WHITE PAPER. Cut-Through Ethernet Switching

Similar documents
WHITE PAPER. Addressing Monitoring, Access, and Control Challenges in a Virtualized Environment

WHITE PAPER. Static Load Balancers Implemented with Filters

EBOOK. Top Five Ways To Enhance Your Cisco Environment

EBOOK. The Network Comes of Age: Access and Monitoring at the Application Level

- Hubs vs. Switches vs. Routers -

WHITE PAPER. Extending Network Monitoring Tool Performance

IxChariot Virtualization Performance Test Plan

WHITE PAPER. Network Traffic Port Aggregation: Improved Visibility, Security, and Efficiency

Evaluating Wireless Broadband Gateways for Deployment by Service Provider Customers

Chapter 1 Reading Organizer

WHITE PAPER. Enabling 100 Gigabit Ethernet Implementing PCS Lanes

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

WHITE PAPER. Achieving Total Traffic Visibility in Enterprise and Carrier Grade Optical Networks

LAN Switching and VLANs

Guidebook to MEF Certification

WHITE PAPER. 50 versus 62.5 micron multimode fiber

WHITE PAPER. Monitoring Load Balancing in the 10G Arena: Strategies and Requirements for Solving Performance Challenges

Performance Analysis of Switches in High Speed LAN

WHITE PAPER. Net Optics Phantom Virtual Tap Delivers Best-Practice Network Monitoring For Virtualized Server Environs

WHITE PAPER. SDN Controller Testing: Part 1

WHITE PAPER. How To Compare Virtual Devices (NFV) vs Hardware Devices: Testing VNF Performance

WHITE PAPER. Gaining Total Visibility for Lawful Interception

WAN Data Link Protocols

The Economics of Cisco s nlight Multilayer Control Plane Architecture

Network Layer: Network Layer and IP Protocol

An Executive Brief for Network Security Investments

Exhibit n.2: The layers of a hierarchical network

CHAPTER 6 NETWORK DESIGN

EBOOK. Software Defined Networking (SDN)

Indian Institute of Technology Kharagpur. TCP/IP Part I. Prof Indranil Sengupta Computer Science and Engineering Indian Institute of Technology

Ethernet. Ethernet Frame Structure. Ethernet Frame Structure (more) Ethernet: uses CSMA/CD

Switch Fabric Implementation Using Shared Memory

Taps vs. SPAN The Forest AND the Trees: Full Visibility into Today's Networks

Note! The problem set consists of two parts: Part I: The problem specifications pages Part II: The answer pages

Data Communication and Computer Network

Leveraging Access Switching For HPC Monitoring & Security

Ensuring Success in a Virtual World: Demystifying SDN and NFV Migrations

Wide Area Networks. Learning Objectives. LAN and WAN. School of Business Eastern Illinois University. (Week 11, Thursday 3/22/2007)

Ethernet Fabric Requirements for FCoE in the Data Center

WHITE PAPER. Packet Time Monitoring in Your Visibility Architecture

UNIVERSIDAD FRANCISCO DE PAULA SANTANDER DOMINIOS DE COLISION, SEGMENTACION Y VLAN. Academia Local. Ing. José Martín Calixto Cely

Data Center Automation - A Must For All Service Providers

Lab Testing Summary Report

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

LAN Switching Computer Networking. Switched Network Advantages. Hubs (more) Hubs. Bridges/Switches, , PPP. Interconnecting LANs

PART III. OPS-based wide area networks

Howstuffworks "How LAN Switches Work" Click here to go back to the normal view!

Transparent LAN Services Offer Visible Benefits

WHITE PAPER. Tap Technology Enables Healthcare s Digital Future

Guide to TCP/IP, Third Edition. Chapter 3: Data Link and Network Layer TCP/IP Protocols

Reduce Your Network's Attack Surface

WHITE PAPER. Best Practices for Eliminating Duplicate Packets

ESSENTIALS. Understanding Ethernet Switches and Routers. April 2011 VOLUME 3 ISSUE 1 A TECHNICAL SUPPLEMENT TO CONTROL NETWORK

The OSI Model: Understanding the Seven Layers of Computer Networks

Improving Quality of Service

Network Expansion Devices, Switches & Routers

Arista Application Switch: Q&A

Fibre Channel over Ethernet: Enabling Server I/O Consolidation

Channel Xcelerate. Full Speed Ahead. The Ixia Channel Xcelerate Program - The Americas. Application Performance and Security Resilience

WHITE PAPER. Best Practices for Deploying IPv6 over Broadband Access

Fiber Channel Over Ethernet (FCoE)

Final for ECE374 05/06/13 Solution!!

