DTC1000/2000 Temperature Controller User Manual

Similar documents
+ A B V B NO NC V COM PV PV

Delta Temperature Controller User Manual

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

NC-12 Modbus Application

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

MEMOBUS/Modbus Communications

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Model: DC-A2IO Advanced HVAC Controller

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

Temp. & humidity Transmitter Instructions

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

SureServo Communication Parameters SureServo Parameter Memory Addresses Connecting to DirectLogic PLCs...6 8

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

User Manual Auto Tuning PID Temperature Controller

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Vibration Monitoring System Adash 3600

T0118 T2118 T3118. Instruction Manual

IO-RM3 3-Stage Relay Module

PD 100A. Printing data system

User Manual for CH-PFC76810

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

WD-AMX Water Detection Controllers

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Application/Connection Examples

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

1 Serial RS232 to Ethernet Adapter Installation Guide

Telefon (+45) Telefax (+45) Installation and operating manual

Duct Humidity Transmitter

Adjustment functions for both span and shift have been incorporated

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

WEB log. Device connection plans

User s Manual Before using the inverter, you need to read and save the safety instructions.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DLP-PU/E Instruction Manual

Quick Connect. quick - simple - efficient.

Unidirectional Transmitter/ Receiver Units Introduction

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Telephone- and leased line modem for industrial applications TD-36

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DS Wire Digital Thermometer and Thermostat

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

WEB log. Device connection plans

DS1621 Digital Thermometer and Thermostat

Transmitter Interface Program

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

PowerLogic Sub Meter Display (SMD and SMDOPN)

CQM1-SF200/CS1W-SF200

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Nemo 96HD/HD+ MODBUS

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Digital and Analog I/O

PCS0100en Persy Control Services B.V. Netherlands

IO-DIM6 6-Channel, Digital to Analogue Converters

INTMOD485-LH Protocol Converter

ZC-24DO CANopen I/O Module: 24 Digital Outputs

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

DS1621 Digital Thermometer and Thermostat

=============================== WARNING

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Contents. Document information

Antec TruePower User's Manual

Rosemount 333 HART Tri-Loop

Operational Overview and Controls Guide

Power Supplies 3. SDN-P DIN Rail Series

RS - SPM. Serial parallel translator module

Temperature & Humidity SMS Alert Controller

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

1 Application Description Objective Goals... 3

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

REGTRONIC OPERATING INSTRUCTIONS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Series 6000 Torque measured metal bellow coupling

Rack mounted telephone- and leased line modem for industrial applications

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Thyristor-controlled power supplies and battery chargers

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

Temperature Controller USER S MANUAL

Safety technique. Emergency stop module BO 5988 safemaster

Transcription:

http://www.delta.com.tw/industrialautomation/ DTC1/2 Temperature Controller User Manual Thank you very much for purchasing DELTA C Series Temperature Controller. Please read this instruction sheet before using your C series to ensure proper operation and please keep this instruction sheet handy for quick reference. 1 Precaution DANGER: ELECTRIC SHOCK! DTC1 is an OPEN-TYPE Process Control Equipment and DTC2 is an OPEN-TYPE Process Control Accessory. These devices are microprocessor-based temperature regulating controllers which may be provide with normally closed and/or open contacts. They are intended for installation completely within an overall panel or Process control Enclosure and are used in heating or cooling applications. Please Install within a separate UL Listed enclosure only, keep the enclosure away from airbome dust or high humidity and prevent electric shock or sudden shock. Also, it is equipped with protective methods such as some special tool or key to open the enclosure, so as to avoid the hazard to users or any damage to the module. 1. Prevent dust or metallic debris from falling into the controller that will cause malfunction. 2. Do NOT modify or disassemble the controller. 3. Do NOT connect to No Used terminal. 4. Do not install and/or use the controller in places subject to: (a) Dust or corrosive gases and liquid. (b) High humidity and high radiation. (c) Vibration and shock. (d) High voltage and high frequency 5. Power off when wiring and changing an input sensor. 6. Be sure to use compensating wires that match the thermocouple types when extending or connecting the thermocouple wires. 7. Shorten the wire when wiring a platinum resistance thermometer (RTD) to the controller and separate power cable from load wires to prevent interference and conductive influence. 8. Make sure power cables and signals device are installed properly before power on; otherwise serious damage may occur. 9. Do NOT touch the terminals or repair the controller when power on to prevent electric shock. 1. Wait at least one minute after power off to allow capacitors to discharge, and do not touch any internal circuit within this period. 11. Do NOT touch internal terminals no matter power on or off. 12. For temperature accuracy, keep the controller away from heating source. 2 MODEL NAME EXPLANATI DTC 1 2 3 4 5 DTC Series 1 Controller Position DTC: Delta C series Temperature Controller 1: first controller 2: controller in parallel 1

2 Auxiliary Output Groups : standard, 2 groups output, no auxiliary output 1: 1 group auxiliary output. Not available now. 2: 2 groups auxiliary output. Not available now. 3 4 Optional : standard 1: CT input. Not available now. 2: Event input. Not available now. 5 Main Output R: Relay output SPST, 25VAC, 3A Type V: Voltage Pulse output 12V +1 % ~-2 % C: Current output 4~2mA L: Linear Voltage output ~1V Standard: DC24V input, Relay output for 2 nd group, RS-485 communication. 3 FUNCTI AND SPECIFICATI Power Supply DC24V. Isolated switching power Voltage Range Rated voltage: 9%~11% Power Rated 24 Vdc, Max. 24 W combined, 3 W + 3 W x no. of DTC-2 (max. 7 consumption connected) Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK Sensor Type Platinum RTD: Pt1, JPt1 Linear DC input: ~5V,~1V, ~ 2 m A,4~2 m A, ~5mV Sampling Rate Control Method Output Type Output Function Analog input:.15 sec. Thermocouple or Platinum RTD:.4 sec. PID, PID program control, Manual or / Relay output (SPST), Max. load 25VAC, 3A resistive load Voltage pulse output: DC 12V, Max. output current 4mA Current output: DC 4 ~ 2m A output (Load resistance: Max. 5Ω) Analog voltage output: ~1V (Load resistance shall be higher than 1Ω) Control output, Alarm output, or Retransmission output (only for linear voltage and current output as 1 st group) 12 Alarm mode selections RS-485 digital communication, 24bps~384bps. Alarm Function Communication Communication Protocol Internal Connection Vibration Resistance Shock Resistance Ambient o C to +5 o C Temperature Storage -2 o C to +65 o C Temperature Altitude 2m or less Relative Humidity 35% to 85% RH (non-condensing) Pollution Degree Degree 2 Mod-bus communication protocol, support RTU/ASCII. Provide internal connection terminals to transmit 24V power supply and communication signal. 1 to 55Hz, 1m/s 2 for 1min, each in X, Y and Z directions Max. 3m/ s 2, 3 times in each 3 axes, 6 directions 2

4 PRODUCT PROFILE AND OUTLINE 1 2 3 25.2 4 5 4. 6 7 8 1 9 3 11 12 13 3.4 6. 3. 9. 3. DTC1R/V/C/L 1. RUN/STOP switch 2. Wiring and Model name 3. DIN fix 4. I/O terminals 5. LED indicators 6. Extension hole of the extension unit mounting pins 7. Specification label 8. Extension port 9. Extension clip 1. DIN rail 11. RS-485 communication port 12. Extension clip 13. DC power input 1 2 25.2 3 4 4. 5 6 7 9 8 2 1 3.4 6. 3. 9. 3. DTC2R/V/C/L 1. Wiring and Model name 2. DIN rail clip 3. I/O terminals 4. LED indicators 5. Extension hole of the extension unit mounting pins 6. Specification label 7. Extension port 8. Extension clip 9. DIN rail 1. Extension port 5 INPUT SENSOR TYPE Input Selection for DTC series: Input Sensor Type Register Value Available Range ~5mV Linear Voltage Input 17 ~5mV 4~2mA Linear Current Input 16 4~2mA ~2mA Linear Current Input 15 ~2mA ~1V Linear Voltage Input 14 ~1V ~5V Linear Voltage Input 13 ~5V Platinum RTD (Pt1) 12-2 ~ 6 o C (-328~1112 o F) Platinum RTD (JPt1) 11-2~ 4 o C (-4~752 o F) Thermocouple TXK type 1-2~8 o C (-328~1472 o F) Thermocouple U type 9-2~5 o C (-328~932 o F) Thermocouple L type 8-2~85 o C (-328~1562 o F) Thermocouple B type 7 1 ~ 18 o C (212~3272 o F) Thermocouple S type 6 ~ 17 o C (32~392 o F) Thermocouple R type 5 ~ 17 o C (32~392 o F) Thermocouple N type 4-2 ~ 13 o C (-328~2372 o F) Thermocouple E type 3 ~ 6 o C (32~1112 o F) Thermocouple T type 2-2 ~ 4 o C (-328~752 o F) Thermocouple J type 1-1 ~ 12 o C (-148~2192 o F) Thermocouple K type -2 ~ 13 o C (-328~2372 o F) 3

