WATERPROOFING OF BALCONIES AND TERRACES

Similar documents
Wecryl Waterproofing System under surfacing supplied by others

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

WATERPROOFING OF WET ROOMS

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

BLACK JACK ALL WEATHER ROOF COATING

BENTLEY ELEMENTS COLLECTION LVT

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

What Causes Foundation Leaking?

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

SECTION POLISHED CONCRETE FINISHING

G4 is browny translucent in colour and is effected by UV light. Therefore it is for internal use unless top coated to protect it from UV light

T R A N S F E R A B L E F U L LY

Division 9. SignaFlor Pad and Pour Flooring System

Waterproofing construction Joints

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

WOOD FLOORING ADHESIVES

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

PRODUCT DESCRIPTION 29/08/2014

Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors

White rust on galvanized and galvanized pre-painted steel. Technical Information

Ron Miedema Cement Contractor 1865 Pine Ridge ~ Jenison, MI 49428

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Tecnoepo Flooring System 185

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

High Performance Solutions and Compounds for Roofing and Structural Waterproofing

Your guide to home maintenance. Flat Roofs

TERMOSIGN APPLICATION INSTRUCTIONS

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

DENSO WATERPROOFING SYSTEMS

USER GUIDE Easier, Safer, Betta! WATERPROOFING

Acrylic Enamel Topcoat

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

The AQUAFIN Approach to Concrete Repair

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Resurfacing Concrete. Page 1 of 5

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

You have just purchased the most portable and economical spray chrome system in the world!

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

RECOATING AND RENEWING SPF ROOFING SYSTEMS

Guide. to Common Brick Staining. in New Construction. improving the appearance and performance of buildings

WATERPROOFING FOR CONCRETE STRUCTURES

Vulcan Basement Waterproofing DIY Guide

Tractor Painting Tips

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

Jagger Enterprises, Inc. dba Buckeye Home Inspections Dorchester Drive Cleveland OH (216) Fax (216)

Mold Preventing I nterior System

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Columbia flooring will resist fading from exposure to sunlight or artificial light.

NEOGARD. Preventive Maintenance Manual

Epoxy Floor Coating Problem Solving Guide

Rehabilitation of an Aging Concrete Reservoir Adit Tower

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

DECK WATERPROOFING AND PROTECTION SYSTEMS. Solutions for Balconies, Podiums, Car Parks and Flat Roofs

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

Retail Price List 2015

2006 ICRI Baltimore Washington Chapter Outstanding Repair Project Award George Washington University Ross Hall Façade Restoration

Cupped Floor STEP 1. Flooring absorbing excessive moisture on the underside causes expansion and cupping with the edges raised.

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Moisture Mitigation for Concrete Slabs

Water Damage & Repair

Metropolitan Builders Association Masonry & Concrete Standard

European Technical Assessment ETA-15/0028 of 23/02/2015

Customer Services - 5, rue René Panhard LE MANS Cédex 2 FRANCE Tel.: (+33) p.ball@colart.fr

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

Mineral waterproof coating PCI Dichtschlämme

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

K2 STONE NATURAL VENEER

bout your HOUSE before you start Renovating Your Basement Moisture Problems

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

8.7 Schluter -KERDI-LINE

How to Install Hardwood Flooring Over a Sub Floor

Acrylic Coatings: The Perfect Stucco Finish

Passive Fire Protection

Chapter 2 Basis of design and materials

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

bout your house before you start Renovating Your Basement Moisture Problems

How To Replace A Roofing System In Florida

Ultracolor CG2. Fast setting and drying grout for 2 to 20 mm joints, available in 26 colours; does not produce efflorescence

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

RAPTOR TRUCK BED LINER - BLACK

Points of Construction

Transcription:

WATERPROOFING OF BALCONIES AND TERRACES Edited by : Leon Bancken DEFINITION OF THE PROBLEM THE DIRECT CAUSES OF THE DAMAGE IS THERE A SOLUTION? THE RD-COATINGS WATERPROOFING SYSTEM FOR TERRACES AND BALCONIES THE ON-SITE INSPECTION THE APPLICATION OF THE RD-COATINGS BALCONY OR TERRACE WATERPROOFING SYSTEMS.

The weather resistant durable RD - Coatings terrace sealing system DEFINITION OF THE PROBLEM : It mostly concerns outside balconies or terraces, which are equipped on the outside with upstanding borders made of concrete, pebbles or flint containing concrete or made of a closed concrete structure. Generally, a concrete border is used to divide different balconies. Through this, the rain is guided, by means of a gutter, to a drain pipe. The defects can almost always be detected at the underside of the balconies. There is formation of stalactites ; these contain calcareous substances that reject the paint. The damage has highly progressed, at the moment that rust bleeds appear and visibly corroded the steel reinforcements in the concrete. THE DIRECT CAUSES OF THE DAMAGE The infiltration of rain in the concrete can be the result of various design or construction errors. The missing of a sealing between the flooring compound filling coat and the concrete, is the most usual error. Another possible default is a sealing of low quality, which causes cracks or a cracked sealing due to the physical settling of the building and which is hardened on the long term. The rain seeps through the balcony coverage (tiles) into the stabilized sand, penetrates further on in the concrete floor and forms the stalactites. When nothing is done to counter the penetration of the water, the reinforcement steel in the concrete will be attacked and will corrode. The result will be the cracking of the concrete. As a matter of fact the damage is a result of rain, which means that the damage pattern is highly influenced by the rain pattern. 2