Asynchronous Transfer Mode: ATM. ATM architecture. ATM: network or link layer? ATM Adaptation Layer (AAL)

WHITE PAPER. Best Practices in Deploying Converged Data Centers

APPLICATION NOTE 183 RFC 2544: HOW IT HELPS QUALIFY A CARRIER ETHERNET NETWORK. Telecom Test and Measurement. What is RFC 2544?

Testing Packet Switched Network Performance of Mobile Wireless Networks IxChariot

Protocols and Architecture. Protocol Architecture.

Data Link Protocols. TCP/IP Suite and OSI Reference Model

ADVANCED NETWORK CONFIGURATION GUIDE

FULL SPEED AHEAD THE IXIA CHANNEL XCELERATE PROGRAM LATIN AMERICA

Customer White paper. SmartTester. Delivering SLA Activation and Performance Testing. November 2012 Author Luc-Yves Pagal-Vinette

The Impact of QoS Changes towards Network Performance

BCS THE CHARTERED INSTITUTE FOR IT. BCS HIGHER EDUCATION QUALIFICATIONS BCS Level 5 Diploma in IT COMPUTER NETWORKS

Best Practices for Network Monitoring

RoCE vs. iwarp Competitive Analysis

Switching in an Enterprise Network

10-/100-Mbps Ethernet Media Access Controller (MAC) Core

RFC 2544 Testing of Ethernet Services in Telecom Networks

Clearing the Way for VoIP

Scaling 10Gb/s Clustering at Wire-Speed

High-Level Data Link Control

Innovate, Integrate, Lead

Introduction to Ethernet

10/100/1000 Ethernet MAC with Protocol Acceleration MAC-NET Core

Note! The problem set consists of two parts: Part I: The problem specifications pages Part II: The answer pages

10 Gigabit Ethernet: Scaling across LAN, MAN, WAN

THE IMPORTANCE OF TESTING TCP PERFORMANCE IN CARRIER ETHERNET NETWORKS

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks. Aggregation and Filtering DATA SHEET

Advancements in field measurement of Ethernet performance

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

From Fieldbus to toreal Time Ethernet

RARP: Reverse Address Resolution Protocol

Gigabit Ethernet. Abstract. 1. Introduction. 2. Benefits of Gigabit Ethernet

Master Course Computer Networks IN2097

Verifying Network Bandwidth

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

WAN. Introduction. Services used by WAN. Circuit Switched Services. Architecture of Switch Services

AlliedWare Plus OS How To Use sflow in a Network

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

WHITE PAPER. Testing Voice over IP (VolP) Networks

Transcription:

WHITE PAPER Cut-Through Ethernet Switching www.ixiacom.com 915-6908-01 Rev. A, July 2014

2

Table of Contents A Versatile Resource for Low Latency and High Performance... 4 Answering the Challenges of Latency... 4 Store-and-Forward Safer but Slower?... 4 Cut-Through Switching for a World In a Hurry... 4 Fast Forward or Not-So-Fast: Determining Which Is Right for You... 5 Holding Back Also a Wise Strategy?... 5 The Need for Speed Keeps Growing... 5 Director xstream and ilinkagg xstream : Low Latency Cut-Through Architecture for High-Performance Computing... 6 When Cut-Through Switching Is Not the Ideal Approach... 7 3

