Hematology, Chemistry, Coagulation. Helpful Hints

Similar documents
Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Examples: collecting the right sample on the right patient; labeling the sample accurately;

Equipment Qualification

Procedure: Quality Assurance Policy Version 5 Quality Assessment Policy Version 3

QUALITY CONTROL (QC) INFORMATION AND TROUBLESHOOTING GUIDE HEMATOLOGY

MANUAL PLATELET COUNT

Calibration Verification

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

Prepublication Requirements

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

How to Verify Performance Specifications

Basic Lessons in Laboratory Quality Control

MANUAL WBC LAB OBJECTIVE

Level 1 Hematology Training Module For AcT Diff and AcT Diff 2

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

Preparation of Blood Films

Quality Assurance/Quality Control in Acid Deposition Monitoring

MANUAL PLATELET COUNT

ASSURING THE QUALITY OF TEST RESULTS

Content Sheet 3-1: Equipment Management Overview

Department of Pathology and Laboratory Medicine Capital District Health Authority Nova Scotia

Minneapolis User Group Meeting

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: CONTINUOUS RADON MONITOR (CRM) by Proportional Counting. Method Number: ELAP method code 7037

Hematology Reagents and Controls Our products for your critical process

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

Incident Management: Developing a Plan

Automation is Here. Now How Do You Handle All the Data? Swedish Covenant Hospital Lab. Life IS Good

Lab 02: Blood Cytology (20 points)

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Effective Training for Cell Therapy Laboratories. Diane Kadidlo MT(ASCP) University of Minnesota Molecular and Cellular Therapeutics Facility

Medical Cannabis Laboratory Approval Program

PROCEDURES FOR HANDLING OOS RESULTS

HAEMATOLOGY LABORATORY

BC Auto Hematology Analyzer

Laboratory Equipment Training to Improve Quality of Laboratory Services and Patient Care

Cold Agglutination Titer detecting Cold Reacting Antibodies

Biochemistry Validation Form

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program

Measurement and Calibration

Quality control in dental practice Peter Kivovics DMD, BDS, MDSc, PhD, Chief Dental Officer for Hungary

LABORATORY SUPERVISOR JOB CODE: 2701 DATE: 11/8/95

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

TEST METHOD VERIFICATION AND VALIDATION

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

And Now, Presenting...

COULTER LH 750 HEMATOLOGY ANALYZER. COULTER LH 780 HEMATOLOGY ANALYZER Training Modules. This Training Guide belongs to:

1 Quality Assurance and Quality Control Project Plan

Pentra DX Nexus. Process efficiency in Hematology

UNIVERSITY OF CONNECTICUT HEALTH CENTER CORRECTIONAL MANAGED HEALTH CARE POLICY AND PROCEDURES FOR USE WITHIN THE CONNECTICUT DEPARTMENT OF CORRECTION

XV.Quality Assurance in the Blood Bank

Document and Record Control in a Hospital Clinical Laboratory

Quality Assurance (QA) & Quality Control (QC)

COULTER A C T diff COULTER A C T diff 2

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Hematology Case Studies: Platelets

Contents. Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions...

Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard

If your doctor has ordered laboratory tests, it s natural

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD

Individualized Quality Control Plan

Inspection, Measuring and Test Equipment (IMTE) Calibration

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Quality Requirements of a Point of Care Testing Service

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material)

For In Vitro Diagnostic Use

Six Sigma Metric Analysis for Analytical Testing Processes

PERFORMANCE EVALUATION AUDIT CHECKLIST EXAMPLE. EIIP Volume VI

CHE 114L: Lab 1 The Chemistry of Baking Soda

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

CHAPTER 7 QUALITY ASSESSMENT

Collection Guidelines for Routine & Special Coagulation Testing

Validation and Calibration. Definitions and Terminology

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

New Oral Anticoagulants

Measuring Heart Rate

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

IDEXX Catalyst Dx* Chemistry Analyzer Maintenance Log. Year: Frequency Maintenance Required

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

M E M O R A N D U M. Austin Police Department Field Support Services Forensic Science Division

Document Review: Centers for Medicare and Medical Service (CMS) What Do I Need to Do to Assess Personnel Competency?

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

PERFORMANCE-BASED EVALUATION OF LABORATORY QUALITY SYSTEMS An Objective Tool to Identify QA Program Elements that Actually Impact Data Quality

Installation and Operational Qualification Protocol (Reference: SOP )

A Practical Guide to Internal Quality Control (IQC) for Quantitative Tests in Medical Laboratories

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Quality Management Systems for Seed Testing Laboratories: Presented to the 2010 CSAAC Meeting. Valerie Martz Senior Laboratory Accreditation Officer

Position Classification Standard for Medical Technician Series, GS-0645

CHAPTER ONE TABLE OF CONTENTS 1.0 INTRODUCTION... 1

Lupus anticoagulant aptt & drvvt screening panel W Reflex

Transcription:

Hematology, Chemistry, Coagulation Helpful Hints

Hematology A good check to see if your Complete Blood Counts on your patient results are valid is the RULE OF THREE

Hematology Rules of Three for normal Hematology Rule #1 Hgb X 3 = Hct +/-2 Rule #2 RBC x 3.3 = Hgb +/- 1.5 Rule #3 RBC x 9 = Hct +/3

Hematology The laboratory must verify calibration on the instrument every 6 months or on an as needed basis to ensure accuracy of the system.

Hematology And why else would calibration be necessary? 1. Critical parts are replaced such as manometers, apertures, or detector circuit boards 2. Controls show an unusual trend or are outside of acceptable limits and cannot be corrected by maintenance or troubleshooting.

Hematology Low platelet counts on an individual that has no bleeding symptoms, try checking the blood smear for platelet clumping or platelets satelliting around the neutrophils

Hematology To help correct this problem, use sodium citrate as an alternative anticoagulant (because EDTA induced platelet clumping) and multiply the citrate platelet count and WBC by 1.11 to correct for anticoagulant dilution

Hematology What should you be doing if you have two different hematology instruments? Or if you have two instruments that are the same

Hematology Comparison check

Hematology Do not use non Clorox bleach or any scented Clorox bleach for cleaning the instruments. If you can not get Clorox, then

Chemistry The laboratory must very calibration every six months or on an as needed basis to ensure accuracy of the system.

Chemistry And why else would calibration be necessary? 1.Critical parts are replaced 2.Controls show an unusual trend or are outside of acceptable limits and cannot be corrected by maintenance or troubleshooting.

Coagulation If you are using a manual or semiautomated method for your APTTs, the timing of the incubation of your patient plasma + reagent is critical. The Timing of your duplicate testing needs to be precise. Any deviations in timing will usually result in the duplicate test results not matching.

The tests needs to be run with the same timing limits as the controls. So what does that mean you should be checking?

Coagulation Your timer!

Controls (normal and abnormal) are typically valid for one year. Ranges are not established so you must establish your own ranges. Run the controls a minimum of 30 times to establish the mean and SDs.

Quality Control Internal Quality Control Reagent Check (Parallel Testing) External Quality Control (proficiency programs) Blind Samples Competency Checks

Quality control material Quality control ranges Plotting results (Levey-Jennings Graphs) Reviewing Results Corrective Action Logs Reagent Checks (parallel testing) Review & Signature

Do you have appropriate controls for each procedure? Quantitative: low (normal) & high normal & abnormal

Do you treat your control material like the patient samples? Are the control results verified BEFORE patient results are released?

How often do you run your controls? *per manufacturers instructions *per laboratory guidelines *can always run more than recommendation *balance time, cost and efficacy

General Guidelines CBC: per 8 hour shift Manual Differentials/BPS: per day (stain check) Chemistry: per 8 hour shift

Document results on run sheet or QC log Include lot # s & expiration dates Include tech initials & run date For QT assays, SD) Manufacturers Mean & Range (~+2.5 Internal Mean + 2 & 3 SD Levey-Jennings Control Charts

Why use Levey-Jennings control charts? Patterns 1:2s, 1:3s Dispersion (loss of precision) Trend Shift

Lab supervisor review if exceeded (*before patient results are released) Corrective action if needed (document) Retest if required

QC failures must be reviewed and signed off by lab supervisor or higher All unexpected or failed QC results must be documented Corrective Action Log Final action must demonstrate problem was resolved Lab Sup/Mgr must review/sign CA Logs at least monthly Must have CA log for every test/equipment/system

Why do parallel testing? Consistency of patient results Transition of control

Chemistry: New control lot in parallel mean/sd CBC/FBC: New control lot in parallel 3-5 days

At the October Meeting: Westgard Rules Normal Values QC and corrective action QA Instrument Validation Carryover Studies