Tamper Resistant Receptacle

Similar documents
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Model Legislation for Short-Term Online Rentals. Menu

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Inspections must be conducted every three years in order to maintain an "approved" status on the City Of Bozeman Safe Rental Unit List.

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

Carbon Monoxide Alarms

FIRE SAFETY REQUIREMENTS

CHAPTER 9 FIRE PROTECTION SYSTEMS

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

How To Install A Carbon Monoxide Detector

Repairs a guide for landlords and tenants. housing

Power Strip Safety and Regulatory Compliance:

LOCAL LAW # REGISTRATION OF RENTAL HOUSING

OREGON ELECTRICAL LAWS OREGON REVISED STATUTE 479

PSC NO: 9 GAS LEAF: 224 COMPANY: CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. REVISION: 0. RECEIVED: 12/08/98 STATUS: Effective EFFECTIVE: 03/01/99

Smoke & Carbon Monoxide

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Electrical Extension Cords & Relocatable Power Taps: (RPT s)

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

Section 3: Load Planning Bill Brown, P.E., Square D Engineering Services

CERTIFICATE OF COMPLIANCE

Minimum Housing and Health Standards

Rental Registration and Safety Inspection Program

GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

CHAPTER 150: BUILDING REGULATIONS. Adoption of Regulatory Codes by Reference

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Canadian Electrical Code, Part I Full Impact Assessment

[ ] Gas Heat [ ] Electric Heat ******************PLEASE PRINT ****************

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Generic Risk Assessment for use of Residential Accommodation. Visual inspection of fire escapes, alarms, equipment, meeting point and procedures.

Florid a Sta nd ards for Q u ality Afterschool Progra ms

Top Commercial / Residential Electrical Requirements *

CHAPTER MECHANICAL CODE HEATING, AIR CONDITIONING, VENTILATING AND REFRIGERATION DIVISION 2 - APPEALS

FIRE SPRINKLER SYSTEM DESIGN, ENGINEERING EXEMPTION POLICY FOR (Effective April 1, 2006)

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

Building Mechanical Inspector Senior Building Mechanical Inspector Principal Building Mechanical Inspector Chief Building Mechanical Inspector - 2

SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Schedule A. Residential and Seasonal Dwellings. for estimating value of construction in the Township of North Kawartha

2016 BUILDING PERMIT FEES*

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

CITY OF LOS ANGELES CALIFORNIA

THE CORPORATION OF THE CITY OF PORT COQUITLAM BYLAW NO. 3889

2013 BUILDING ENERGY EFFICIENCY STANDARDS

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

TOWN BOARD OF THE TOWN OF NORTH SALEM WESTCHESTER COUNTY, NEW YORK LOCAL LAW # OF THE YEAR 2012

Center for Clinical Standards and Quality /Survey & Certification Group. Categorical Waiver for Power Strips Use in Patient Care Areas

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

5. Specific Use Regulations

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

CHAPTER 3 MANUFACTURED AND MOBILE HOMES

Exhibit C Design Review Guidelines

AN ORDINANCE of the CITY OF MINNEAPOLIS

The Rehab Inspector and LBP

FIRE CODE INTERPRETATION

Table PARKING SPACE RATES AND PARKING SPACE OCCUPANCY

GOLDEN STATE FINANCE AUTHORITY MULTI-FAMILY HOUSING BOND PROGRAM APPLICATION

Home Electrical Safety Challenge

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

RRIO Checklist. Use of checklist: Definitions: Limitations

SECTION 105 PERMITS. 2. Fences not over 6 feet (1829 mm) high. 3. Oil derricks.

BUILDING PERMIT SPECIFICATIONS

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2015 H 1 HOUSE BILL 255. Short Title: Building Code Reg. Reform. (Public)

Errata has been identified as follows:

Botetourt County, Virginia. Frequently Asked Questions

Low Frequency Notification Appliances

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

Electrical Receptacle Outlet Reverse Polarity & Open Ground

What you need to know about. Smoke alarms for residential buildings

This notice sets forth interim guidance, pending the issuance of regulations,

HAWAII ADMINISTRATIVE RULES TITLE 12 DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS SUBTITLE 8 HAWAII OCCUPATIONAL SAFETY AND HEALTH DIVISION PART 1

Building Permit, Fire Inspection and Operating Permit Fee Schedule

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number

Guide for Opening Child Care and Day Care Facilities

BED AND BREAKFAST ESTABLISHMENTS PROVISIONS OF SELECTED MUNICIPALITIES

HOUSING QUALITY STANDARDS (HQS)

LONG TERM RENTAL REGISTRATION APPLICATION All sections are required to be completed. Please print, type, or apply through portal.

