Suitable for: Large labs 400-200 Samples per day including standards Available in Natural Gas Liquefied Petroleum Gas OIL (diesel) FURNACE & ASSAY S U P P L I E S 50/84 Place Fusion Furnace Crucibles: 50 x 50gram 50 x 65gram 84 x 30gram 84 x 40gram 84x 55 gram Working Area 650mm Deep 220mm Wide 350mm High Pair With 00 or 68 Place Cupellation Furnace Electric 00 Place Cupellation Furnace Tel: +6 8 9399 9299 E-mail: info@fandasupplies.com Website: fandasupplies.com/
200 mm 985 mm Construction Base construction uses high-quality 00x 00 RHS. 980 mm Furnace body construction is durable 5mm laser-cut plate High quality refractory brick and insulation Bolt holes in base plates of all 4 legs for individual adjustment on uneven surfaces Pneumatic door controls with foot pedal controller available with an optional hand valve controller 490 mm AVERAGE BURNER EQUIPMENT DEPTH Working Height 935mm 2070mm Shipping ISPM 5 Heat treated export crates Length 2090mm 755mm Width Height Weight 690mm 2080mm 2200KG 595 mm ELECTRICAL BOX 250 mm Please note you will require a minimum of metre clearance around the furnace. * Dimensions are approximate only and may vary slightly with each furnace.
50/84 Place Fusion Furnace Natural Gas 240V FAS-20-NG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Gas Consumption Natural Gas or LPG 540MJ Per Hour 3.5 KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 3.5KPA 7KPA Low Gas Pressure Detection Air Pressure Switch CPI Switch
50/84 Place Fusion Furnace Natural Gas/LPG 0V- FAS-20-NGLPG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 0V Gas Consumption Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure.5 Natural Gas or LPG 540MJ Per Hour 3.5 KPA 3.5KPA 7KPA Low Gas Pressure Detection High Gas Pressure Detection (Optional) Air Pressure Switch CPI Switch Over Temperature Controller (Optional)
50/84 Place Fusion Furnace LPG - FAS-20-LPG This furnace has a dual Long Pattern Inspirator burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. Please note: this type of equipment is not suitable for altitudes above 000 metres and may not be suitable for some countries due to gas regulations. Refer to FAS-0-NG and FAS-0-NGLPG for LPG fuelled system suitable for high altitudes and accepted globally. 240V Gas Consumption LPG (Propane) 540MJ Per Hour 40KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 0KPA 40KPA Door Switch
50/84 Place Fusion Furnace Oil (Diesel) - FAS-20-OIL This furnace has a fan forced dual burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Pilot Burner Fuel Oil/Diesel LPG Small Gas Bottle High Fire Low Fire 80 PSI 70PSI Air Pressure Switch