Test Report # Rev 2. Nitrous Oxide Compatibility Test

Similar documents
solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

Veriflo Pressure Regulators

Regulator Flow Curves For Bulk Gas Systems, Cylinder Gas Cabinets and Gas Distribution Systems Report # Rev 4

KNC Model 3666 Automatic Pressure Calibration System

Compact, High-Flow Gas Regulators

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

BRAKE SYSTEM OVERVIEW AND OPERATION PROCESS 1. BRAKE SYSTEM GENERAL INFORMATION 1) DESCRIPTION AND OPERATION 16-3.

(A5) Brakes Sample Questions and Answers

SOFT START VACUUM VALVES. Vacuum Valves. Two-Stage Valves

Inspired By Challenge. Technical information polymer characteristics

Flanged and Butt-= Weld Type

A practical guide to restrictive flow orifices

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

NITROUS TRANSFER PUMP INSTRUCTIONS

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

P O B o x S t. L o u i s, M O P h o n e : ( ) ~ E m a i l : w m h u I t a o l.

Validation of process gas systems

Why and How we Use Capacity Control

The First Line of Safety

Recharge Procedure for Telemark TVP-2000 and TVP-3500

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

automatic Changeover regulators and systems manifolds/changeover regulators

Specification Data CM /10. Putting You In Control Series MiniTork ll Control Valves. Heavy Duty Control Butterfly Valves

SELECTION, APPLICATION AND MAINTENANCE

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Grade Level Spill Containment Manholes

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

MODEL J SERIES CONVERTER

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

Molar Mass of Butane

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

Bench Top Reaction System

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Valve Live Loading With Belleville Springs. Belleville Springs for Valve Live Loading

Polyimide labels for Printed Circuit Boards

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

STANDARD FOR SECONDARY CONTAINMENT TESTING OF UNDERGROUND STORAGE TANK SYSTEMS I. INTRODUCTION

COEFFICIENT OF THERMAL EXPANSION FOR VARIOUS MATERIALS AT DIFFERENT TEMPERATURES

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Block and Bleed Gauge Valves M25 and M251

Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications

LEAKAGE ACCEPTANCE RATES COMPARISON METAL & SOFT SEATED VALVES API 598/API 6D/MSS SP-61/FCI 70-2

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

Gas Custody Transfer Calibration

APPLICATION OF BUTTERFLY VALVES FOR FREE DISCHARGE, MINIMUM PRESSURE DROP, AND FOR CHOKING CAVITATION

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

SANITARY GRAVITY SEWER LINE TESTING. B. Section CCTV Inspection of Gravity Sewer Lines

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

RIVET BUSTERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

CYLINDER LEAKAGE CHECK (Compression)

Performance Analysis of a. for a Diesel Engine

Propane as the Alternate Fuel for Fleets

University of Tennessee Safety Guidelines

Models SFP33 & SFP32 Pressure Transmitters

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Free piston Stirling engine for rural development

AMPSEAL* Automotive Plug Connector and Header Assembly

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Pressure Relief and Regulating Valves

Morrison Bros. Co. General Product Specifications

Foam Firmness Measurements IFD For Most Furniture And Bedding Applications

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

08.08 Vic-Check Valves

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Your safety and the safety of others are very important.

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Fisher 377 Trip Valve

MC4-50 Feeding System

All Safe, Inc. Sherwood Master Distributor Toll Free: Fax:

Spiroflex spiral-wound gaskets

OEM-EP Pressure Controllers

Doc. No. NDP 015M-15 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-10 series

ALMATEC Series CX CX 10 CX 130

SELECTION, APPLICATION AND MAINTENANCE

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

CONDENSING TANKLESS WATER HEATERS

API Flanged Safety Relief Valves Series 526 CATALOG

ENVIRO-SEAL. Valve Packing Systems Extending service life. Meeting environmental requirements.

Physical and Chemical Properties of Matter

There are three primary static sealing methods in use today; the flat gasket. And the molded elastomer seal.

PLUMBING RE-SUBMITTAL

Triple Point Experiment

User s Guide CARBON DIOXIDE CYLINDERS AND REGULATORS

Fisher 657 and 667 Diaphragm Actuators

Cartridge Filter Application Notes

Transcription:

Test Report # 30016497 Rev 2 Nitrous Oxide Compatibility Test Scope: This test report contains chemical compatibility test data of nitrous oxide with PCTFE (Daikin Neoflon M-400H), polyimide (Dupont Vespel SP-1), and PTFE (DuPont Teflon grade 8A). Copyright October 2010 Advanced Pressure Technology 687 Technology Way Napa, CA 94558 Telephone: 707-259-0102 This test report is the property of Advanced Pressure Technology ( AP Tech ) and may not be reproduced in whole or part without the permission of AP Tech.

