A STUDY COMPARING ELECTRIC, OIL, AND PRESSURIZED WATER HEATING FOR COMPOSITE MOLDING

Similar documents
Heat and cold storage with PCM

Solid shape molding is not desired in injection molding due to following reasons.

AN OVERVIEW OF GAS ASSIST

Thermocline Management of Stratified Tanks for Heat Storage

INJECTION MOULD DESIGN: MARPLEX PVC RESINS

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature

MIT Manufacturing Processes and Systems. Homework 6 Solutions. Casting. October 15, Figure 1: Casting defects

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

NYLON 6 RESINS CORRECTING MOLDING PROBLEMS A TROUBLE SHOOTING GUIDE

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

CHAPTER 2 INJECTION MOULDING PROCESS

A Guide to Thermoform Processing of Polypropylene. Introduction

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Thermal Control of the Extrusion Press Container

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT

3D Printed Injection Molding Tool ("PIMT") Guide. Objet Ltd.

Experimental Evaluation Of The Frost Formation

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Benefits of Cold Aisle Containment During Cooling Failure

Determining the Right Molding Process for Part Design

Plastic Injection Molds

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Frequently Asked Questions

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Why Plastic Flows Better in Aluminum Injection Molds

Injection molding equipment

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Managing the Underfill Process in Transient Thermal Environments

Wet Bulb Temperature and Its Impact on Building Performance

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

4 Thermomechanical Analysis (TMA)

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Influence of material data on injection moulding simulation Application examples Ass.Prof. Dr. Thomas Lucyshyn

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Refrigeration Compressed Air Dryer Buran Ultrapulse

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

Cooking at the Speed of light!

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

Chapter 1.3 Energy management & audit

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Two-Shot Silico e Thermoplastic Medical Molding

RESPONSE TIME INDEX OF SPRINKLERS

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Infrared Thermometer Calibration A Complete Guide

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

Programming Your Electric Kiln

Effects of Tg and CTE on Semiconductor Encapsulants

OPERATING YOUR JEN-KEN GLASS KILN

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Note. OCXO: Oven Controlled Crystal Oscillator. Differential Amplifer

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Testing methods applicable to refrigeration components and systems

Waste Heat Recovery through Air Conditioning System

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Sondex Welded heat exchangers:

Optimization of Natural Gas Processing Plants Including Business Aspects

Measurement of Residual Stress in Plastics

PRESSURE DROP STUDIES IN WAVY CORRUGATED PLATE HEAT EXCHANGERS

Chapter 7: Oil Vapor Diffusion Pumps

VARIABLE VOLUME / VARIABLE SPEED SYSTEMS APPLICATIONS

Quick Guide to Injection Molding

stable response to load disturbances, e.g., an exothermic reaction.

INJECTION MOLDING PROCESSING GUIDE Polymer

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

PREFAULT MONITOR FOR AIR COOLED GENERATORS

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

SUPERHEATED STEAM/VACUUM DRYING TIMES FOR THICK LUMBER

Syngas Furnace Tubeskin Temperature Measurement

Air Conditioners Technical Data

Investigation of process parameters for an Injection molding component for warpage and Shrinkage

Controlling hygienic tank cleaning

Better DSC Isothermal Cure Kinetics Studies Using Power Compensation DSC

POURING THE MOLTEN METAL

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Integration of a fin experiment into the undergraduate heat transfer laboratory

Sample Liver Enzyme Lab

High Flux Steam Reforming

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Rittal Liquid Cooling Series

Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Micro Cryo-Trap Model 971

HEAT TRANSFER ANALYSIS OF COLD STORAGE

What is a mold? Casting. Die casting. Injection Molding Machine. Injection Molding Design & Manufacturing II. Spring 2004

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

ETC -SV. Class 0 oil-free compressed air through catalysis

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Part and tooling design. Eastman Tritan copolyester

INJECTION MOLDING FRACTIONAL MELT INDEX, HIGH DENSITY POLYETHYLENE MATERIALS

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Transcription:

