Photoelectric Beam Detector

Similar documents
Tina 2A/B Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit

Wireless Indoor/ Outdoor Thermometer

Mini Power Bank and Charger

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Infrared Viewers. Manual

High definition day/night

Ultrasonic Distance Meter. Operation Manual

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Installation and Operation Guide for PD4100 Series Power Control Centers

16/32 Channel 1U Rack Mount CCTV Power Supply

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

This product has the equivalent gain performance with the 14 element Yagi antenna.

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

User and Installation Guide

12-Volt 10-Amp Regulated Power Supply

900 MHz Lightweight Wireless Stereo Headphones

Inwall 4 Input / 4 Output Module

COLOR TFT LCD MONITOR. User Manual

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

LDG DTS-6/6R Desktop Coaxial Switch / Remote

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Owner s Manual & Safety Instructions

Hi-Speed USB Port Hub Connect up to 7 Hi-Speed USB 2.0 or USB 1.1 devices

Installation Instructions

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Installation and Operation Guide for PD4000 Series Power Control Center

USB Scrolling Optical Mini Mouse

FIRERAY 2000 Installation Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Leak Detection System

Single Channel Loop Detector

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

Signal Manager Installation and Operation Manual

Model SRMD Setra Remote Monitoring Display

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

WMT-3000 Wireless Transmitter. Owner s Manual

MS900AC-B-LS User Information

i410/i1010 AC/DC Current Clamp

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

FLEX by 3M Light Module System

Single Phase Soft Starter

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

Installation and Operation Guide for PD5100 Automatic Transfer Switch

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

4 Port Hub User Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

POWER GEAR SLIDE OUT MANUAL

DCX300 - DCX400 - DCX600

3 WATT LED SPOTLIGHT Model No. SLM

Advantium 2 Plus Alarm

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

W 36: Mastering complex tasks reliably

TIG INVERTER INSTRUCTION MANUAL

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Passive Infrared Motion Detector 5420/90. Installation Instructions

How To Use A Cdm250 Digital Multimeter

Digital Watchdog Infinity Camera B1367WTIR650

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Load Cell Amplifier Module. Instruction Manual LCA

LDG DTS-4/4R Desktop Coaxial Switch / Remote

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

12 Volt 30 Amp Digital Solar Charge Controller

Inwall Room Temperature Unit

Infrarot-Bewegungsmelder IP44

Operating Manual UWAPS-TINY Series

Operating Instructions. UL325 Compliant Non-monitored

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Smile 11 AS-i Emergency stop with safe AS-i input node

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Weather Radio Alarm Clock

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Global Water Instrumentation, Inc.

2014 EBR MOTORCYCLE LIMITED WARRANTY

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

LCD5500Z / PKP-LCD v3.x Installation Instructions

Adjustment functions for both span and shift have been incorporated

Security Auto Dialer. Owner s Manual. Please read before using this equipment.

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

MULTI-BEAM LS10 Light Screen System

USB 2.0 Hi-Speed 4-Port Hub User Manual

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

, User s Manual

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

CA-125 Owner's Manual

Single Port T1/E1 Tap

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Transcription:

EL-PB60S Features EL-PB60S Photoelectric Beam Detector ( 60M ) - Wide angle adjustment - External light protection - Protection against frost/dew, Guaranteed quality of front cover - High convenience for installation and wiring - Safety Approval: CE EL-PB60S Specification - Protection range: Outdoor : 60m Indoor : 120m - Detection method: Simultaneous breaking of 2 beams - Infrared beam: Double modulation pulsed beams by LED - Response time: 50 ~ 700mS - Supply voltage: DC 10.8 ~ 25VDC(Non-polarity) - Current: Max. 57mA - LED: Tx : Power(Green LED), Rx :Sensitivity good (Green LED), When an alarm is initiated (Red LED) - Alarm output: Dry contact relay output form C, Contact action : Interruption time +delay time(1~3 sec), Contact capacity : 30V(AC/DC) 1A or Less - Tamper output: Dry contact relay output form N.C(Rx only), Contact action : Activated when cover is detached, Contact capacity : 30V (AC/DC) 1A or Less - Temperature: -20 ~ 60 - Beam Adjustment: Horizontal : 180 (±90 ), Vertical : 20 (±10 ) - Mounting site: Indoor/Outdoor - Material: Cover : PC resin, Base : ABS resin - Dimension: 63 x 163 x 75mm (W x H x D) - Weight: Rx : 330g, Tx : 315g - Function: Monitor jack output, Frost proof cover - IP rating: IP 44

