Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses

Similar documents
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Optimum proportions for the design of suspension bridge

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

A Study on Power Generation Analysis of Floating PV System Considering Environmental Impact

Code of Standard Practice for Timber Frame Structures

Structural Axial, Shear and Bending Moments

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

FLow pattern around cable and its aerodynamic characteristics in critical Reynolds number range

A NEW DESIGN METHOD FOR INDUSTRIAL PORTAL FRAMES IN FIRE

CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System

How To Calculate Tunnel Longitudinal Structure

How To Write An Analysis System For Bridge Test

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Southern AER Atmospheric Education Resource

Renewable Energy. Solar Power. Courseware Sample F0

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Building materials thermal conductivity measurement and correlation with heat flow meter, laser flash analysis and TCi

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR PRODUCTION ON THE PIERCED FLAT SHEET METAL USING LASER FORMING PROCESS

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

The University of Birmingham (Live System)

Perforated Shearwall Design Method 1

DEVELOPMENT OF WEB-BASED SUN-HOURS AND ENERGY ANALYSIS SYSTEM USING IFC

Tall Building Form Generation by Parametric Design Process

CH. 2 LOADS ON BUILDINGS

Earth-Sun Relationships. The Reasons for the Seasons

INSTALLATION. General. Important Note. Design. Transport

INTRODUCTION TO BEAMS

DETERMINATION OF TIME-TEMPERATURE SHIFT FACTOR FOR LONG-TERM LIFE PREDICTION OF POLYMER COMPOSITES

Which month has larger and smaller day time?

Analysis of Steel Moment Frames subjected to Vehicle Impact

Analysis of the Response Under Live Loads of Two New Cable Stayed Bridges Built in Mexico

Geography affects climate.

Tropical Horticulture: Lecture 2

HOUSE BUILDING DIGEST

Moisture Content in Insulated Basement Walls

DEVELOPMENT OF HYBRID VECTORIZING SOFTWARE FOR DIGITIZATION OF CADASTRAL MAPS

What Causes Climate? Use Target Reading Skills

Evaluation and Field Load Testing of Timber Railroad Bridge

Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width

CELESTIAL MOTIONS. In Charlottesville we see Polaris 38 0 above the Northern horizon. Earth. Starry Vault

to encourage high quality tropical vernacular Queensland architecture throughout the Shire;

Graphing Sea Ice Extent in the Arctic and Antarctic

Climate and Weather. This document explains where we obtain weather and climate data and how we incorporate it into metrics:

Study on growth and sprouts of Oak Forest for Forest fire site in South Korea.

Building a simple seismometer

DAMPED VIBRATION ANALYSIS OF COMPOSITE SIMPLY SUPPORTED BEAM

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

COST ESTIMATION METHODOLOGY USING DATABASE LAYER IN CONSTRUCTION PROJECTS

Detection and Restoration of Vertical Non-linear Scratches in Digitized Film Sequences

1. In the diagram below, the direct rays of the Sun are striking the Earth's surface at 23 º N. What is the date shown in the diagram?

Design of Impact Load Testing Machine for COT

Ultrasonic Detection Algorithm Research on the Damage Depth of Concrete after Fire Jiangtao Yu 1,a, Yuan Liu 1,b, Zhoudao Lu 1,c, Peng Zhao 2,d

Fric-3. force F k and the equation (4.2) may be used. The sense of F k is opposite

PROJECT MANAGEMENT INFORMATION SYSTEMS FOR CONSTRUCTION MANAGERS (CM): CURRENT CONSTITUENTS AND FUTURE EXTENSIONS

Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth

AN EXPLANATION OF JOINT DIAGRAMS

Development of Method for LST (Land Surface Temperature) Detection Using Big Data of Landsat TM Images and AWS

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

An Analysis of the Rossby Wave Theory

Software Development for Cooling Load Estimation by CLTD Method

Prelab Exercises: Hooke's Law and the Behavior of Springs

Information Contents of High Resolution Satellite Images

The Combination Forecasting Model of Auto Sales Based on Seasonal Index and RBF Neural Network

A study on major design elements of tracking-type floating photovoltaic systems

Modeling Beams on Elastic Foundations Using Plate Elements in Finite Element Method

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Global Seasonal Phase Lag between Solar Heating and Surface Temperature

Formwork for Concrete

Beginning on Friday, Jan 22, and on subsequent investigations, the following issues were identified:

STATUS REPORT FOR THE SUBMERGED REEF BALL TM ARTIFICIAL REEF SUBMERGED BREAKWATER BEACH STABILIZATION PROJECT FOR THE GRAND CAYMAN MARRIOTT HOTEL

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

An Analysis of the Factors Affecting Warehouse Rents

2.1. Architectural Character. Mountain. Agrarian. Craftsman. Gold Rush

The Bending Strength of Pasta

A Fuzzy System Approach of Feed Rate Determination for CNC Milling

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Strip Flatness Prediction in a 4 High Tandem Mill Using a Dynamic Model.

Hybrid simulation evaluation of the suspended zipper braced frame

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Structural Failures Cost Lives and Time

South Africa. General Climate. UNDP Climate Change Country Profiles. A. Karmalkar 1, C. McSweeney 1, M. New 1,2 and G. Lizcano 1

Optimum Solar Orientation: Miami, Florida

Comparison of Different Methods for Determining Methane Emission from Waste Disposal Sites in Thailand

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

In this study analytical investigation of effect of retrofit application using carbon fiber (CFRP) on seismic behavior of a monumental building at

DYNAMIC ANALYSIS ON STEEL FIBRE

A DISCUSSION ON THE DESIGN PRINCIPLES OF A PATENTED PORTABLE DIRECT SUNLIGHT LIGHT-DUTY UNIVERSAL HELIODON MOUNTED ON A CAMERA TRIPOD

Copyright 2011 Casa Software Ltd. Centre of Mass

FXA UNIT G484 Module Simple Harmonic Oscillations 11. frequency of the applied = natural frequency of the

Earth, Sun and Moon is a set of interactives designed to support the teaching of the QCA primary science scheme of work 5e - 'Earth, Sun and Moon'.

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

STRUCTURAL GUIDE THE PERFECT PARTNER FOR THE TRADE

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Introduction to Structural Drafting

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

How To Calculate Global Radiation At Jos

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Stress and deformation of offshore piles under structural and wave loading

Transcription:

Civil Engineering and Architecture 3(5): 107-120, 2015 DOI: 10.13189/cea.2015.030503 http://www.hrpub.org Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses Yeong-Min Kim College of Architecture, Myongji University, South Korea Copyright 2015 by authors, all rights reserved. Authors agree that this article remains permanently open access under the terms of the Creative Commons Attribution License 4.0 International License Abstract In this research, surface moisture contents of columns and roof deflection of three Korean traditional timber houses were monitored. The monitored houses are composed of two different types of Hanok, that is, a one-story traditional Hanok built by traditional construction method, and two two-storied new-styled Hanok built by modernized construction method. The monitoring of traditional Hanok and new-styled Hanok1 has been carried out for about two and a half years, and that of the new-styled Hanok2 is 14 months. The monitored moisture contents were analyzed according to column location to the sun, wood types and relative humidity. The moisture contents of the northern columns are 0.71% higher than those of the southern columns, and moisture contents of raw wood was 0.83% higher than that of the glued structural wood. The mean vertical deflection of angle rafters is 11.6mm in traditional Hanok, 4.2mm in new-styled Hanok1 and 2.1mm in new-styled Hanok2. Meanwhile, the mean vertical deflection of plane rafters is 21.5mm in traditional Hanok, 9.7mm in new-styled Hanok1 and 20.3mm in new-styled Hanok2. Angle rafters and plane rafters showed meaningful deformations and that were affected mainly by roof weight and supporting member. Keywords Korean Traditional Timber Houses, Monitoring, Moisture Contents, Roof Deflection new-styled Hanok generally uses glued structural wood. (a) Traditional Hanok 1. Introduction The Korean traditional timber house is called Hanok. The main structure of Hanok is a post and lintel timber frame. The connection types of the traditional Hanok are mainly mortise and tenon joints of only wood, and roof weight of the traditional Hanok is about 5~10kN/m 2, which is somewhat heavy in timber structure. On the other hand, new-styled Hanok, which is a modernized Hanok, to fit for the contemporary life styles has been developed recently. The new-styled Hanok has steel plate and bolt joints and light roof weight of about 2~3kN/m 2. The structural members used in traditional Hanok are generally raw wood, but the (b) New-styled Hanok1 (c) New-styled Hanok2 Figure 1. Three types of Hanoks for structural monitoring

108 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses (a) Raw wood used in traditional Hanok (b) Glued structural wood used in new-styled Hanok Figure 2. Raw wood and glued structural wood. Fig. 1(a) shows examples of a traditional Hanok built by traditional construction method and raw wood. Fig. 1(b) and Fig. 1(c) show new-styled Hanoks built by modernized construction method and glued structural wood. Fig 2(a) shows raw wood used in traditional Hanok, and Fig 2(b) shows glued structural wood used in new-styled Hanok. Researches on the timber structures have been carried out domestically and internationally. In Korea, researches were mainly carried out on the temple building, traditional Hanok, and palace building. Seo et al.[1] analyzed static and cyclic behavior of Korean traditional timber house with tenon joints under lateral load, and revealed that ancient Korean timber house has a significant nonlinear characteristics. Hwang et al.[2] extracted relationship between damping ratio and vibration amplitude of Korean traditional timber structure by shaking table test. Lee et al.[3], [4] evaluated load carrying capacity of Korean traditional timber structure according to various connection types. In China, Kang et al.[5] studied static performance of mortise and tenon joint in their traditional timber structure. And Fang et al.[6], [7] performed shaking table test on an ancient Chinese timber structure and evaluated its load carrying capacity. As researches on the new-styled Hanok, Kim [8] performed dynamic experiments on a two-storied 1/4 scale Hanok and compared the results with the eigenvalue analysis and extracted dynamic characteristics of the new-styled Hanok. Wood, used as the structural members of Hanok has its demerits that it splits as it dries. Moisture content is the main influential factor to the splitting of wood. As for the researches on the moisture contents in timber structures, Park et al.[9] evaluated distribution pattern of moisture contents in Korean traditional timber structure, and Kim [10, 11] monitored moisture contents and vertical deflection of both the traditional and the new-styled Hanok for about two years, and evaluated the relationship among wood types, relative humidity and moisture contents. In this study, as the extension of the previous study done by the author[10, 11] I monitored the surface moisture contents and vertical deflection of both the traditional Hanok and the new-styled Hanok for about two and a half years, and analyzed the monitored data to establish the basic standard for the long-term maintenance and management of Hanok. 2. Introduction of the Monitored Buildings The monitored test-bed Hanoks are located two cities, that is Yongin and Seoul. Seoul is the capital city of Korea, and Yongin is located about 40km south of Seoul. The traditional Hanok as shown in Fig. 1(a) and the new-styled Hanok1 as shown in Fig. 1(b) are located in Myongji University, Yongin. The new-styled Hanok2 is located in Eunpyeong Hanok town, which is about 10km north of center of Seoul. Geometric positions of these two cities are about 127 degrees east longitude and 37 degrees north latitude as shown in Fig. 3. Yongin and Seoul has a moderate climate with four distinct seasons. Their annual average temperature is about 12 C and annual average precipitation is about 1,300mm. The monitored buildings are composed of three Hanoks. One is a one-story traditional Hanok built by traditional

Civil Engineering and Architecture 3(5): 107-120, 2015 109 construction method as shown in Fig. 1(a) and Fig. 4(a). Another is a two-storied new-styled Hanok, called new-styled Hanok1, built by modernized construction method as shown in Fig. 1(b) and Fig. 4(b). The other is a two-storied new-styled Hanok, called new-styled Hanok2, built also by modernized construction method as shown in Fig. 1(c) and Fig. 4(c). The wood type, joint type and year of completion of these three Hanoks are summarized in Table 1. Raw wood was used for the traditional Hanok as its main structural members, whereas, glued structural wood was used for the two new-styled Hanoks. The joint type of traditional Hanok is mainly traditional mortise and tenon joint as shown in Fig. 5(a), whereas, that of the new-styled Hanoks is mainly steel plate and bolt joint as shown in Fig. 5(b)~(c). Traditional Hanok and new-styled Hanok1 were completed in May 2012, whereas new-styled Hanok2 was completed in August 2013. Figure 3. Location of test-bed Hanoks.

110 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses (a) Construction of traditional Hanok (b) Construction of new-styled Hanok1 (c) Construction of new-styled Hanok2 Figure 4. Construction process of three test-bed Hanoks. Table 1. Information for the Three Test-bed Hanoks Type of Hanok Wood type Joint type Year of completion Traditional Hanok raw wood mortise and tenon joint 2012.05 New-styled Hanok1 glued structural wood steel plate and bolt joint 2012.05 New-styled Hanok2 glued structural wood steel plate and bolt joint 2013.08

