PART TWO 2. WATER SUPPLY

Similar documents
Hygiene Standards for all Food Businesses

Water Coolers and Dispensing Machines:

Name of Business. Record 1- Approved Food Suppliers List

Control of legionella bacteria in water systems

PART TWO 5. PEST CONTROL

BIOSECURITY PROCEDURES IN POULTRY PRODUCTION

FOOD SAFETY MANAGEMENT SYSTEM

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Level 4 Award in HACCP Management for Food

Qualification Specification HABC Level 3 Award in Supervising Food Safety in Catering (QCF)

TURKISH FOOD CODEX COMMUNIQUÉ ON RAW MILK AND HEAT PROCESSED DRINKING MILK (Communiqué Number: 2000/6)

The course and qualification may be taken as a stand-alone certificate, or as part of a wider course of training.

EMERGENCY ACTION PLAN CONTAMINATED WATER SUPPLY (BIOLOGICAL)

This Food Safety Plan was developed in New York as an example for growers. Each grower must develop their own plan which fits their operation.

STUDY GUIDE: ABATTOIR HYGIENE

CONCEPTS OF FOOD SAFETY QUALITY MANAGEMENT SYSTEMS. Mrs. Malini Rajendran

Parts per million (ppm) or Milligrams per liter (mg/l): one part by weight of analyte to 1 million parts by weight of the water sample.

THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO A bylaw to amend Storm Sewer Bylaw No. 1402, 1986

SAFE HEALTHY CHILDREN A Health and Safety Manual for Childcare Providers

Emergency Guideline for Food Facilities during Boil Water Advisory or Other Public Notices

Ultra Violet Disinfection

STANDARD OPERATIVE PROCEDURE. Notification of the establishments that export quick-frozen vegetables from Third Countries to Italy

PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK PROCEDURE EMERGENCY (TEMPORARY) TREATED WATER SUPPLIES

Healthcare Water System Repair Following Disruption of Water Supply

Food Safety Act (as amended) Code of Practice No. 7: Sampling for Analysis or Examination (Revised October 2000)

CAC/RCP , Rev

BULK WATER HAULING GUIDELINES

Division of Epidemiology, Environmental and Occupational Health Consumer and Environmental Health Services

HEALTH AND SAFETY IN THE FOOD INDUSTRY DETECTING HARMFUL MICROORGANISMS HEALTH AND SAFETY PRECAUTIONS (EXAMPLES FROM CONQUEST FOODS)

Guidance document on reporting under the Drinking Water Directive 98/83/EC

Food Safety Guidance for Farmers Markets

Good Hygiene Practices for Catering at Outdoor Events

Water and Wastewater. Sample Collection and Analysis

FOOD LAW ENFORCEMENT IN SCOTLAND

General food hygiene rules

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems

6. Principles of effective plumbing systems

Protecting your private water supplies. The possible causes of contamination and their remediation to prevent this risk.

There may be an additional section covering health and safety concerns which fall outside the scope of the national food hygiene rating scheme.

This quick guide provides a summary of food safety and labelling advice for small scale home producers of chutneys, pickles, flavoured oils and jams.

Address of food business: 67 London Street, Norwich, NR2 1HL Date of Inspection: 13 May 2013

COOLING WATER MANAGEMENT

How to Prepare Powdered Infant Formula in Care Settings

CLEANING AND SANITIZING

PPG21. Pollution Prevention Guidelines. pollution incident response planning: PPG Introduction

CAC/RCP , Rev

Level 2 Award in. Food Safety in Catering (QCF) Specification. Ofqual Accreditation Number 600/0343/1

Making sure your private water supply is safe Rainwater

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

CONTROL PLANS IN FOOD SAFETY MANAGEMENT SYSTEMS

STUDY GUIDE: POULTRY MEAT EXAMINATION

National Food Safety standard of the People s Republic of China

Level 4 Award in Food Safety Management for Manufacturing

Water should be removed as soon as possible once the safety of the structure has been verified.