User Guide: Installation Instruction We appreciate your purchase of our photoelectric beam detector. This detector will provide long and dependable service when properly installed. Please read this Instruction Manual carefully for correct and effective use. Please Note: This detector is designed to detect intrusion and to initiate an alarm; it is not a burglarpreventing device. Maker is not responsible for damage, injury or losses caused by accident, theft, Acts of God (Including inductive surge by lightening), abuse, misuse, abnormal usage, faulty installation or improper maintenance. Notice - The photoelectric beam detector is damaged if it is connected to an AC power supply. - The photoelectric beam detector may be damaged if the applied voltage exceeds the rated specification. - Do not remodel the detector or replace any parts. - Avoid wet or damp place. - Install inside of visibility range or possible distance can see a brake light of motor vehicle when it is used in the place fog occur frequently. 1. Cautions On installatio

2. Part Description 3. Response Time 4. Expansion of Beam and Position of Installation

5. Installation 6. Channel Setting This function is used for purpose of preventing cross-talk or bypass of beams which may occur in line protection or 2-stacked protection. Set beam channel.

7. Optical Alignment Read voltage from monitor jack with volt-meter (digital) to confirm optical alignment and to obtain the highest reliability. Supply power with cover detached. Set Transmitter lens to recover lens by the view finder. Look through view finder on both side and line-up optics horizontally and vertically until the opposite unit is visible. (Using the adjuster, the lens can move horizontally (±90 ) and vertically (±10 ) allowing the unit to work in all the directions). The opposite Transmitter or Receiver should appear on the view finder of inside middle mirror. Adjust the Transmitter's horizontally and vertically to get highest voltage reading. Adjust the Receiver's horizontally and vertically to get highest voltage reading. 8. Terminal Arrangement

9. Troubleshooting Symptom Possible cause Remedy LED does not light Alarm LED does not light when the beam is broken Alarm LED continues to light Intermittent alarms 10. Dimensions - No power supply - Turn on the power - Bad wiring connection or broken wire, short - Check wiring - No power supply - Turn on the power - Bad wiring connection or broken wire, short - Check wiring - Beam is reflected on another object and sent - Remove the reflecting object or into the receiver change beam direction - Two beams are not broken simultaneously - Break two beams simultaneously - Beam alignment is out - Check and adjust again - Shading object between Tx. and Rx. - Remove the shading object - Optics of unit are solied - Clean the optics with soft cloth - Bad wiring connection - Check again - change of supply voltage - Stabilize supply voltage - Shading object between Tx. and Rx. - Remove the shading object - A large electric noise source, such as power - Change the place for installation machine, is located nearby Tx. and Rx. - Unstable installation of Tx. and Rx. - Stabilize - Solied optics of Tx. and Rx. - Clean the optics with a soft cloth - Improper alignment - Check and adjust again - Small animals may pass through the 2 beams - Set the response time longer Limited Warranty Tomura Products are warranted to be free from detect in material and workmanship for 12 months from original date o shipment. Our warranty does not cover damage or failure caused by Acts of God, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repair other than those provided by tomura All implied warranties with respect to Tomura including implied warranties for merchantability and implied warranties for fitness are limited in duration to 12 months from original date of shipment. During the warranty period Tomura will repair or replace, at its sole option, free of charge, any defective parts returned prepaid. Please provide the model number of product, original date of shipment and nature of difficulty being experienced. There will render for product repairs made after our warranty period has expired.