WHITE PAPER. Enabling 100 Gigabit Ethernet Implementing PCS Lanes
|
|
|
- Phebe Lucas
- 10 years ago
- Views:
Transcription
1 WHITE PAPER Enabling 100 Gigabit Ethernet Implementing PCS Lanes Rev. C, January 2014
2 2
3 Table of Contents Introduction... 4 The IEEE Protocol Stack... 4 PCS Layer Functions... 5 Striping... 6 The Need for PCS Lanes... 7 Multiplexing of PCS Lanes... 8 Testing Challenges... 9 Receiver Testing... 9 PCS lane alignment marker lock... 9 Skew tolerance and compensation...10 Arbitrary mapping of transmitted to received PCS lanes...10 Transmit-Side Testing Ixia and PCS Summary
4 Introduction Advances in data center technology and Internet usage have pushed enterprise data centers from Gigabit Ethernet links to 10 Gigabit Ethernet (GbE) links and search engines/ carriers/isps from single 10 GbE links to multiple links. Projected growth indicates the need for higher-speed Internet connections1. The IEEE 802.3ba task force has been established with the objective of standardizing 100 GbE and 40 GbE over the Internet and within the data center. Advances in data center technology and Internet usage have pushed enterprise data centers from Gigabit Ethernet links to 10 Gigabit Ethernet (GbE) links and search engines/ carriers/isps from single 10 GbE links to multiple links. If higher-speed Ethernet is to be useful in the near term, implementations must take advantage of existing copper and fiber cables, both in the data center and over the Internet. This poses an interesting problem since no technology currently exists to transport 100 Gbps or 40 Gbps as a single stream over either media. In order to transport 100 GbE over single-mode fibers, for example, 4 different wavelengths will be required using LAN wavelength-division multiplexing ( LAN WDM). Similarly, the device interfaces found in routers, switches and servers that drive these higher-speed links cannot currently handle single 100 Gbps or 40 Gbps data streams. They will be forced to resort to parallel electrical lanes to handle the flow of data; for example, 10 lanes of 10 Gbps. As technology improves, the bandwidth of fiber wavelengths and electrical lanes will increase at independent rates. Efficient 100 and 40 GbE links will need to handle a number of combinations. A technique is needed to allow efficient implementation that allows for changing numbers and bandwidths of wavelengths and electrical lanes. Within the Ethernet specification, the protocol stack layer that performs this function is called the physical coding sublayer, or PCS. This white paper describes the baseline proposal for the physical coding sublayer (PCS) for the 100-Gbps and 40-Gbps Ethernet interfaces currently under standardization within the IEEE 802.3ba task force. The IEEE Protocol Stack Figure 1 shows a simplified version of the standard IEEE protocol stack The subject of this paper relates the PCS layer and the unique requirements for 100 Gbps Ethernet. Media Access Control (MAC) Reconciliation Sublayer Media Independent Interface (MII) Physical Coding Sublayer (PCS) Physical Medium Attachment (PMA) Physical Medium Dependent (PMD) Simplified IEEE protocol stack 1) Schneider, David. An Overview of Next-Generation 100 and 40 Gigabit Ethernet Technologies. Available at 4
5 Figure 2 shows the architectural partition for a 100 Gbps Ethernet link. The partitioning assumes: A highly integrated 100 GbE MAC/PCS chip that includes the packet interface and MAC, PCS, and PMA functions. An optical module that includes both PMA and PMD functions. A high-speed parallel electrical interface comprising n lanes between the MAC/PCS chip and the optical module. A parallel optical interface comprising m lanes, where lanes can be wavelengths or fibers. 100 GbE ASIC 100 GbE Optical Module 100 GbE Optical Module 100 GbE ASIC Packet Interface Media Access Control (MAC) Physical Coding Sublayer (PCS) Physical Medium Attachment 1 (PMA 1 ) n Physical Medium Attachment 2 (PMA 2 ) Physical Medium Dependant (PMD) m Physical Medium Dependant (PMD) Physical Medium Attachment 2 (PMA 2 ) n Physical Medium Attachment 1 (PMA 1 ) Physical Coding Sublayer (PCS) Media Access Control (MAC) Packet Interface PCS Layer Functions The requirements for the PCS layer include: Architectural partition for a 100 GbE link Provide frame delineation Control signal transport Provide the clock transitions needed by SerDes-style electrical and optical interface Bond multiple lanes together through a striping or fragmentation methodology Since the data must travel on multiple optical lanes as well as on multiple electrical lanes to the optical module, the striping mechanism should support: Low frame overhead that is independent of frame size Formatting that enables receiver-only lane deskew Evolving media and media interface widths Simple optical module implementations 5
6 Striping Where the number of electrical and optical lanes is the same, a simple striping of 66-bit blocks across the lanes is sufficient, as shown in Figure 3 for four electrical lanes. Incoming Stream from MII Transmit PCS bit block A A A A Outgoing Electrical Lanes Simple striping of data The transmitting PCS first performs 64/66b encoding on the incoming stream. The 66- bit blocks are distributed across the lanes on a round-robin basis. An alignment block is periodically added as a marker that allows the receive side to deskew the lanes. This allows the receiver to remove skew between the individual media lanes. Bandwidth for the alignment blocks is created by periodically deleting inter-packet gaps. Line coding is implemented once at the aggregate level in the transmitting PCS block using a single scrambler in such a way as to ensure adequate transition density on any of the individual electrical and media lanes along the path. The deskew function is also only implemented once in the receiving PCS block, and again in such a way as to compensate for skew introduced over any of the electrical or optical interfaces along the path. The advantages of this approach are obvious; it moves all of the scrambling and deskew features into a CMOS chip, where they are easy and cheap to implement, and therefore significantly simplifies the design of the optical module. 6