Overview of Hotel Fire Safety Requirements

The Different Types of AC Power Connectors in North America

PROPOSED Plumbing Fee Ordinance Amendment

IR F-1 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS

dpd Seattle Permits CAM Establishing an Accessory Dwelling Unit (ADU) What is an ADU?

CHAPTER 6. Massage Establishments

Transcription:

Tamper Resistant Receptacle

Tamper Resistant Receptacle White Paper Purpose: To give a general overview of the description, application, and code discussions for Tamper Resistant Receptacles General Discussion about where Tamper Resistant Receptacles are required. Introduction: Tamper Resistant (TR) receptacles were designed to limit the risk of the proverbial finger in the light socket. As children are known to explore all aspects of their environments, TR was developed as a solution of keeping children safe. They are designed to limit access to the hot and neutral contacts and as a result, reduce the risk of inserting foreign objects and getting shocked. This is most commonly accomplished with shutters that cover the hot and neutral openings and will only allow plugs to be inserted when both shutters have pressure applied simultaneously. TR receptacles are intended to protect children from electrical burns and shocks. In an explanation of the requirements in the National Electrical Code, statistics from 2005 indicated that approximately 89 percent of electrical burn and shock incidents occurred among children 6 years of age or less. Background: The National Electrical Code (NEC) first added requirements for TR receptacles in 2002 in pediatric patient care areas. These areas have the highest traffic volumes for children under age 8. In 2005 the NEC added dwellings to the 2002 required spaces of pediatric rooms, bathrooms, playrooms, and activity rooms. This additional scope then covered the safety of an even greater number of children. The next logical step was shared spaces used by children, as a result, 2011 NEC required TR receptacles in guest rooms and guest suites, child care facilities, and further defined pediatric areas as designated pediatric locations. They also provided exceptions for certain type and location of receptacles in dwellings. Finally, the 2014 NEC provided further clarification of the existing locations including: guest rooms and guest suites of hotels and motels and excluding nurseries for pediatric locations. The NEC is updated every 3 years, so additional changes may happen in 2017 (there are currently no proposals submitted that change or add requirements for TR Receptacles). Each state and or local jurisdiction that utilizes the NEC code for TR enforcement, however, may use different revisions (2005, 2008, 2011, 2014, or future).

Locations and Markets that Require Tamper Resistant Receptacles: Depending on the final installation and application of the product, TR receptacles are required in dwellings (residential market), guest rooms and guest suites of hotels and motels (hospitality market), and designated pediatric locations (healthcare market). Even with these requirements being clearly communicated in the NEC, gray areas exist for applications of TR receptacles that require some unintended locations. An example of this would be when specifiers apply the TR receptacle requirement to all areas of a healthcare facility including areas not applicable to the TR receptacle NEC Code requirements. The code requires TR receptacles in designated pediatric locations but, like many other existing NEC requirements, they may be applied as a preference or out of concern or fear of compliance vs. following TR receptacle NEC requirements. Hospital grade receptacles are a great example of what architects/engineers may do in specifying TR receptacles. More often than not, specific codes are blanketed across all parts of a healthcare facility whether they need it or not. The biggest ambiguity is what product types will require TR receptacle for code compliance applications. For example, the NEC TR code dwelling requirements specify appliances as exempt from the scope of TR receptacles. Relocatable Power Taps are often grouped into this category. It is not clear if accessories, like Relocatable Power Taps, are required to have TR receptacles when used in residential applications given their temporary nature. However, if RPT s are used to comply with the specific locations and number of receptacles called out in the code, hardwired versions most likely will need TR Receptacles. More simply put, if the product is part of the scope for inspection TR will be considered. The code requires TR receptacles in guest rooms and guest suites of hotels and motels. If the product in question is applied temporarily and is outside the scope of the local jurisdiction having authority, however, the product most likely will be accepted. Currently feedback from customers and local authorities having jurisdiction has not been negative.

