ImproX 1 A Uninterrupted Power Supply

Similar documents
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Mobile Data Power Model: MDP-25

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

User Manual for CH-PFC76810

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

HM-W536 Install Guide

15 Series - Electronic step relay and dimmer. Features SERIE

BroadBand PowerShield. User Manual

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

DC POWER SUPPLY ALIMENTATION C.C.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

MCR1900 Media Converter 19-Slot Chassis

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

is then retained absolutely without interruption.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

FIREDEX Conventional Fire Panels

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Digital input modules

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

HotSwap MBP Maintenance Bypass

STRATO LED Drivers 70W, Single output

User s Manual Before using the inverter, you need to read and save the safety instructions.

How To Use A Power Supply Unit (Upu)

Thyristor-controlled power supplies and battery chargers

HP UPS R1500 Generation 3

ST Series POWER SUPPLIES USER INSTRUCTIONS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

INSTALLATION MANUAL. AC/DC Power Supply

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Battery Power Inverters

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Operating Manual UWAPS-TINY Series

Three-phase monitoring relay CM-PFE

AXIS 291 1U Video Server Rack Installation Guide

Waveguide Access Point WGA631. Product Guide

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Operating Instructions

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Manual. Solar Fountain Mobile Phone Charger

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

12 Volt 30 Amp Digital Solar Charge Controller

Power Supplies 3. SDN-P DIN Rail Series

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

RM4TG20 three-phase network control relay RM4-T - range V

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3500/62 Process Variable Monitor

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Voltage Regulator SPAU 341 C. Product Guide

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

MIC-WKT and MIC-WKT-IR

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Features. Picture. Specifications

Drayton Digistat +2RF/+3RF

Moxa EtherDevice Switch

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

StructureScan HD Module. Installation Guide ENGLISH

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Senses SV series industrial monitor user manual

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

Advantium 2 Plus Alarm

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

ADM1TE 5/30A DIN rail single phase two wire energy meter

MasterINTERFACE 39 Series - Relay interface modules

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

How To Use A Cdm250 Digital Multimeter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

instabus KNX / EIB System System E F G H

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

APD / Outputs 19" DC/DC Converter, 50 Watt

TMS TANK MANAGEMENT SYSTEM

Cross-beam scanning system to detect slim objects. 100 mm in

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Transcription:

ImproX 1 A UPS ImproX 1 A Uninterrupted Power Supply Overview Introduction The ImproX 1 Amp Uninterrupted Power Supply is specifically designed to provide a low noise, uninterrupted 13.7 V DC 1 A power supply to the ImproX range of Access Control Products. Additionally the UPS is capable of powering any item requiring smoothed, regulated DC power. The UPS is available in two models: XUP900-0-0-GB-00 with an input mains voltage of 110 V AC. XUP901-0-0-GB-00 with an input mains voltage of 230 V AC. The ImproX 1 Amp UPS provides one switched and two unswitched output voltages of 13.7 V DC at 1 A continuous. The two LED indicators located in the Power Output End Plate will show you Mains Fail, Fire Alarm and Battery Low conditions. The UPS outputs a Mains Fail Signal when you remove the input mains voltage. This signal switches the front panel Mains-on Indicator OFF when you remove the mains voltage. This signal is only available with the Battery connected. The UPS outputs a Battery Low Signal when the battery voltage falls below a set level. This signal switches the front panel Battery Low Indicator ON when the battery voltage falls below this limit. The UPS provides a dry contact Fire Alarm (uncommitted or free contact) interface input. When this input is short circuit, the UPS will cut the switched output and light the Battery Low Indicator. As this product is not waterproof, we ask that you install and use the UPS indoors. 1

Key Features Models for 110 V AC and 230 V AC mains input operation. Nominal output voltage of 13.7 V DC at 1 A continuous, with a fully charged Battery. Switched output for non-essential load on Battery Low detection. LED indicators for Mains Fail, Fire Alarm and Battery Low conditions. Signal outputs on detection of Mains Failure, Fire Alarm and Battery Low conditions. Automatic switch-over to Battery operation on Mains Failure. Compact, robust aluminium Cabinet, accommodating the power supply and a 12 V 6.5 Ah sealed lead acid gel Battery. Fire Alarm input. Approvals CE Approved. FCC Approval Pending. 2

Specifications Physical Environmental Dimensions Length : 171 mm (6.73 in). Width : 197 mm (7.75 in). Height : 88 mm (3.5 in). Approximate Weight : 1.7 Kg (3.70 lb) (Excluding the Battery). Cabinet Material : Aluminium. Colour : Black. Temperature Operating : -25 o C to +60 o C (-13 o F to +140 o F). Storage : -40 o C to +80 o C (-40 o F to +176 o F). Humidity Range : 0 to 95% relative humidity at +40 o C (+104 o F) noncondensing. Approvals (Test Information) EMC : EN 55022: Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment. EN 55024: Immunity Characteristics, Limits and Methods of Measurement. Electrostatic Discharge : IEC 61000-4-2: Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 2: Electrostatic Discharge Immunity Test. Basic EMC Publication. Radiated Susceptibility : IEC 61000-4-3: Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 3: Radiated, Radio-Frequency, Electromagnetic Field Immunity Test. Electrical Fast Transients : IEC 61000-4-4: Electromagnetic Compatibility (EMC). Part 4: Testing and Measurement Techniques. Section 4: Electrical Fast Transients / Bursts. Basic EMC Publication. Surge Immunity : IEC 61000-4-5: Surge Immunity. Conducted Susceptibility : IEC 61000-4-6: Conducted Susceptibility. Voltage Dips and Interruptions : IEC 61000-4-11: Voltage dips and short interruptions. Dust and Splash Resistance : Designed to work in an indoor (dry) environment similar to IP40. The Power Supply is, therefore, not sealed against water. Drop Endurance : 1 m (3.28 ft) drop (in packaging). 3

Electrical Input Input Voltage : 110 V AC or 230 V AC ± 5%. 50/60 Hz. Mains Input Fuse : 0.5 A 250 V (fuse mounted under the Mains Protection Cover of the UPS). Mains Input Power Cord : 15 A, 3-core power cable. Unswitched Outputs Output Voltage : Maximum 13.7 V DC +2%/-5% (with the Battery fully charged). Output Current : 1 A continuous (with the Battery fully charged). (See Figure 1 and Figure 2). Output Fuse : 2 A 250 V slow-blow, 20 mm x 5 mm glass (mounted below the Terminal Blocks). Ripple Voltage : <1 Vpp at 50 Hz. Switched Outputs Battery Output Voltage : Maximum 13.7 V DC +2%/-5% (with the Battery fully charged). Output Current : 1 A continuous (with the Battery fully charged). (See Figure 1 and Figure 2). Output Fuse : 2 A 250 V slow-blow (mounted below the Terminal Blocks). Ripple Voltage : <1 Vpp at 50 Hz. NOTE: The total continuous output current on the Switched, Unswitched and Battery Charging Outputs must not exceed 1.5 A. NOTE: In conditions where the mains voltage is reduced through area load, the output current capability of the UPS will be reduced. Refer to Figure 1 and Figure 2 for optimum operating conditions. Type : The Cabinet accepts a 12 V 6.5 Ah Lead Acid Battery. Size Length : 150 mm (5.09 in). Width : 63 mm (2.48 in). Height : 98 mm (3.85 in) (Including the terminals). 4

Optimum Operating Conditions Figure 1: 110 V AC Operation Figure 2: 230 V AC Operation Operator or Installer Interfaces LED Indicators Mains On : Green Illumination. Battery Low or Fire Alarm : Red Illumination. Installation Information Accessories You will find the following when unpacking your ImproX 1 A UPS: An ImproX 1 Amp UPS housed in a Black powder-coated Aluminium extruded Cabinet. The Cabinet will consist of a Top Cover and a Base sealed at each end with a Mild Steel End Plate, secured with 5 Thread Cutter Screws (M3 x 8 mm). An extra Serial Number Label. 5