Note 1: an external 25Ω precision resistor is needed for current input. Note 2: factory setting: PT1 input. It is adjustable for linear input and feedback ranges. The default range of input feedbadk is 999~9999. For example, when a ~2mA analog input is selected as the input temperature sensor type, -999 indicates ma and 9999 indicates 2mA. If change the input range to ~ 2, then indicates ma and 2 indicates 2mA. One display scale is equal to.1ma. 6 OUTPUT FUNCTI Output control for DTC is selective: Control output (heating, cooling), Alarm output, or Retransmission output. Control Output: Temperature can individually be controlled by two groups outputs: cooling (forward) or heating (reverse). When Dual Loop output control is used, two output controls shall be designed for cooling (forward) or heating (reverse). If two control outputs with the same direction are performed, only 1 st group control period is valid. Control methods: PID control, / control, Manual control, and PID program control. Single-output Control: Heating Hysteresis Cooling Hysteresis Heating Cooling Set Point Set Point Figure1: - control of single output Output Output 1% Cooling 1% Heating Set Point Figure 2: PID Control, forward (cooling) control Set Point Figure 3: PID Control, reverse (heating) control Dual Output Control: Heating hysteresis Heating Set point Dead band Figure 4. - control of dual loop output Cooling hysteresis Cooling 4

Output Dead band:dead band width:positive Output Dead band:dead band width:negative Heating Cooling Set Point Figure 5: PID control, Dead band is positive Heating Set Point Cooling Figure 6: PID control, Dead band is negative Description of Function and Parameters Setting: PID program control by 8 patterns (Pattern No. ~7) is supported in DTB series. Each pattern contains 8 steps (step No. ~ 7), one Link Pattern parameter, one Cycle parameter and one Actual Step parameter Start Pattern: is in operation mode and it is used to set the Start Pattern of PID program control (This parameter appear in mode only). Steps: Include set point X and execution time T, these two parameters setting. The set point (SV) should reach temperature X after the period of execution time T. If the set point is the same as the result of the previous setting, then it is called Soak program control. If not, then it is called Ramp program control. Therefore, PID program control is also called Ramp/Soak program control. The default of step No. in this controller is Soak program control. The controller will control the temperature () to reach the set point X and then keep the temperature at set point X. The period of execution time is time T which provided by step No.. Link Pattern Parameter: For example, when set to 2, it indicates that pattern No. 2 will execute next after the execution of pattern No.. If set to, it indicates the program will stop after executing the current pattern and the temperature will keep at the set point of the last step. Cycle Parameter: Additional execution cycle number. For example, when set to 2, it indicates that pattern No. 4 should execute twice in addition. Include origin one time execution, total execute three times. Actual Step Parameter: Execution step number per pattern (can set to ~ 7). For example, when set to 2, it indicates that pattern No 7 will not execute other steps than step to step2. Execution: When is set to, the program will start to execute in order from the step of start pattern. When is set to, the program will stop and the control output is disabled. When is set to, the program will stop and the temperature at that time will be controlled at the set point before program stop. Select again, then the program will restart and execute from step of start pattern. When is set to, the program will hold and the temperature at that time will be controlled at the set point before program hold. Select again, then the program will follow the step before hold and start to execute through the rest of the time. Retransmission Output: When the 1 st group output of this controller is linear voltage or current output, it can be Retransmission that is the output variation corresponding with input. For example, when read 5