Table of Contents Introduction...3 Swell Test...4 Compression Test...6 Summary...10 Page 2 of 10

Introduction Historical review When nitrous oxide (N 2 O) gained popularity as a semiconductor process gas in the early 1990s, sporadic failures occurred in semiconductor valves and pressure regulators with PCTFE seats. Typically, isolation valves shut off or restricted flow in the open position due to seat swelling and pressure regulators developed across-the-seat leaks due to seat material yielding. Valves that shut off or restricted flow were spring type diaphragm valves that contained relatively large volumes of PCTFE material. Regulators that developed seat leak were tied diaphragm type with limited structural support above the seat. Failed valves and regulators were located in the gas source manifold and exposed to full cylinder pressure. Polyimide (e.g DuPont Vespel SP-1) was proposed as a seat material to solve the problems. some initial success, it became common practice to specify Vespel for valve and regulators used in nitrous oxide service in the semiconductor industry. Although failures had been limited to the source gas manifold, the use of Vespel seats became standard throughout the process gas line components from the gas source manifold to point-of-use. The use of polyimide has eliminated nitrous oxide compatibility failures at semiconductor facilities, but at a cost. Polyimide material is more expensive than PCTFE and some other seat materials. In addition, polyimide has a very high compressive strength, which requires a high load to form a good seal and reduces the seal width, making the component more susceptible to seat leaks. This can be a problem in low pressure pneumatic valves (such as the AP3540 or AP4540) that have lower closing loads and in mini pressure regulators (such as the AP500) which have small diaphragms and low poppet spring forces. For these reasons, component suppliers increase the price of valves and regulators with polyimide seats. Test Parts It was proposed to evaluate the effect of nitrous oxide on PCTFE, polyimide, and PTFE under low pressure point-of-use conditions (150 psig or less) and source gas manifold pressures (nitrous oxide vapor pressure of 745 psig at 68 degrees F). Due to high flow conditions, it is possible that liquid nitrous oxide can form, so it was also proposed to evaluate exposure to liquid nitrous oxide. This test report evaluates samples of PCTFE (Daikin Neoflon M400-H), polyimide (DuPont Vespel SP-1), and PTFE (DuPont Teflon grade 8A) exposed to nitrous oxide for swelling and compressive strength changes. The material samples were disc shaped approximately 0.10 inch thick, 0.26 inch diameter, and 0.07 inch thru diameter hole. Revision History Rev 1: Removed note regarding product performance and specifications because the note is not applicable to this test report. Rev 2: Corrected typographical error in Table 2. Trademark Information Neoflon is a trademark of Daikin Industries. Teflon and Vespel are trademarks of DuPont. Page 3 of 10

Swell Test Test Setup and Protocol The thickness of the PCTFE, polyimide, and PTFE samples was measured. The samples were exposed to 100% nitrous oxide at three conditions: (1) pressurized to 150 psig, (2) pressurized to 745 psig, and (3) submerged in liquid nitrous oxide at 745 psig (vapor pressure). 100 hours, the samples were removed from the nitrous oxide environment and immediately the thickness was again measured. All tests were done at room temperature conditions (68 degrees F). The measurement accuracy was ±0.00010 inch and repeatability was ±0.00015 inch for a total measurement error of ±0.00025 inch or approximately ±0.25% of the sample thickness. Results The measurement results for the 150 psig exposure are shown in Table 1, for the 745 psig exposure are shown in Table 2, and for the 745 psig liquid exposure are shown in Table 3. The very slight swelling at 150 psig is right at the measurable range. The data at 745 psig in both gaseous and liquid exposures indicates that all materials had some swelling. The PCTFE increased ~5.5%, the polyimide increased ~1.5%, and the PTFE increased ~2.3% #1 PCTFE 0.09960 0.09985 0.25% #2 PCTFE 0.09970 0.09995 0.25% #7 Polyimide 0.10070 0.10100 0.30% #8 Polyimide 0.10055 0.10080 0.25% #13 PTFE 0.09945 0.10000 0.55% #14 PTFE 0.09950 0.09990 0.40% 0.25% 0.27% 0.48% Table 1. Sample Measurements 150 psig Exposure #3 PCTFE 0.09980 0.10355 3.76% #4 PCTFE 0.09960 0.10600 6.43% #9 Polyimide 0.10060 0.10210 1.49% #10 Polyimide 0.10070 0.10215 1.44% #15 PTFE 0.09960 0.10185 2.26% #16 PTFE 0.09945 0.10155 2.11% 5.09% 1.47% 2.19% Table 2. Measurements 745 psig Exposure Page 4 of 10