Civil Engineering and Architecture 3(5): 107-120, 2015 111 (a) Mortise and tenon joints in traditional Hanok (b) Steel plate and bolt joints in new-styled Hanok1 3. Monitoring Plan Structural monitoring for the traditional Hanok and new-styled Hanok1 were carried out since August 2012, and that of the new-styled Hanok2 was carried out since January 2014. The structural monitoring is scheduled to extend until October 2016. In this paper, the monitored data until February 2015 is analyzed. Fig. 6 shows monitored members for each three test-bed Hanoks. Surface moisture contents of columns were measured at their half height. Long-term deflections were monitored for horizontal structural members of roof, that is, angle rafters, plane rafters, and beams. Vertical deflections (c) Steel plate and bolt joints in new-styled Hanok2 Figure 5. Joint types of three test-bed Hanoks. were monitored by measuring distance from the reference point to the target point using laser distance measuring device. The reference point is located just below of each target point. Fig. 7(a) shows scenes of measuring moisture contents and vertical deflection. The measuring device for moisture contents is shown in Fig. 7(b), it is an electric-resistant device from TESTO Inc., and its model name is 606-2 with measurement error ±1%. The measuring device for deformation is shown in Fig. 7(c), it is from Leica Inc., and its model name is DISTO D5 with measurement error ±1mm. Monitored members for moisture contents and vertical deflections are summarized in Table 2 and Table 3, respectively.

112 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses The shapes of section of angle rafters and plane rafters for three Hanoks are the same. They have circular section. Section diameters of angle rafters and plane rafters of traditional Hanok and new-styled Hanok1 is 120mm, but those of the new-styled Hanok2 is 110mm. (a) Traditional Hanok (b) New-styled Hanok1 (c) New-styled Hanok2 Figure 6. Plan and elevation views and position of monitored members

Civil Engineering and Architecture 3(5): 107-120, 2015 113 (a) Measuring of moisture contents and roof deflection (b) Equipment for measuring moisture contents (c) Equipment for measuring deflection Figure 7. Measuring of moisture contents and deformation

114 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses Table 2. Monitored Members for Moisture Contents Type of Hanok Number of monitored columns Southern Northern Column size (mm) Traditional Hanok 3 2 210ⅹ210 New-styled Hanok1 3 2 180ⅹ180 New-styled Hanok2 4 3 210ⅹ210 Table 3. Monitored Members for Roof Deflection Type of Hanok Angle rafter Plane rafter Beam Traditional Hanok 3 2 4 New-styled Hanok1 5 2 4 New-styled Hanok2 5 43 4 4. Analysis of the Monitored Results 4.1. Moisture Contents and Column Location The moisture contents were analyzed based on three criteria that is column location to the sun, wood type, and relative humidity. The wood used for the three test-bed Hanoks is domestic larch wood. (a) Traditional Hanok (b) New-styled Hanok1

Civil Engineering and Architecture 3(5): 107-120, 2015 115 (c) New-styled Hanok2 Figure 8. Comparison of moisture contents according to column location to the sun for three test-bed Hanoks Fig. 8 shows moisture contents according to column location for the entire monitoring period. The columns at the north side of the building show slightly more moisture contents than those at the south side of building. Table 4 shows average moisture contents according to column location. The difference of moisture contents between southern and northern columns vary from 0.22% to 1.43%. It is 1.43% in the new-styled Hanok2 and 0.48% in the new-styled Hanok1 and 0.25% in the traditional Hanok. Though, the difference is small compared to the measurement error of ±1% of measuring equipment, the moisture contents of the northern columns are higher than those of the southern columns throughout most of the monitoring period as shown in Fig. 8. From this fact it can be deduced that the moisture contents are influenced by the sunlight in a certain degree. Type of Hanok Table 4. Comparison of Moisture Contents for Three Test-Bed Hanoks South (A) Average moisture content (%) North (B) Difference (B - A) Traditional Hanok 11.95 12.17 0.22 New-styled Hanok1 10.92 11.40 0.48 New-styled Hanok2 10.58 12.01 1.43 4.2. Moisture Contents and Wood Type In Fig. 9, moisture contents between traditional Hanok and new-styled Hanok1 is compared. These two Hanoks are different in their wood type. The traditional Hanok used raw wood, whereas the new-styled Hanok used glued structural wood as their main structural members. The traditional Hanok with raw wood showed more moisture contents than the new-styled Hanok for most of monitoring period. (a) Southern columns