7 The Need for PCS Lanes As discussed earlier, advancing electrical and optical technologies will require the ability to handle differing and changing numbers of electrical interface lanes versus optical lanes. To handle the general case, the PCS baseline proposal calls for data to be distributed on a per-66-bit block basis to a number of PCS lanes v, where the number of PCS lanes equals the least common multiple of the number of electrical lanes n and optical lanes m. Using the virtual lane concept, the optical module can be a very simple multiplexer, which merely bit multiplexes the data from n electrical lanes down to m media lanes. The receiver s PCS block can simply demultiplex the data back into the PCS lanes and then realign the skewed data. A virtual lane is a continuous stream of 64/66b blocks. PCS lanes are created through a simple round-robin function which distributes 66-bit blocks, in order, to each virtual lane. In the case of an interface running with 20 PCS lanes, a single virtual lane would contain every 20th 66-bit block from the aggregate signal, as illustrated in Figure 4 below. In order to allow the receiver to identify and deskew the individual PCS lanes, a unique alignment block is added to each virtual lane on a periodic basis. The alignment block is a special 66-bit control signal block that is unique to each virtual lane and cannot be duplicated in the data. The current proposal under consideration calls for an alignment block once every 16,384 blocks on each virtual lane. The number of PCS lanes required depends on the electrical and optical lane combinations that need to be supported. The number of PCS lanes is the least common multiple of the number of electrical lanes and the number of optical lanes, regardless of whether the lanes are based on numbers of wavelengths, numbers of fibers, or other considerations. This constraint ensures that the total number of PCS lanes can be mapped evenly over both the number of electrical lanes and the number of optical lanes; therefore, the data from any particular virtual lane will always reside on the same electrical and media lane across the link. This guarantees that no skew can be introduced between the bits within a virtual lane, which would be impossible to remove at the receiver. As discussed earlier, advancing electrical and optical technologies will require the ability to handle differing and changing numbers of electrical interface lanes versus optical lanes. #2n+1 #n+1 #1 virtual lane 1 #2n+2 #n+2 #2 virtual lane Gbps aggregate stream of 64/66b words #2n+3 #n+3 #3 virtual lane 3 #2n+1 #2n #n+3 #n+2 #n+1 #n #3 #2 #1 Simple 66-bit word level round robin distribution #3n #2n #n virtual lane n virtual lane markers Virtual lane data distribution 7
8 Multiplexing of PCS Lanes Virtual lane muxing is straightforward, consisting of bit-interleaving of all of the PCS lanes assigned to a particular electrical or optical lane and is performed in the PMA layer. Figure 6 illustrates a case with: 20 PCS lanes 10 electrical lanes 4 media lanes In Figure 5, VL stands for virtual lane and the nomenclature n.m indicates virtual lane n, bit m. The PCS layer created the 20 PCS lanes from the data source flow, as covered above. The PCS layer bit-multiplexes each pair of PCS lanes into a single lane and sends 10 electrical lanes to the PMA in the optical module. The optical device s PMA then bitmultiplexes the 10 electrical lanes into the 4 optical lanes. Virtual lane muxing is straightforward, consisting of bitinterleaving of all of the PCS lanes assigned to a particular electrical or optical lane and is performed in the PMA layer. Due to skew on the electrical interface, the random startup state of the bit multiplexers and demultiplexers is in not predictable where PCS lanes will end up in the receive PCS. The unique alignment words, however, provide the means by which the receive PCS layer identifies and reorders the individual PCS lanes. VL0 VL1 VL2 Transmit PCS VL Transmit PMA Transmit PMD Receive PMD Receive PMA Receive PCS Multiplexing of PCS lanes to optical media 8
9 Testing Challenges As with any new technology, 100 GbE testing will be a significant challenge. Although this paper largely concentrates on PCS layer testing issues, it s important to note that layer 2 through 7 testing is as important as ever. The 100 GbE and 40 GbE links will be incorporated in switches, routers, and servers almost immediately. It s important that real-world traffic be used to properly exercise the network device/server, to determine if it can properly sustain traffic over multiple high speed links. The 100 GbE interfaces must operate in an integrated manner with lower-speed interfaces. As with every new standard, multiple companies will develop products that will conform to pre-standards and then to published standards. Proper test tools are needed to allow each vendor to independently assess their conformance to standards that will lead to high assurance of interoperability. The alternative approaches are back-to-back with one s own equipment or limited interoperability testing with other vendor s equipment. The former is self-deceptive, allowing a vendor to make the same mistakes in both transmit and receive functions. The latter is expensive and endlessly frustrating, due to multiple vendors updates. Receiver Testing Concentrating on just the receiver side of the PCS layer, major test considerations include: 64/66b word sync lock Virtual lane alignment marker lock Skew tolerance and compensation Arbitrary mapping of received to transmitted PCS lanes 64/66b Word Sync Lock Each received virtual lane must properly identify 64/66b blocks, based on the control bits. The receive logic must properly lock and come out of lock under conditions covered in the specification. In order to measure conformance, various bit sequences at the limits of the specification must be transmitted by the test