#5 PCTFE 0.09975 0.10555 5.81% #6 PCTFE 0.09950 0.10520 5.73% #11 Polyimide 0.10060 0.10215 1.54% #12 Polyimide 0.10075 0.10205 1.29% #17 PTFE 0.09950 0.10210 2.61% #18 PTFE 0.09965 0.10180 2.16% 5.77% 1.42% 2.39% Table 3. Measurements 745 psig Liquid Exposure Page 5 of 10

Compression Test Test Setup and Protocol The thickness of PCTFE, polyimide, and PTFE samples was measured. The samples were exposed to 100% nitrous oxide at three conditions: (1) pressurized to 150 psig, (2) pressurized to 745 psig, and (3) submerged in liquid nitrous oxide at 745 psig (vapor pressure). 100 hours, the samples were removed from the nitrous oxide environment, and immediately the thickness was measured and the seat was placed in a spring tester and a load was applied to obtain deflections of 0.001, 0.005 and 0.010 inch (approximately 1, 5, and 10% of material thickness). The load at each deflection point was recorded. the load test, the thickness was again measured. All tests were done at room temperature conditions (68 degrees F). The thickness measurement accuracy was ±0.00010 inch and repeatability was ±0.00015 inch for a total measurement error of ±0.00025 inch or approximately ±0.25% of the thickness. The load measurement accuracy was ±1 lbf and the deflection measurement accuracy was ±0.001 inch. Due to the deflection measurement accuracy, the data point at 0.001 inch for load has significant associated error. Results The results of the load versus deflection test for the PCTFE material are shown in Figure 1, for the polyimide material are shown in Figure 2, and for the PTFE material are shown in Figure 3. The data indicates that no significant change in compressive strength occurs with 150 psig exposure, but that the PCTFE material has a significant change and the PTFE has a slight change when exposed to 745 psig gaseous and 745 psig liquid nitrous oxide. The thickness change after exposure to nitrous oxide and before load testing is consistent with the first swell test. 250 Load vs. Deflection PCTFE, Daikin Neoflon M-400H PCTFE #19, new PCTFE #20, new 200 PCTFE #1, 150 psig PCTFE #2, 150 psig PCTFE #3, 745 psig PCTFE #4, 745 psig Load, lb-f 150 PCTFE #5, liquid PCTFE #6, liquid 100 50 0 0.000 0.002 0.004 0.006 0.008 0.010 0.012 Deflection, inch Figure 1. PCTFE Load vs. Deflection Results Page 6 of 10

350 Load vs. Deflection Polyimide, DuPont Vespel SP-1 Polyimide #21, new 300 Polyimide #22, new Polyimide #7, 150 psig Polyimide #8, 150 psig 250 Polyimide #9, 745 psig Polyimide #10, 745 psig Load, lb-f 200 150 Polyimide #11, liquid Polyimide #12, liquid 100 50 0 0.000 0.002 0.004 0.006 0.008 0.010 0.012 Deflection, inch Figure 2. Polyimide Load vs. Deflection Results 100 Load vs. Deflection PTFE, DuPont Teflon Grade 8A Load, lb-f 90 80 70 60 50 40 PTFE #23, new PTFE #24, new PTFE #13, 150 psig PTFE #14, 150 psig PTFE #15, 745 psig PTFE #16, 745 psig PTFE #17, liquid PTFE #18, liquid 30 20 10 0 0.000 0.002 0.004 0.006 0.008 0.010 0.012 Deflection, inch Figure 3. PTFE Load vs. Deflection Results Page 7 of 10

#1 PCTFE 0.09960 0.09980 0.20% #2 PCTFE 0.09970 0.09995 0.25% #7 Polyimide 0.10070 0.10095 0.25% #8 Polyimide 0.10055 0.10080 0.25% #13 PTFE 0.09945 0.09990 0.45% #14 PTFE 0.09950 0.09965 0.15% 0.23% 0.25% 0.30% Table 4. Sample Measurements 150 psig Exposure #1 PCTFE 0.09980 0.09955-0.25% #2 PCTFE 0.09995 0.09950-0.45% #7 Polyimide 0.10095 0.10090-0.05% #8 Polyimide 0.10080 0.10075-0.05% #13 PTFE 0.09990 0.09780-2.10% #14 PTFE 0.09965 0.09735-2.31% -0.35% -0.05% -2.21% Table 5. Thickness after Load Test, 150 psig Exposure #3 PCTFE 0.09980 0.10355 3.76% #4 PCTFE 0.09960 0.10505 5.47% #9 Polyimide 0.10060 0.10250 1.89% #10 Polyimide 0.10070 0.10245 1.74% #15 PTFE 0.09960 0.10185 2.26% #16 PTFE 0.09945 0.10125 1.81% 4.61% 1.81% 2.03% Table 6. Measurements 745 psig Exposure Page 8 of 10