116 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses (b) Northern columns Figure 9. Comparison of mean moisture contents between traditional Hanok and new-styled Hanok1 with different wood type In Table 5, the moisture contents of the three test-bed Hanoks are compared numerically. The moisture contents of the traditional Hanok turned out higher than that of the average moisture contents of the new-styled Hanok1 and new-styled Hanok2, that is, 1.20% in the southern columns and 0.47% in the northern columns. From this fact it can be deduced that the glued structural wood, which is made of small size rectangular wood, contains less moisture content than big sized raw wood from manufacturing, and this initial gap maintains thereafter. Type of Hanok Table 5. Comparison of Moisture Contents According to Wood Type South Average moisture contents (%) North Traditional Hanok (A) 11.95 12.17 New-styled Hanok1 (B) 10.92 11.40 New-styled Hanok1 (C) 10.58 12.01 difference (A (B+C)/2 ) 1.20 0.47 4.3. Moisture Contents and Relative Humidity It can be easily deduced that there may be somewhat linear relationship between surface moisture contents of wood and relative humidity. The region where the monitored buildings are located has four distinct seasons, where in summer high temperature and high humidity and in winter cold temperature and low humidity. Fig. 10 shows the variation of the mean relative humidity and the mean moisture contents of both the traditional Hanok and the new-styled Hanok1. In a rough way, they show similar variation pattern. Table 6 shows seasonal mean temperature and mean relative humidity numerically. Figure 10. Relationship between moisture contents and relative humidity for both traditional Hanok and new-styled Hanok1

Civil Engineering and Architecture 3(5): 107-120, 2015 117 Table 6. Seasonal Mean Temperature and Mean Relative Humidity Item Spring Summer Fall Winter mean temperature ( C) 11.9 25.3 14.5-1.0 mean relative humidity (%) 64.9 78.5 71.2 65.4 4.4. Vertical Deflection of Main Lateral Members From Fig. 11 to Fig. 13, deflections of angle rafters and plane rafters for the three test-bed Hanoks are showed graphically throughout the entire monitoring period. Angle rafters and plane rafters showed meaningful deflections, whereas beams showed little deflection. Although there are small fluctuations in the graph, the overall trends show gradual deformation as time goes by. In the graph, regression curves are also drawn to predict future deflection trends. In Table 7, the deflections of angle rafters are summarized. The mean vertical deflection of angle rafters, located on the corners of eaves, is 11.6mm in the traditional Hanok and 2.6mm and 5.8mm both in the new-styled Hanok1 s 1st and 2nd roofs respectively, and 2.1mm in the new-styled Hanok2. (a) Deflection of angle rafters (b) Deflection of plane rafters Figure 11. Deflection of traditional Hanok (a) Deflection of angle rafters

118 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses (b) Deflection of plane rafters Figure 12. Deflection of new-styled Hanok1 (a) Deflection of angle rafters (b) Deflection of plane rafters Figure 13. Deflection of new-styled Hanok2 The angle rafters of traditional Hanok showed 2~5 times more deflection than those of the new-styled Hanoks. The roof weight of the traditional Hanok weigh about 2~3 times more than those of the new-styled Hanoks, so the traditional Hanok showed more long-term deflection than the new-styled Hanok in angle rafters. In Table 8, the deflections of plane rafters are summarized. The mean vertical deflections of plane rafters, located between the angle rafters, show similar value for all the three test-bed Hanoks. The plane rafters showed more deflection than the angle rafters and this can be explained by considering supporting members. Angle rafters are supported by columns which have little vertical shortening, whereas, plane rafters are supported by beams which show relatively large deflections than columns. So, the deflections of the plane rafters were magnified by the deformation of their supporting members.