equipment. The receiver of the interface under test must then be subjected to intentionally errored sync bits and out-of-sync detection must be verified. Additionally, a variety of intentionally errored patterns must be applied to also ensure that the receiver does not improperly sync. It s important that real-world traffic be used to properly exercise the network device/ server, to determine if it can properly sustain traffic over multiple high speed links. PCS lane alignment marker lock Each virtual lane must correctly lock onto alignment markers. The techniques used here are analogous to those used in 64/66b word sync lock testing. Boundary conditions need to be verified in addition to basic locking operations. For example, if the specification calls for virtual lane lock after n consecutive non-errored alignment markers, then testing must ensure that lock is not declared with any fewer alignment markers. Conversely, if virtual lane lock should be dropped with m consecutive errored alignment markers, then testing must ensure that lock is maintained with fewer errored alignment markers. 9
10 Skew tolerance and compensation Skew at various electrical and optical interfaces causes PCS lanes to arrive with different delays relative to other PCS lanes. The virtual lane alignment markers are designed to make it possible for received PCS lanes to identify and realign themselves properly. In order to test skew tolerance and compensation algorithms, test equipment must introduce known, specific amounts of skew amongst the PCS lanes. The receiver s PCS layer should be able compensate for the skew mandated in the standard. Test equipment must also be used to measure the actual skew tolerance when it exceeds the specifications. Arbitrary mapping of transmitted to received PCS lanes As shown in Figure 6, a particular virtual lane may be transmitted on any of a number of optical lanes and then received in any virtual lane position. The red lines trace a set of the possible paths for virtual lane 0. The virtual lane concept, in fact, does not require that the number of physical lanes on the transmit and receive paths match. To make matters worse, there is no requirement to enforce where specific PCS lanes are mapped along the transmit or receive path. The only requirement is for all transmitted bits on a given virtual lane to end up together on the same physical receive lane. When there is an incongruity, which will occur as the various vendors transmit and receive ASICs and optical modules proliferate, transmitted PCS lanes can appear on any received virtual lane. Receivers must be able to reorder and reassemble any mapping of PCS lanes into a single 100 Gbps aggregated stream. In order to exercise this reordering, test equipment must be able to transmit PCS lanes in any order to emulate differing scenarios. Transmit PCS Electrical Lanes PMA PMD Optical Lanes PMD PMA Electrical Lanes 1:2 1:2 1:2 1:2 1:2 1:2 1:2 1:2 1:2 1:2 Virtual Lanes Lane ordering requires lane identification Receive PCS 10
11 Transmit-Side Testing Transmit-side testing consists of verification and monitoring or various signal attributes: 64/66b sync bits. Proper transmission of sync bits must be determined and then monitored. Counts of erroneous sync bits must be available in real time during testing. Virtual lane alignment markers. Proper transmission of alignment markers must be verified and monitored, with error counts available. Lane skew. Actual lane skew must be measured and reported. Virtual lane mapping. The actual mapping of transmitted to received PCS lanes must be identified and reported. Ixia and PCS Ixia has been actively working with the IEEE 802.3ba task force. On June 17th, 2008 Ixia demonstrated the first PCS hardware implementation at NXTcomm08. The demonstration used Ixia s proof of concept 100 GbE implementation to generate and receive line-rate traffic, which was sent round-trip from Las Vegas to Los Angeles, and to analyze the results. At Interop 2009, Ixia showed the world s first 100G IP test module with a CFP interface. The 100 GbE interface card works in conjunction and in the same manner as all other Ixia interface cards and test applications, making it possible to test all types of devices and networks from layer 2 through 7. Summary 100 GbE and 40 GbE technologies are rapidly approaching standardization and deployment. 100 GbE and 40 GbE technologies are rapidly approaching standardization and deployment. A key factor in their success will be ability to utilize existing fiber and copper media in an environment of advancing technologies. The physical coding sublayer (PCS) of the architecture is in a perfect position to facilitate this flexibility. The current baseline proposal for PCS implementation uses a unique virtual lane concept that provides the mechanism to handle differing electrical and optical paths. Testing of this technology, however, will require refined and sophisticated test methodologies and equipment. 11
12 WHITE PAPER Ixia Worldwide Headquarters Agoura Rd. Calabasas, CA (Toll Free North America) (Outside North America) (Fax) Ixia European Headquarters Ixia Technologies Europe Ltd Clarion House, Norreys Drive Maidenhead SL6 4FL United Kingdom Sales (Fax) Ixia Asia Pacific Headquarters 21 Serangoon North Avenue 5 #04-01 Singapore Sales Fax Rev. C, January 2014
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview June 2010 Authors: John D Ambrosia, Force10 Networks David Law, 3COM Mark Nowell, Cisco Systems 1. This work represents the opinions of
WHITE PAPER. Static Load Balancers Implemented with Filters
WHITE PAPER Static Load Balancers Implemented with Filters www.ixiacom.com 915-6911-01 Rev. A, July 2014 2 Table of Contents Load Balancing of Monitoring Systems as a Key Strategy for Availability, Security
WHITE PAPER. Extending Network Monitoring Tool Performance
WHITE PAPER Extending Network Monitoring Tool Performance www.ixiacom.com 915-6915-01 Rev. A, July 2014 2 Table of Contents Benefits... 4 Abstract... 4 Introduction... 4 Understanding Monitoring Tools...
