Sterilization, Disinfection, and Decontamination

Similar documents
Professional Certification in Biological Waste Management Examination Content, Sample Questions & References

Decontamination and Waste Management

CHAPTER V: DISPOSAL OF WASTES CONTAMINATED WITH INFECTIOUS AGENTS

IX. Decontamination and Spills

STERILIZATION AND DISINFECTION

AUTOCLAVE PROGRAM. SOP Bio-006 FOR THE USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE SOP

position statement INFECTION CONTROL INTRODUCTION POSITION STATEMENT PERFORMANCE EXPECTATIONS

Infection Prevention + Control

Appendix B Decontamination and Disinfection

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

STERILIZATION د STERILIZATION

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

Procedures for the Effective Use of Biological Safety Cabinets

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

Laboratory Biosafty In Molecular Biology and its levels

Fundamental Autoclave Techniques

THE BASICS OF STERILIZATION

Policies. Prep Room Policies

Inherent in any infection control strategy are two significant concepts: (i) Routine Practices, and (ii) Risk Assessment.

Biosafety Level 2 (BSL-2) Safety Guidelines

Biohazard and Biosafety

KGI MEDICAL WASTE MANAGEMENT PLAN

PETITION FOR EVALUATION AND APPROVAL OF REGULATED MEDICAL WASTE TREATMENT TECHNOLOGY PART A: GENERAL INFORMATION

GUIDELINES: Aseptic Technique for Rodent Survival Surgeries Surgical Area Animal Preparation 1.

Laboratory Safety: Work Practices for Mycobacterium tuberculosis

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

Cleaning, Disinfection, and Sterilization. Basics of Infection Prevention 2-Day Mini-Course 2013

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Risk Assessment: Biosafety Cabinet

PACUC Guidelines. Rodent Survival Surgery

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

UCCS Biosafety Management Policy

Biohazardous Waste Management Plan

MANAGEMENT AND DISPOSAL OF BIOLOGICAL WASTE AT TEXAS A&M INTERNATIONAL UNIVERSITY

Sterilization, Disinfection and Biosafety. Department of Microbiology College of Medicine University of Baghdad

BSL 1 Laboratory Biosafety Manual

GUIDELINES FOR THE MANGAGEMENT OF BIO- MEDICAL WASTE AT THE SCHOOL OF LIFE SCIENCES

MANAGEMENT AND DISPOSAL OF BIOLOGICAL WASTE TEXAS A&M UNIVERSITY. July 2003

Standard Operating Procedure for Dacarbazine in Animals

BIOLOGICAL WASTE DISPOSAL (Biohazardous & Anatomical Wastes)

"ADOPTED STANDARDS FOR THE REGULATION OF MEDICAL WASTE" IN HEALTH CARE FACILITIES LICENSED BY THE MISSISSIPPI STATE DEPARTMENT OF HEALTH

ENVIRONMENTAL HEALTH AND SAFETY STANDARD OPERATING PROCEDURES

Dartmouth College. Institutional Biosafety Committee. Biohazardous Waste Disposal Guide IBC Approved: 10/7/15

Guidance on safe use of Autoclaves

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

BIOLOGICAL WASTE PROGRAM

CHILDCARE SETTINGS. Childcare Settings

Medical or Biological Waste: Storage, Treatment, Disposal and Transportation Plan

Administrative Procedure

Safe Operating Procedure

Case Study: Successful Decontamination of an HVAC System s Ductwork Using Chlorine Dioxide Gas

Lab Safety and Standard Operating Procedures. Faculty of Dentistry And School of Biomedical Engineering

Infection Control in the Dental Practice through Proper Sterilization

Biological Safety Program

UNIVERSITY OF MIAMI OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY (EHS) BIOLOGICAL AGENTS REGISTRATION FORM

Response to Biological Spills in the Laboratory (Intentional or Accidental)

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

Key words: Low temperature Sterilization (LTS), Single-Use Cardio Catheterization (SUCC). Ethylene Oxide (ETO), Royal Medical Services (RMS).

Biosafety Guidelines. 5. Pipetting Mechanical pipetting devices must be available and used. Mouth pipetting is prohibited.

UNCG Safety and Health Policy and Procedure Manual Section 0260 Page 1 of 14 Date: 1/08 Revised: 12/09

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Cleaning, Disinfection and Sterilization

Now Resistant Microorganisms Have No Place to Hide

Disinfection and Sterilization of reusable medical devices in General Practice

Guidelines for the Use of Sanitizers and Disinfectants

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

Biomedical Waste Management Plan

Blood Borne Pathogen Exposure Control Plan Checklist

Genett Group, Inc. Genett Group, Inc. Anti Microbial Technology. Hospitality Schools Hospitals Construction Remediator Assessor

CENTRAL SERVICE REGULATIONS FOR AMBULATORY SURGERY CENTERS

CARE HOMES AND NURSING HOMES

University of Colorado at Boulder

TARLETON STATE UNIVERSITY Biohazardous Waste Program

Cleaning and Disinfection Agenda. 1. Cleanroom Classification. Cleanroom Classification. What does contamination mean? Types of contamination

