047@gmail.com,vickyverma992@gmail.com Abstract- Regenerative air cooler is a device which is capable of controlling humidity as well as temperature within a confined area. The main motive is to restrict the amount of water droplets mixing with the output air, which is the main reason of moisture generation. So by this project we are performing the same task to our best. Although a lot of modification is required to launch this device uniformly but then also we have done our best job to present it as a model.we have used blower, a motor, a water pad, a pump, a water tank and a heat exchanger in this cooler.1 blower is used to throw the air outside and another is used to suck the air and send it at heat exchanger. A motor is used to rotate the blowers. A water pad is being used to cool the air air Furthermore a tank is for storage and a pump is for transmission of water. Regenerative air cooler is a suck the air and send it at heat exchanger. A motor is used to rotate the blowers. A water pad is being used to cool device which is capable of controlling humidity as well as temperature within a confined area. Index Terms- Heat Exchanger, water tank, motor, water pad, pump, blower. 1 INTRODUCTION This project involve making a regenerative air cooler that would enable the user to control temperature as well as humidity of the incoming air.this imparts properties similar to that of an AC, except that this device is based on the evaporative cooling principle of desert cooler. This entails less cost of the device. The principle objective is to make the performance of this device as possible to that of an air conditioner. The device employs the normal components used in desert cooler such as pump, water pads, water basin in addition to heat exchanger and blower. The blower used in this model provides the draught of cool air into the room with the inlet air undergoing cooling blows a part of this cool air into the heat exchanger. The cooling air being passed into the heat exchanger flows through a water pad, since for this air temperature reduction is the only concern. This air will be thrown into the atmosphere after providing cooling action in heat exchanger. This removes the concern of controlling humidity in this stream of air. The cooling action of the heat exchanger keeps the specific humidity of the incoming air constant. This cooling is helpful in reducing the moisture content of the final exiting air because cool air absorbs comparatively lesser moisture. Since the cooing in the heat exchanger is directly dependent on the temp of the cooling fluid (air), the moisture content of the final air can be controlled to some extent by greater cooling in the heat exchanger phase. Hence the temp control and moisture control are interlinked with one another. This is the drawback of this device with respect to an air conditioner. There are several places of application for regenerative air cooler. Indian industries are often unable to provide their workers with proper work environment during summers because of the prohibitive expense incurred in getting their work units air-conditioned. Traditional desert coolers do not quite solve the purpose of cooling a big hall size work place. Regenerative air cooler is an affordable and effective solution to this problem. It uses a blower in place of the fan of desert cooler and hence its electricity consumption is not too larger than that of a cooler. The performance of regenerative air cooler is much superior to that of a desert cooler, as will be confirmed by the design calculations and demonstrated. There are prospects of improving the efficiency of regenerative air cooler still further by improving the design of heat exchanger. Most of these modifications can be implemented in a cost effective manner, without resorting to the costly alternative of using a costly copper heat exchanger. 2 LITERATURE RIVIEW 2.1 A General Theory of Wet Surface Heat Exchangers and its Application to Regenerative Evaporative Coolinig I.L Maclaine-cross [1],suggested that wet surface heat exchangers such as cooling towers and wet plate heat exchangers are important in air conditioning. A linear approximate model of wet surface heat exchangers is proposed. The equations of the model are rearranged, enabling solutions for wet bulb depression and wet bulb temperature to be obtained independently, by 229