WHITE PAPER. Addressing Monitoring, Access, and Control Challenges in a Virtualized Environment
WHITE PAPER Addressing Monitoring, Access, and Control Challenges in a Virtualized Environment www.ixiacom.com 915-6892-01 Rev. A, July 2014 2 Table of Contents The Challenge of the Virtual Environment...
White Paper. An Overview of Next-Generation 100 and 40 Gigabit Ethernet Technologies
White Paper An Overview of Next-Generation 100 and 40 Gigabit Ethernet Technologies 26601 Agoura Road, Calabasas, CA 91302 Tel: 818.871.1800 Fax: 818.871.1805 www.ixiacom.com 915-0908-01 Rev D, September
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview
40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview November 2008 Authors: John D Ambrosia, Force10 Networks David Law, 3COM Mark Nowell, Cisco Systems 1. This work represents the opinions
IxChariot Virtualization Performance Test Plan
WHITE PAPER IxChariot Virtualization Performance Test Plan Test Methodologies The following test plan gives a brief overview of the trend toward virtualization, and how IxChariot can be used to validate
802.3bj FEC Overview and Status. 400GbE PCS Options DRAFT. IEEE P802.3bs 400 Gb/s Ethernet Task Force. November 2014 San Antonio
802.3bj FEC Overview and Status 400GbE PCS Options DRAFT IEEE P802.3bs 400 Gb/s Ethernet Task Force November 2014 San Antonio Mark Gustlin Xilinx Gary Nicholl Cisco Dave Ofelt Juniper Steve Trowbridge
WHITE PAPER. Gaining Total Visibility for Lawful Interception
WHITE PAPER Gaining Total Visibility for Lawful Interception www.ixiacom.com 915-6910-01 Rev. A, July 2014 2 Table of Contents The Purposes of Lawful Interception... 4 Wiretapping in the Digital Age...
EBOOK. The Network Comes of Age: Access and Monitoring at the Application Level
EBOOK The Network Comes of Age: Access and Monitoring at the Application Level www.ixiacom.com 915-6948-01 Rev. A, January 2014 2 Table of Contents How Flow Analysis Grows Into Total Application Intelligence...
WHITE PAPER. Net Optics Phantom Virtual Tap Delivers Best-Practice Network Monitoring For Virtualized Server Environs
WHITE PAPER Net Optics Phantom Virtual Tap Delivers Best-Practice Network Monitoring For Virtualized Server Environs www.ixiacom.com 915-6909-01 Rev. A, July 2014 2 Table of Contents Event... 4 Context...
Guidebook to MEF Certification
WHITE PAPER Guidebook to MEF Certification www.ixiacom.com Rev A September 2012, 915-6015-01 2 Table of Contents Introduction... 4 Benefits of Certification... 7 Overview... 7 Equipment Vendor... 7 Service
WHITE PAPER. 50 versus 62.5 micron multimode fiber
WHITE PAPER 50 versus 62.5 micron multimode fiber www.ixiacom.com 915-6919-01 Rev. A, July 2014 2 Table of Contents What are 50μm fiber and 62.5μm fiber?... 4 Why two standards?... 4 Which technology should
Evaluating Wireless Broadband Gateways for Deployment by Service Provider Customers
Evaluating Wireless Broadband Gateways for Deployment by Service Provider Customers Overview A leading provider of voice, video, and data services to the residential and businesses communities designed
10 Gigabit Ethernet: Scaling across LAN, MAN, WAN
Arasan Chip Systems Inc. White Paper 10 Gigabit Ethernet: Scaling across LAN, MAN, WAN By Dennis McCarty March 2011 Overview Ethernet is one of the few protocols that has increased its bandwidth, while
WHITE PAPER. Monitoring Load Balancing in the 10G Arena: Strategies and Requirements for Solving Performance Challenges
WHITE PAPER Monitoring Load Balancing in the 10G Arena: Strategies and Requirements for Solving Performance Challenges www.ixiacom.com 915-6914-01 Rev. A, July 2014 2 Table of Contents Load Balancing A
WHITE PAPER. Tap Technology Enables Healthcare s Digital Future
WHITE PAPER Tap Technology Enables Healthcare s Digital Future www.ixiacom.com 915-6912-01 Rev. A, July 2014 2 Table of Contents Executive Overview... 4 Introduction... 4 HIT s foundation... 5 Keeping
WHITE PAPER. Network Traffic Port Aggregation: Improved Visibility, Security, and Efficiency
WHITE PAPER Network Traffic Port Aggregation: Improved Visibility, Security, and Efficiency www.ixiacom.com 915-6893-01 Rev. A, July 2014 2 Table of Contents Summary... 4 Introduction... 4 Differing Goals
EBOOK. Software Defined Networking (SDN)
EBOOK Software Defined Networking (SDN) www.ixiacom.com 915-6885-01 Rev. A, January 2014 2 Table of Contents Your Route to Agility, Accuracy and Availability... 4 SDN Advanced, Next-Generation Networking...