#3 PCTFE 0.10355 0.10200-1.50% #4 PCTFE 0.10505 0.10390-1.09% #9 Polyimide 0.10250 0.10160-0.88% #10 Polyimide 0.10245 0.10205-0.39% #15 PTFE 0.10185 0.10030-1.52% #16 PTFE 0.10125 0.09990-1.33% -1.30% -0.63% -1.43% Table 7. Thickness after Load Test, 745 psig Exposure #5 PCTFE 0.09975 0.10570 5.96% #6 PCTFE 0.09950 0.10545 5.98% #11 Polyimide 0.10060 0.10250 1.89% #12 Polyimide 0.10075 0.10250 1.74% #17 PTFE 0.09950 0.10240 2.91% #18 PTFE 0.09965 0.10155 1.91% 5.97% 1.81% 2.41% Table 8 745 psig Liquid Exposure #5 PCTFE 0.10570 0.10390-1.70% #6 PCTFE 0.10545 0.10360-1.75% #11 Polyimide 0.10250 0.10215-0.34% #12 Polyimide 0.10250 0.10220-0.29% #17 PTFE 0.10240 0.10075-1.61% #18 PTFE 0.10155 0.09990-1.62% -1.73% -0.32% -1.62% Table 9. Thickness after Load Test, 745 psig Liquid Exposure Page 9 of 10

Summary Samples of PCTFE (Daikin Neoflon M-400H), polyimide (DuPont Vespel SP-1), and PTFE (DuPont Teflon grade 8A) were exposed to gaseous nitrous oxide at 150 psig, gasious nitrous oxide at 745 psig, and liquid nitrous oxide at 745 psig. A swell test and compressive strength test was performed. Swell test: The test data found very minor increase in sample thickness for all materials at 150 psig. The test data found that the thickness of all material samples increased at 745 psig the PCTFE increased ~5.5%, the polyimide increased ~1.5%, and the PTFE increased ~2.3%. The test data found that 745 psig gaseous and 745 psig liquid exposure had virtually the same effect on the material thickness. Compression test: The test data found a minor reduction in compressive strength for the PCTFE and PTFE samples exposed to 150 psig gaseous nitrous oxide. The test data found significant change in compression strength for the PCTFE samples exposed to 745 psig gasous and liquid nitrous oxide. The test data found a reduction in compressive strength for the PTFE samples exposed to 745 psig gasous and liquid nitrous oxide, but not to the same extent as the PCTFE samples. The test data indicated a minor reduction in compressive strength for polyimide exposed to nitrous oxide, but there was no obvious correlation to the individual exposure conditions. The data in this report found that nitrous oxide has a very minor effect on the physical properties of PCTFE, polyimide, and PTFE at 150 psig. The data found that PCTFE and to a lesser extent PTFE will swell and have reduced compressive strength when exposed to 745 psig gaseous or liquid nitrous oxide. exposure to 745 psig nitrous oxide, the PTCFE compressive strength dropped below that of PTFE, even though PCTFE samples not exposed to nitrous oxide had three times the compressive strength of PTFE. The data indicates that polyimide is the superior material for use at high pressure. The data in this report supports the historical review on page 3. Swelling of PCTFE at high pressure explains why spring type diaphragm valves with short stroke (approximately 0.020 inch) and relatively large volumes of PCTFE material could restrict or shut off flow. The significant reduction in strength of PCTFE at high pressure explains why regulators developed across-the-seat leaks due to yielding of the seat material. No significant swelling or compressive strength change at 150 psig explains why failures were restricted to the gas source manifold and no failures were reported in valve manifold boxes (VMBs) or process tools. Based on the data in this report, it is recommend that polyimide (Vespel SP-1) is used as the seat material in components that will be exposed to high pressure nitrous oxide (gas source manifolds). The data in this report indicate that either PCTFE, polyimide, or PTFE will perform satisfactorily at pressures of 150 psig or less in nitrous oxide service (VMBs and process tools). Therefore, for low pressure pneumatic valves (such as the AP3540 and AP4540) and mini pressure regulators (such as the AP500) used at less than 150 psig, it is recommended that PTFE or PCTFE are used instead of polyimide (Vespel SP-1) for the seat material because it will reduce cost and increase the long term seat leak integrity of the device. It should be noted that the data contained in this report cannot duplicate the exposure of seat materials to nitrous oxide in actual use conditions and that a longer duration of exposure may affect the results. Test report prepared by: Don Mitchell Research & Development Manager Page 10 of 10