MEASUREMENT OF HEARING THREHOLD USING AN AUDIOMETER

Similar documents
PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

Audiometry and Hearing Loss Examples

1000+ AUDIOMETER OPERATING INSTRUCTIONS

PURE TONE AUDIOMETER

Your Hearing ILLUMINATED

Dr. Abdel Aziz Hussein Lecturer of Physiology Mansoura Faculty of Medicine

Pure Tone Hearing Screening in Schools: Revised Notes on Main Video. IMPORTANT: A hearing screening does not diagnose a hearing loss.

Operating Instructions MAICO MA 52

MA 25 Operating Manual

Hearing Tests And Your Child

DAILY BIOLOGIC CHECK OF AUDIOMETERS

Manual Pure-Tone Threshold Audiometry

Hearing Tests And Your Child

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

MA 41 Operating Instructions

HEARING SCREENING FOR CHILDREN

S-822. Noise and Hearing Conservation RISK MANAGEMENT

MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

HEARING SCREENING: PURE TONE AUDIOMETRY

Understanding Hearing Loss

HEARING MEASUREMENT 8.1. INTRODUCTION (RATIONALE FOR AUDIOMETRY)

Operating Instructions MA 27

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

The NAL Percentage Loss of Hearing Scale

Practice Standards for Hearing Service Providers

Estimation of Loudness by Zwicker's Method

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

Veterans UK Leaflet 10. Notes about War Pension claims for deafness

Guideline for Hearing Conservation and Noise Control

California State University, Fresno Department of Communicative Disorders and Deaf Studies CDDS 128. Observations in Audiology

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

SPEECH Biswajeet Sarangi, B.Sc.(Audiology & speech Language pathology)

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

Welcome to the United States Patent and TradeMark Office

HEARING SCREENING (May 2006)

Stanford University. Hearing Conservation Program

The Design and Implementation of Multimedia Software

Recommended Procedure. Pure-tone air-conduction and bone-conduction threshold audiometry with and without masking

PRODUCT SHEET OUT1 SPECIFICATIONS

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

GUIDELINES ON THE ACOUSTICS OF SOUND FIELD AUDIOMETRY IN CLINICAL AUDIOLOGICAL APPLICATIONS

Hearing Screening Protocol for School Aged Children

Hearing and Deafness 1. Anatomy & physiology

Acoustic Terms, Definitions and General Information

Spectrum Level and Band Level

Features, Benefits, and Operation

WIRELESS EARPHONES with ACTIVE NOISE CANCELLING Thank you for purchasing PHIATON BT 100 NC

Trigonometric functions and sound

Hearing Loss in Geriatric Primary Care Mary Ann Forciea MD Josh Uy MD

Summary Our science project is an investigation into the varying levels of damage that different types of earphones and mp3 players cause to hearing.

JBL CINEMA BASE. Home Cinema 2.2 all-in-one soundbase for television OWNER S MANUAL

Main features * : Internal database > 1000 tests. Suprathreshold tests. High frequency. Musical frequencies. Automatic masking.

Western University. Hearing Protection Program. Prepared by: Occupational Health and Safety

360 Programming Guide

Aircraft cabin noise synthesis for noise subjective analysis

Getting Started Kei Te Timata

Step-by-Step RECD Guide

5th Congress of Alps-Adria Acoustics Association NOISE-INDUCED HEARING LOSS

The Sonometer The Resonant String and Timbre Change after plucking

NEW YORK STATE MEDICAID PROGRAM HEARING AID PRIOR APPROVAL GUIDELINES

Noise and Hearing Protection

REGULATIONS FOR THE DEGREE OF MASTER OF SCIENCE IN AUDIOLOGY (MSc[Audiology])

Tuning Subwoofers - Calibrating Subwoofers

Once your baby has good head control and can turn towards something interesting, a more advanced behavioural procedure can be used.

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

every person, and if not, what the average frequency ranges are. Additionally, I

The Accuracy of 0 db HL as an Assumption of Normal Hearing

Guidelines for Manual Pure-Tone Threshold Audiometry

Section 4. Hearing loss and hearing tests

OAK GROVE SCHOOL DISTRICT. Hearing Conservation Program

Who are you? Six Components of Hearing Conservation Program. Hearing is Precious!

instruction guide Version 2.2 Table of contents

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

INTERFERENCE OF SOUND WAVES

Sound Pressure Measurement

K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002

AP Psychology ~ Ms. Justice

GSnap Manual. Welcome to GSnap. Installation. Hints

Audio Examination. Place of Exam:

DeNoiser Plug-In. for USER S MANUAL

GSI AUDIOSTAR PRO. Free Call: CLINICAL TWO-CHANNEL AUDIOMETER. Australian Distributer:

Direct and Reflected: Understanding the Truth with Y-S 3

Manual Analysis Software AFD 1201

The Disability Tax Credit Certificate Tip sheet for Audiologists

Product Line for Hearing Screening & Diagnostics

Hearing Test Results from 2009 Audio Engineering Society Convention Testing funded by Shure

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Everybody has the right to

Hearing Disability Assessment

Audible Alarm Basics Everything you wanted to know, but were afraid to ask by Dan O Brien, Sales Engineer, Mallory Sonalert Products, Inc.