A STUDY COMPARING ELECTRIC, OIL, AND PRESSURIZED WATER HEATING FOR COMPOSITE MOLDING Kip Petrykowski, Jim Fischer Single Temperature Controls 14201 South Lakes Dr. Suite B Charlotte, NC 28273 ABSTRACT Electric cartridge heaters have been used for many years to heat composite molds. They are easy to install and operate and thus make a logical choice. Unfortunately, they consume large amounts of electricity to operate, do not offer cooling, and are notorious for inconsistent heating. Oil heating has been used to heat and cool composite molds for an equally long period primarily as a carry-over from its use in other plant equipment and plant heating. Unfortunately it is very slow to build temperature, consumes large amounts of electricity, and does not fit with the modern greener philosophy of manufacturing. Due to the inherent energy savings, high temperature spectrum, precise temperature control, and fast ramp rates, pressurized water offers numerous advantages over both systems when applied to composite molding. 1. INTRODUCTION As more OE s eliminate oil heating from clean room environments and utilities cost increase, the need for a viable option to oil and electric cartridge heating has been created. Water due to its inherent properties makes an excellent choice. With the use of pressurization to increase the temperature spectrum, water can be a direct replacement for oil systems. Due to the inherent energy savings, high temperature spectrum, precise temperature control, and fast ramp rates for both heating and cooling, pressurized water systems have been used for injection molding for over 35 years. There are also numerous Aerospace companies that have recently adopted it as part of their Out-of-Autoclave (OoA) strategies. 1.1 Intent The intent of the study and consequent desire to publish or present the data, was to help provide molders with better insight into when to use each of the three (3) solutions for the molding of composite parts. Publishing and presenting of the study should also help to educate the Composites sector in technology that is not yet as ubiquitous as electric or oil heating but provides for energy consumption reductions and more consistent part quality. 1.2 Audience Companies or persons engaged in the manufacture of composite parts. 1

1.3 Scope The study is focused on (3) three primary heating methods; electric cartridge, pressurized water, and oil. It does not attempt to compare Ovens against the three methods. 1.4 Background Much of the motivation for the study was due to customer questions about cycle times, energy consumption, temperature precision, mold temp gradient, and ramp rates they could expect as they moved from oil and electric cartridge heaters to pressurized water systems. As a manufacturer of temperature control units in both water and oil, Single did not typically get involved in mold or mold design or the prediction of ramp rates for. In order to better answer customer questions about these items, the study was commissioned. The current industry perception is that oil is more precise for mold temperature control than electric cartridge but slower. Cartridges are notorious for large temperature gradients across molds but are relatively fast and easy to install. Pressurized water is relatively unknown to this sector. 2. EXPERIMENTATION 2.1 Test parameters for Oil versus Pressurized water 1. Use equipment with similar flow rates through the mold. 2. Use equipment with similar heating/cooling capacities. 3. Use similar line sizes to the test mold from both test units. Goal: 1. Determine Temperature Control Unit (TCU) temperature profiles, mold temperature profiles, and energy consumption for both systems. Test Equipment: Item Description Used Single H0.2 12 kw Heating / 41 kw Cooling Hours 10 Hours on unit Power Supply 460 V/60 Hz (3 phase) Flow 60 liters/minute rated flow Heating Lines out to mold 10 mm I.D Line Length 1.5 m Number of Lines 2 Cooling lines into TCU 10 mm I.D Line Length 3.5 m Number of Lines 2 2

Used Single D0.2 24 kw Heating / 116 kw Cooling Hours 100 Hours on unit Power Supply 460 V/60 Hz (3 phase) Flow 100 liters/minute rated flow Heating Lines out to mold 18 mm Line Length 3.5 m Number of Lines 2 Cooling lines into TCU 15 mm I.D Line Length 3.5 m Number of Lines 2 Mold Mold Weight Measured flow through mold (water) Method Measured flow through mold (oil) Method Webber externally plumbed Nickel, single sided test mold 35.6 Kg 25 liters Differential pressure 28 liters Differential pressure Ambient air temperature for test 18.3 C Temperature probe Atkins Series 384 Digital Amp Meter Fluke 442 Chilled water supply temperature 26.6 C Flow (water) (60 l/minute) Figure 1. Comments: 1. In order to use units from stock, an oil unit with 2x the heating capacity, 2.8x the cooling capacity, and 1.6x the maximum rated flow as compared to the water unit was used. 2. The oil unit s inside diameters for the heating/cooling inlets were 1.8x larger than the inside diameters for the water unit s heating/cooling inlets, thereby allowing for significant gains in flow rates through the mold. Experimental Procedure A nickel shell externally plumbed mold was provided by Weber Manufacturing, Ontario, Canada, for the test. The Weber mold was chosen because of its ability to be heat balanced by controlling the location and number of tubes used to deliver the liquid medium. Temperature readings confirmed that variation across the mold at temperature was within the 3

desired <1 C (with pressurized water). The mold was completely open to the 18 C room temperature and was not insulated. This was believed to represent the worst possible scenario for heat loss. Figure 2. The water unit was taken up to a temperature of 100 C and allowed to soak at that temperature for 5 minutes in order to purge air from the system. The unit was then taken back down to 25 C. 5 additional trials were run to determine the variation in operator performance in capturing temperature data. Acceptable R&R s were achieved. The sixth run was used to plot the data. The oil unit, because they are notoriously hard to rid of air entrapment, was taken to a temperature of 200 C five (5) times before running the actual test. Mold temperature readings were taken using a surface pyrometer on the molding surface at the center of the mold at one minute intervals. The outgoing and returning fluid temperatures from the mold and kw s were read directly from the controller provided on the unit. The data was plotted using 2010 Excel and is shown in the following charts. 4