value= with input range ~1, output will be ma or V. When read value=1, output will be 2mA or 1V. Output Output 1V or 2mA Output slope is negative 1V or 2mA Output slope is positive V or 4mA V or 4mA Low High Low High Figure 7: Retransmission Alarm Output: This controller provides twelve types of alarm input selections. When is higher or lower than SV, alarm output will act. Following table consists of twelve alarm output modes. SV Alarm Type Alarm Output Function No Alarm Function Output is 1 2 3 4 5 6 7 8 9 1 11 Deviation upper- and lower-limit: This alarm output operates when value is higher than the setting value SV+(AL-H) or lower than the setting value SV-(AL-L). Deviation upper-limit: This alarm output operates when value is higher than the setting value SV+(AL-H). Deviation lower-limit: This alarm output operates when value is lower than the setting value SV-(AL-L). Reverse deviation upper- and lower-limit: This alarm output operates when value is in the range of the setting value SV+(AL-H) and the setting value SV-(AL-L). Absolute value upper- and lower-limit: This alarm output operates when value is higher than the setting value AL-H or lower than the setting value AL-L. Absolute value upper-limit: This alarm output operates when value is higher than the setting value AL-H. Absolute value lower-limit: This alarm output operates when value is lower than the setting value AL-L. Deviation upper- and lower-limit with standby sequence: This alarm output operates when value reaches set point (SV value) and the value is higher than the setting value SV+(AL-H) or lower than the setting value SV-(AL-L). Deviation upper-limit with standby sequence: This alarm output operates when value reaches set point (SV value) and the reached value is higher than the setting value SV+(AL-H). Deviation lower-limit with standby sequence: This alarm output operates when value reaches the set point (SV value) and the reached value is lower than the setting value SV-(AL-L). Hysteresis upper-limit alarm output: This alarm output operates if value is higher than the setting value SV+(AL-H). This alarm output is when 6 AL-L SV AL-H AL-L SV SV AL-H AL-L SV AL-H AL-L AL-H AL-L AL-L SV AL-L SV AL-H AL-H SV AL-H AL-L AL-H

SV Alarm Type Alarm Output Function value is lower than the setting value SV+(AL-L). 12 Hysteresis lower-limit alarm output: This alarm output operates if value is lower than the setting value SV-(AL-H). This alarm output is when AL-H AL-L value is higher than the setting value SV-(AL-L). Attention: AL-H and AL-L include AL1H, AL2H and AL1L, AL2L. When the 1 st group output is set to alarm output, AL1H (124H) and AL1L (125H) will be used. When the 2 nd group output is set to alarm output, AL2H (126H) and AL2L (127H) will be used. 7 LED DISPLAY 1. When power is normal, POWER LED will be lit. 2. LED will be lit after power on. Within one second after power on, communication protocol will be displayed; and at the following second after communication protocol displayed, communication will be displayed. After that, LED will all be lit to show operation is normal. 3. When control action is executing, RUN LED will be lit. 4. When input, memory, or communication happens to error, ERROR LED will be lit. 5. When output is acted, the corresponding LED will be lit. 6. When PID program is auto adjusting parameter, AT LED will blink. 7. RX LED will blink when receiving communication signal and TX LED will blink when transmitting communication signal. Protocol Format of LED Display When Power On AT TX RX O1 O2 Err Run :24bps 1:48bps 1:96bps 11:192bps 1:384bps Parity :None 1:Even 1: Odd : ASCII 1: RTU :2 Stop bit 1:1 Stop bit Communication display: AT (bit 6) and Run (bit ) will combine to binary code. 8 PASSWORD FUNCTI The default of password will not operate. After writing 4- password into specific communication, password function will be activated. There are three levels for password protection: 1. Level1: only LED status, settings, and input values can be read via communication. It is unable to revise anything. 2. Level2: only LED status, settings, and input value can be read via communication. Also, it is able to revise setting. 3. Level3: all the settings can be read via communication, but it is only revisable for settings and AT adjustment. 4. No password function. Once password is set (16EH~17H), the controller will enter level 1. For entering another level, please key in corresponding password in 16BH~16DH (see Address and content of Data Register). After power off, it will get back to level one. If password protection function shall be dismissed, it is necessary to clear all password setting. To enable password function, it is necessary to write corresponding password (16EH~17H) when password status is dismissed. To dismiss password levels, intended password setting should be write in specific function 16EH~17H. Password status can be read from 16EH~17H. Statuses corresponding to each bit are shown as the following table: Bit b b1 b2 b3 b4 b5 b6 Status Level 1 Level 2 Level 3 Level 1 locked Level 2 locked Level 3 locked Unlock 7