High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF
High Speed Ethernet Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF Hubs and Switches Hubs and Switches Shared Medium Hub The total capacity in the shared medium hub configuration (figure
R2. The word protocol is often used to describe diplomatic relations. How does Wikipedia describe diplomatic protocol?
Chapter 1 Review Questions R1. What is the difference between a host and an end system? List several different types of end systems. Is a Web server an end system? 1. There is no difference. Throughout
How To Test For 10 Gigabit Ethernet At 10 Gb/S
White Paper Testing Scenarios for Ethernet at 10 Gb/s By Guylain Barlow Introduction As a natural evolution, the typical test concepts borrowed from lower-rate Ethernet apply to 10 Gigabit Ethernet (GigE).
WHITE PAPER. SDN Controller Testing: Part 1
WHITE PAPER SDN Controller Testing: Part 1 www.ixiacom.com 915-0946-01 Rev. A, April 2014 2 Table of Contents Introduction... 4 Testing SDN... 5 Methodologies... 6 Testing OpenFlow Network Topology Discovery...
High-Speed SERDES Interfaces In High Value FPGAs
High-Speed SERDES Interfaces In High Value FPGAs February 2009 Lattice Semiconductor 5555 Northeast Moore Ct. Hillsboro, Oregon 97124 USA Telephone: (503) 268-8000 www.latticesemi.com 1 High-Speed SERDES
White Paper. Best Practices for 40 Gigabit Implementation in the Enterprise
White Paper Best Practices for 40 Gigabit Implementation in the Enterprise 26601 Agoura Road, Calabasas, CA 91302 Tel: 818.871.1800 Fax: 818.871.1805 www.ixiacom.com 915-6506-01 Rev. B, June 2013 2 Table
What to do about Fiber Skew?
What to do about Fiber Skew? White Paper July 2008 www.commscope.com A number of years ago there was a good deal of discussion about the problem of fiber skew in high speed optical links, but the issue
40 and 100 Gigabit Ethernet Overview
40 and 100 Gigabit Ethernet Overview Abstract: This paper takes a look at the main forces that are driving Ethernet bandwidth upwards. It looks at the standards and architectural practices adopted by the
WHITE PAPER. How To Compare Virtual Devices (NFV) vs Hardware Devices: Testing VNF Performance
WHITE PAPER How To Compare Virtual Devices (NFV) vs Hardware Devices: Testing VNF Performance www.ixiacom.com 915-3132-01 Rev. B, June 2014 2 Table of Contents Network Functions Virtualization (NFV): An
Introduction. Background
Introduction By far, the most widely used networking technology in Wide Area Networks (WANs) is SONET/SDH. With the growth of Ethernet now into Metropolitan Area Networks (MANs) there is a growing need
Optimizing Infrastructure Support For Storage Area Networks
Optimizing Infrastructure Support For Storage Area Networks December 2008 Optimizing infrastructure support for Storage Area Networks Mission critical IT systems increasingly rely on the ability to handle
Reduce Your Network's Attack Surface
WHITE PAPER Reduce Your Network's Attack Surface Ixia's ThreatARMOR Frees Up Security Resources and Personnel The Threat Landscape When you re dealing with network security, one of the primary measurements
Application Note Gigabit Ethernet Port Modes
Application Note Gigabit Ethernet Port Modes Application Note Gigabit Ethernet Port Modes Table of Contents Description... 3 Benefits... 4 Theory of Operation... 4 Interaction with Other Features... 7
The Key Benefits of OTN Networks
he Key Benefits of ON Networks Introduction Optical transport networks have been migrating from SO technology to WDM architectures over the past 5 10 years. Deploying WDM systems has allowed carriers to
FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:
FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below: Title: Broadband Telecommunications Handbook Author: Regis J. Bud Bates Publisher:
25GbE: The Future of Ethernet
White Paper 25GbE: The Future of Ethernet Ixia and QLogic Validate End-to-End Interoperability of 25 Gigabit Ethernet Executive Summary/Abstract Reliance on networking permeates every aspect of our world,
Latency on a Switched Ethernet Network
Application Note 8 Latency on a Switched Ethernet Network Introduction: This document serves to explain the sources of latency on a switched Ethernet network and describe how to calculate cumulative latency
RFC 2544 Testing of Ethernet Services in Telecom Networks
RFC 2544 Testing of Ethernet Services in Telecom Networks White Paper Nigel Burgess Agilent Technologies Introduction The object of this paper is to discuss the use and testing of Ethernet services in
100BASE-SX Fast Ethernet:
100BASE-SX Fast Ethernet: A Cost Effective Migration Path for Fiber in the Horizontal Prepared by the Fiber Optics LAN Section of the Telecommunications Industry Association February 2000 2000 TIA Fiber
Using FPGAs to Design Gigabit Serial Backplanes. April 17, 2002
Using FPGAs to Design Gigabit Serial Backplanes April 17, 2002 Outline System Design Trends Serial Backplanes Architectures Building Serial Backplanes with FPGAs A1-2 Key System Design Trends Need for.
