VESSELS DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications

Similar documents
solarplus solar systems general features

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Electric Flow Boiler

In-Line Air Separators

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

ECOCIAT. Domestic hot water heat recovery unit

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Flamco. Flexcon M. Installation and operating instructions Flamco

Technical data. Danfoss DHP-A

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Stove-boiler for solid fuels KW Directions for use and assembling

Solar Hot Water Heaters

Automatic Bypass Control AVDO

HERZ-Thermal Actuators

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

1 DESCRIPTION OF THE APPLIANCE

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Data sheet ECC 12 and 22

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

RPV - RP - RA air handling units

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Select Radiators Installation Guide

Flamco Diaphragm pressure expansion vessels

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

LG Electronics AE Company, Commercial Air Conditioning

Session 2: Hot Water Supply

Thermostatic valve Type AVTA

Technical catalogue convectors POLAND 2012

Blowdown vessels Meeting the requirements of HSE PM60

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

HS-901(A) BASIC STEAM HEATING SYSTEMS

Itho Products for Hot and Boiling water. product-

Transformer oil cooler ALFA A02

Zenith Solar thermal 4.5m pump station Installation manual

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

HEAVY DUTY STORAGE GAS

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Flexcon ASME Tanks. Flexcon Industries Ph: Pond Street Fax:

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Operators manual Basic water heater

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Digital inductive conductivity transmitter

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Natural geothermal energy.

HL Series - Commercial Heaters Tankless Water Heating Solutions

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

SF15K SF05KSS, SF10KSS

SOLAR HEATING SYSTEMS.

ASME Packaged Indirect Fired Water Heater

FILLING AND PURGING THE SYSTEM

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Draining and filling cooling system

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Laddomat Charging unit

Float and Thermostatic Traps Series H, C and X

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Conlift1, Conlift2, Conlift2 ph+

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Hot Water. Heat pump water heaters. Residential and Commercial R410a

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

FLASH TANK ECONOMIZER PRODUCT GUIDE

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Power consumption (kw)

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Drain Back systems Made in Germany

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

AdSORPTION CHILLER NAK

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Daikin Altherma hybrid heat pump. The natural combination

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Heating Controller. Building Technologies HVAC Products

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

HEAT INTERFACE UNITS (Modular)

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

ENERGY RETROFIT PROGRAM

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Transcription:

OPERATING LIMITS Static head up to: 40 m CE Temperature range: 10 to +110 C Operating pressure: 4 and 10 bar Test pressure: 25 bar* * according to models, see table. VESSELS DIAPRAGM OR BLADDER TANKS For expansion and pressure boosting applications diaphragm Principle of the diaphragm vessel. APPLICATIONS EXPANSION For maintaining the pressurization of systems subject to temperature variations by compensation of expansions. For central heating, cooling and airconditioning systems. PRESSURE BOOSTING Direct pressure boosting: A small vessel maintains the pressure in the installation when no delivery is required and protects the pressure controller against pressure variations and expansion. Conventional pressure boosting: A large vessel with a large useful reserve covers the low deliveries required by the installation. bladder Principle of the bladder vessel. STAINLESS STEEL secondary version, used when quality is imperative 1 D.S. No. 00-2/ENG. - Ed. /05-0-02

