OPERATION & MAINTENANCE INSTRUCTION MANUAL

Similar documents
Float and Thermostatic Traps Series H, C and X

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

PBX Series Quick Fit Connector Bimetallic Steam Traps

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Air Eliminators and Combination Air Eliminators Strainers

Eastman plasticizers. Bulk storage guidelines. Storage equipment. Tank components and materials. Piping. Pumps. Valves. Gaskets

Instruction Manual. Please read the manual carefully before installing and using this product. This product is for off road use only.

Green Thread Product Data

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

SunMaxx Solar Filling Station Operating Instructions

Frequently Asked Questions Generators

BOWIE PUMPS OPERATION - MAINTENANCE

Operation & Maintenance Manual

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Installation and maintenance instructions

NITROUS TRANSFER PUMP INSTRUCTIONS

FIBERGLASS UNDERGROUND STORAGE TANKS Special Installation Instructions for New York City Gasoline and Diesel Motor Fuels

SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION

PC1131 Electric Air Compressor

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Boiler & Pressure Vessel Inspection discrepancies and failures

Application Data Important Safety Information

Routine and Emergency Boiler Operation

Rexroth Hydraulic Pump A10VO Series User Manual

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

81000 Series Aluminum Gate Valve Installation and Repair Manual

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

CARING FOR YOUR WATER HEATER

2010 Residential Water Heater Replacement Check List

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

rainbowsystem.com Rexair LLC Troy, Michigan 2011 Rexair LLC R14388A-0 Printed in U.S.A.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Finding and Fixing Leaks

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Cooling system components, removing and installing

Notes. Material 1. Appropriate Flammable Liquids

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

James M. Pleasants Company

San josé OWNER S MANUAL

PC1130 Electric Air Compressor

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

DRYER VENTING SPECIFICATIONS DRYER SAFETY

BLADDER SURGE CONTROL SYSTEM

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

ENGINE COOLING SYSTEM

Air Conditioner Water Heater Model ACWH18

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

Chemical Feed System Operation and Design Considerations

University of Tennessee Safety Guidelines

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

123 Industrial Loop Road Paynesville, MN Phone:

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

IMPORTANT SAFETY NOTICE

PREVENTATIVE MAINTENANCE

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

MILKING SYSTEM CLEANING AND SANITIZING: TROUBLESHOOTING MILK BACTERIA COUNTS. Alan Monken and Winston Ingalls West Agro, Inc. Kansas City, Missouri

SunMor SM-V30 Solar Water Heater Installation Manual

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Container Management for Hazardous Waste Generators Technical Guidance Document HW-2005-G1

Rental Services Temporary Cooling - Flexible Water Hose

123 Industrial Loop Road Paynesville, MN Phone:

VACUUM REFRIGERATION SYSTEMS

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

orlando OWNER S MANUAL

NFPA31FuelOilPiping 1 Revised

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Heating Water by Direct Steam Injection

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Steam Jet Vacuum Pumps

A Guide to Trouble-Free Cooling Towers

OWNER S MANUAL FOR THE PATIO SAUNA

Nitrogen Blanketing for Methanol Storage and Transportation

Model 43AP Pneumatic Controller, Style B

Operators manual Basic water heater

FILLING AND PURGING THE SYSTEM

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

Select Radiators Installation Guide

Steam Sterilization Cycles for Lab Applications

ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion

Chapter 7 Hydraulic System Troubleshooting

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Transcription:

Last Updated 01-12-2015 OPERATION & MAINTENANCE INSTRUCTION MANUAL

TABLE OF CONTENTS GENERAL Page 2 TANKS FOR FOOD APPLICATION Page 2 AFTER THE TANK IS PUT INTO SERVICE Page 3 TANK USAGE Page 3 AIR LOADING Page 4 TOP MANHOLE BOLTING (20 & 24 ) Page 5 TOP MANHOLE BOLTING (30 & 36 ) Page 6 SIDE MANHOLE BOLTING (20 & 24 ) Page 7 SIDE MANHOLE BOLTING (30 & 36 ) Page 8 FLANGE BOLTING (1 14 ) Page 9 FLANGE BOLTING (16 24 ) Page 10 FLANGE LOADS Page 11 Page 1