HOW TO TEST 10 GIGABIT ETHERNET PERFORMANCE
HOW TO TEST 10 GIGABIT ETHERNET PERFORMANCE March 2012 Rev. B 03/12 SPIRENT 1325 Borregas Avenue Sunnyvale, CA 94089 USA Email: Web: [email protected] www.spirent.com AMERICAS 1-800-SPIRENT +1-818-676-2683
Understanding Ethernet and Fibre Channel Standard-Based Test Patterns An explanation of IEEE 802.3 and NCITS standard test patterns By Todd Rapposelli
White Paper Understanding Ethernet and Fibre Channel Standard-Based Test Patterns An explanation of IEEE 802.3 and NCITS standard test patterns By Todd Rapposelli Overview The IEEE 802.3 standards for
How To Make A Multilink Ame Relay Work Faster And More Efficiently
1/16/01 - ick Franks / Tiara etworks nc. / [email protected] / 408-535-1222 Multilink Frame Relay Prior to the advent of the multilink ame relay () protocol, some ame relay users were experiencing
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
Interfaces and Payload Testing
application note 225 Packet Optical Transport Network Testing: From Commissioning to In-Service Monitoring Mai Abou-Shaban, Product Specialist, Transport and Datacom For network service providers considering
Data Center Design for 40/100G
Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an
Lecture 1. Lecture Overview. Intro to Networking. Intro to Networking. Motivation behind Networking. Computer / Data Networks
Lecture 1 An Introduction to Networking Chapter 1, pages 1-22 Dave Novak BSAD 146, Introduction to Networking School of Business Administration University of Vermont Lecture Overview Brief introduction
The OSI Model: Understanding the Seven Layers of Computer Networks
Expert Reference Series of White Papers The OSI Model: Understanding the Seven Layers of Computer Networks 1-800-COURSES www.globalknowledge.com The OSI Model: Understanding the Seven Layers of Computer
10 Gigabit Ethernet MAC Core for Altera CPLDs. 1 Introduction. Product Brief Version 1.4 - February 2002
1 Introduction Initially, network managers use 10 Gigabit Ethernet to provide high-speed, local backbone interconnection between large-capacity switches. 10 Gigabit Ethernet enables Internet Service Providers
New WAN PHY Approach Proposals
New WAN Approach Proposals Feed Forward Rate Control (FFRC) & 10Gigabit Ethernet Network Interface Extension (10GENIE) IEEE P802.3ae 6-10 March, 2000 Albuquerque, NM Osamu ISHIDA and Haruhiko ICHINO NTT
Clearing the Way for VoIP
Gen2 Ventures White Paper Clearing the Way for VoIP An Alternative to Expensive WAN Upgrades Executive Overview Enterprises have traditionally maintained separate networks for their voice and data traffic.
Communications and Computer Networks
SFWR 4C03: Computer Networks and Computer Security January 5-8 2004 Lecturer: Kartik Krishnan Lectures 1-3 Communications and Computer Networks The fundamental purpose of a communication system is the
WHITE PAPER. Best Practices for Deploying IPv6 over Broadband Access
WHITE PAPER Best Practices for Deploying IPv6 over Broadband Access www.ixiacom.com 915-0123-01 Rev. C, December 2013 2 Table of Contents Udi cusciamenis minctorpos... 4 Toreptur aut dolo cone verum aute
FOUNDATION Fieldbus High Speed Ethernet Control System
FOUNDATION Fieldbus High Speed Ethernet Control System Sean J. Vincent Fieldbus Inc. Austin, TX, USA KEYWORDS Fieldbus, High Speed Ethernet, H1, ABSTRACT FOUNDATION fieldbus is described in part by the
Chap 4 Circuit-Switching Networks
hap 4 ircuit-switching Networks Provide dedicated circuits between users Example: 1. telephone network: provides 64Kbps circuits for voice signals 64Kbps=8 k samples/sec * 8 bits/sample 2. transport network:
INTRODUCTION TO 100BASE-T: FAST (AND FASTER) ETHERNET
51-20-97 DATA COMMUNICATIONS MANAGEMENT INTRODUCTION TO 100BASE-T: FAST (AND FASTER) ETHERNET Colin Mick INSIDE How It Works: An Iso View, 100BASE-TX, 100BASE-T4, 100BASE-T2, Gigabit Ethernet, Impacts
SummitStack in the Data Center
SummitStack in the Data Center Abstract: This white paper describes the challenges in the virtualized server environment and the solution Extreme Networks offers a highly virtualized, centrally manageable
Local Area Networks. Guest Instructor Elaine Wong. Elaine_06_I-1
Local Area Networks Guest Instructor Elaine Wong Elaine_06_I-1 Outline Introduction to Local Area Networks (LANs) Network architecture Geographical area LAN applications LAN Technologies Ethernet Fiber
Ethernet/IEEE 802.3 evolution
Ethernet/IEEE 802.3 evolution Pietro Nicoletti www.studioreti.it 8023-Evolution-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties.