Installing the Battery into the Cabinet CAUTION: Remember to install the Battery before attempting to install the UPS. 1. Remove the Top Cover of the Cabinet by unscrewing the top three screws on both End Plates. 2. Remove the Power Output End Plate (the end plate with the LED Indicators) by unscrewing the bottom two screws. 3. Slide the Battery halfway into the Cabinet on its side with the Battery Terminals on the opposite side to the Power Supply Circuit (PCB) see Figure 3. 4. Connect the Red Battery Lead to the Positive Battery Terminal and the Black Battery Lead to the Negative Battery Terminal. 5. Slide the Battery fully into the Cabinet and re-attach the Power Output End Plate. 6. Re-attach the Top Cover. Figure 3: Layout Diagram - Top View 6

Mounting the Cabinet Select the mounting position of the UPS considering routing of the power wires, visibility of the LED Indicators and ventilation. Secure the Base to the mounting surface using four suitable screws, nuts and bolts or rivets. Electrical Connections Connecting the UPS CAUTION: The UPS s Battery charges at 0.5 Amp. Therefore, if the Battery is used, the maximum load connected to the UPS MUST NOT EXCEED 1.5 Amp. 1. Use the labelled Terminal Blocks for the low voltage connections to the UPS, see Figure 4. 2. Neatly lead the wires out of the Cabinet using the glands or grommets in the Power Output End Plate. 3. Re-attach the Top Cover. NOTE: The extruded Cabinet is specifically designed so that the Top Cover will only fit one-way around. With the Mains Connector positioned towards you, the taller side of the Top Cover should be on the left-hand side. CAUTION: DO NOT exceed the Input Voltage specified. 4. Insert a standard kettle cord into the IEC Connector on the UPS for the high voltage connection. 5. Neaten the wiring connected to the UPS as needed. 6. Switch on the mains supply and resume normal operation. NOTE: If the UPS is in Battery Shutdown Mode, mains power is needed to carry on with normal operation. There may be a short delay before the Switched Output resumes operation after the mains supply is restored. 7

Figure 4: Typical 1 Amp UPS Low Voltage Electrical Connections 8

Fuse Information CAUTION: When replacing the fuse, disconnect the mains power supply to the UPS, and remove the Positive Lead from the Battery. The UPS inputs and outputs are protected by four fuses. If the UPS is overloaded and the fuses blow, replace the blown fuse with one of the same rating. Table 1 has details of the fuse ratings: Fuse Purpose Pos Rating Mains Input Fuse This fuse protects the high voltage Mains Input side of the system. F4 0.5 A 250 V Battery Fuse This fuse protects the Battery from overload as well as incorrect polarity connection. F3 2 A 250 V slow-blow Unswitched Output Fuse This fuse protects the Unswitched Output from overload. F2 2 A 250 V slow-blow Switched Output Fuse This fuse protects the Switched Output from overload. F1 2 A 250 V slow-blow Table 1: Fuse Ratings Serial Number Label The loose Serial Number Label (packaged with the UPS) identifies the type of UPS and its Serial Number. Guarantee or Warranty This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. 9

Ordering Information Order the ImproX 1 A Uninterrupted Power Supply using the following Impro part numbers: XUP900-0-0-GB-XX: ImproX 1 A UPS with an input mains voltage of 110 V AC. : ImproX 1 A UPS with an input mains voltage of 230 V AC. This manual applies to the ImproX 1 A Uninterrupted Power Supply XUP900-0-0-GB-01 and XUP901-0-0-GB-01. (The last two digits of the Impro stock code point to the issue status of the product). ImproX 1 A UPS\Product Specification Catalogue\ XUP350-0-0-GB-02 Issue 03 July 2005 LATEST ISSUE\X1A UPS-psc-en-03.doc 10