250 Water TCU vs. Oil TCU Heating Profiles 200 Temperature ( C) 150 100 50 Water TCU Oil TCU Figure 3. 0 0 10 20 30 40 Time (Minutes) Figure 4. 5

Figure 5. Figure 6. 6

Figure 7. 7

2.2 Test parameters for Electric Cartridge heaters versus Pressurized water 1. Use the same mold for both cartridge heaters and pressurized water. 2. Use the same size holes in the mold for both cartridge heaters and pressurized water. 3. Use equipment with similar heating capacities. Goals: 1. Determine mold temperature profiles and energy consumption for both systems. Test Equipment: Item Description Used Single H0.2 6 kw Heating / 41 kw Cooling Hours 100 Hours on unit Power Supply 460 V/60 Hz (3 phase) Flow 60 liters/minute rated flow Heating Lines out to mold 8 mm I.D Line Length 1.5 m Number of Lines 2 Cooling lines into TCU 8 mm I.D Line Length 1.5 m Number of Lines 4 Mold Mold Weight Calculated flow through mold (water) Method Two sided test mold 18 Kg 10 liters Single Temp Heat Transfer Spreadsheet Ambient air temperature for test 21 C Temperature probe Atkins Series 384 Digital Amp Meter Fluke 442 4x 750 Watt 5/16" x 5" cartridge heaters Figure 8. 240V Comments: 1. The mold temperatures for the electric cartridge tests were controlled by comparison of input received from a thermocouple placed in the mold to a temperature set point on the unit s controller. 8

2. The mold temperatures for the water tests were NOT controlled by comparison of input received from a thermocouple placed in the mold to a temperature set point on the unit s controller. The controller on the unit was set to the set point and allowed to monitor the temperature via the incoming water temperature from the mold. 3. In order to allow the same mold to be used for both methods, the mold was not optimized for the water unit. Limited flow due to the small mold passages would only a flow of 9 liters/minute, thus not allowing for much energy to be transferred to the mold. 4. The unit, due to availability, was also the smallest model and thus had substantially less available heating capacity than the cartridge heaters. The unit at 6kW had 1/5 the heating capacity as compared to the electric cartridge heaters. Experimental Procedure Holes were drilled 19mm below both parts centered on a 50mm width on both the stationary and moving halves of the mold. The diameter of these holes was properly sized for a 130mm cartridge heater placed directly below the entire part. These same holes were also used as water channels with the heater cartridges removed. The water was required to turn multiple 90 turns and exited the same end as it entered. Not typically a preferred mold design but allowed for water and cartridge placement directly under the part. A thermocouple was centered between the two plaques and on the centerline of the 130mm length on both mold halves for mold temperature monitoring and for control with the electric heat. 9

Figure 9. Figure 10. 10

The material used for all trials was polyetheretherketone (PEEK). The mold temperature controller was set to 193 C and the temperature reading from the thermocouple was allowed to stabilize with the mold closed. Mold temperature readings were taken using a surface pyrometer on the molding surfaces near the gate, in the part center, and opposite the gate after heat soak after (1) one and (2) two hours of production. After the 2-hour runs for each part were completed, the heater cartridges were removed and the mold was set-up using the pressurized water temperature control unit. The same molding process established for the electric heat was used for the pressurized water. Mold temperature readings were taken just as was performed for the electric heat trials. The consistency of the thermocouple reading was also noted during the molding trials. After the mold reached steady state during the initial heat soak period, the mold was opened to prepare for the trial. During the electrically heated trials, any changes to the steady state condition yielded large temperature swings in the thermocouple reading. The thermocouple reading changed by as much as +/- 13 C in these trials. The thermocouple reading dropped significantly at this time, but did recover to reach steady state at the set point within 10 minutes. The thermocouple temperature of the water heated molds varied by only +/- 5 C and was not greatly influenced by changes in the steady state operating condition. The mold surface temperature was taken at 12 places in the beginning, middle, and end of each (2) two hour run with a surface pyrometer. 11