A Guide to Trouble-Free Cooling Towers

Permit Number: 7.0/048904/JT

Private Water Supplies Sampling Manual. A Field Guide

A quick guide to our floodcare scheme

STARTING A NEW FOOD BUSINESS? GUIDELINES FOR OPENING A CLASS 3 FOOD BUSINESS

2016 No WATER, ENGLAND AND WALES. Water Supply (Water Quality) Regulations 2016

Water Treatment Filtration Lab. discharged into an aquatic ecosystem? We had to build a water filtration system with

GUIDELINES. for COTTAGE INDUSTRY INVOLVED in HOME FOOD PRODUCTION

PBX Series Quick Fit Connector Bimetallic Steam Traps

LAB 37 Edition 3 June 2013

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

Address of food business: 25 Ranworth Road, Norwich, NR5 8EB Date of Inspection: 27 July 2015

Water Quality Contingency Planning Standard EPB 540B

Domestic Chemical Water Treatment Manufacturers Association

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

CONTROL OF LEGIONELLA AUDIT PROFORMA

Food delivery & storage

Draft guidance for registered pharmacies preparing unlicensed medicines

EUROPEAN COMMISSION GUIDANCE DOCUMENT

Code of Practice on the responsible use of animal medicines on the farm

CODE OF HYGIENIC PRACTICE FOR DRIED FRUITS (CAC/RCP )

HACCP and ISO food safety management synergies with Environmental Management System

SOUTH CAROLINA. Downloaded January 2011

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

4. HOUSE RULES TEMPERATURE CONTROL

Examples of pressure systems and equipment are:

FACT SHEET. Users That Must Take Particular Precautions During A Boil Advisory

ONLINE VERSION ONLINE VERSION

Legislative background to the Private Water Supplies Regulations 2009 Section 9(E&W) of the Private Water Supplies: Technical Manual

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Standard Interpretation and Application

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

APPROVED ARRANGEMENT GUIDELINE ~ WILD GAME MEAT

ASI 691 Prinicples of HACCP 1

Lead Understanding Lead Exposure

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

Emergency Drinking Water Supply

The machine and bulk milk tank cleaning process

POLICY REF NO. SABP/CARE ENVIRONMENT/0002

Legionella Managing Risk. Judith Richardson Director Qube Environmental Asbestos & Legionella Management

Food Defense Self-Assessment Checklist for. Slaughter and Processing Plants

oil care Looking after your heating oil in the south east

TEMPORARY FOOD ESTABLISHMENT EVENT APPLICATION

How to Use Water Safely in Your Food Establishment During a Boil Water Advisory

Transcription:

PART TWO 2. WATER SUPPLY Section Page 2. Contents 1 2.1 Why is the quality of the water supply important? 2 2.2 What are the legal requirements for water supply? 2.2.1 Which operations does the law apply to? 3 2.2.2 What are the operator s legal obligations? 3 A General Requirements B Water Quality Requirements C Specific Requirements for Meat Production 2.2.3 What are the official control requirements? 4 2.3 How may operators demonstrate compliance? 5 2.3.1 Water supply 6 2.3.2 Use of potable water 8 2.3.3 Maintaining and monitoring the water supply 10 PART TWO 2.WATER SUPPLY 1

2.1 WHY IS THE QUALITY OF THE WATER SUPPLY IMPORTANT? Water is an important potential source of microbiological and chemical hazards. Microorganisms that cause food poisoning can survive for days or even months in water. Procedures are needed to minimise the risk of such hazards causing illness to consumers. For example: Water supplies can become polluted with human sewage or agricultural waste containing faecal contamination from animals. Such pollution is likely to contain microorganisms that can cause human disease. Bacteria are able to multiply in water distribution systems, even when the incoming water supply is not contaminated, especially where water remains for a long time in storage tanks or pipes that are not in use. The problem will be greater if the water system is not kept clean. The resulting microbiological contamination can then spread to other parts of the system and be transferred to food. Water supplies can also be a source of chemical contaminants, such as heavy metals, pesticides, nitrates, and industrial pollutants. These chemical contaminants can be transferred from water used in processing or cleaning onto food. PART TWO 2.WATER SUPPLY 2