VESSELS BENEFITS Closed vessels removing any risk of evaporation and frost. Diaphragm in natural rubber, food processing grade, easily interchangeable. Eliminates the need for expensive air replacement systems. Speedy, easy installation. No maintenance. Large useful reserve avoiding starting the pump too often in pressure boosting configuration. Vessels approved by the W.R.C. (Water Research Center) and conform to standard DIN 4807. DESIGN orizontal or vertical closed vessel. EPDM or Butyl bladder. Butyl bladder, moulded in a single piece and secured inside the tank in one or two points according to capacities. The bladder or diaphragm ensures total separation between and air. It is protected by a strainer at the inlet. The vessel enveloppe is coated (inside and outside) with an anti-corrosion paint. Inflating valve, standard car type, protected by a cap. Vessels with 2 to 24 litres' capacity are mounted directly on the piping; other models are to be placed on the ground. Vessels are factory tested or submitted to Mines Administration testing. TEORETICAL INSTALLATION VOLUME Conversion of kw into litres: heating for for body 1 kw installations Convectors and steel radiators 7 litres Cast iron radiators 10 litres 581 th/hr ot plates 8,5 litres Any heating body 7 litres > 581 th/hr 1 th/hr = 0 kcal = 1.16 kw. EXPANSION: OPERATING PRINCIPLE 1 2 diaphragm Before the increase in temperature, the pressure inside the vessel balances the installation static pressure. The fills the whole vessel volume. The diaphragm remains stuck against the wall. BASIS FOR COMPUTATION inflating valve During the increase in temperature, the volume in the system increases under the effect of expansion and compresses the diaphragm. The volume decreases and the pressure in the installation increases. After the increase in temperature, the final pressure nears the calibration pressure of the safety valve. When the boiler is shut down, the in the system cools down and the installation pressure decreases. The contained in the vessel returns to the system to restore the pressure and the volume. In cooling and air-conditioning installations: when the system cools down, the volume decreases; the expansion vessel returns the to the system to maintain the pressure. upon shutdown, the at ambient temperature expands, the increased volume of enters the vessel and compresses the diaphragm. OT WATER SYSTEM 1 - Expansion volume: V exp = Vt x (Cm Cr) where: Vt : total installation volume Cm : Expansion coefficient at average operating temperature, i.e.: T boiler outlet + T return 2 Cr : Expansion coefficient at filling temperature (10 to 12 C) 2 - Total vessel volume: Vt x (Cm Cr) V = 1 P1 P2 where: P1 : effective inflating pression corresponding to the static head + 1 bar* P2 : valve cracking pressure + 1 bar* * Corresponding to the atmospheric pressure. WATER EXPANSION COEFFICIENTS temperature coefficient temperature coefficient C C 10 0.0004 075 0.0256 20 0.0018 080 0.0288 0 0.0044 085 0.022 40 0.0079 090 0.057 50 0.0119 095 0.094 55 0.014 0.041 60 0.0169 105 0.0472 65 0.0196 110 0.051 70 0.0225 Note: volumes of still cold submitted to expansion require a food-processing grade expansion system. 2

250 VESSELS APPLICATION: EXPANSION 1.000.000 800.000 600.000 400.000 200.000 TOTAL VOLUME OF TE INSTALLATION IN LITRES.000 80.000 60.000 40.000 20.000 10.000 8.000 6.000 4.000 2.000 1.000 800 600 400 200 AVERAGE TEMPERATURE IN C 20 0 40 50 60 70 80 90 110 80 60 40 bar 5m 6 8 12 18 24 5 50 80 00 500 750 1500 0 10 15 8 12 18 24 5 50 80 12 18 24 5 50 80 250 250 00 500 750 1500 00 500 1500 750 0 0 4/7 bar 4 4.5 20 25 12 18 24 5 50 80 250 00 500 750 1500 24 50 00 500 750 0 1500 0 Operating pressure 5 5.5 0 5 24 50 00 500 750 0 1500 24 50 00 500 750 0 1500 10/15 bar 6 bar 40m 24 50 00 500 750 0 1500 Static heads in m Valve cracking pressures in bar (or valve calibration). NOTE: Above 500 litres, use multiples or add vessels. For expansion of secondary systems, hot or cold, use of food-processing grade vessels is mandatory. These vessels also ensure the safety of systems filled with and 0% glycol.

