User s Manual AURORA 1.2K/2.2K



Similar documents
How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Online UPS. PowerWalker VFI 1000R/1U

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

Powerware 5110 UPS User s manual

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

350, 500, 650 and 1000 MODELS

How To Use A Power Supply Unit (Upland)

User Manual 1K/2K/3K Online UPS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USER MANUAL Online UPS 1K/2K/3K Rack

User s Manual Before using the inverter, you need to read and save the safety instructions.

USER MANUAL Online UPS 1K/2K/3K

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

3000W Power Inverter

10000HXL31/15000HXL31/20000HXL31

SPL 2-00/-01 OPERATION INSTRUCTIONS

HP UPS R1500 Generation 3

Home Solar Kit Owner s Manual. Model: HS

2013 VTech Printed in China US

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

EKOS Cart. Instructions for Use

Installation and Operation Back-UPS 1250, 1300, 1500

Single Day Alarm Clock with. Bluetooth and USB Play-through

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Dehumidifier Users manual. For Models: DH45S DH65S

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Home Solar Kit Owner s Manual. Model: HS

Indoor Remote Controlled Power Points

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

TIG INVERTER INSTRUCTION MANUAL

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

USER MANUAL Online UPS 6K/10K RACK

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Residential Gateway (RG) Battery Backup

Model #: SMART2200CRMXL

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

UPS-2200R-HH/UPS-2200R-HHIP

Spec. No. ICR C Version No. 0.0

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

esata External Storage

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Installation and Operating Instructions (for chargers shown below)

Advantium 2 Plus Alarm

User Manual HomeGrid 3000 Solar Generator

XPower 1500 Portable Household Power

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Operating Guide Manuel de l utilisateur

Operating Instructions

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

Installation and Operating Instructions (for chargers shown below)

VLT Series 300 Watt True Sine Wave Inverter

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Table Of Contents

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Back-UPS Pro 1300/1500 Installation and Operation

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

E Manual N Phoenix

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Operating Instructions

NeTYS PR VA

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

400 Amp Rechargeable Jump Start System RAC-HP082

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Battery Power Inverters

Transcription:

User s Manual AURORA 1.2K/2.2K Uninterruptible Power System

Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 24Vdc. Sealed, lead-acid, 6 cells battery two pcs. Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of batteries in a fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots.

4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminals. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type of sealed lead-acid battery. The maximum ambient temperature rating is 40. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. INTRODUCTION This UPS is specially designed for Personal Computer with multi-functions. Its light weight, compact design perfect fits to the limited working environment. The line of UPS is equipped with boost and buck AVR to stabilize input voltage range. It is also built-in with DC start function. This function enables the UPS to be started up without AC power supplied. Although it s a small UPS, The main features of Aurora UPS are listed below: Microprocessor control guarantees high reliability. Equipped with Boost and Buck AVR. Green Power Function for energy saving. DC Start Function. Auto restart while AC recovery. Compact size, Light Weight. Provides AC Overload protection.

TROUBLE SHOOTING Symptom Possible Cause Remedy No LED display on 1. Battery weak. 1. Charge battery up to 8 hours. the front panel. 2. Battery defect. 2. Replace with the same type of battery. 3. Power switch is not pressed. 3. Press the power switch again. Alarm buzzer beeps continuously when AC supply is normal. When power failure, back-up time is shorten. Mains normal but LED is flashing. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs. 1. Overload of the UPS. 1. Remove some non-critical load. 2. Battery voltage is too low. 2. Charge battery 8 hours or more. 3. Battery defect due to high 3. Replace with the same type of temperature operation battery. environment, or improper operation to battery. Power cord is loose. Reconnect the power cord properly. If any abnormal situations occur that are not listed above, please call service people immediately. SYSTEM DESCRIPTION Front panel: 1.Power Switch 2.LED Indicators AC Mode: Green lighting Battery Mode: Green flashing 3.Fault LED 4. LED Indicators AC Mode: Load Level LEDs Battery Mode: Battery Capacity LEDs

Back Panel 1. AC input 2. Output receptacles 3. USB & RJ45 communication 1 3 1 2 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Turn on the UPS, Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load (no electrical devices such as computers, monitors, etc.) connected.

3. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS away from the monitor at least 20cm to avoid interference. 4. Connection Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. 5. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again.

6. DC Start All Aurora Series are equipped with DC Start. To start the UPS when AC utility power is not available, simply press the power switch. 7. Green Power Function All Aurora UPS is equipped with Green Power Function. For saving power and protecting battery, the method of deep discharging protection is adopted on inverter mode.

SPECIFICATION MODEL AURO 1200/2200 CAPACITY VA/W 1200VA/600W 2200VA/1100W Voltage 120VAC or 230VAC INPUT Voltage Range 85-145VAC or 170-280VAC Voltage 110/120VAC or 220/230/240VAC Voltage Regulation (Batt. Mode) +/-10% Frequency 50Hz or 60Hz OUTPUT Frequency Regulation (Batt. Mode) +/-1 Hz Output Waveform Modified Sine wave BATTERY Battery Type 12V7Ah x 2 12V/9Ah x 2 Recharge Time 6 hours to 90% after complete discharge TRANSFER TIME INDICATOR AUDIBLE ALARM Typical AC Mode Backup Mode Backup Mode Low Battery Overload Fault Green lighting Green flashing 4-8 ms The 4st Green Led Lighting. Optional -- (The 1st to 3th green Led lighting to indicate load level) LED1 (green): >66% load level. LED2 (green): >33% load level. LED3 (green): >0% load level. The 4st green blinking. Optional -- (The 1st to 3th green Led lighting to indicate battery capacity) LED1 (green): battery voltage > 12.5V. LED2 (green): battery voltage > 11.5V. LED3 (green): battery voltage > 10.5V. Sounding every 10 seconds Sounding every 1second Sounding every 0.5 second Continuously sounding PROTECTION Full Protection Discharge, overcharge, and overload protection PHYSICAL Dimension (mm), DXWXH 365(L)x139(W)x195(H) WEIGHT Net Weight 8.6kgs 10.2kgs Operating Environment 0 C - 40 C ENVIRONMENT Noise Level Less than 40dB