GENERAL Because of FIBERGLASS REINFORCED PLASTIC tanks unique, physical and structural characteristics; they are flexible, lightweight, corrosion resistant, and stronger than tanks made of other plastic materials. Care, however, should be taken to follow the Handling and Installation instructions. If your fiberglass tank has been installed with insulation and a Heat Maintenance Unit, the wiring instructions are placed inside the control box. If you have a BTT Dual-Tek double wall tank and your tank was supplied with BTT s Leak Detection System and/or Desiccant Filter, please refer to the instructions supplied with those items. Once the tank has been properly installed and placed in service, BTT recommends regular routine inspections as a part of your preventative maintenance program. The care and operation of FRP vessels rely mostly on common sense. To maximize trouble free service, Belding Tank recommends the following: 1. Inspect your vessel thoroughly upon receipt. 2. Follow the Handling and Installation instruction. 3. Wash your vessel thoroughly w/detergent and rinse before putting in service (see FDA Requirements) TANKS FOR FOOD APPLICATION BELDING TANK TECHNOLOGIES tanks will comply with U.S. Food, Drug and Cosmetic Act, as amended, and applicable FDA regulations (21 cfr 177.2420). These tanks may be used as components intended for repeated use in contact with food, subject to certain limitations described in that regulation. BELDING TANK TECHNOLOGIES tanks are chemically acceptable in processing or storage areas for contact with meat or poultry food products prepared under federal inspection and used at temperatures below 180 F. This acceptance has been given by the United States Department of Agriculture. Prior to shipping your tank, B.T.T. applies a (4) hour heat cure followed by a water rinse to the tank interior. Page 2

TANKS FOR FOOD APPLICATION (Cont d.) After installation and before your tank is put into service, attention to the following procedures is important to achieve FDA compliance: 1. After tank installation, steam-treat or steep tank with hot water for 8-16 hours at 160 180 F. This should remove all residual styrene from the laminate surface. 2. Wash the tank thoroughly with detergent and rinse it thoroughly. 3. Check state and local regulations for required compliance in addition to the above recommendations. AFTER THE TANK IS PUT IN SERVICE: 1. Keep the vessel clean. a. It will remain more aesthetically pleasing. b. If the tank is ever damaged, it will be evident. 2. Make a visual tank inspection inside and outside the tank every 6-12 months. 3. If your tank has been supplied with a screen on your Vent, care should be taken to inspect the screen regularly and kept clean and unobstructed. CAUTION: Condensate on the screen during cold weather may freeze which may result in damage to the tank. 4. Rapid temperature changes to the fiberglass tank MUST BE AVOIDED, especially going from a hot tank to a cold tank. TANK USAGE This tank has been sold for a specific chemical storage application. Before changing the chemical environment, consult with BELDING TANK TECHNOLOGIES (your warranty may be void without written authorization from B.T.T.) 1. Do not allow the stored material to freeze. 2. BELDING TANK standard tanks are NOT designed for pressure or vacuum other than liquid head. Do not restrict the tank vent. Vapor removal equipment (if installed) must not cause any pressure or vacuum conditions. 3. The rated capacity of the tank is to the top of the straight side only. If any of the above guidelines are not followed or if any modifications are made without written approval from BELDING TANK TECHNOLOGIES, it could result in structural damage to the tank and would void the existing warranty. Page 3

AIR LOADING Tanks are often filled with liquids from tanker trucks by pressurizing the headspace above the liquid within the tanker with compressed air to force tanker contents into the receiving tank. This is most typically done when the liquid being transferred is a corrosive chemical, which could damage a pump. Although such a procedure eliminates the need for a pump, a possibility does exist that the pressurized air within the tanker will follow the liquid into the receiving tank, and destroy the tank, due to excessive pressure. Generally speaking, the tanker is connected to the receiving tank by a hose. The compressed air pushing down on the liquid forces the liquid through the hose and into the receiving tank. The frictional resistance offered by the hose and the fitting limits the maximum velocity of the liquid moving through the hose to a reasonable value. The air displaced by the liquid entering the tank escapes through the normal vent provided on the tank. However, when the last of the liquid passes through the hose, the compressed air within the tanker rushes through the hose at an extremely high velocity, because this air does not meet significant frictional resistance in the hose, as the liquid does. This air enters the headspace in the receiving tank and expands with almost explosive speed and force. The conventional tank vent cannot relieve this excessive pressure within the tank. When the pressure within the receiving tank exceeds that for which the tank is designed, either the tank head blows off or some other portion of the tank ruptures. Preferably, the person operating the tanker will interrupt the liquid flow before the last of the liquid leaves the tanker, preventing the compressed air from entering the tank. However, through inattention or carelessness, the operator will occasionally forget to interrupt the liquid at the "appropriate time" RESULT POSSIBLE TANK FAILURE. The quoted description above is the possible occurrence when the tank is air loaded IMPROPERLY; proper procedure requires that the operator interrupt the liquid at the appropriate time. PROPER PROCEDURE WILL NOT CAUSE TANK FAILURE. To guard against tank failure when the tank is air loaded, opening the manhole cover is suggested. This precaution, if the tank is air loaded improperly, does NOT eliminate the possibility of tank failure but it may lessen the possibility. TO ELIMINATE TANK FAILURE DUE TO IMPROPER AIR LOADING: A. BUILD A PRESSURE VESSEL, OR B. ELIMINATE THE POSSIBILITY OF THE AIR PAD PRESSURE IN THE TANKER FROM REACHING THE TANK INTERIOR BY: 1. Suspending the fill line above the manway (i.e. line is not to enter tank), OR 2. Monitoring a flow meter to determine when the tanker will be empty, OR 3. Install a "No-Flow" switch in tandem with a control valve. Note: B.T.T. recommends consulting with a reputable firm in reference to flow meters and no flow switches. If you have any questions or special circumstances that require discussion, please feel free to contact us at 1-800-253-4252. Page 4