VESSELS APPLICATION: CONVENTIONAL PRESSURE BOOSTING PRESSURES IN BAR VESSEL VOLUME IN LITRES Pe Pd 8 18 24 50 60 200 00 500 750 0 1500 1.5 2.5 2.2 4.9 6.5 1.6 16. 27.1 54 81 16 204 271 407 54 1.5 2.9 6.4 8.6 17.8 21.4 5.6 71 1071 178 267 56 54 71 2 1.9 4. 5.7 11.9 14. 2.8 48 71 119 178 28 56 475 2.5 2.5 5.7 7.6 15.8 19.0 1.7 6 95 158 28 17 475 6 2.5.5 1.7.8 5.1 10.6 12.7 21.1 42 6 106 158 211 17 422 2.5 4 2. 5.1 6.8 14. 17.1 28.5 57 86 14 214 285 428 570 4 1.5.4 4.6 19.5 11.4 19.0 8 57 195 14 190 285 80 4.5 2.1 4.7 6.2 1.0 15.5 25.9 52 78 10 194 259 89 518 5 2.5 5.7 7.6 15.8 19.0 1.7 6 95 158 28 17 475 6.5 4.5 1.4.1 4.1 18.6 10.4 17. 5 52 186 10 17 259 45.5 5 1.9 4. 5.7 11.9 14. 2.8 48 71 119 178 28 56 475.5 5.5 2. 5. 7.0 14.6 17.5 29.2 58 88 146 219 292 48 585 4 5 1. 2.9.8 17.9 19.5 15.8 2 48 179 119 158 28 17 4 5.5 1.8.9 5. 11.0 1.2 21.9 44 66 110 164 219 29 428 4 6 2.2 4.9 6.5 1.6 16. 27.1 54 81 16 204 271 407 54 4.5 5.5 1.2 2.6.5 17. 18.8 14.6 29 44 17 110 146 219 292 5 7 1.9 4. 5.7 11.9 14. 2.8 48 71 119 178 28 56 475 BASIS FOR COMPUTATION Determine the vessel volume according to the cut-in pressure (Pe), triggering pressure (Pd) and useful reserve. Compute the useful reserve using the following general formula: RU = 16.5 x Q n where: Q : average delivery of a pump l/min. n : max. number of start-ups per hour (11 to 15). Example: Q = 9 m /hr, i.e. 150 l/min. n = 11 start-ups/hour max. Pe = 2 bar. Pd =.5 bar. Useful reserve (RU): RU = 16.5 x 150 = 225 litres 11 In the table opposite, look for the vessel volume corresponding to a useful reserve of 225 litres (or the nearest value), according to pressures Pe and Pd. Vessel volume: 750 litres Actual useful reserve: 28 litres 5 8 2.5 5.7 7.6 15.8 19.0 1.7 6 95 158 28 17 475 6 6 9 2. 5.1 6.8 14. 17.1 28.5 57 86 14 214 285 428 570 7 10 2.1 4.7 6.2 1.0 15.5 25.9 52 78 10 194 259 89 518 8 11 1.9 4. 5.7 11.9 14. 2.8 48 71 119 178 28 56 475 10 14 2.0 4.6 6.1 12.7 15.2 25. 51 76 127 190 25 80 507 12 16 1.8 4.0 5.4 11.2 1.4 22.4 45 67 112 168 224 5 447 Remark: Choose the biggest difference between Pe and Pd, which allows to reduce the vessel volume for a same useful reserve. Triggering pressure (Pd) Cut-in pressure (Pe) NOTE Vessel capacity is determined according to the pump delivery, cut-in and triggering pressures, and the number of start-ups per hour. 4

VESSELS PRESSURE BOOSTING DIMENSIONS FIG. 1 for connection onto piping FIG. 2 FIG. 24 l : 485 mm 50 : 620 60 : 710 : 795 A A h h All 12/18-bar and 10/15-bar vessels are tested and stamped by the Mines Administration. A 0.16 l GALVANIZED VESSELS The use of these vessels is subject to very strict hygiene rules, CONSULT US BEFORE USE. to l - 4/7 bar. Dimensions available upon request. CAPACITY ORDER FIG. WIT h A MASS PRESSURE (in bar) litres REFERENCE BLADDER mm mm mm kg operating test 2012 S.S. 06600 1 220 90 G 1.2 04 12 2020 S.S. 06601 1 270 420 G 1.5 04 12 2028 INOX 06604 1 220 10 G /4 2.5 04 12 2018 INOX 06605 1 260 70 G /4.5 04 12 2024 INOX 06606 1 260 485 G /4 5.5 04 12 2024 INOX 06609 2 260 285 14 G 1 5.5 04 12 2050 INOX 06610 2 80 410 189 G 1 11.5 04 12 2060 INOX 401942 2 80 410 189 G 1 14 04 12 2 INOX 06611 2 460 490 229 G 1 19.5 04 12 0250 INOX 06607 80 715 170 G 1 10.5 04 12 0 INOX 06608 460 880 200 G 1 20 04 12 0200 INOX 020845 60 10200 200 G 1 1 /2 7 04 07 000 INOX 020846 60 1750 200 G 1 1 /2 46 04 07 0500 INOX 020847 60 20250 200 G 1 1 /2 6 04 07 0050 INOX 01910 400 400 170 G 1 22 10 15 0 INOX 020848 60 760 200 G 1 1 /2 40 10 15 0200 INOX 020849 60 10950 200 G 1 1 /2 60 10 15 000 INOX 01876 60 1450 200 G 1 1 /2 85 10 15 0500 INOX 01877 60 20650 200 G 1 1 /2 10 10 15 0750 INOX 020850 850 19000 200 G 1 1 /2 210 10 15 0 INOX 020851 850 2 200 G 1 1 /2 245 10 15 1500 INOX 020852 00 24700 200 G 1 1 /2 50 10 15 INOX 02085 00 100 200 G 1 1 /2 460 10 15 ANTI-AMMER VESSELS* 0000,16 06602 1 085 110 G 1 /4 0. 15 25 VESSELS SPECIFIC TO PRESSURE BOOSTERS 0008 02098 1 200 08 G /4 2.5 08 12 0024 064615 1 250 560 G 1 7 12 18 Operating temperature 10 C to +110 C max. (60 C for anti-hammer vessels). * Also exist in 5-litre capacity. 5