A Versatile Resource for Low Latency and High Performance Answering the Challenges of Latency Today s networks are called on to carry ever-rising volumes of triple-play services and multiprotocol traffic. With more points to monitor and soaring line speeds, the need for business-critical security, compliance, availability, and performance is putting pressure on switching speed. Latency is unacceptable, and businesses cannot afford for any links not to operate at peak performance levels. Changes to the traditional network design architecture, High Performance Computing and increased virtualization in the data center require a faster network. Changes to the traditional network design architecture, High Performance Computing (HPC) and increased virtualization in the data center require a faster network. As Layer 2 packet-handling holds the key to lowering latency, discussions always narrow on the two Ethernet switching options that perform packet forwarding: cut-through and store-andforward. When a Layer 2 Ethernet switch begins a forwarding decision, the series of steps that switch takes to determine whether to forward or drop a packet differentiates cutthrough methodology from store-and-forward. While a store-and-forward switch makes a forwarding decision on a data packet only after it has received the whole frame and checked its integrity, a cut-through switch engages in the forwarding process soon after it has examined the Destination MAC (DMAC) address of an incoming frame. Both methodologies have their uses, depending upon the application and business considerations. This paper offers some points to consider when deciding on the right approach for a customer data center. Store-and-Forward Safer but Slower? Basically, with store-and-forward switching a mature technology commonly used in traditional bridges and routers a switch receives a frame on a port, copies the whole frame into its onboard buffers and stores that frame in its memory buffer until it has been totally received. It then computes a cyclic redundancy check (CRC) and discards the frame if it contains a CRC error or if it is a runt (less than 64 bytes including the CRC) or a giant (more than 1518 bytes including the CRC). If the frame contains no errors, the LAN switch looks up the destination address in its forwarding, or switching, table and determines the outgoing interface. It then forwards the frame toward its destination. Less common but a resource to consider is Fragment-Free or runtless switching. This works similarly to cut-through but stores the first 64 bytes of the packet before sending it on. The logic behind this approach is that most errors and all collisions take place during the initial 64 bytes of a packet. Cut-through architecture results in the very low latency that s vital to High-Performance Computing environments as well as financial trading. Storeand-forward switching requires a larger buffer to accommodate and analyze an entire packet, resulting in higher latency. 4

Cut-Through Switching for a World In a Hurry Cut-through technology was developed in the 1990s as a response to issues arising in the 1980s, when networks began to slow due to the rising volume of traffic. Advances in integrated circuit technology streamlined Ethernet switching based on new applicationspecific integrated circuits (ASICs) and field-programmable gate arrays (FPGAs). These dramatically reduced packet-handling time. Cut-through switching is not fussy: it forwards a frame almost the (micro)second it has been received, hanging onto it only long enough to read the Destination Media Access Control (DMAC). It performs no error checking because it starts forwarding the frame after the first six bytes. Fast Forward or Not-So-Fast: Determining Which Is Right for You The logic is obvious: If an application demands ultra-low-latency (end-to-end latency of about 10 microseconds), then cut-through switching is the right fit. But such factors as port density and cost, as well as the capabilities of the current technology must also be taken into consideration. In many data centers, latency and jitter (delay variation) are the determining metrics. Even small amounts of latency or jitter can have a severe impact on application performance. In the data center and inside the LAN, where devices are close together, every microsecond counts. And latency is no friend to HPC applications: the more transactions an organization can process in a given time frame, the more revenue it can expect. More time and fewer transactions equals lower revenue. In many data centers, latency and jitter (delay variation) are the determining metrics. Holding Back Also a Wise Strategy? Ensuring that a packet is free of physical and data-link errors before forwarding may be a smart move under certain circumstances. However, as network throughput increases, the cut-through method is preferred more and more in switch design. Holding packets up while the store-and-forward method performs its checks is often less than ideal for today s impatient world. However, to be fair, the ingress buffering process of store-and-forward switching provides flexibility to support a diverse mix of Ethernet speeds, starting with 10 Mbps. Store-and-forward simplifies the handling of an incoming frame to a 1 Gbps Ethernet port that must travel to a 10 Gbps interface precisely because the switch architecture stores the entire packet. So it needn t execute additional ASIC or FPGA code to evaluate the packet against an access control list (ACL); the packet is already stored in a buffer for the switch to assess reasons to allow or refuse that frame. Some might argue that store-andforward reduces error rate, but this may be merely an implementation issue. The Need for Speed Keeps Growing Cut-through switching flags but does not get the chance to drop invalid packets. Packets with physical or data-link-layer errors are forwarded to other segments of the network. At the receiving end, a host can then invalidate the Frame Check Sequence (FCS) of the packet and drop the packet. 5