Performance Management and Fault Management. 1 Dept. of ECE, SRM University
Performance Management and Fault Management 1 Dept. of ECE, SRM University Performance Management Performance management requires monitoring of the performance parameters for all the connections supported
Chapter 2 - The TCP/IP and OSI Networking Models
Chapter 2 - The TCP/IP and OSI Networking Models TCP/IP : Transmission Control Protocol/Internet Protocol OSI : Open System Interconnection RFC Request for Comments TCP/IP Architecture Layers Application
Ensuring Success in a Virtual World: Demystifying SDN and NFV Migrations
Ensuring Success in a Virtual World: Demystifying SDN and NFV Migrations Get Migration Right the First Time The virtualization of traditional networks promises vast and enduring benefits if the challenges
SummitStack in the Data Center
SummitStack in the Data Center Abstract: This white paper describes the challenges in the virtualized server environment and the solution that Extreme Networks offers a highly virtualized, centrally manageable
Taps vs. SPAN The Forest AND the Trees: Full Visibility into Today's Networks
WHITE PAPER Taps vs. SPAN The Forest AND the Trees: Full Visibility into Today's Networks www.ixiacom.com 915-3534-01 Rev. A, September 2015 2 Table of Contents The First Line of Defense: Access... 5 Problem
How To Understand The Layered Architecture Of A Network
COMPUTER NETWORKS NETWORK ARCHITECTURE AND PROTOCOLS The Need for Standards Computers have different architectures, store data in different formats and communicate at different rates Agreeing on a particular
Steve Worrall Systems Engineer. [email protected]
Steve Worrall Systems Engineer [email protected] Agenda 100GbE Load sharing/link aggregation Foundry Direct Routing 2 100 Gigabit Ethernet 3 Current Status PAR approved, 802.3ba task force set up
WHITE PAPER. Best Practices in Deploying Converged Data Centers
WHITE PAPER Best Practices in Deploying Converged Data Centers www.ixiacom.com 915-2505-01 Rev C October 2013 2 Contents Introduction... 4 Converged Data Center... 4 Deployment Best Practices... 6 Testing
Master Course Computer Networks IN2097
Chair for Network Architectures and Services Prof. Carle Department for Computer Science TU München Master Course Computer Networks IN2097 Prof. Dr.-Ing. Georg Carle Christian Grothoff, Ph.D. Chair for
Computer Network. Interconnected collection of autonomous computers that are able to exchange information
Introduction Computer Network. Interconnected collection of autonomous computers that are able to exchange information No master/slave relationship between the computers in the network Data Communications.
AN OVERVIEW OF QUALITY OF SERVICE COMPUTER NETWORK
Abstract AN OVERVIEW OF QUALITY OF SERVICE COMPUTER NETWORK Mrs. Amandeep Kaur, Assistant Professor, Department of Computer Application, Apeejay Institute of Management, Ramamandi, Jalandhar-144001, Punjab,
An Executive Brief for Network Security Investments
An Executive Brief for Network Security Investments Implementing network security resilience is one of the few things that you can do that will: Protect company brand value Decrease operational costs Preserve
Overview of Requirements and Applications for 40 Gigabit and 100 Gigabit Ethernet
Overview of Requirements and Applications for 40 Gigabit and 100 Gigabit Ethernet Version 1.1 June 2010 Authors: Mark Nowell, Cisco Vijay Vusirikala, Infinera Robert Hays, Intel 1. This work represents
Ethernet Passive Optical Networks EPON
Ethernet Passive Optical Networks EPON IEEE 802.3 Ethernet in the First Mile Study Group January 8-9, 2001, Irvine, CA Gerry Pesavento Alloptic, Inc. Tel 925-245-7647 Email [email protected]
LAN and WAN Rate 10 GigE
LAN and WAN Rate 10 GigE IEEE 802.3 Sept. 27, 1999 Paul A. Bottorff Nortel Networks 1 Agenda A 2 PHYs Solution is the Way To Go LAN PHY compatible with LAN market LAN PHY provides connections up to 40
Fibre Channel over Ethernet in the Data Center: An Introduction
Fibre Channel over Ethernet in the Data Center: An Introduction Introduction Fibre Channel over Ethernet (FCoE) is a newly proposed standard that is being developed by INCITS T11. The FCoE protocol specification
Monitoring Service Delivery in an MPLS Environment
Monitoring Service Delivery in an MPLS Environment A growing number of enterprises depend on (or are considering) MPLS-based routing to guarantee high-bandwidth capacity for the real-time applications
Virtual Private LAN Service (VPLS) Conformance and Performance Testing Sample Test Plans
Virtual Private LAN Service (VPLS) Conformance and Performance Testing Sample Test Plans Contents Overview...3 1. VPLS Traffic CoS Test...3 2. VPLS VSI Isolation Test...5 3. VPLS MAC Address Purge Test...7
WHITE PAPER. Best Practices for Eliminating Duplicate Packets
WHITE PAPER Best Practices for Eliminating Duplicate Packets 26601 Agoura Road, Calabasas, CA 91302 Tel: 818.871.1800 Fax: 818.871.1805 www.ixiacom.com 915-6501-01 Rev. B, July 2013 Table of Contents
Unified Storage Networking
Unified Storage Networking Dennis Martin President Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers, networking and storage infrastructure Fibre Channel:
Auspex Support for Cisco Fast EtherChannel TM
Auspex Support for Cisco Fast EtherChannel TM Technical Report 21 Version 1.0 March 1998 Document 300-TC049, V1.0, 980310 Auspex Systems, Inc. 2300 Central Expressway Santa Clara, California 95050-2516
Local Area Networks transmission system private speedy and secure kilometres shared transmission medium hardware & software
Local Area What s a LAN? A transmission system, usually private owned, very speedy and secure, covering a geographical area in the range of kilometres, comprising a shared transmission medium and a set
Link Layer. 5.6 Hubs and switches 5.7 PPP 5.8 Link Virtualization: ATM and MPLS
Link Layer 5.1 Introduction and services 5.2 Error detection and correction 5.3Multiple access protocols 5.4 Link-Layer Addressing 5.5 Ethernet 5.6 Hubs and switches 5.7 PPP 5.8 Link Virtualization: and
11/22/2013 1. komwut@siit
11/22/2013 1 Week3-4 Point-to-Point, LAN, WAN Review 11/22/2013 2 What will you learn? Representatives for Point-to-Point Network LAN Wired Ethernet Wireless Ethernet WAN ATM (Asynchronous Transfer Mode)
ADTRAN NetVanta 5660
ADTRAN NetVanta 5660 Lab Testing Detailed Report 08January2015 Miercom www.miercom.com Contents 1.0 Executive Summary... 3 2.0 Product Tested... 4 3.0 Test Bed How We Did It... 6 4.0 Performance Testing...
