Fire Hose, Nozzles, And Appliances

Similar documents
I. Introduction. 10 minutes

FIRE FIGHTER I CHARACTERISTICS AND FUNCTIONS OF WILDLAND HOSE LAYS TOPIC: TIME FRAME: 1:00. Level II LEVEL OF INSTRUCTION:

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Firefighter Review. Instructor Guide

Operating, Installation, and Maintenance Instructions

123 Industrial Loop Road Paynesville, MN Phone:

Installation Instructions S

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

123 Industrial Loop Road Paynesville, MN Phone:

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

FIRE FIGHTER I CHARACTERISTICS AND FUNCTIONS OF FIRE HOSE AND COUPLINGS TOPIC: TIME FRAME: 1:30. Level II LEVEL OF INSTRUCTION:

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Lebanon Fire Department Lebanon Engine 512 Check Sheet

Watts Pure Water Systems

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

Tri-Homo Style Operation and Maintenance Instructions

Installation guide Nordic mixer taps. Before installing read this guide first

FIRE DEPARTMENT HYDRAULICS

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Gas Bio-digester Information and Construction Manual For Rural Families

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

FAIRBANKS NIJHUIS FIRE PUMPS.

Class A Foam Mixing and Application Equipment

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

San josé OWNER S MANUAL

Series Hose Reels

Installation Instructions

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

SIZING OF WATER PIPING SYSTEM

Rebuild Instructions for and Transmission

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Determine the desired location fixture and center the coaxial cord location to the electrical box.

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

HYDROSTATIC TEST PUMPS

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Cost-effective solutions for all applications.

Stainless Steel Single and Dual Circulation Kits

1402 Hybrid Firefighter I. Course Orientation Guide (Rev 1)

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

Toms River Fire Academy

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

orlando OWNER S MANUAL

Wildland Fire Remote Monitor

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

with installation dynafact boost GAUGE this manual is for use with systems

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

MODEL G300 BRAKE BLEEDER

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

INSTALLATION INSTRUCTIONS BL-8704

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

AMX300 DirectConnect Mixing Valve Kits

Revised April (May) 2015

Pacific Pump and Power

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

INSTALLATION INSTRUCTIONS MK-8704

SunMaxx Solar Filling Station Operating Instructions

Charts (Section XI) Ph. (713) Fax (713) Main PAGE #

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

HYLA NST Cleaning System

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

GENERAL RUBBER LINING PRINCIPLES

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

2100 AD Mirror Elevator Ball Nut Replacement Procedure

MINI ELECTRIC SEWING MACHINE OPERATION MANUAL

Compressed Gas Cylinder Program

Just-Like-Mine! Doll or Stuffed Toy. Car Seat. Instruction Manual. These instructions are for the following Joovy Style # s: 002, 003

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Industrial Strength Rocket Launcher

Installation Instructions / Warranty

Installation Instructions

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

FILLING AND PURGING THE SYSTEM

Engineering Specifications

INSTALLATION INSTRUCTIONS

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

Diesel Fuel Systems. Injection Nozzles

Line to Refrigerator Ice/Water Dispenser

Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use R0514

Title: Best Practices Removal and Installation of Wheel Assembly (Tire Mounted to Rim Assembly) From Container Chassis

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

Transcription:

Fire Hose, Nozzles, And Appliances Class XI March 1, 2008 Morning First Day 20 mins. Part I. Introduction 1

Fire Hydraulics Deals with the study of water at rest and in motion, as related to fire suppression. Deals with properties of energy, pressure, and water flow. Flow Volume of water that is being moved Measured in gallons per minute (gpm) Pressure Amount of energy in a body or stream of water. Measured in pounds per square inch (psi). Required to push water through a hose or to a higher elevation level. Pumps usually provide the pressure. 2

Friction Loss Loss of pressure as water moves through a pipe or hose Loss represents the energy required to push the water. Greater the flow rate in same size hose, the greater the friction loss Smaller hose with same flow, greater friction loss All else equal, loss proportional to distance Elevation Pressure Elevation affects water pressure. Elevated water tanks supply pressure to pipes due to elevation. Difference between nozzle elevation and engine elevation affects pressure. Hoses laid downhill have greater pressure. Hoses laid up stairs will have less pressure. Water Hammer Surge in pressure caused by sudden stop in the flow of water. Shock wave is transmitted back through the hose. Can damage hose, couplings, and plumbing. To prevent, open and close Valves/Nozzles slowly. 3