IS THERE A SOLUTION? To prevent further damage to the balcony and terrace floors, one has to fight the cause of the problem : avoid the further penetration of water through the concrete floor. Basically, this can be done by the following two ways : A. One provides an efficient, fully waterproof substrate covering. B. The application of a sealing beneath the balcony floor. This last solution is a structural quite difficult procedure : the balcony or terrace floor has to be fully removed and a lasting waterproof covering, like a synthetic or bituminous foil, has to be used. The sand-cement bed has to be renewed and be covered by lasting tiles. These transformations can cause a lot of nuisance to the residents and pollute their habitat. In the narrow sense of the word, a gua - rantee can t be granted on waterproofing, as in the long run the movements of the balconies, due to variations in temperature and humidity, can cause cracks in the sealing. While this can t be detected, one has to start all over again, if necessary! 3

THE RD-COATINGS WATERPROOFING SYSTEM FOR TERRACES AND BALCONIES As a paint and waterproofing products manufacturer, Dothée has developed a waterproofing system for balconies and terraces, that offers a suitable solution to damage to these objects caused by prolonged rain infiltration. This system guarantees a lasting waterproofing. Due to the ongoing elasticity, the movements of the substrate, made by variations in temperature and humidity, are absorbed. This will prevents cracking. The system is weather resistant, gives easy maintenance and resists to normal pedestrian traffic. Do you want our advice? Just let us know! A technical representative from our company will come on the spot. After a thorough examination on the object he will, orally or in writing, give a free, noncommittal technical advice. We offer to do one or several inspections on the job during the works, which will guarantee a perfect result. 4

THE ON-SITE INSPECTION : > The surface of the terrace is submitted to a thorough examination : Control of the stability of the balcony substrate ; loose tiles or pavements are detected by knocking on the substrate. When ne - cessary, they are fixed with a shrink-resistant mortar ; the RD- CEMENTFILLER for example. Inspection of the drain pipes ; these are unblocked or replaced, when they show bursts or have hardened. A fter that, an efficient cleaning needs to be done. A dry cleaning, if possible, to avoid a further moist saturation. L eave to dry thoroughly, whenever the substrate needed to be cleaned by high pressure cleaning. THE APPLICATION OF THE RD-COATINGS BALCONY OR TERRACE WATERPROOFING SYSTEMS > Always work on a thoroughly cleaned, stable and dry substrate. Porous surfaces : Apply an impregnation coat of RD-UNIFIX. The consumption depends on the porosity of the substrate. Smooth surfaces : Apply the RD-ELASTOMETAL as a fixation coat, diluted with 25 % water. Consumption about 6 m 2 /L. Then, apply a thick coat of RD-ELASTODECK. Stick the RD-ROOF FLEECE MS into the wet coat of RD-ELASTODECK, without folds and with fleece overlaps of 5 cm when necessary. Leave to dry. Recoat with RD-ELASTODECK, until the fleece is completely cove - red. Consumption : about 1,5 to 2 Kg/m 2, depending on the structure of the substrate. This is a fully waterproof finishing. For a smooth, maintenance friendly and dry substrate submitted to pedestrian traffic, the following finishing is recommended : Application of a coat RD-HYDROGRAFF FLOOR or RD-MONOFLOOR (waterborne polyurethane paint). Consumption : About 6m 2 /L. Anti-slip finishing : When the final coat of RD-ELASTODECK has been applied, one needs to pour quartz sand or quartz beads into the wet coat, by means of a perforated sprinkle box. This should be done after determination of the desired structure and color in agreement with the owner, architect or customer. 5

When the coat is completely dry, the superfluous grains must be brushed. If necessary, this can be done, by means of an industrial vacuum cleaner. One finishes with a topcoat of RD-HYDROGRAFF FLOOR or RD-MONOFLOOR This system gives you an advantageous price quality ratio. > Treatment of the underside of balconies or terraces : You better wait a considerable time after the application of the waterproofing system, to let the implied moisture the time to evaporate.? After a moisture control by our technical representative or by the painter/executor, the salt rejections must be thoroughly removed by scouring off and dusting off. Seal off active bursts with RD-ACRYKIT, stabilized with RD-CEMENTFILLER. Impregnate well with RD-UNIFIX and finish off with two coats of RD-MUR ACRYL. For more information about concrete repair, we refer to our catalogue «CONCRETE REPAIR», available on demand. 6