Fast combined temperature, pressure, and heat flux sensors for rough environments

Similar documents
Guide to adhesively mounting accelerometers

Cryogenic Performance of Millitech Model FBI-22 Waveguide Isolator.

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Low Frequency Velocity Sensor

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

COMBIMASS. Technical Data COMBIMASS eco-bio +

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Why a torque measuring system?

MGO Insulated Thermocouples Index

9000 Series Accelerometers Specifications

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Thermal diffusivity and conductivity - an introduction to theory and practice

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Thermal Flow Sensor Die

Products for Effective Asset Management

Digital inductive conductivity transmitter

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

psens Pressure Measurement

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

How To Use A Flowmeter

Mounting Instructions for SP4 Power Modules

Select Radiators Installation Guide

Department of Aerospace Engineering Indian Institute of Science Bangalore

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Highly efficient flue gas analyzer

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

Product Specification

ELECTRICAL CHARACTERISATION OF SEMI-RIGID COAXIAL CABLES WITH SMA AND K CONNECTORS. Carmen Diez Rafael García Juan Daniel Gallego.

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

HYDROGRAPHIC ECHOSOUNDER FOR SOUNDING INLAND WATERS ANDRZEJ JEDEL, LECH KILIAN, JACEK MARSZAL, ZAWISZA OSTROWSKI, ZBIGNIEW WOJAN, KRZYSZTOF ZACHARIASZ

For the modifications listed below, the Qualification Approval tests in IEC and IEC 61646, shall be used as a guideline by the assessor:

SC100 Series Seismic Vibration Sensors. The Best Way to Protect High-Risk Commercial Assets

Good Boards = Results

EasyTrack 2 Accessories List

Typical Aluminum GFM Mass Flow Meter

Magnetic proximity switches

Portable Hardness Tester

On-line Machine Condition Monitoring [The CMS System]

Heikki Turtiainen *, Pauli Nylander and Pekka Puura Vaisala Oyj, Helsinki, Finland. Risto Hölttä Vaisala Inc, Boulder, Colorado

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Foxboro Evo Process Automation System

Inductive sensor NI10-M18-Y1X-H1141

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Velomitor Piezo-velocity Sensor

A/C refrigerant system, overview

-Encoder with end or hollow shaft ø10-15 mm. hollow shaft ø12 mm -Resolution max. 32 ppr. -Resolution max ppr -Magnetic sensing

AC and Pulse Film Foil Capacitors KP Radial Potted Type

The Do s and Don ts of Pressure Transducers

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

- 1 - Eddy Current. Eddy current distance and displacement transducer

Speed sensor MiniCoder GEL 247

HM1500LF Relative Humidity Module

High-ohmic/high-voltage resistors

UNDERSTANDING CENTRAL HEATING SYSTEMS

75 Ω Transmission System

Speed Sensors Line Guide

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities

Proximity Transmitters and Seismic Vibration Transmitters

HOT BAR REFLOW SOLDERING FUNDAMENTALS. A high quality Selective Soldering Technology

Engineered Solutions

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Reaction Torque Sensor

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Harness expertise & quality assurance

Guideline for Control Surveys by Differential Levelling

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

LOW LOSS CABLE PAG. 1

Guideline Laser Series

MXD7202G/H/M/N. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Digital Outputs

NEW. EVEN MORE data acquisition and test stand automation

SMA Interface Mating Dimensions (Per MIL-STD-348)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

APPLICATION NOTE. Ear Simulator for Telephonometry. Use of Wideband Ear Simulator Type 4195

Eddy-current testing - Non-destructive testing for flaw detection of metals, coatings and carbon fibres

MOUNTING AND OPERATING INSTRUCTIONS

USB-500 Series Stand-Alone, Low-Cost Data Loggers

The Tesla Roadster battery pack is comprised of about 6800 of these cells, and the entire pack has a mass of about 450kg.