TR Receptacle Requirements by the NEC in Effect The following table breaks down the 3 primary locations that require TR receptacles by the version of the NEC and compares those to commercial spaces. As noted above, there will be exceptions where TR receptacles will be required and exceptions where TR receptacles won t be required. NEC Version (Year) 2008 NEC 2011 NEC 2014 NEC Residential Hospitality Healthcare Commercial All Required Receptacle Locations All Required locations except at least 5 ½ ft. off floor and receptacles for two appliances in a dedicated space All Required locations except at least 5 ½ ft. off floor and receptacles for two appliances in a dedicated space None All guest rooms and guest suites All guest rooms and guest suites of hotels and motels Pediatric rooms, playrooms, activity rooms, patient care areas Pediatric rooms, playrooms, activity rooms, patient care areas Pediatric rooms, playrooms, activity rooms, patient care areas other than nurseries Not Required Not Required Not Required Conclusion TR receptacles are only required in areas that children under the age of 7 are exposed. Commercial spaces and office buildings, other than childcare facilities, do not require TR receptacles. A significant amount of gray area exists in the application of the NEC requirements. Both the codes and the product categories they cover have ambiguities. Ultimately it will fall on the local jurisdiction that has authority to apply all state, federal (NEC), or municipal codes and regulations that apply to the specific environment. Byrne Electrical Specialists, Inc. has extensive experience in navigating the NEC and working directly with inspectors. We welcome the opportunity to understand the specific environment TR is being required and look forward to finding a solution that works best for you and your customers.

Glossary: Depending on the final installation and application of the product, TR receptacles are required in dwellings (residential market), guest rooms and guest suites of hotels and motels (hospitality market), and designated pediatric locations (healthcare market). Appliances: Per the National Electrical Code, Appliances are: Utilization equipment, other than industrial, that is normally built in standardized sizes or types and is installed or connected as a unit to perform one or more functions such as clothes washing, air-conditioning, food mixing, deep frying, and so forth.: Many include Relocatable Power Taps as appliances. Authoritiy(ies) Having Jurisdiction: Per the National Electrical Code, Authority Having Jurisdiction (AHJ) is: An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure. In this discussion, an AHJ is an electrical inspector, building inspector, or fire marshal that is responsible for confirming electrical installations comply with applicable codes. Sign-off by an AHJ is required before an occupancy permit can be granted. The AHJ makes all final interpretations of the code, even if it seems to be contrary to requirement. Child Care Facilities: Per the National Electrical Code, a Child Care Facility is: a building or structure, or portion thereof, for educational, supervisory, or personal care services for more than four children 7 years old or less. Based on this definition, Child Care Facilities not only include day care centers, they could also include elementary schools. Dwellings: Per the National Electrical Code, a Dwelling is: A single unit, providing complete and independent living facilities for one or more persons, including permanent provisions for living, sleeping, cooking, and sanitation. Dwellings include one family buildings, two family buildings, and multifamily buildings (i.e. apartments). Guest Rooms and Guest Suites: Per the National Electrical Code, a Guest Room is: An accommodation combining living, sleeping, sanitary, and storage facilities within a compartment. A Guest Suite is: An accommodation with two or more contiguous rooms comprising a compartment, with or without doors between such rooms, that provides living, sleeping, sanitary, and storage facilities. The requirements for TR Receptacles specifically calls out guest rooms and guest suites of hotels and motels.

Glossary: National Electrical Code (NEC): The National Electrical Code (NEC) is a document that outlines minimum safety requirements for electrical installations and operations in all types of buildings. The NEC is written and updated by volunteers who are experts in electrical safety, electrical inspectors, etc., and is controlled by the National Fire Protection Association. The NEC is updated every 3 years. The NEC is considered a voluntary standard and its adoption is up to individual states and/or local municipalities. cethe version of the NEC in effect in specific locations from the 2005 edition to the 2014 edition. Some states/cities rewrite the NEC or provide addendums to the NEC. California, Chicago, and New York City are examples. Tamper Resistant (TR) Receptacle: Tamper Resistant (TR) Receptacle Tamper Resistant (TR) Receptacles are designed to limit access to the hot and neutral contacts. This is most commonly accomplished with shutters that prevent access to the contacts unless even pressure is applied to both the hot and neutral shutters at the same time. Index: NEC Adoption Info: What version of the NEC is in effect in your area This page provides a pdf document of NEC adoption by jurisdiction: nema.org NEC version by location California Electrical Code: This page has access to an online version of the current California Electrical Code: http://www.bsc.ca.gov/codes.aspx Chicago Electrical Code: This page is an online version of the current Chicago Electrical Code. Select more in the left column and select Division 27 to see the electrical code: Chicago Electrical Code New York City Electrical Code: This page is a pdf of the current New York Electrical Code. Note in section 27-3024 (Page 2) that New York adopts the 2008 edition of the NEC with changes noted in this code: New York City Electrical Code