Part II. Hose 30 mins. Functions of Fire Hoses Attack hose Carries water from engine to the nozzle onto a fire Carries water from engine to master streams Carries water to standpipe and sprinkler systems Supply hose Carries water to the engine May come from a hydrant, another engine or a Static source (thru a Hard Suction) Carries large quantities at lower pressures Sizes of Hose (1 of 3) Small Diameter Hose 1 to 2 inches in diameter Used as attack lines small outdoors fires Each section is usually 50 long 4

Sizes of Hose (2 of 3) Medium Diameter Hose 2 1 2 1 or 3 3 in diameter Used as attack line or supply line Large hand lines usually use 2 1 21 2 inch. Master stream and fire department connections (FDC) often use 3 hose. Each section is usually 50 long. Sizes of Hose (3 of 3) Large Diameter Hose 3 1 21 2 to 6 in diameter Standard diameter is 4 or 5. Standard length is 50 or 100 long. Used as Supply lines only Pressure Testing Attack hose Tested annually Tested to 300 psi. Designed for use up to 275 psi Supply hose Tested annually Tested to 200 psi Designed for use up to 185 psi 5

Hose Construction (1 of 2) Fire hose constructed of inner water- proof liner and one or two outer layers Outer layers Provide strength for high pressures Made from synthetic fibers Provide some abrasion protection Can be single or double jacket hose Can be rubber-jacket hose Hose Construction (2 of 2) Inner waterproof liner Prevents water leakage Provides smooth surface to reduce friction Usually made of synthetic rubber compound thin flexible membrane Attached to outer covering Hose Couplings Used to connect individual lengths of hose Used to connect hose to hydrants, valves, nozzles, and fittings Two types Threaded Non-threaded (Storz-type) type) 6

Threaded Couplings (1 of 2) Used on most hose up to 3 or 4 inch. A set consists of male and female couplings. Male threads are on the outside. Larger lugs on male! Female threads are on the inside. Female couplings swivel. Lugs on the swivel! Fire hose has a male on one end and a female on the other. Threaded Couplings (2 of 2) Higbee indicators indicate proper thread alignment, (for Higbee Cut on the threads). Female couplings have a gasket to prevent leaks and require periodic replacement. Standardized threads. National Standard Installing the swivel gasket Step 1: Fold the new gasket, bringing the thumb and forefinger together, creating two loops. Step 2: Place either of the two loops into the coupling and against the gasket seat. 7

Installing the Swivel Gasket Step 3: Using the thumb, push the remaining unseated portions into the coupling until the entire gasket is properly positioned against the coupling seat. Storz-type type Couplings Has neither male nor female ends Most often used in large diameter hose Couplings are mated face-to to-face and turned clockwise one third turn. Adapters are used to connect to threaded couplings. Skill Drill 16-2 Performing the One-Fire Fighter Foot- Tilt Method of Coupling a Fire Hose Step 1: Place one foot on the hose behind the male coupling. Push down with your foot to tilt the male coupling upward. Step 2: Place one hand behind the female coupling and grasp the hose. 8

Skill Drill 16-2 Performing the One-Fire Fighter Foot- Tilt Method of Coupling a Fire Hose Step 3: Place the other hand on the coupling swivel. Bring the two couplings together and align the Higbee indicators. Rotate the swivel in a clockwise direction to connect the hoses. Skill Drill 16-3 Performing the Two-Fire Fighter Method for Coupling a Fire Hose Step 1: Pick up the male end of the coupling. Grasp it directly behind the coupling and hold it tightly against the body. Step 2 The second fire fighter holds the female coupling firmly with both hands. Skill Drill 16-3 Performing the Two-Fire Fighter Method for Coupling a Fire Hose Step 3: The second fire fighter brings the female coupling to the male coupling. Step 4: The second fire fighter aligns the female coupling with the male coupling. Use the Higbee indicator for easy alignment. 9