Infectious Waste Management Plan

Bloodborne Pathogens Program Revised July,

Introduction BIOMEDICAL WASTE

Steam Sterilization Cycles for Lab Applications

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

BIOLOGICAL SAFETY CABINET PROGRAM

Appendix J IBC Biohazard Spill Management Plan

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

WHEN IT RAINS, IT POURS WATER DAMAGE RESTORATION

COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION

BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS

FACT SHEET : Using Autoclaves Safely

33 Infection Control Techniques

Biohazardous Waste Disposal. Table of Contents

Policy for the Disposal of Biological Waste

THE UNIVERSITY OF MAINE BIOMEDICAL WASTE MANAGEMENT PLAN

LABORATORY ORGANIZATION

AFDO 2010, Norfolk, VA James Marsden Regents Distinguished Professor Jasdeep Saini Kansas State University

University of Otago. Laboratory Biohazard Waste Disposal. Guidelines

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

APPENDIX D INFECTIOUS WASTE MANAGEMENT GUIDE

Transcription:

Sterilization, Disinfection, and Decontamination Decontamination & Cleaning Decontamination renders an item or material safe to handle. The level of microbial contamination is reduced enough that it can be reasonably assumed free of risk of infection transmission. Sterilization, disinfection, and antisepsis are forms of decontamination. Sterilization A sterile surface/object is completely free of living microorganisms and viruses. Sterilization procedures kill all microorganisms. Methods used in sterilization procedures include heat, ethylene oxide gas, hydrogen peroxide gas, plasma, ozone, and radiation. Sterility Assurance Level - the probability of a microorganism surviving on an item subjected to treatment is less than one in one million. Steam Sterilization (Autoclaving) Autoclaving (saturated steam under pressure of approximately 15 psi to achieve a chamber temperature of at least 121 o C for a prescribed time) rapidly achieves destruction of microorganisms, decontaminates infectious waste and sterilizes laboratory glassware, media, and reagents. For efficient heat transfer, steam must flush the air out of the autoclave chamber. Before using the autoclave, check the drain screen at the bottom of the chamber and clean it, if blocked. If the sieve is blocked with debris, a layer of air may form at the bottom of the autoclave, preventing efficient operation. Prevention of entrapment of air is critical to achieving sterility. Material to be sterilized must come in contact with steam and heat. Chemical indicators, e.g., autoclave tape, must be used with each load placed in the autoclave. The use of autoclave tape alone is not an adequate monitor of efficacy. Autoclave sterility monitoring should be conducted on a regular basis (at least monthly) using appropriate biological indicators (B.stearothermophilus spore strips) placed at locations throughout the autoclave. The spores are more resistant to heat than most thereby providing an adequate safety margin when validating decontamination procedures. Each type of container employed should be spore tested.

Decontaminate all infectious materials and all contaminated equipment or labware before washing, storage or discard as infectious waste. Autoclaving is the preferred method. Never leave an autoclave in operation unattended (do not start a cycle prior to leaving for the evening). Log sheets should be available at each autoclave to record the name of the user, time of run, and amount being autoclaved. All personnel using autoclaves must be adequately trained by their PI or lab manager. Never allow untrained personnel to operate an autoclave. Disinfection Eliminates most pathogens but not necessarily all types of microbes. Disinfection reduces the level of microbial contamination. Chemical disinfection does not kill spores, unlike chemical sterilization. Some common laboratory disinfectants include 10% bleach, 70% ethanol, Spaulding Classification of Disinfection Chemical Germicide Activity Level: High Level Disinfection o Comprises high concentrations of chemical germicides (ex: concentrated sodium hypochlorite). o Kills vegetative microorganisms and inactivates viruses o Does not kill high numbers of bacterial spores o High level disinfectants are typically used for short time periods (10-30 min) for disinfection purposes, but may achieve sterilization if left in contact with the surface for long time periods (6-10 hours). o Not for use on environmental surfaces like floors or lab benches Intermediate Level Disinfection o Kills vegetative microorganisms, including Mycobacterium tuberculosis, all fungi, and inactivates most viruses o EPA Approved Hospital Disinfectants which are also tuberculocidal fall into this category o May be used for housekeeping and disinfection of laboratory benches Low Level Disinfection o Kills most vegetative bacteria, some fungi, and inactivates some viruses. Does not kill M. tuberculosis

o Also known as hospital disinfectants or sanitizers From: Biosafety in Microbiological and Biomedical Laboratories 5th Edition (2009); p330.

From: Biosafety in Microbiological and Biomedical Laboratories 5th Edition (2009); p330. NB: Prions are resistant to conventional uses of heat and/or chemical germicides for the sterilization of instruments and devices. Consult Biosafety Officer for more information. Antisepsis Antisepsis is the application of a liquid antimicrobial chemical to skin or living tissue to inhibit or destroy microorganisms. It includes swabbing an injection site on a person or animal and hand washing with germicidal solutions.

Radiation The office of laboratory safety discourages the use of UV lamps in biosafety cabinets. UV is not effective on porous materials that are opaque to the light such as wood or foam. UV is not effective if a microbe is protected by dust, dirt, or organic matter. UV light is affected by the accumulation of dust and dirt on the bulb surface. UV does not work in shadowed areas; penetrate into cracks or through the grill of a BSC Humidity adversely affects the effectiveness of UV. Above 70% relatively humidity, the germicidal effects drops off precipitously Burgener, J. 2006. Applied Biosafety. 11(4)228-230