Bit= means no password setting. Bit=1 means password is set (b~b2). b3~b6 are used for displaying current password status. 9 SYNCHROUS COMMUNICATI PROTOCOL & AUTO NUMBER ID FUNCTI By using Auto Number ID function, the communication protocol of DTC2 can be set the same as the one of DTC1. ID numbers tend to increase. 1. Set the auto communication flag to be 1 for DTC1 (communication 122H). 2. Switch off the controller before connecting to another DTC2. After that, switch on the power again. 3. Communication default: 96bps, 7bits, Even, 1 stop bit. 4. This function will result in additional 3~5 seconds for power on. 1 RS-485 COMMUNICATI 1. Supporting transmission speed: 24, 48, 96, 192, 384bps. 2. Non-supported formats: 7, N, 1 or 8, E, 2 or 8, O, 2. 3. Communication protocol: Modbus (ASCII or RTU) 4. Function code: 3H to read the content of register (max. 8 words). 6H to write one word into register. 1H to read bits data (max. 16 bits). 5H to write one bit to register. 5. Address and Content of Data Register: Address 1H Setting Content Process value () Explanation Temperature unit:.1 degree. Analog input: 1EU. Following read values happen to errors: 82H : Initial process (Temperature value is not got yet) 83H : Temperature sensor is not connected 84H : Temperature sensor input error 86H : Cannot get temperature value, ADC input error 87H : Memory read/write error 11H Set point (SV) Unit:.1 degree. Analog input: 1EU. 12H 6 Upper-limit of Upper-limit ban, unit:.1 degree. temperature range 13H -2 Lower-limit of Lower-limit ban, unit:.1 degree. temperature range 14H 12 Input temperature Please refer to the contents of the Temperature sensor type Sensor Type and Temperature Range for detail 15H Control method : PID, 1:/, 2: manual tuning, 3:PID program 17H 4 18H 4 19H 476 1st group of Heating/Cooling control cycle 2nd group of Heating/Cooling control cycle PB Proportional control ~99, :.5 sec band 1AH 26 Ti Integral time ~9999 1BH 41 Td Derivative time ~9999 1CH Integration default ~1, unit:.1% 1DH Proportional control offset error value, when Ti = ~99, :.5 sec (it will be invalid when both groups are control output at the same time) 1 ~ 9999, unit:.1 degree, analog input: 1EU ~1, unit:.1% 1EH 1 COEF setting when 1 ~ 9999, unit:.1 8

Address Setting Content Explanation Dual Loop output control are used Dead band setting -999~9999, unit:.1 degree or 1EU 1FH when Dual Loop output control are used Hysteresis setting ~9999, unit:.1 degree or 1EU 11H value of the 1st output group 111H Hysteresis setting value of the 2nd output group ~9999, unit:.1 degree or 1EU 112H Output value read Unit:.1%, write is valid only under manual control and write of Output 1 mode 113H Output value read Unit:.1%, write is valid only under manual control 114H 115H 116H 12H 121H 122H 124H 4 125H 4 126H 4 127H 4 12AH 12CH and write of Output 2 Upper-limit regulation of analog linear output Lower-limit regulation of analog linear output mode 1 scale=2.8μa=1.3mv 1 scale=2.8μa=1.3mv Temperature -999~+999, unit:.1 degree or 1EU regulation value Alarm 1 type Please see the contents of the Alarm Outputs for detail Alarm 2 type Please see the contents of the Alarm Outputs for detail Auto-setting Auto setting ban of communication:, auto setting of communication flag communication: 1 Upper-limit alarm 1 Please see the contents of the Alarm Outputs for AL1H detail Lower-limit alarm 1 Please see the contents of the Alarm Outputs for AL1L detail Upper-limit alarm 2 Please see the contents of the Alarm Outputs for AL2H detail Lower-limit alarm 2 Please see the contents of the Alarm Outputs for AL2L detail Read/Write status b1:alm2, b2:, b3:, b4: ALM1, b5: O2, b6:o1, b7: AT Setting of : positive, 1: negative positive/negative proportional output 12EH LED status b: RUN,b1: ERR, b2: O2,b3: O1,b4: RX,b5:TX b6: AT 12FH Software version V1. indicates x1 13H Start pattern ~7 number 132H Remaining time of Unit: second read execution Remaining time of Unit: minute 133H reading execution step Step number of ~7 134H reading current execution step 9

Address Setting Content Explanation Executing number ~7 135H of reading current pattern 137H 1 Upper-limit of ~1% max. analog output is upper limit, unit:.1% proportional output 138H Lower-limit of ~1% max. analog output is lower limit, unit:.1% proportional output Actual step number ~7 = N means the pattern is executed from step from 14H~ 7 setting inside the to N. 143H correspond pattern 15H~ 153H 16H~ 163H 168H 1 169H 16AH 16BH 16CH 16DH 16EH 16FH 17H 171H 1 172H Cycle number of repeating executing pattern ~7 Link pattern number setting of the current pattern Control execution/stop setting Output 1: control selection Output2: control selection Dismiss level 1 Read/write allowed Dismiss level 2. Use level 3. Dismiss level 3. Use level 2 Dismiss level 1/Set password Dismiss level 2/Set password Dismiss level 3/Set password Read/Write communication Read/Write communication format ~199 means the pattern is executed for 1~2 times. ~8, 8 means program end. ~7 means the next execution number after completing current pattern. : Stop, 1: execute, 2: program end, 3: program hold : heating, 1: cooling, 2: alarming, 3: proportional output : heating, 1: cooling, 2: alarming Shall be same as level 1 password setting (16E) Shall be same as level 2 password setting (16F) Shall be same as level 3 password setting (17) Clear old password before new password setting Clear old password before new password setting Clear old password before new password setting 1~247 RTU:1, ASCII: 173H 2 Baud rate setting of communication ~4: 24~384 174H 1 Data length setting of communication : 8bit 1: 7bit 175H 1 Parity bit setting : None 1:Even 2: Odd 176H 1 Stop bit setting : 2 stop bit 1: 1stop bit Pattern ~7 to set 2H~ target temperature 23FH Pattern : 2H~27H 28H~ 2BFH Pattern ~7 to set execution time. Pattern : 28H~287H Temperature measure unit:.1 degree Time ~9 (1 minute for each scale) 1

6. Address and Content of Bit Register: ( First bit of reading will put into LSB, Write data = FFH for bit set, H for bit data as ) 811H Temperature unit display selection : o F, 1: o C (default) 813H AT setting AT setting : (default), AT setting : 1 814H Control RUN/STOP setting : STOP, 1: Execute (default) 815H Program hold flag 1: Program temporary stop 816H Program stop flag 1: Program stop 7. Communication format:1: read bit data, 5: write bit data, 3: read word, 6: write word. ASCII Mode: To Read Instruction To Read Response Message To Write Instruction To Write Response Message Starting word Machine 1 Machine Instruction 1 Instruction : : Starting word Machine 1 1 1 Machine Instruction 1 3 1 Instruction : : Starting word : : Starting word Machine Machine 1 1 1 1 Machine 1 1 Machine Instruction 1 Instruction 1 3 1 Instruction 6 5 Instruction : : 1 1 6 5 1 Response data 1 1 To read To write To write 8 length () 4 2 8 8 data/staring data data 1 1 1 1 word Data content of 1 7 1 1 To read data 1H/81xH F F F length/word 4 1 To write 3 F To write 3 F length data content E data content E (word/bit) 2 9 8 8 LRC1 check E D Data content of LRC1 F E LRC1 F E 11H LRC check A D LRC D 3 LRC D 3 Ending word 1 CR CR LRC1 check E Ending word 1 Ending word LF LF LRC check 3 4 Ending word Ending word 1 CR CR CR LF CR Ending word 1 LF Ending word CR LF CR LF Ending word LF LF LRC Check: LRC check is the added sum from Machine Address to Data content. For example, 1H + 3H + 1H+ H + H + 2H = 16H, then take the complementary of 2 to get EA. RTU Mode: 11

To Read Instruction Machine 1H 1H To Read Response Message Machine 1H 1H To Write Instruction Machine 1H 1H Machine To Write Response Message Instruction 3H 2H Instruction 3H 2H Instruction 6H 5H Instruction 6H 5H Starting 1H 8H 1H 8H 1H 8H Response To write To write of H 1H data length 4H 2H data 1H 1H data 1H 1H reading () data To read data length (word/bit) CRC low CRC high H H 1H 17H To write 3H FFH To write 3H FFH Data content 2H 9H 1 F4H 1H data 2H H data 2H H content content CH BBH 3H CRC low DDH 8FH CRC low DDH 8FH Data content CBH A9H 2 2H CRC high E2H 9FH CRC high E2H 9FH CRC low CRC high BBH 77H 15H 88H 1H 1H Following is a CRC (Cyclical Redundancy Check) program example: unsigned int reg_crc = xffff; i = ; while (length--) { reg_crc ^= RTUData[i]; i ++; for (j = ; j < 8; j++) { if (reg_crc & x1) reg_crc = (reg_crc >> 1) ^ xa1; else reg_crc = reg_crc >> 1; } } return(reg_crc); 11 INSTALLATI DTC modules can be expanded up to 8, and installed with DIN rail mounting Delta Electronics, Inc. 31-1 Shien Pan Road, Kuei San Industrial Park, Taoyuan Shien 33341, Taiwan, R.O.C. TEL: 886-3-362-631 FAX: 886-3-362-7267 12