TOP MANHOLE BOLTING SEQUENCE 20 Top Manhole 24 Top Manhole Drawings not to scale BELDING TANK TECHNOLOGIES standard ATMOSPHERIC pressure top manhole includes half the number of bolts as shown in the illustrations above. The bolts should be hand tightened plus a 1/8 turn. The bolt sequence above does NOT have to be followed. When the tank is designed for pressure up to 12 water column (0.432 psig), then ALL bolts illustrated above will be included and the bolt torque setting is 3 ft. lbs. For pressures above 12 water column (0.432 psig), please refer to the side manhole charts for rated pressure. Page 5

TOP MANHOLE BOLTING SEQUENCE 30 Top Manhole 36 Top Manhole Drawings not to scale BELDING TANK TECHNOLOGIES standard ATMOSPHERIC pressure top manhole includes half the number of bolts as shown in the illustrations above. The bolts should be hand tightened plus a 1/8 turn. The bolt sequence above does NOT have to be followed. When the tank is designed for pressure up to 12 water column (0.432 psig), then ALL bolts illustrated above will be included and the bolt torque setting is 3 ft. lbs. For pressures above 12 water column (0.432 psig), please refer to the side manhole bolt sequence and torque charts for rated pressure. Page 6

SIDE MANHOLE BOLTING SEQUENCE 20 Side Manhole 24 Side Manhole Drawings not to scale Side Manhole Maximum Bolt Torque Manhole PSI Rating (See Drawing) Diameter 5 10 15 20 25 30 35 40 20 16 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 24 16 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. 20 ft. lbs. Page 7

SIDE MANHOLE BOLTING SEQUENCE 30 Side Manhole 36 Side Manhole Drawings not to scale Side Manhole Maximum Bolt Torque Manhole PSI Rating (See Drawing) Diameter 5 10 15 20 25 30 35 40 30 25 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 36 25 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. 43 ft. lbs. Page 8

FLANGED NOZZLE BOLTING SEQUENCE CAUTION: A flange spacer MUST BE USED when bolting FRP flanges to raised face flanges. Use only full face gaskets. Do NOT over torque flange bolts. 4 Bolt 8 Bolt 12 Bolt Drawings not to scale Flanged Nozzle PSI Rating & Maximum Torque Diameter PSI Rating Maximum Torque 1 125 14 ft. lbs. 1-1/2 125 20 ft. lbs. 2 125 41 ft. lbs. 2-1/2 125 43 ft. lbs. 3 125 43 ft. lbs. 4 125 43 ft. lbs. 6 100 77 ft. lbs. 8 50 77 ft. lbs. 10 50 98 ft. lbs. 12 50 125 ft. lbs. 14 25 105 ft. lbs. Page 9

FLANGED NOZZLE BOLTING SEQUENCE CAUTION: A flange spacer MUST BE USED when bolting FRP flanges to raised face flanges. Use only full face gaskets. Do NOT over torque flange bolts. 16 Bolt 20 Bolt Drawings not to scale Flanged Nozzle PSI Rating & Maximum Torque Diameter PSI Rating Maximum Torque 16 25 102 ft. lbs. 18 25 135 ft. lbs. 20 25 131 ft. lbs. 24 25 205 ft. lbs. Page 10

Flanged Nozzle Allowable Loads Without Gussets Size A B C 1 100 LBS. 50 FT./LBS. 100 LBS. 1-1/2 100 LBS. 100 FT./LBS. 100 LBS. 2 100 LBS. 100 FT./LBS. 100 LBS. 3 100 LBS. 100 FT./LBS. 100 LBS. 4 100 LBS. 100 FT./LBS. 100 LBS. 6 100 LBS. 100 FT./LBS. 100 LBS. 8 100 LBS. 100 FT./LBS. 100 LBS. 10 100 LBS. 100 FT./LBS. 100 LBS. 12 100 LBS. 100 FT./LBS. 100 LBS. Page 11