Skill Drill 16-3 Performing the Two-Fire Fighter Method for Coupling a Fire Hose Step 5: The second fire fighter turns the female coupling counter clockwise until it clicks. This indicates the threads are aligned. Step 6: Turn the female coupling clockwise to couple the hoses Skill Drill 16-4 Performing the One-Fire Fighter Knee- Press Method of Uncoupling a Fire Hose Step 1: Pick up the connection by the female coupling end Step 2: Turn the connection upright, resting the male coupling on a firm surface. Skill Drill 16-4 Performing the One-Fire Fighter Knee- Press Method of Uncoupling a Fire Hose Step 3: Place a knee on the female coupling and with body weight press down. Turn the female swivel counterclockwise and loosen the coupling. 10

Skill Drill 16-5 Performing the Two-Fire Fighter Stiff-Arm Method Step 1: Two fire fighters face each other and firmly grasp their respective coupling. Step 2: With elbows locked straight, the fire fighters push towards each other. Skill Drill 16-5 Performing the Two-Fire Fighter Stiff-Arm Method Step 3: While pushing towards each other, the fire fighters turn the coupling counterclockwise, loosening the coupling. Skill Drill 16-6 Uncoupling Hose with Spanners Step 1: With the connection on the ground, straddle connection above the female coupling. Step 2: Place one spanner wrench on the female coupling with handle to the left. 11

Skill Drill 16-6 Uncoupling Hose with Spanners Step 3: Place the second spanner wrench on the male coupling with the handle to the right. Step 4: Push both spanner handles down toward the ground, loosening the connection. Attack Hose (1 of 4) 1 1 21 2 and 1 3 43 inch Most common attack line Both use 1 1 2 1 couplings Can be operated by one fire fighter Most common preconnect lengths of 150 to 350 1 1 2 1 generally flows 60-125 gpm 1 3 4 3 generally flows 120-180 180 gpm Attack Hose (2 of 4) 2 1 21 2 hose Used to attack larger fires Generally flows about 250 gpm Takes at least two fire fighters inside a building Weight per 50 section Without water, weighs 30 pounds With water, weighs about 200 pounds Can flow up to 350 gpm 12

Attack Hose (3 of 4) Booster hose Usually carried on a hose reel with 150 to 200 Made of rubber with steel wire to keep shape Can be advanced by one fire fighter 1 line flows 40-50 gpm Used for small outdoor fires and trash dumpsters 1 Attack Hose (4 of 4) Forestry hose Typically 1 or 1 1 21 inch Used for grass, brush, or forestry fires Extremely maneuverable Supply Hose Used to supply attack engine Ranges from 2 1 21 2 to 6 inch, 50 to 100 in length. 4 to 5 inch most common. Large diameter is more efficient than 2 1 21 2 inch Two additional types Soft suction 12 to 25 in length Hard suction 10 to 20 in length 13

Break III. Hose Care,Maintenance,and Inspection 15 mins. Types of Damage to Hose (1 of 4) Mechanical Abrasion from road surfaces Broken glass and sharp objects Abrasion from hose reloaded dirty Vehicles running over it Couplings being damaged Couplings being dragged 14

Types of Damage to Hose (2 of 4) Heat and cold Direct contact from fire Burning coals and embers Hot surfaces such as heating units and exhaust pipes Freezing can rupture inner liner and break outer liner fibers. Lines may be frozen or encased in ice. Types of Damage to Hose (3 of 4) Chemicals Encountered at many incidents, including vehicle fires and accidents Wash hose as soon as possible with approved detergent. Types of Damage to Hose (4 of 4) Mildew Grows on fabrics in warm, moist conditions Feeds on natural fibers and causes the hose to rot Modern hose has synthetic fibers and resists mildew. Rubber-covered hose fibers are protected from mildew. 15

Clean contaminated hose Lay hose out straight & flat. Rinse hose with water. Gently scrub hose, paying attention to soiled areas. Turn hose over. Repeat steps two and three. Rinse hose. Hang hose to dry before storing. Maintaining, and Inspecting Hose Hose inspections Perform quarterly and after each use Hose records Written history of each length of hose 30 mins. IV. Hose Appliances 16