Both store-and-forward and cut-through Layer 2 switches base their forwarding decisions on the DMAC address of data packets. They also learn MAC addresses as they examine the source MAC (SMAC) fields of packets as stations communicate with other nodes on the network. A cut-through switch theoretically makes its forwarding decision the moment it has looked up the DMAC address of a data packet, without having to await the rest of the packet. However, in reality, it can afford to wait until a few more bytes have arrived. In fact, newer cut-through switches can collect more information about an incoming packet and make a better-informed decision even approaching the wisdom of the store-and-forward methodology. For example, Cisco s advances in ASIC design now enable improved cutthrough functions that, along with load balancing and other capabilities, allow low-latency switching while preserving the inspection benefits of store-and forward.. Newer cut-through switches can collect more information about an incoming packet and make a better-informed decision. Director xstream and ilinkagg xstream : Low Latency Cut-Through Architecture for High- Performance Computing These two Net Optics solutions are engineered for the ultra-low latency that enables monitoring solutions for today s and tomorrow s needs. The following diagram illustrates the architecture advantages of cut-through switching: Packet size in bytes 9600 6400 0.6.µs 0.6.µs 3400 0.6.µs 1518 0.6.µs 64 0.6.µs 0.µs 4.0µs 8.0µs 12.0µs 16.0µs Cut-Through Archictecture Ultra-low latency Packet size in bytes 9600 12.µs 6400 10.µs 3400 8.µs 1518 4.µs 64 2.µs 0.µs Store-and-Forward 4.0µs 8.0µs 12.0µs 16.0µs Latency 6

Read about cut-through switching in the Net Optics e-book, The Top 5 Ways to Enhance Your Cisco Environment. Download it at www.netoptics.com/elibrary When Cut-Through Switching Is Not the Ideal Approach Certainly, store-and-forward switching delays the time it takes for the frame to get from source to destination. That s because it waits to forward a frame until it has received the entire frame and checked it for errors, comparing the last field of the datagram against its own frame-check-sequence (FCS) calculations. So that additional time is spent ensuring that the packet is purged of physical and data-link errors. Invalid packets are dropped while a cut-through device would simply forward them on. Also, a store-and-forward switch can perform ingress buffering for the flexibility to support any mix of Ethernet speeds. Regarding Director xstream s behavior in cut-through mode: Disabling CRC and jumbo packet forwarding causes changes in behavior. The reason is that packets are already being transmitted from the output port by the time the chip can determine that a CRC error or jumbo packet condition exists. At that point, the chip truncates transmission of the packet. In the case of a packet with a CRC error, most of the packet has already been transmitted. A jumbo packet is truncated after 1524 bytes have been transmitted. It is recommended that a user operate with CRC forwarding and jumbo packet forwarding enabled to prevent confusion. Each organization must determine the choices and mixes of store-and-forward or cutthrough switching that best fit its unique environment. For HPC applications, the decision is fairly easy: reduce latency to the lowest possible levels in order to stay competitive. HPC enterprises include entertainment, oil and gas exploration, aerospace and biosciences, financial data mining, government research and climate/weather simulation. Find out more about how Net Optics helps you make the right decision about gaining the benefits of cut-through switching in your network. Visit www.netoptics.com or contact us at (408) 737-7777. Each organization must determine the choices and mixes of store-andforward or cutthrough switching that best fit its unique environment. 7

WHITE PAPER Ixia Worldwide Headquarters 26601 Agoura Rd. Calabasas, CA 91302 (Toll Free North America) 1.877.367.4942 (Outside North America) +1.818.871.1800 (Fax) 818.871.1805 www.ixiacom.com Ixia European Headquarters Ixia Technologies Europe Ltd Clarion House, Norreys Drive Maidenhead SL6 4FL United Kingdom Sales +44 1628 408750 (Fax) +44 1628 639916 Ixia Asia Pacific Headquarters 21 Serangoon North Avenue 5 #04-01 Singapore 554864 Sales +65.6332.0125 Fax +65.6332.0127 915-6908-01 Rev. A, July 2014