Presentation of the inductive electronic ballast

Similar documents
Lemnis public lighting BETTER VISIBILITY WITH LESS ENERGY

Commercial Energy Savings Guide.

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

ENERGY EFFICIENCY IN STREET LIGHTING

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

Customer Services Policies and Procedures Electric Utility

Philips remote monitoring and control systems

Line Loss WSDOT Winter 2008 BZA

Rotherham Metropolitan Borough Council. Appendix A. Street Lighting. Sustainable Energy Action Plan

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

ELECTRIC SCHEDULE LS-2 Sheet 1 CUSTOMER-OWNED STREET AND HIGHWAY LIGHTING

15 Series - Electronic step relay and dimmer. Features SERIE

7. Reactive energy compensation

DuroSite TM High Bay Lighting

Basics of Dimming. ISC Learning Centre

Unit 4: Electricity (Part 2)

Power transformers. Special transformers Railway

Video Camera Installation Guide

COMITÉ EUROPÉEN DES ASSURANCES

induction lighting toll free: tel: fax:

S a f e G u i d a n c e. Single Lamp Control and Monitoring

Rated Lumen [lm] Nominal. Volts [V] [lm]

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

LED Street Lighting Pilot Project Overview

Management of electric vehicle fleet charging

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Light First Social innovation through lighting

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Flicker happens. But does it have to?

FIXED CHARGE: This is a cost that goes towards making the service available, including

RETAIL ELECTRIC SERVICE TARIFF P.S.C. Md. No. 3 R Sheet 61

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

PCS0100en Persy Control Services B.V. Netherlands

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

TIG INVERTER INSTRUCTION MANUAL

factor max Delivering Electrical Efficiency INFORMATION PACK factor max

38 Series - Relay interface modules A

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Power Feeding Equipment for Optical Submarine Cable Systems

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

38 Series - Relay interface modules A

Manual. Solar Fountain Mobile Phone Charger

Exterior Lighting for Energy Savings, Security, and Safety

Improvement of Power Factor for Industrial Plant with Automatic Capacitor Bank

Electricity Terminology. Simplifying energy management

ABB PSPS Erich Steinmann; Generator control-2013

Management of electric vehicle fleet charging

Schedule 2 (Taken in conjunction w/ Schedules 1 or 3)

Energy efficiency improvement and environmental protection have ranked first priorities in utility policies, in developed and developing countries.

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

St. Petersburg Retrofit Projects

Connection method for charging systems a key element for electric vehicles

STREET LIGHTING CONSTRUCTION DESIGN CRITERIA

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

28 th Revision of Sheet No. 58 Canceling 27 th Revision WN U-60 of Sheet No. 58

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

(Refer Slide Time: 00:01:43 min)

Technical Data. Dimensions

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Parking Guidance System

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

commercial LUMINAIRE COMPONENTS WARRANTIES MADE IN CANADA MU-AL MU-AN

High Pressure Mercury

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

MasterINTERFACE 39 Series - Relay interface modules

Multi-Protocol decoder with Load regulation

High Bay Occupancy Sensor Selection Guide

Sample. What Electricity Can Do LESSON 2. Overview and Objectives. Background

ABB i-bus KNX Switch Actuators SA/S Product Information

Approved Meter Sockets and Cabinets

Unit 6 Transformers. Lead-in. Basic principles. Task 1. Task 2. What applications of transformers do you know?

DALI RC BASIC SO. Control unit Operating instructions

Know-how and commitment are always included. Service offer of CG Drives & Automation

Multi-Vapor Metal Halide Lamps

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

DIRECT CURRENT GENERATORS

Victoria Government Gazette

Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01

ABB i-bus KNX Switch Actuators SA/S Product Information

Operating Instructions

Windshield Wiper Motors

Model 1756 Test Lead Kit

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

OZW30. Central Unit SYNERGYR

LG LED Road & Street Lighting

Inwall 4 Input / 4 Output Module

Proof of Concept - Solar Energy DG Distribution Warehouse

DIAGNOSIS SYSTEM (3S GTE and 5S FE)

RO 340 ECO. The challenge of obtaining maximum energy efficiency has been overcome with the following: Maximum efficiency of each of its components:

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

48 SERIES Relay interface modules 10 A

Transcription:

Presentation of the inductive electronic ballast Marc Villez SOGEXI, 1, rue de Maupas, 69380 Les Chères, France Email: marc.villez@sogexi.com KEYWORDS technology, street lighting, electronic ballast, public lighting, efficiency, equipment, control gear, high pressure sodium, metal halide, R&D ABSTRACT This paper describes the technology behind inductive electronic ballasts used to run high-pressure sodium lamps and metal-halide lamps. Inductive electronic ballasts replace traditional control gears to operate such lamps, and in doing so, it offers long-term energy savings and reduction of greenhouse gas emissions. Inductive ballasts also enable electronic dimming, allowing to up to 60% reduction in energy consumption. The inductive ballast described in this paper has a power factor of 1.0 with nearly no electromagnetic pollution on networks. The ballast further provides galvanic insulation from the main. The risk of electric shocks is avoided and maintenance is reduced (no risk for general short circuit or earth leakage). Automatic regulation of the lamp feeding will maintain constant light output as well as longer lamp lifetime. Two large outdoor lighting installations in France are already equipped with inductive electronic ballasts. BACKGROUND The inductive electronic ballast has been designed 7 years ago to run High Pressure Sodium and also Metal Halide lamps. It replaces the standard ferromagnetic control gear, which is traditionally used to run discharge lamps used for street lighting. Today, more than 18 000 lamp posts are run each night by this electronic system worldwide. We will speak later about our most significant references. A street lighting network equipped with such inductive electronic ballasts offers a range of advantages that are technically and economically impossible to achieve with traditional power-feeding systems. The concerned public authority gets the warranty of a safety level towards street or road users that responds to all European requirements. This safety warranty is achieved both on electrical and on light output functions, thanks to the basic principle of electromagnetic induction. This technological particularity allows the electronic ballast to equip new street lighting installations, but also to improve old installations, bringing them to current safety requirements. By this way, it can be much more useful and easy to replace only the feeding system of an old street lighting network, rather than changing the whole equipment: changing a steel pole that could last some more 10 years and its individual lantern would cost much more than replacing only the old and sometimes dangerous control gear by a totally safe electronic ballast. Equipping a street lighting network with inductive electronic ballasts offers 4 major advantages: The first particularity concerns energy saving: 15% to 20% savings can be easily observed on an installation equipped with electronic ballasts in comparison with an installation equipped with the standard system. 3 reasons explain this difference of consumption: Electronic circuits use much less current for their own running in comparison with a traditional control gear, composed by the ballast, the capacitor and the ignitor. RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 51

SESSION 5: PUBLIC LIGHTING 2 VILLEZ The losses on such standard coils reach in average 15%. For a similar use and a similar lamp power, only 5% losses are measured on the electronic ballast. A proof of this better electrical efficiency consists in its T, which remains at 25 C. This fact creates of course less heat losses into the atmosphere, contributing to reduce the greenhouse effect. Following this, the power factor of the electronic ballast is obtained without any compensation. It is therefore guaranteed over time. The subscribed power of the global installation can be reduced and is never exceeded. Losses are also reduced on the feeding lines. The last explanation of such a consumption difference is based on the fact that the electronic ballast regulates the power supplied to the lamp independently of Main s voltage fluctuations. Those voltage increases occur often during the night. In this case, the consumption of a standard control gear increases directly: a 150W High pressure Sodium lamp can consume until 205W if the Main s voltage goes from 230V until 245V. In this case, it is obvious that the light output of this standard control gear will also increase, but the result will be an over lighting: the light pollution will be obvious. On the other hand, if the Main s voltage decreases from 230V until 220 or 210V, the consumption of the ferromagnetic control gear will directly decrease, as a consequence that the light output will also seriously decrease: in this case, the light level will be too low, which can be dangerous for road traffic. Thanks to its automatic regulation of the lamp power, the inductive electronic ballast allows a constant consumption but also a constant light output. This offers the guarantee for road users to get a constant visual safety when they are driving. For street passers-by, a constant light level creates a safety feeling which maintain people in some areas and avoids to create empty places, which generates insecurity and vandalism. The second characteristic concerns a flexible dimming facility Each electronic ballast can be dimmed on 3 different levels: 75% power, 50% power or lamp switched off. The dimming system of the electronic ballast offers a high level of flexibility. Indeed, each lamp post can be dimmed individually, according to its position in the street. For example, a crossroad can be illuminated at 100% during all the night, while some other lamp posts can be dimmed at 50% in some residential areas that are less visited at night. The wished dimming period can be easily chosen on a clock mounted on a general dimming transmitter installed in the head cabinet of the lines. The dimming signal is sent directly on the Main. Of course, the main interest of dimming is to make some more energy savings: if this dimming option is used, the electricity needs of an installation equipped with electronic ballasts can reach 50 to 60% less than for a standard street lighting installation. Another reason for dimming is to avoid light pollution in the middle of the night: for example, 25% power reduction means about 50% less light. For all those reasons, the inductive electronic ballast is supported by the ADEME Agency for big installations. The wide choice of dimming signals that are technically compatible with the inductive electronic ballast allows the user to find a satisfying solution for each network configuration. Finally, the standard dimming signal sent by the transmitter does not creates any electromagnetic pollution and does not disturb the feeding of other complementary urban equipment, like bus shelters or road indication panels. The third advantage concerns the maintenance: High-quality electronics chosen in the range of militarystandard components is used for the circuits of the inductive electronic ballast. The main part of the unit is protected inside an IP65 plastic casing filled with an insulating resin, giving to the whole unit the Class II safety degree. An important part of the maintenance cost of a street lighting equipment comes from the lamp. Big cities for example use to do systematic changes of lamps every 2 or 3 years. Thanks to its constant regulation of the lamp s feeding, the electronic ballast allows to increase considerably the life time of the lamp. A lamp fed with a constant power will logically last longer than a lamp victim of regular voltage increases which generates an obvious over consumption. Thus, its has been measured that a lamp fed with an inductive electronic ballast still produce 95% of its initial light output after 8500 hours, which corresponds roughly to a 2-years running time. On the same basis, a lamp fed with a standard ferromagnetic control gear produces around 10% less light after the same time. We will study further on a realistic example of maintenance s costs saving allowed on lamps. The fourth characteristic of the electronic ballast is based on its main technical characteristic: the electromagnetic induction Indeed, the main part of the ballast is equipped internally with a real separation transformer: thus, there is a galvanic separation between the current coming from the Main and the current going to the lamp. The electricity transmission within the electronic ballast is made through induction. That means that a floating potential is created within the lamp post, because there is no more liaison to earth. This particularity offers a significant advantage both for people and technicians regarding electrical safety: in fact, that means that there is no more risk of electrocution by touching a badly insulated lighting column that would be in contact with an internal wire of the lamp circuit. The second advantage of this physical separation between Main and lamp circuits concerns the maintenance: in case of a short-circuit, the lamp switches off, but re-ignites naturally once the short-circuit is over. Such a shortcircuit can no longer be transmitted to all the street lighting line, which would in such a case plunging the whole neighbourhood into darkness. Failure of the entire street 52 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE

VILLEZ SESSION 5: PUBLIC LIGHTING 2 lighting lines are sometimes created on purpose by drug dealers or thieves in order to handle quietly. Such vandalism acts can no longer happen with inductive electronic ballasts, who guarantee permanent lighting for traffic and pedestrian areas. This electronic feeding system is not anymore a prototype: more than 300 cities and various areas are equipped worldwide since 1997. The biggest part of those references are located in France and its Overseas Territories. European countries like Belgium, The Netherlands or Switzerland have already tested the system. The 2 most prestigious references in France are two airports: the Paris-Orly airport, equipped with around 200 units, and the Pôle Caraïbes airport of the Guadeloupe Island in the French West Indies, with about 300 units. Both have chosen the system for its impact on their global electricity bill, but also for its performances regarding its low electromagnetic pollution rate, compared with a standard system. Other prestigious references are given by European capitals like The Hague in Holland or Brussels in Belgium. The main interest for those two cities were energy saving, reduction of light pollution and guarantee of permanent light in unsafe areas. Finally, Infrastructure Ministries and Roadways Administrations like Rijkswaterstaat in Holland have equipped several installations for the flexibility of its dimming system allowing a minimum light level for late night drivers, and for the ease of lamps maintenance allowed by the electronic ballast. RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 53

SESSION 5: PUBLIC LIGHTING 2 VILLEZ Return on investment for a street lighting installation equipped with inductive electronic ballasts Example for 50 lamp posts 150W HPS Control gears purchase (Costs in Euros) Ferromagnetic ballast + ignitor + capacitors + Class II protection box (IP44, Class II) = 129 Euro x 50 units = 6578 Euro Cost of a traditional feeding system 6578 Euro Inductive electronic ballast (IP 65, Class II) = 300 Euro x50 units = 15 000 Euro Dimming order transmitter 20A three phased x1 unit = 526 Euro Total cost of an electronic feeding system with dimming option 15526 Euro Conclusion: Over cost for an electronic feeding system 8948 Euro Electricity budget Running time of the lamps With traditional feeding January February March April May June July August September October November December Period by 100% 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Total = 4 240 hours / year With the electronic feeding + dimming function Period by 100% Dimming period Chosen dimming level 50% January February March April May June July August September October November December 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Total = 4240 hours / year 100% level = 1381 hours 50 % level = 2859 hours 54 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE

VILLEZ SESSION 5: PUBLIC LIGHTING 2 Electricity price Electricity supplier : E.D.F. Used prices : Blue price-list for long use in public lighting (Code 071) Price of the KVA (Kilo Volt Amp) = 92,18 Euro Price of the KWH (Kilowatt hour) = 0,04 Euro Average night voltage on Main s supply = 242 V Consumption with ferromagnetic control gear Consumption of each lamp post (242V) = 200W Global power = Number of lamp posts x Consumption per unit = 50 x 200W = 10 KW Subscribed power = Global power / power factor (average power factor = 0,7) = 10 KW / 0,7 = 14,3 Kilo Volt Amps (KVA) Subscription for 1 year = Subscribed power x Price of the KVA = 14,3 KVA x 92,18 = 1318,17 Euro Cost of the consumption for 1 year = Global power x Number of hours x Price of the KW/hour = 10 KW x 4240 x 0,04Euro = 1696 Euro Yearly electricity budget = Subscription + Cost of consumption = 1318,17 Euro + 1696 Euro = 3014,17 Euro Consumption with the inductive electronic ballast Consumption of each lamp post (242V)= 160W (by 100% running) 80 W (by 50% dimming) Global power = Number of lamp posts x Consumption per unit Global power by 100% running = 50 x 160W = 8 KW Global power by 50% dimming = 50 x 80W = 4 KW Subscribed power = Global power by 100% running / power factor (power factor = 0,98) = 8 KW / 0,98 = 8,1 Kilo Volt Amps (KVA) Subscription for 1 year = Subscribed power x Price of the KVA = 8,1 KVA x 92,18 = 746,66 Euro Cost of the consumption for 1 year = Global power x Number of hours x Price of the KW/hour Cost of the consumption for 1 year by 100% running = 8 KW x 1381 x 0,04 Euro = 442 Euro Cost of the consumption for 1 year by 50% dimming = 4 KW x 2859 x 0,04 Euro = 457,5 Euro Yearly electricity cost = Subscription + Cost of consumption by 100% running + Cost of consumption by 50% dimming Yearly electricity cost = 746,66 Euro + 442 Euro + 457,5 Euro = 1646,2 Euro Conclusion Total cost saving on the electricity bill of this installation equipped by inductive electronic ballasts dimmed to 50% from 10:00pm to 06:00am = Yearly budget of the installation with traditional systems Yearly budget of the installation with inductive electronic systems = 3014,17 Euro - 1646,2 Euro = 1368 Euro Maintenance cost of the lamps Systematic change of all the lamps The power regulation function of the inductive electronic ballast increases the economic life time of the lamps, because it preserves them from over-running due to Main s voltage variations. Thus, a global relamping can be organized every 3 years, instead of every 2 years. Cost of a global relamping operation = 40 Euro per lamp Saving made thanks to the electronic ballast = (40 / 2) (40 / 3) = 20 13 = 7 Euro per year Yearly saving on the complete installation = 7 x 50 = 350 Euro Conclusion Return on investment for a street lighting installation equipped with 50 inductive electronic ballasts: YEARLY ENERGY SAVING 1368 Euro YEARLY SAVING FOR THE LAMPS MAINTENANCE 350 Euro YEARLY TOTAL SAVING WITH INDUXI 1718 Euro RETURN ON INVESTMENT 8948 / 1718 Euro 5 YEARS 2 MONTHS RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 55

SESSION 5: PUBLIC LIGHTING 2 VILLEZ OBSERVATIONS THIS RETURN ON INVESTMENT CALCULATION DOES ONLY TAKE INTO ACCOUNT THE ENERGY SAVINGS AND THE LAMPS MAINTENANCE SAVINGS. DO NOT FORGET THE OTHER EXISTING MAINTENANCE COSTS SAVINGS MADE WITH INDUXI! YOUR RETURN ON INVESTMENT CAN BECOME SHORTER! THEY ARE QUITE SIGNIFICANT AS WELL AND GIVE YOU A GOOD IDEA ABOUT THE RELIABILITY OF THE INDUXI SYSTEM. ASK YOUR CUSTOMERS HOW MUCH DO FOLLOWING OPERATIONS COST THEM: Ferromagnetic gear INDUXI Change of the ballast 10 / 15 years 20 years Change of the ignitor 3 / 4 years 20 years Change of the capacitors 4 / 5 years 20 years (to preserve a correct cosϕ) Maintenance of earth circuit? No earth leakage current Bad connection inside the Purchase of a No risk of control gear new control gear bad connection Corrosion of the control Purchase of a No risk of gear (connections) new control gear corrosion (IP65 Cl. II) Short-circuit on the Time to find the No risk of lamp's cables failure + repair short-circuit Change of the luminary A Class II luminaire No need of may be required Class II luminaires Lamp at end of life The lamp blinks: time Led light that to find what is the problem indicates for the maintenance team what is wrong SAFETY Purchase of one supple - Total safety What is the price of safety? mentary earth leakage included switch for each pole 56 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE