Lecture 15 DIRECTIONAL CONTROL VALVES

Similar documents
The Secret of Hydraulic Schematics. BTPHydraulics

Unit 24: Applications of Pneumatics and Hydraulics

SIMPLIFIED VALVE CIRCUIT GUIDE

Example. Fluid Power. Circuits

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

SIMPLIFIED VALVE CIRCUIT GUIDE

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

COUNTERBALANCE VALVES

Unit 24: Applications of Pneumatics and Hydraulics

Proportional and Servo Valve Technology

Hi-Cyclic. 2, 3 and 4-Way Directional Control Valves for Pneumatic and Hydraulic Service

Introduction to Pneumatics and Pneumatic Circuit Problems for FPEF Trainer

Pressure Relief and Regulating Valves

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Unit 24: Applications of Pneumatics and Hydraulics

PART 2 FORKLIFT HYDRAULIC SYSTEM

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Pneumatics Basic Level Set of Overhead Transparencies TP 101

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

Quiz On Information Learned From Chapter 1

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

2/2 and 3/2 Way Size 6 Seat Valves

ACADEMIC TEXTBOOK FLUID POWER CONTROL SYSTEMS. The lecture: 15 hours. Kielce University of Technology Faculty of Mechatronics and Machine Design

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

Electro-Pneumatic Bus Door Control Mechanism

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

HYDRAULICS AND HWH SYSTEMS

A descriptive definition of valve actuators

Peter Croser, Frank Ebel. Pneumatics. Basic Level

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

THE 26-L BRAKE EQUIPMENT

Hydraulic Trouble Shooting

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Electro-Mechanical Landing Gear System. Landing Gear and Brakes

Hydraulic Troubleshooting PRESENTED BY

Tiguan Haldex All-Wheel Drive

Unit 24: Applications of Pneumatics and Hydraulics

Class 5 to 7 Truck and Bus Hydraulic Brake System

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

4/2-Way Pneumatic Solenoid Valve

Morrison Bros. Co. General Product Specifications

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Directional seated valves type VP 1

M A N U A L

Control block EDD Modular Directional Valve

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan

Oil and Coolant Circulating Heating System. Model - OCSM

LINEAR ACTUATORS. Linear Actuators. Linear Actuators. Linear Actuators are Actuators that creates motion in a straight line, as contrasted

Automatic Transmission Basics

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Electronic Manual Gearbox

Introduction to Process Control Actuators

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Learning Systems Software Simulation

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Electrical Symbols and Line Diagrams

Industrial Steam System Process Control Schemes

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS

Hydraulic Landing Gear System

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Hydraulic Flow Control Valves

MAXIMIZING THE OUTPUT OF YOUR BRAKES Getting Your Pedal Geometry Right

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Suspension and Steering Systems Operation. The Steering/Suspension System (Overview)

Vickers. Overhaul Manual. Directional Controls. Directional Control Valves. DG3V-8/DG5V-8 Hydraulic/Solenoid Pilot Operated 5007.

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

PVH131/141 Variable Displacement Piston Pump - 11 Design

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Mono-Block II Installation & Operation Manual

PRESSURE REDUCING CONTROL VALVE

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Volume. HOMEWOOD PRODUCTS CORPORATION Westinghouse Technology. CA Breaker Instruction Manual

Basic Hydraulics and Pneumatics

Trouble Shooting Tech Tips Operation

Cane Creek Double Barrel Instructions

VEHICLE SPEED CONTROL SYSTEM

3 Port Solenoid Valve

Troubleshooting Guide for Jacks Down LED Lights

Fig 3. PLC Relay Output

Why and How we Use Capacity Control

Load-sensing control block in mono and sandwich plate design

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Rexroth Hydraulic Pump A10VO Series User Manual

Transcription:

Lecture 15 Learning Objectives DIRECTIONAL CONTROL VALVES Upon completion of this chapter, the student should be able to: List different types of valves used in fluid power. Explain various classifications of directional control valves. Describe the working and construction of various direction control valves. Identify the graphic symbols for various types of direction control valves. Explain the different applications of direction control valves. Explain the working principle of solenoid-actuated valves. Define valve overlap. Evaluate the performance of hydraulic systems using direction control valves. 1.1Introduction One of the most important considerations in any fluid power system is control. If control components are not properly selected, the entire system does not function as required. In fluid power, controlling elements are called valves. There are three types of valves: 1. Directional control valves (DCVs): They determine the path through which a fluid transverses a given circuit. Pressure control valves: They protect the system against overpressure, which may occur due to a sudden surge as valves open or close or due to an increase in fluid demand. 2. Flow control valves: Shock absorbers are hydraulic devices designed to smooth out pressure surges and to dampen hydraulic shock. In addition, the fluid flow rate must be controlled in various lines of a hydraulic circuit. For example, the control of actuator speeds can be accomplished through use of flow control valves. Non-compensated flow control valves are used where precise speed control is not required because the flow rate varies with pressure drop across a flow control valve. It is important to know the primary function and operation of various types of control components not only for good functioning of a system, but also for discovering innovative methods to improve the fluid power system for a given application. 1.2Directional Control Valves A valve is a device that receives an external signal (mechanical, fluid pilot signal, electrical or electronics) to release, stop or redirect the fluid that flows through it. The function of a DCV is to control the direction of fluid flow in any hydraulic system. A DCV does this by changing the position of internal movable parts. To be more specific, a DCV is mainly required for the following purposes: To start, stop, accelerate, decelerate and change the direction of motion of a hydraulic actuator. To permit the free flow from the pump to the reservoir at low pressure when the pump s delivery is not needed into the system. To vent the relief valve by either electrical or mechanical control. To isolate certain branch of a circuit.

Any valve contains ports that are external openings through which a fluid can enter and exit via connecting pipelines. The number of ports on a DCV is identified using the term way. Thus, a valve with four ports is a four-way valve A DCV consists of a valve body or valve housing and a valve mechanism usually mounted on a sub-plate. The ports of a sub-plate are threaded to hold the tube fittings which connect the valve to the fluid conductor lines. The valve mechanism directs the fluid to selected output ports or stops the fluid from passing through the valve. DCVs can be classified based on fluid path, design characteristics, control methods and construction. 1.2.1 Classification of DCVs based Fluid Path Based on fluid path, DCVs can be classified as follows: Check valves. Shuttle valves. Two-way valves. Three-way valves. Four-way valves. 1.2.2 Classification of DCVs based on Design Characteristics Based on design characteristics, DCVs can be classified as follows: An internal valve mechanism that directs the flow of fluid. Such a mechanism can either be a poppet, a ball, a sliding spool, a rotary plug or a rotary disk. Number of switching positions (usually 2 or 3). Number of connecting ports or ways. Method of valve actuation that causes the valve mechanism to move into an alternate position. 1.2.3 Classification of DCVs based on the Control Method Based on the control method, DCVs can be classified as follows: Direct controlled DCV:A valve is actuated directly on the valve spool. This is suitable for smallsized valves. Indirect controlled DCV:A valve is actuated by a pilot line or using a solenoid or by the combination of electrohydraulic and electro-pneumatic means. The use of solenoid reduces the size of the valve. This is suitable for large-sized valves. 1.2.4 Classification of DCVs based on the Construction of Internal Moving Parts Based on the construction of internal moving parts, DCVs can be classified as follows: Rotary spool type: In this type, the spool is rotated to change the direction of fluid. It has longitudinal grooves. The rotary spools are usually manually operated. Sliding spool type: This consists of a specially shaped spool and a means of positioning the spool. The spool is fitted with precision into the body bore through the longitudinal axis of the valve body. The lands of the spool divide this bore into a series of separate chambers. The ports of the valve body lead into these chambers and the position of the spool determines the nature of inter-connection between the ports. 2

Table 1.1

Table 1.2 3/2 way valve : 3ports and 2 position DCV

1. Each different switching position is shown by a square. 2. Flow directions are indicated by arrows. 3. Blocked ports are shown by horizontal lines. 4. Ports are shown in an appropriate flow direction with line arrows The switching position, flow direction, and port for different configurations is represented in Table 1.1. Twoway, three-way, four-way and five-way representation is shown in Table 1.2. 1.3Actuating Devices Direction control valves may be actuated by a variety of methods. Actuation is the method of moving the valve element from one position to another. There are four basic methods of actuation: Manual, mechanical, solenoid-operated and pilot-operated. Several combinations of actuation are possible using these four basic methods. Graphical symbols of such combinations are given in Table 1.3. Manually operated: In manually operated DCVs, the spool is shifted manually by moving a handle pushing a button or stepping on a foot pedal. When the handle is not operated, the spool returns to its original position by means of a spring. Mechanically operated: The spool is shifted by mechanical linkages such as cam and rollers. Solenoid operated: When an electric coil or a solenoid is energized, it creates a magnetic force that pulls the armature into the coil. This causes the armature to push the spool of the valve. Pilot operated: A DCV can also be shifted by applying a pilot signal (either hydraulic or pneumatic) against a piston at either end of the valve spool. When pilot pressure is introduced, it pushes the piston to shift the spool.

Solenoid operated Pilot operated Manual operated Push button Foot operated Pilot-operated solenoid Two-position detent Spring return 1.4 Check Valve The simplest DCV is a check valve. A check valve allows flow in one direction, but blocks the flow in the opposite direction. It is a two-way valve because it contains two ports. Figure 1.1 shows the graphical symbol of a check valve along with its no-flow and free-flow directions. 7

Figure 1.1 Graphical symbol of a check valve. In Fig. 1.2, a light spring holds the ball against the valve seat. Flow coming into the inlet pushes the ball off the seat against the light force of the spring and continues to the outlet. A very low pressure is required to hold the valve open in this direction. If the flow tries to enter from the opposite direction, the pressure pushes the ball against the seat and the flow cannot pass through. Valve seat Ball Light spring Inlet Outlet Figure 1.2 Ball-type check valve. Figure 1.3 provides two schematic drawings showing the operation of a poppet check valve. A poppet is a specially shaped plug element held on a valve seat by a light spring. Fluid flows through the valve in the space between the seat and poppet. In the free flow direction, the fluid pressure overcomes the spring force. If the flow is attempted in the opposite direction, the fluid pressure pushes the poppet in the closed position. Therefore, no flow is permitted In Out Figure1.3 Poppet check valve: (a) Open and (b) closed position

1.4.1 Advantages of a poppet valve Virtually zero leakage in closed position. Poppet elements do not stick even when left under pressure for long periods. Fast, consistent response time: typically 15 ms. 1.4.2 Disadvantages of a Poppet Valve A poppet valve has the following disadvantages: Axial pressure balance is impossible and considerable force may be needed to open the poppet against the flow at a high pressure. This limits valves that have direct mechanical actuation to low flow duties. Generally individual poppets are required for each flow path that significantly increases the complexity of multi-port valves. Lapping and super finishing of valves add cost. 1.5 Pilot-Operated check Valve A pilot-operated valve along with its symbol is shown in Fig. 1.4. This type of check valve always permits free flow in one direction but permits flow in the normally blocked opposite direction only if the pilot pressure is applied at the pilot pressure point of the valve. The check valve poppet has the pilot piston attached to the threaded poppet stem by a nut. The light spring holds the poppet seated in a no-flow condition by pushing against the pilot piston. The purpose of the separate drain port is to prevent oil from creating a pressure build-up at the bottom of the piston. The dashed line in the graphical symbol represents the pilot pressure line connected to the pilot pressure port of the valve. Pilot check valves are used for locking hydraulic cylinders in position. No pilot signal Free flow No pilot signal No flow Pilot signal Return flow Figure 1.4Pilot-perated check valve

1.6 Shuttle Valve A shuttle valve allows two alternate flow sources to be connected in a one-branch circuit. The valve has two inlets P 1 and P 2 and one outlet A. Outlet A receives flow from an inlet that is at a higher pressure. Figure 1.5 shows the operation of a shuttle valve. If the pressure at P 1 is greater than that at P 2, the ball slides to the right and allows P 1 to send flow to outlet A. If the pressure at P 2 is greater than that at P 1, the ball slides to the left and P 2 supplies flow to outlet A A A Figure 1.5 Shuttle valve: (a) Flow from left to outlet and (b) flow from right to outlet in Fig. 1.5. One application for a shuttle valve is to have a primary pump inlet P1 and a secondary pump inlet P2 connected to the system outlet A The secondary pump acts as a backup, supplying flow to the system if the primary pump loses pressure. A shuttle valve is called an OR valve because receiving a pressure input signal from either P1 or P2 causes a pressure output signal to be sent to A. Graphical symbol of shuttle valve is shown in Fig. 1.6. Fig 1.6 symbol of Shuttle valve