10 Gigabit Ethernet (10GbE) and 10Base-T - RoadMap
10 Gigabit Ethernet (10GbE) and 10Base-T - RoadMap Ethernet (10 Mbps) wasn't fast enough. Fast Ethernet (100 Mbps) wasn't fast enough. Even Gigabit Ethernet (1000 Mbps) wasn't fast enough. So IEEE recently
Data Link Protocols. TCP/IP Suite and OSI Reference Model
Data Link Protocols Relates to Lab. This module covers data link layer issues, such as local area networks (LANs) and point-to-point links, Ethernet, and the Point-to-Point Protocol (PPP). 1 TCP/IP Suite
Using High Availability Technologies Lesson 12
Using High Availability Technologies Lesson 12 Skills Matrix Technology Skill Objective Domain Objective # Using Virtualization Configure Windows Server Hyper-V and virtual machines 1.3 What Is High Availability?
WHITE PAPER. Packet Time Monitoring in Your Visibility Architecture
WHITE PAPER Packet Time Monitoring in Your Visibility Architecture www.ixiacom.com 915-6953-01 Rev. A, December 2014 2 Table of Contents Overview... 4 The Network Timing Domain... 5 Full Timestamp Trailer...
Data Center Automation - A Must For All Service Providers
WHITE PAPER Automation: The Future of Network Visibility www.ixiacom.com 915-6617-01 Rev. A, November 2013 2 Table of Contents Executive Summary... 4 The Need for Monitoring Switch Automation in the Data
WHITE PAPER. Application Performance Management and Lawful Interception
WHITE PAPER Application Performance Management and Lawful Interception www.ixiacom.com 915-6897-01 Rev. A, July 2014 2 Table of Contents A New Approach Unifies Two Disciplines to Drive Mutual Performance,
100 Gigabit Ethernet is Here!
100 Gigabit Ethernet is Here! Introduction Ethernet technology has come a long way since its humble beginning in 1973 at Xerox PARC. With each subsequent iteration, there has been a lag between time of
Protocol Architecture. ATM architecture
Asynchronous Transfer Mode (ATM) Asynchronous Transfer Mode: ATM 1990 s/00 standard for high-speed (155Mbps to 622 Mbps and higher) Broadband Integrated Service Digital Network architecture Goal: integrated,
Designing Reliable IP/MPLS Core Transport Networks
Designing Reliable IP/MPLS Core Transport Networks Matthias Ermel Workshop ITG FG 5.2.1 14. November 2008 München Content 1. Introduction 2. Protection Mechanisms 3. Failure Detection Page 1 Architecture
Objectives. Lecture 4. How do computers communicate? How do computers communicate? Local asynchronous communication. How do computers communicate?
Lecture 4 Continuation of transmission basics Chapter 3, pages 75-96 Dave Novak School of Business University of Vermont Objectives Line coding Modulation AM, FM, Phase Shift Multiplexing FDM, TDM, WDM
Cisco Nexus Planning and Design Service
Cisco Nexus Planning and Design Service Efficiently migrate to a 10GbE environment. Create a more scalable, efficient, and resilient data center architecture with Cisco Nexus Planning and Design Service.
Next-Generation IP Networking
Position Paper Next-Generation IP Networking Ethernet emerges as an ideal choice for global networking Ethernet is breaking new ground as a key technology for service providers and carriers in wide area
Oracle Big Data Appliance: Datacenter Network Integration
An Oracle White Paper May 2012 Oracle Big Data Appliance: Datacenter Network Integration Disclaimer The following is intended to outline our general product direction. It is intended for information purposes
Gigabit Ethernet. Abstract. 1. Introduction. 2. Benefits of Gigabit Ethernet
Table of Contents Abstract... 2 1. Introduction... 2 2. Benefits of Gigabit Ethernet... 2 2.1 Easy Migration to Higher Performance Levels... 3 2.2 Decreased Overall Costs Over Time... 3 2.3 Supports for
Introduction to MPIO, MCS, Trunking, and LACP
Introduction to MPIO, MCS, Trunking, and LACP Sam Lee Version 1.0 (JAN, 2010) - 1 - QSAN Technology, Inc. http://www.qsantechnology.com White Paper# QWP201002-P210C lntroduction Many users confuse the