Hose Appliances A hose appliance is any device used in conjunction with a fire hose for the purpose of delivering water. Hose Appliances (1 of 10) Wyes Split the stream into two hose streams Commonly split a 2 1 21 2 hose into two 1 1 21 Gated wyes have two quarter turn valves. Hose Appliances (2 of 10) Water thief Gives the ability to tap into a 2 1/2 hose line with an 1 1/2 Has a 2 1 21 2 inlet, a 2 1 21 2 outlet, and two 1 1 21 outlets 17

Hose Appliances (3 of 10) Siamese Combines two hose lines into one Has two female inlets and one male outlet Often used on engine outlets, master streams, and fire department connections (FDCs) Hose Appliances (4 of 10) Adaptors Used to connect same size hoses but with dissimilar threads Are double-female or double-male Hose Appliances (5 of 10) Reducers Used to attach smaller hoses to larger hoses Commonly used to reduce a 2 1 21 hose to a 1 1 22 hose 18

Hose Appliances (6 of 10) Hose jacket Used to stop a leaking section of hose Consists of a split metal cylinder that fits tightly over the hose Hose Appliances (7 of 10) Hose roller Used to protect a line being hoisted over an edge Prevents chafing and kinking Hose Appliances (8 of 10) Hose clamp Used to temporarily stop the flow of water in a hose: so the hydrant can be opened Hose that has burst 19

Hose Appliances (9 of 10) Master stream devices Large capacity nozzles supplied by two or more lines Include deck guns and portable nozzles Hose Appliances (10 of 10) Valves Control the flow of water through hose or pipe Must be opened and closed slowly Types of Valves (1 of 2) Ball valves Used on nozzles, gated wyes, and engine discharges gates Consist of a ball with a hole in it When hole is in-line with inlet and outlet, water flows. When ball is rotated, flow shuts off. 20

Types of Valves (2 of 2) Gate valves Used on hydrants and sprinklers Rotating spindle causes gate to move across opening Butterfly valves Used on large pump intake Opened by rotating handle one quarter turn 25 mins. V. Hose Rolls Hose Rolls Rolled hose is an efficient way to transport a single section of fire hose. Hose can be rolled in many different ways, depending on how it will be use 21

Types of hose rolls The straight hose roll is a simple and frequently used hose roll. 1 of the couplings forms the core and the other the outside of roll The single donut hose roll is used when the hose will be put into use directly from the rolled state. The hose has both couplings on the outside of the roll. the Appox. middle makes up the core The female coupling overlaps the male, protecting it. Rolling a straight roll Step 1: Lay the length of hose to be rolled flat and straight. Step 2: Begin by folding the male coupling over on top of the hose. Rolling a straight roll Step 3: Roll the hose to the female coupling.. Step 4: Set the hose roll on its side and tap any protruding hose flat with a foot. 22

Performing a Single Donut Roll Step 1: Place the hose flat and in a straight line. Step 2: Locate the midpoint of the hose. Finishing a Single Donut Roll Step 3: From the midpoint, move 5' toward the male coupling end. Start rolling the hose toward the female coupling. Step 4: At the end of the roll, wrap the excess hose of the female end over the male coupling to protect the threads. Twin donut rolls The twin donut hose roll is used primarily to make a small compact roll that can be carried. The self-locking locking twin donut hose roll is similar to the twin donut, with the exception that it forms its own carry loop. 23

Performing the Twin Donut Roll Step 1: Lay the hose flat and in a straight line. Step 2: Bring the male coupling alongside the female coupling. Finishing the Twin Donut Roll Step 3: Fold the far end over and roll toward the couplings, creating a double roll. Step 4: The roll can be carried by hand, rope, or strap. Performing a Self-Locking Twin Donut Step 1: Lay the hose flat and bring the coupling alongside each other. Step 2: Move one side of the hose over the other creating a loop. This loop creates the carrying shoulder loop. 24

Performing a Self-Locking Twin Donut Step 3: Bring the loop back toward the couplings to the point where the hose crosses. Step 4: From the point where the hose crosses, begin to roll the hose toward the couplings with the loop as its center. This creates a loop on each side of the roll. Performing a Self-Locking Twin Donut Step 5: On completion of the rolling, position the couplings on the top of the rolls. Step 6: Position the loops so one is larger than the other. Then pass the larger loop over the couplings and through the smaller loop. Stop 25