Introduction Noise and Occupational Hearing Loss

Operating Instructions Detective Audiometer

Guideline for diagnosing occupational noise-induced hearing loss. Part 3: Audiometric standards

Noise. CIH Review PDC March 2012

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Transcription:

MEASUREMENT OF HEARING THREHOLD USING AN AUDIOMETER Theoretical introduction: A precise assessment of hearing function is a frequently performed procedure in otorinolaryngology. It is part of the entrance medical evaluation for professions in which normal hearing function essential. It is also frequently performed when assessing work-related health damages. The audiometric examination is the most precise available assessment of hearing function. Audiometers are devices that generate audible tones with specified pitch and intensity level. The intensity level L is measured in the units of decibel (db), with the following relation to the intensity I (measured in units of W/m 2 ): Here I0 = 10-12 W/m 2, which is the lowest audible intensity (for a healthy young subject) of a tone with frequency 1 000 Hz. Audiometry determines the hearing threshold (i.e., the lowest audible intensity level) for pure tones of frequency between 125 Hz and 8 000 Hz (in octave increments). Audiometers are standard equipment at ORL clinics and audiometric centers. They are used in the so-called quiet chambers with good sound insulation from the surroundings. The left and right ear is examined separately. To prevent the non-examined ear from detecting the tone played to the examined ear, the audiometer outputs a masking noise to the non-examined ear. This is necessary when the examined ear has a strong hearing deficit compared to the non-examined ear. The masking noise is generated by mixing a range of frequencies. During the audiometric measurement, we fix the frequency and gradually increase the intensity from very low (inaudible) values. When the examined subject can first hear the tone, he/she signals this by pressing the response button. This determines the threshold intensity for the given frequency. The intensity level is calibrated in decibels, and can be increased in increments of 2 or 5 db. The norm (for a young healthy subject) corresponds to 0 db. If the examined subject has better hearing than the norm, it is necessary to start with intensities below 0 db (most audiometers permit to set the intensity as low as -20 db). The sound wave is transmitted to the subject either by a headphone (air conduction) or by a vibrating bar placed on the processus mastoideus (bone conduction). The bone conduction stimulation bypasses the outer and the middle ear, and directly activates the inner ear.,

The audiogram is a graphical representation of the measured threshold values for air conduction, or for both air and bone conduction. In the graph below, the left panel shows the audiogram for a subject with hearing deficit, while the right panel is for a subject with normal hearing. Audiogram interpretation: Types of hearing loss: normal hearing thresholds below 15 db, hearing loss above 15 db sensorineural hearing loss - when the loss is equal for air and bone conduction conductive hearing loss the loss is seen in air conduction but not in bone conduction Degree of hearing loss: 1. Slight hearing loss = 25 40 db, 2. Moderate hearing loss = 41 65 db, 3. Heavy hearing loss = 66 90 db, 4. Heavy loss with deafness = over 90 db.

Description of apparatus used in the lab: The audiometer Maico MA 50 generates pure tones for either air or bone conduction. The pitch of the tone is selected by choosing the frequency in the range 125 Hz - 8 khz, with the following selectable frequencies: 125 Hz, 250 Hz, 500 Hz, 750 Hz, 1 khz, 1,5 khz, 2 khz, 3 khz, 4 khz, 6 khz, 8 khz. The intensity level is regulated in the range of -10 to 110 db in 5 db increments. Fig.1 Audiometer and a sounproofed chamber for audiometric examination. Equipment: 1) Audiometer MA 50 2) Headphones 3) Bone vibrator 4) Response button 5) Blank audiogram

Fig. 2 - Audiometer MA 50 Task: Determine the hearing thresholds for air conduction and for bone conduction, in the frequency range 125 Hz 8 000 Hz. Procedure: Please be careful when handling the audiometer. In particular, do not pull on the cables connected to the earphones and the bone vibrator, and do not drop the equipment. 1) Divide into groups of 2 or 3 students. Each groups performs separate measurements. 2) 1 or 2 students manipulate the audiometer and record into the provided blank audiogram the values of the hearing thresholds of the examined student. 3) Use separate symbols for the left and right ear. The legend for symbols is shown in the right margin of the provided audiogram.

Scheme 1 - Controls on the audiometer 4) Switch on the audiometer by pressing the button on the right side. 5) The default setting after switching on is: air conduction, frequency 1000 Hz, 30 db tone on right ear, -10 db noise on left ear. 6) Press the button STIM MODE (uninterrupted unmodulated tone) and set the noise level to 15 db. Then press TRACK (the noise level will then be automatically adjusted when the tone intensity level is changed). 7) The examined student, sitting about 1 m from the audiometer, puts on the headphones red on right ear, blue on left ear. He/she holds the response button (when pressed, the light in the upper middle part of the audiometer is activated). The light signals to the examiner that the examined subject has just heard the the lowest audible intensity level. 8) On the right ear, measure the threshold intensity levels (set by the wheel on your right) for the frequencies 1000Hz, 750Hz, 500 Hz, 250 Hz, 125 Hz and then 1 500Hz, 2 khz, 3kHz, 4 khz, 6kHz, 8 khz (set by the buttons +/- Hz on the left under display). Draw the measured values in the audiogram. Proceed similarly for the left ear (after switching the button at bottom left to L). 9) Next, determine the hearing loss for bone conduction. Press the button with symbol BC. Press R (right ear). Place the vibrator on the processus mastoideus of the temporal bone of the right ear (see Fig. 3). Do not remove the headhones; on the left side keep the earphone on the ear, on the right side place the earphone on the cheekbone. Switch off TRACK, set noise level to 15 db, then switch TRACK back on. Keep STIM MODE on. 10) Determine the hearing threshold for frequencies 1000Hz, 500 Hz, 250 Hz and then 1 500Hz, 2 khz, 3kHZ, 4 khz, 6kHz. Plot the obtained values in the

audiogram. Press L, switch sides for the vibrator and headphones, record the values for left ear and plot in audiogram. 11) Record the results of all measurements into the lab protocol. Fig. 3 Placement of bone vibrator. Test questions: 1. What is the audible field? 2. Describe the sound conduction and detection in the human ear. 3. What is the range of frequencies audible to humans? 4. What is the loudness (measured in units of phon)? How would you determine the loudness in phons of a tone of given frequency and intensity level?