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

TRAM LINE SWITCH POINT HEATING

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

RESPONSE TIME INDEX OF SPRINKLERS

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

British Standard Underground Hydrant Range

Cable Trays Technical Instructions & Specifications

Continuous Thermal Monitoring to Minimise Slag Carry-Over in Steel Production. Slag Detection System

TGP-751 TGP-651. ThermoGenerator-Package (TGP) Thin Film Thermogenerator inside standard package. Preliminary Datasheet

3-Component Measuring System

Transcription:

Fast combined temperature, pressure, and heat flux sensors for rough environments Category: Sensors & Measuring Techniques Reference: TDO0080 Broker Company Name: D`Appolonia Broker Name: Tanya Scalia Telephone: +39 06 59450300 Email: tanya.scalia@dappolonia.it Abstract: Accurate measurement of pressure, temperature, and heat flux at high frequency is often required in a harsh environment, such those found in rocket launchers, atmospheric entry or on-ground rocket and conventional engine tests. Alta has developed a general, small sensor unit layout (typical sensing diameter between 10 and 30 mm) that can measure pressure, temperature and retrieve heat flux on a surface. The sensor unit is provided with fast commercial sensors flush mounted; the sensor choice can be tailored to the customer needs. Description: Small size metallic sensor units (typically 15-30 mm in diameter) are provided with high-frequency temperature and/or pressure sensors to be flush mounted on the measurement surface. Pressure is directly measured from the embedded sensors, with the possibility of measurement down to 10 Pa levels. Temperature is measured through coaxial thermocouples and heat flux is derived from the post-processing software. During calibration activities, uncertainty in pressure measurement is below 0.5%, below 2% for convective-conductive heat flux and below 5% for radiative heat flux. The architecture is very robust and was qualified for space including severe launch conditions and atmospheric re-entry. In general, the units are suitable for strong vibrational, hot, and/or humid environments. The sensor units are provided along with dedicated post-processing software that can be used to retrieve the instantaneous heat flux from the measured temperature using each probe s individual calibration. Units operating with a single temperature sensor can be provided and calibrated to retrieve heat flux from a single temperature measurement. Dedicated amplification and signal conditioning electronics can be provided with bandwidth up to 20 khz. Innovations and advantages of the offer: The technology is more flexible and rugged than straight application of commercial items, that often are not available for the user requested conditions. It is qualified for much harsher than typical sensor environments providing cheap, robust and accurate high-frequency results. The dedicated calibration of each unit allows a high degree of customization with respect to the application requirements in terms of dimensions, sensors, conditions Further Information: The sensor unit layout is defined taking into account two different requirements:

1. The unit has to function as a calorimeter, so its dimensions should be uniform and sufficiently bigger than the central flush mounted thermocouple to allow the correct numerical reconstruction of heat flux during the post-processing. 2. The unit has to allow the placement of different sensors, in particular pressure sensors, that could be much bigger and survive vibrations, shocks etc. The suggested minimum diameter resulting from the constraint in the first bullet is around 10-15 mm. The minimum height is around 25 mm. Fig. 1 Example of unit: EXPERT Streamlined Sensor Unit (2 thermocouples, 1 pressure sensor) Fig. 2 Example of unit: EXPERT baseline Sensor Unit (1 thermocouples, 2 pressure sensors)

Fig. 3 Example of unit: heat flux units used for VEGA Zefiro 9 solid propellant thruster Fig. 4 Example of calibration run: temperature and surface heat flux history (left) internal temperature history (right)

Fig. 5 Example of calibration runs: long and short duration heat pulses Fig. 6 Examples of higher temperature tests. The commercial sensors typically used to manufacture the sensor units are Kulite pressure sensors (up to 140 bar compensated up to 232 C), and MEDTHERM coaxial thermocouples (response time in the microseconds range). The unit is manufactured out of stainless steel or copper; if needed sealing is performed with high temperature glues or potting. The proposed sensors have successfully achieved all the qualification test levels.

Application: The sensor are meant to be used in harsh environment including high vibration (>1400 g), high temperature (> 1300 K), humid environments. The typical bandwidth is in the range of several tens of khz with dedicated signal conditioning electronics with certified bandwidth of 20 khz. Current domain of application has been rocket launchers, atmospheric re-entry or on-ground rocket and conventional engine tests. Potential further domains of applications can be all those where measurement of pressure, temperature and heat flux with bandwidth up to at least 20 khz are needed in harsh environments. This technology description was downloaded from www.esa-tec.eu