analogy from published solutions for dry bulb temperature in dry surface heat exchangers. Performance predictions by this method for a cross flow cooling tower are found to agree with those from a prevous finite difference solution. Published performance measurements for a crossflow wet plate heat exchanger are lower than predicted by the method possibly due to poor wetting or excessive water flow. Excellent performance is predicted for a proposed regenerative evaporative cooler using such an exchanger. 2.2 Experimental study of a counter flow regenerative evaporative cooler with finned channels Dae-Young Lee [2],suggested that a regenerative evaporative cooler has been fabricated and tested for the performance evaluation. The regenerative evaporative cooler is a kind of the indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counter flow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied tothe internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporative water flow rate. To improve the cooling performance, the evaporative water flow rate needs to be minimized as far as the even distribution of the evaporative water is secured. At the inlet condition of 32 C and 50% RH, the outlet temperature was measured at 22 C which is well below the inlet wet-bulb temperature of 23.7 C. trapped oil, carbon particles, and condensed liquid water and removes the moisture from the desiccant. 2.4 Desiccant cooling air conditioning R.Z Wang [4],suggested that the principles underlying the operation of desiccant cooling systems are recalled and their actual technological applications are discussed. Through a literature review, the feasibility of the desiccant cooling in different climates is proven and the advantages it can offer in terms energy and cost savings are underscored. Some commented examples are presented to illustrate how the desiccant cooling can be a perfective supplement to other cooling systems such as traditional vapour compression air conditioning system, the evaporative cooling, and the chilled-ceiling radiant cooling. It is notably shown that the desiccant materials, when associated with evaporative cooling or chilled-ceiling radiant cooling, can render them applicable under a diversity of climatic conditions. 2.5 Modelling of indirect evaporative air coolers P.J Erens and A.A Dreyer [5],suggested that the modelling of indirect evaporative air coolers is discussed and three calculation models are described. Sample calculations show that the optimum shape of the cooler unit would result in a primary to secondary air velocity ratio of about 1.4, assuming that the primary and the secondary air mass flow rates are the same and that the same plate spacings are used on the primary and secondary sides. In conclusion it is found that the simplified model gives good results and is recommended for the evaluation of smaller systems and for initial design purposes while the more sophisticated methods should be used for more accurate performance prediction. 3 WORKING PRINCIPLE: 3.1 Principle Working of Regenerative Air Cooler The working of regenerative air cooler can be understood through the following diagram depicting the flow of air within the device 2.3 Flow reversing regenerative air dryer Arthur R.Grix [3],suggested that a flow-reversing, regenerative, desiccant air dryer system absorbs moisture, oil droplets, and carbon particles from the incoming air during compression in a compressed air system. Once sufficient air pressure has been attained in an air pressure reservoir, control valves direct the flow of atmospheric-pressure air, heated by passing through the warm compressor cylinder, in a reverse direction through the air dryer. The reverse flow of heated, atmospheric pressure air both purges the 230

4. EQUATIONS AND CALCULATION: 4.1 Calculation for Blower Ambient air Cooled air Entering Air velocity, in=6.62 m/sec Inlet area, Ain=П/4(.24^2) Eq(1) Ain=.045 m 2 Q=Ain vin...eq(2) = 0.297 m 3 /sec. = 17.874 m 3 /min. by applying bernaulli s equation NAMING 1 Air Blower 2 Cooling Pad 3 Water Distributer 4 Water collecting tank 5 Heat Exchanger 6 Circulating pump for Direct cooling 7 Circulating pump for heat exchanger 3.2 Air Circulation Process The ambient air is pulled into the cooler due to the suction effect creating by rotating blower. The incoming air first flow through the heat exchanger where it undergoes first stage of cooling. Then it flows through the wetted water pad, undergoing evaporative cooling in the process. A portion of this evaporative cooled air flows out of the cooler, while the blower blows the remaining portion to the atmosphere. This causes the air to loose its kinetic energy and acquires greater static pressure. This air then flows across water pad for a second time undergoing further evaporative cooling. It then flows through the heat exchanger and exchange heat with the atmospheric air. The temperature of the ambient air decrease and flows across the water pad, undergoing evaporative cooling in this process then blower blow into the room with controlled relative humidity.the higher pressure of this air sustains the forward motion of this air through the heat exchanger. This stream acts as the cooling stream in the heat exchanger, cooling the incoming stream of air. After cooling, this stream gets heated and is rejected into the atmosphere. Q=CONST Q=.297 m 3 /sec=17.874 m 3 /min Outlet area, Aout= П/4(.32^2)=.0803 m2 Eq(3) Exit air velocity (air to room), Vout=Q/A=.297/.0803= 3.72 m/sec.eq(4) 4.2 Calculation for Water Pad DBT1=38 C WBT1=21 C RH1=20% H1=60.25 KJ/Kg of air Spe. Vol, Vs1=.89 m 3 /Kg DBT2=36.5 C WBT2=27 C RH2=50% H2=85 KJ/Kg of air SPE. VOL, Vs2=.91 m 3 /Kg Mass of Air Supplied m a =Q/Vs = 17.874/.91 = 19.64 Kg/min Ma=.327 Kg/sec...Eq(5) 4.3 Calculation for Heat Exchanger T H1 =38 C T H2 =? T C1 =36.5 C T C2 =? Capacity rate of air, (C) min=m a..eq(6) U =..Eq(7) H=40, l=.0005, K for Al =205 U= 1/(2/40)+(.0005/205) = 39.996 A= 6 2 Пrh =.0603 UA=39.996.0603=2.411 231