Civil Engineering and Architecture 3(5): 107-120, 2015 119 Table 7. Vertical Deflection of Angle Rafters for Three Test-Bed Hanoks Type of Hanok Roof position Angle rafter Deflection(mm) Mean deflection (mm) a 8.6 Traditional Hanok 1 st roof b 19.4 11.6 c 6.8 a 1.5 1 st roof 2.6 b 3.8 New-styled Hanok1 c 4.8 2 nd roof d 4.8 5.8 e 8.0 a 3.7 b 2.9 New-styled Hanok2 2 nd roof c -0.5 2.1 d 0.0 e 4.3 Table 8. Vertical Deflection of Plane Rafters for Three Test-Bed Hanoks Type of Hanok Roof position Plane rafter Deflection (mm) Mean deflection (mm) a 40.1 Traditional Hanok 1 st roof 21.5 b 2.9 1 st roof a -6.5-6.5 New-styled Hanok1 2 nd roof b 25.9 25.9 a 14.3 b 57.9 New-styled Hanok2 2 nd roof 20.3 c 11.8 d -2.6 5. Conclusions In this study I performed structural monitoring of the Korean traditional timber structure, called Hanok, to acquire basic data for maintenance and management. The moisture contents and vertical deflections were measured during two and a half years for three test-bed Hanoks, and the monitored data were analyzed. The moisture contents were analyzed focused on their relationship to the column location to the sun, wood types and relative humidity. The vertical deflections of main structural members of roof were analyzed focused on roof weight and supporting members. The columns at the north side of the building showed more moisture contents than those of the south side of the building. The traditional Hanok, which is made of raw wood showed more moisture contents than the new-styled Hanoks made of glued structural wood. As for the relationship between relative humidity and moisture contents, they showed similar variation pattern. The vertical deflection of angle rafters, plane rafters and beams for three test-bed Hanoks were also measured for about two and a half years. Angle rafters and plane rafters showed meaningful deformation. It can be deduced that, the deformation are mainly affected by roof weight and supporting members. But for the detailed analysis, the deformation needs to be monitored for more monitoring period. This research is scheduled to extend another two years. It is expected that total of four years of monitoring would explain the relationship among moisture contents, roof deformation, and material properties of wood. Acknowledgements This work was supported by a grant (14AUDP-B070934-02) from Urban and Architecture Research Program funded by Ministry of Land, Infrastructure and Transport Affairs of Korean Government. REFERENCES [1] J. M. Seo, I. K. Choi, J. R. Lee, Static and cyclic behavior of wooden frames with tenon joints under lateral load, Journal of Structural Engineering, vol. 125, no. 3, pp. 344-349, Mar. 1999. [2] J. G. Hwang, S. G. Hong, Y. W. Lee, S. J. Jung, Natural Frequency Characteristics of Traditional Wooden Structure

120 Monitoring of Vertical Deflection and Moisture Contents in Korean Traditional Timber Houses for Vibration Amplitude, Journal of the Architectural Institute of Korea : Structure & Construction, vol. 25, no. 5, pp. 3-10, May. 2009. [3] Y. W. Lee, B. S. Bae, S. G. Hong, J. G. Hwang, N. H. Kim, S. J. Jung, An Analytical Modelling of the Beam-Direction Frame of Traditional Wood Structure System, Journal of the Architectural Institute of Korea : Structure & Construction, vol. 22, no. 3, pp. 29-36, Mar. 2006. [4] Y. W. Lee, S. G. Hong, J. G. Hwang, B. S. Bae, Capacity of Lateral Load Resistance of Dori-Directional Frame with Jangbu-connection in Traditional Wood Structure System, Journal of the Architectural Institute of Korea : Structure & Construction, vol. 23, no. 2, pp. 35-42, Feb. 2007. [5] M. Kang, N. Yang, Q. Cha, Studies on Static Performance of Mortise and Tenon Joint in Traditional Column and Tie Construction Timber Structure, Electric Technology and Civil Engineering (ICETCE), 2011 International Conference, pp. 6197-6200, 2001. [6] D. P. Fang, S. Iwasaki, M. H. Yu, Q. P. Shen, Y. Miyamoto, H. Hikosaka, Ancient Chinese Timber Architecture I: Experimental Study, Journal of Structural Engineering, vol. 127, no. 11, pp. 1348-1357, Nov. 2001. [7] D. P. Fang, S. Iwasaki, M. H. Yu, Q. P. Shen, Y. Miyamoto, H. Hikosaka, Ancient Chinese Timber Architecture Ⅱ : Dynamic Characteristics, Journal of Structural Engineering, vol. 127, no. 11, pp. 1358-1364, Nov. 2001. [8] Y.M. Kim: Dynamic Experiments on a 1-4 Scale New-styled Korean Traditional Wooden House. Applied Mechanics and Materials, 2014, Vol 598: 743-746. [9] C. H. Park, G. C. Kim, Study on Moisture Contents Distribution of Wooden Post Member by Precise Monitoring in Un-Bong Confusion School, Journal of the Korea Furniture Society, vol. 21, no. 1, pp. 104-112, Jan. 2013. [10] Y.M. Kim: Monitoring of Moisture Contents in Korean Traditional Wooden Houses. In Proceedings of the World Congress on Engineering 2014, London, England, June 2-4, 2014, pp.1298-1303. [11] Y.M. Kim: Deformation Monitoring in Korean Traditional Test-bed Hanok in Myongji University, Civil Engineering and Architecture, vol.3, no.2, pp.38-42, 2015.