50/84 Place Fusion Furnace

Similar documents
SIOUX HYBRID WATER HEATER

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

G234X-55 Conventional Gas Boiler

HEAVY DUTY STORAGE GAS

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

Heating with wood chips and pellets

Boiler Preparation, Start-Up and Shutdown

OilonChooser Operating Instructions

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

ETC -SV. Class 0 oil-free compressed air through catalysis

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

Please keep this manual for f uture reference.

Air Conditioning Sign-Off Sheet

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Installation Instructions

Heating and cooling a home in Australia amounts to around

Endless Hot Water 24/7

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Gas Fireplaces FEATURING

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Gas Detection for Refining. HA University

UDSA - UDSBD unit heater

Your safety and the safety of others are very important.

301.7D. Mini Hydraulic Excavator

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Commercial Gas Water Heaters


Product Overview Benefits

Rainwater Harvesting

Instantaneous gas water heater

San josé OWNER S MANUAL

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire

Cooling Capacity CFM in. w.c. (125 Pa)

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Practical Examples of Heat Regenerative System at Steelmaking Works

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Commercial Gas Furnace Upflow

Midland Combustion Electric Line Heaters with Integral Panels

Donut Robot Mark I Mark VI

AMS 120. EFT Guest Card Terminal & Refund unit

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

Commercial Gas Water Heaters

N o.11. engineering BOX OVENS OVENS OVENS OVENS OVENS. The definitive guide to industrial ovens MINI WALK IN EXTRA HEIGHT TUNNEL CONVEYOR.

SIZING AND CAPACITIES OF GAS PIPING

Flash Point. Test Methods

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

Gas Water Heater. Coming into Its Own, Finally COMPARATIVE TEST

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

mobile pipeline Bulk transportation and storage of energy gases

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Technical Specification. Generating Set with Waukesha engine burning natural gas

COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Automation's Modular Containerized Datacenter Solutions

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

G670 Intermittent Pilot Ignition Controls

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Inventory Management Guide

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

MODELS BTR(C)120 THRU 500A

Autoclave Design Considerations

Access Server Rack Cabinet Compatibility Guide

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Originators of the Flexible Water Tube design

Gas and Oil Fired Space Heating

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

SIZING AND CAPACITIES OF GAS PIPING

DUAL FUEL BURNERS GAS/HEAVY OIL

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

C18 ACERT Fire Pump Tier bkw/ rpm

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

GenStore Archive Cabinet

FORKLIFT STABILITY. MATERIAL HANDING AND ROBOTICS I. Practical course. Dávid HURI office door number: 324/6

Automatic Back-Flushing Filter AutoFilt RF9.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

EM REMOVE NO. 2 MANIFOLD STAY (a) Remove the bolt, nut and stay.

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

PREPIPED LIQUID FUEL MANIFOLDS PLPM

INSTANTANEOUS GAS FIRED

Split units TH with hermetic compressors

Transcription:

Suitable for: Large labs 400-200 Samples per day including standards Available in Natural Gas Liquefied Petroleum Gas OIL (diesel) FURNACE & ASSAY S U P P L I E S 50/84 Place Fusion Furnace Crucibles: 50 x 50gram 50 x 65gram 84 x 30gram 84 x 40gram 84x 55 gram Working Area 650mm Deep 220mm Wide 350mm High Pair With 00 or 68 Place Cupellation Furnace Electric 00 Place Cupellation Furnace Tel: +6 8 9399 9299 E-mail: info@fandasupplies.com Website: fandasupplies.com/

200 mm 985 mm Construction Base construction uses high-quality 00x 00 RHS. 980 mm Furnace body construction is durable 5mm laser-cut plate High quality refractory brick and insulation Bolt holes in base plates of all 4 legs for individual adjustment on uneven surfaces Pneumatic door controls with foot pedal controller available with an optional hand valve controller 490 mm AVERAGE BURNER EQUIPMENT DEPTH Working Height 935mm 2070mm Shipping ISPM 5 Heat treated export crates Length 2090mm 755mm Width Height Weight 690mm 2080mm 2200KG 595 mm ELECTRICAL BOX 250 mm Please note you will require a minimum of metre clearance around the furnace. * Dimensions are approximate only and may vary slightly with each furnace.

50/84 Place Fusion Furnace Natural Gas 240V FAS-20-NG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Gas Consumption Natural Gas or LPG 540MJ Per Hour 3.5 KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 3.5KPA 7KPA Low Gas Pressure Detection Air Pressure Switch CPI Switch

50/84 Place Fusion Furnace Natural Gas/LPG 0V- FAS-20-NGLPG This furnace has a fan forced dual burner system, with an automatic ignition system. It can be swapped between NG and LPG (propane) to suit varying site requirements, with just a few simple adjustments performed on-site involving a minimum of downtime and associated costs. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 0V Gas Consumption Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure.5 Natural Gas or LPG 540MJ Per Hour 3.5 KPA 3.5KPA 7KPA Low Gas Pressure Detection High Gas Pressure Detection (Optional) Air Pressure Switch CPI Switch Over Temperature Controller (Optional)

50/84 Place Fusion Furnace LPG - FAS-20-LPG This furnace has a dual Long Pattern Inspirator burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. Please note: this type of equipment is not suitable for altitudes above 000 metres and may not be suitable for some countries due to gas regulations. Refer to FAS-0-NG and FAS-0-NGLPG for LPG fuelled system suitable for high altitudes and accepted globally. 240V Gas Consumption LPG (Propane) 540MJ Per Hour 40KPA Gas Pressure Requirements Minimum Inlet Pressure Maximum Inlet Pressure 0KPA 40KPA Door Switch

50/84 Place Fusion Furnace Oil (Diesel) - FAS-20-OIL This furnace has a fan forced dual burner system, with an automatic Ignition System. Temperature is monitored and modulated automatically by a Type K thermocouple system and Omron temperature controller, pre-set for a maximum temperature of 200 degrees Celsius. This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual temperature as well as the temperature the furnace is set to. The door has a pneumatic ram opening system with an easy to use foot pedal control. 240V Pilot Burner Fuel Oil/Diesel LPG Small Gas Bottle High Fire Low Fire 80 PSI 70PSI Air Pressure Switch