VESSELS DIMENSIONS FEATURES FIG. 1 for connection onto piping EXPANSION FIG. 2 A FIG. a) Installation In expansion configuration, on boiler return line, before the circulating pump(s) if installed on the return line. In pressure boosting configuration, on piping connected to the discharge collector. A h A Charge pressure. (Check once a year.) Charge pressure shall be slightly below: the system pressure (after venting), in expansion configuration; the cut-in pressure less approx. 0.2 bar, in pressure boosting configuration. Max. charge limit. bar for 4/7- and 4/12-bar vessel, 5 bar for 10/15-bar vessel. Make sure the total pressure at vessel inlet is lower than the max. service pressure. Operating temperature 10 C to +110 C max. CAPACITY ORDER FIG. WIT DIA- WIT h A MASS PRESSURE (in bar) litres REFERENCE PRAGMBLADDER mm mm mm kg operating test 0006 066284 1 245 248 G /4 2 04 07 0008 066285 1 245 275 G /4 2.5 04 07 0012 066286 1 285 20 G /4 04 07 0018 066287 1 285 90 G /4 4 04 07 0024 066288 1 25 420 G /4 5 04 07 005 066289 1 80 465 G 1 7 04 07 0050 066290 2 80 650 G 1 10 04 07 0080 066291 2 460 700 G 1 12 04 07 0 066292 2 460 810 G 1 16.5 04 07 0150 40001550 2 510 970 G 1 24 04 07 0250 40001560 2 590 1200 G 1 40 04 07 0200 020845 60 10200 200 G 1 1 /2 7 04 07 000 020846 60 1750 200 G 1 1 /2 46 04 07 0500 020847 60 20250 200 G 1 1 /2 6 04 07 0050 01910 400 400 170 G 1 22 10 15 0 020848 60 760 200 G 1 1 /2 40 10 15 0200 020849 60 10950 200 G 1 1 /2 60 10 15 000 01876 60 1450 200 G 1 1 /2 85 10 15 0500 01877 60 20650 200 G 1 1 /2 10 10 15 0750 020850 850 19000 200 G 1 1 /2 210 10 15 0 020851 850 2 200 G 1 1 /2 245 10 15 1500 020852 00 24700 200 G 1 1 /2 50 10 15 02085 00 100 200 G 1 1 /2 460 10 15 IMPORTANT Safety valve compulsory on vessels tested by the Mines Administration. b) Packaging Vessels are pre-charged with (1 or 1.5 bar) and delivered in a cardboard packing or a plastic bag, depending on models. A plate stamped by the Mines Administration is affixed on 'Mines-tested' vessel front panel. c) Maintenance Standard bladder replacement. RECOMMENDED ACCESSORIES Safety valves with or without pressure gauge. Pressure gauge. Automatic air vent NOTE For higher installation characteristics, see data sheets specific to expansion modules: EXPANSON. The 5-litre vessel is supplied with a bracket for wall mounting (with 2 holes 11 - distance b/c 250 mm). 6 5, bd de la République - Espace Lumière - Bât. 6-7840 Chatou Cedex Tél.: 0820 87 624 - Fax: (0) 1 0 09 82 48 - http//www.salmson.fr