Heat Type Electric Water Part Time Temperature - C 2.54 mm Thick 5.08 mm Thick 2.54 mm Thick 5.08 mm Thick Soak Temp. 163.3 173.3 129.4 158.3 175.6 130.6 157.2 169.4 149.4 160.6 172.8 150.0 1 Hour 154.4 165.0 142.2 150.6 165.0 147.2 157.2 173.3 158.3 158.3 171.7 156.1 2 Hours 156.1 168.9 142.8 155.6 168.3 142.8 155.6 172.2 160.6 156.1 168.9 157.8 Soak Temp. 158.3 169.4 135.6 155.0 170.0 141.1 154.4 174.4 145.0 159.4 177.2 147.2 1 Hour 153.3 165.0 141.1 156.1 171.1 143.3 156.7 173.9 158.9 164.4 178.9 161.7 2 Hours 155.0 166.7 141.1 158.3 176.1 145.0 155.0 171.1 157.8 163.9 177.2 159.4 Soak Temp. 172.8 175.0 172.2 174.4 176.1 174.4 173.3 174.4 172.8 174.4 175.6 175.6 1 Hour 171.7 176.7 172.2 173.9 175.6 172.2 173.3 176.7 174.4 175.0 176.1 176.7 2 Hours 172.2 177.2 171.7 172.8 177.2 173.3 172.8 177.8 175.0 175.6 176.7 176.1 Soak Temp. 170.0 172.2 172.2 175.0 175.0 174.4 172.2 172.2 171.7 173.9 175.0 174.4 1 Hour 172.8 176.1 172.8 175.0 178.3 173.3 171.7 175.6 173.9 176.7 177.8 177.8 2 Hours 172.8 176.1 172.8 174.4 178.9 173.9 172.2 175.0 174.4 174.4 176.1 175.6 Location A B C D E F G H I J K L Figure 11. 12

Figure 12. Figure 13. 13

Figure 14. A review of the temperature readings indicates that the water heated runs were more consistent over the 2 hours. The average differential in temperature of the same location over the 2 hours in the water heated runs was 1.94 C, while the average differential in temperature of the same location over the 2 hours in the electrically heated runs was 6.7 C. A more concerning point is the difference in temperature over the length of a part. The average temperature differential over the length of one part at the same moment in time is 21.0 C for the electrically heated trials. The average for the water heated trials was only 2.7 C. This large temperature differential over the length of one part in the electrically heated mold could create crystallinity changes within a part. This would create shrinkage differences throughout the part/ resulting in a high degree of molded in stress. This stress could cause part warpage, creep, and physical property differences within the same part. In order to confirm an acceptable level of crystallinity the parts were analyzed with differential scanning calorimetry (DSC) to determine the % crystallinity in the parts. The DSC results confirm the concerns raised by the mold temperature readings during the molding trials and the part dimensional results. The water heated mold produced parts that had consistent and acceptable DSC results throughout the length the part; however, the parts produced from the electrically heated mold had differing crystallinity percentages throughout any single part. 14

3.1 Oil versus Pressurized water 3. RESULTS The tool used showed a larger flow rate for the oil unit. This is as would be expected with a rated flow of 100 liters/hour as compared to 60 for the water unit. Temperature differentials for incoming and outgoing fluid for the oil unit averaged 3.75 C. The water unit average 2 C. Both numbers are within the range of typical values for tools flowing at optimum rates. Based upon this, it is unlikely that either system s efficiency in heat transfer would benefit from additional flow. Not charted in the study is that fact that the oil unit averaged a 2.75 C differential across the tool face while the water was unit under 1 C. 3.2 Electric Cartridge heaters versus Pressurized water The design of the electric heating system can be improved with multiple control zones and faster thermocouple response times. Unfortunately, this would raise energy consumption and equipment costs. By enlarging the tool passages by 40%, the pressurized water system would raise the temperature closer to the set point, reduce the variation across the tool, and consume less energy. Although not tested for in this test, the cooling cycle can be the longer cycle for molding. The water unit offers cooling through the same channels as the heating fluid and can be quickly cycled. The electric cartridge heaters offer no cooling. Cooling systems do exist to compliment electric heating systems but require an additional chiller and channels to be added to the mold. Experience with our customers has shown that the cooling cycle is of major concern and is the longer cycle by a factor of five (5) for thermoplastic composite molding applications. 4.1 Oil versus Pressurized water 4. CONCLUSIONS Even with 2x the heating capacity (24kW vs. 12kW), 2.8x the cooling capacity (116 kw vs. 41kW), and 1.6x higher rated flow (100 Liters/min. vs. 60 Liters/min.), the oil unit was unable to reduce heating and cooling times of the mold as compared to the water unit. The oil unit also consumed 69% more electricity. The most concerning limitation for the oil unit is the large temperature difference between the TCU and the mold. 4.2 Electric Cartridge heaters versus Pressurized water Although the tool was not optimized for the water unit, the unit appears to perform better in every category as compared to electric cartridge heaters. 15