=10.05 5.1.2 R.H.S VIEW.Eq(8) 10.0 10.0 10.05 ε=.526 T H1 =38 C T H2 =? T C1 =36.5 C T C2 =? ε =..Eq(9) (38-36.5) ε =38- T H2 (38-36.5) ε =38- T H2 1.5.526= 38- T H2 0.789 = 38- T H2 T H2 =37.211 C 0.789 = T C2-36.5 T C2 =37.289 C Temp. Of atm air, TH1=38 C Temp. Of treated atm air, TH2=37.211 C Temp. Of cooled air from water pad, TC1=36.5 C Temp. Of exit air, T C2 =37.289 C 5.1.3 L.H.S VIEW 5. FIGURES, TABLES AND PHOTOGRAPHS: 5.1 Design of Regenerative air cooler using catia software 5.1.1 TOP VIEW 1. Outgoing air from Blower 5. Pump for Heat Exchanger 2. Blower 6. Water Tank 3. Heat Exchanger 7. Water Pad 4. Pump For Direct Cooling 5.2 Tabulation 5.2.1 Final results of this experiment is as follow:- 232

5.2.2The range of the results of this experiment is as follows:- 0.428 66.71 80.25 23.81 Temperatur e (C) Humidity (RH %) Ambient air 36-40 20-25 Exit air 33-37 50-60 Photo of Regenerative Air Cooler:- Temperature (C) Ambient air 38 20 Exit air(air to room) 36.5 50 Humidity (RH %) 5.3 0.51 68.40 84.52 26.38 6.2 variation of COP with mass flow rate Air flow rate(kg/sec.) COP of direct evaporative cooler COP of regenerative air cooler % increase in COP 0.327 4.62 5.96 20.44 0.428 7.76 9.85 23.81 0.51 9.21 12.37 26.38 6.3 Graphs:- 6. RESULTS AND GRAPHS:- 6.1 Variation of effeciecy with mass flow rate Graph no. 1: Variation of efficiency with Air Flow Rate. Air flow rate(kg/sec.) Efficiency of direct evaporative cooler(in %) Efficiency of regenerative air cooler(in %) % increase in efficiency 0.327 60.42 75.72 20.44 233

Graph no. 2: Variation of COP with Air flow rate 7. CONCLUSION It may be concluded that there is considerable improvement inefficiency and COP (20-27 %) of direct evaporative cooler with regenerative heat exchanger. Percentage increase in efficiency is almost same for each flow rates. The cost comparison shows that there is slight increase in cost because of an additional pump and a heat exchanger but increase in cooling efficiency is substantial. Thus regenerative evaporative cooler is advantageous for providing more cooling compared to an ordinary direct evaporative cooler, which can make the cooler more useful for providing thermal comfort in residential and commercial buildings. It may also attract more people for maximum utilization of such a low energy consuming device leading to energy conservation. REFERENCES: [1] I.L Maclaine-Cross and P.Barks A general Theory of Wet Surface Heat Exchanger and its Application to Regenerative Evaporative cooling journal of Heat Exchanger,vol 103,pp 579-585,1981. [2] Dae-Young Lee Experimental Study of a counter flow regenerative evaporative cooler with finned channels journal of Heat and Mass transfer,vol 65,pp,173-179,2013. [3] Arthur R.Grix Flow reversing regenerative dir dryer journal of regenerative dryer,vol 23,pp 189-196,2006. [4] R.Z Wang Deciccant cooling air conditioning Energy,vol 104,pp,778-791,2012. [5] P.J Erens and A.A Dreyer Modelling of indirect evaporative air cooler journal of evaporative air cooler,vol 52,pp,179-187. 234