2.2 WHAT ARE THE LEGAL REQUIREMENTS FOR WATER SUPPLY? 2.2.1 WHICH OPERATIONS DOES THE LAW APPLY TO? Operations Red Meat Slaughter White Meat Slaughter Approved Farm Slaughter Farmed Game Handling Wild Game Handling Meat Cutting and Production of Meat Products, Mince Meat, Meat Preparations and MSM Edible By Products Relevant Sections of 2.2.2 below A, B, C A, B, C A, B A, B, C A, B A, B, C A, B 2.2.2 WHAT ARE THE OPERATOR S LEGAL OBLIGATIONS? A. GENERAL REQUIREMENTS 1. The design and construction, of food premises are to permit good food hygiene practices, including protection against contamination. 2. Food premises are to be kept clean and maintained in good repair. 3. Washbasins for cleaning hands are to be provided with hot & cold running water. 852/2004 Annex II Food premises: Chapter I points 1, 2(c) and 4 B. WATER QUALITY REQUIREMENTS Potable water means water meeting the minimum requirements laid down in Directive 98/83/EC on the quality of water intended for human consumption. 852/2004 Article 2 Definitions: point 1(g) 1. There is to be an adequate supply of potable water, which is to be used whenever necessary to ensure that foodstuffs are not contaminated. 2. Where non-potable water is used, e.g. for fire control, steam production, refrigeration and other similar purposes, it is to circulate in a separate, duly identified system. Non-potable water is not to connect with, or allow reflux into, potable water systems. PART TWO 2.WATER SUPPLY 3

3. Recycled water used in processing or as an ingredient is not to present a risk of contamination. It is to be of the same standard as potable water, unless the competent authority is satisfied that the quality of the water cannot affect the wholesomeness of the foodstuff in its finished form. 4. Ice which comes into contact with food or which may contaminate food is to be made from potable water. It is to be made, handled and stored under conditions that protect it from contamination. 5. Steam used directly in contact with food is not to contain any substance that presents a hazard to health or is likely to contaminate the food. 6. Where heat treatment is applied to foodstuffs in hermetically sealed containers, it is to be ensured that water to cool the containers after heat treatment is not a source of contamination for the foodstuff. 852/2004 Annex II Water supply: Chapter VII point 1(a) 2 6 7. Food business operators shall not use any substance other than potable water - - to remove surface contamination from products of animal origin, unless the substance s use has been approved. 853/2004 Article 3 point 2 C. SPECIFIC REQUIREMENTS FOR MEAT PRODUCTION 1. [Meat plant] Operators must have facilities for disinfecting tools with hot water supplied at not less than 82 C, or an alternative system having an equivalent effect. 853/2004 Annex III: Slaughterhouses: Section 1 Chapter II point 3 & Section II Chapter II: point 3 / Cutting: Section I Chapter III point 5 & Section II Chapter III point 1e / Farmed Game: Section III points 1 & 2; / Production Establishments: Section V Chapter I point 5 / Meat Products: Section VI point 2. 2.2.3 WHAT ARE THE OFFICIAL CONTROL REQUIREMENTS? Audits by officials of good hygiene practices shall verify that meat plant operators water quality procedures are applied continuously and properly. 854/2004 Article 4 point 4g PART TWO 2.WATER SUPPLY 4

2.3 HOW MAY OPERATORS DEMONSTRATE COMPLIANCE? Food Business Operators may demonstrate compliance with their legal obligations for the quality of the water supply on an ongoing basis by providing evidence, including appropriate documentation, that: New, rebuilt altered or refurbished premises are sited, designed, laid out, constructed and equipped so as to provide an adequate supply of potable water for use in food production and water at a suitable temperature for handwashing. Procedures are in place to ensure that only potable water (or for the removal of surface contamination an approved substance) is used for operations where food contact could occur by: Applying a disinfection process if necessary. Clearly identifying and preventing the use of non-potable water systems (e.g. fire control systems, or refrigeration systems). Making and using only ice made from potable water, and storing it so that it does not become contaminated. Ensuring that steam that may come into direct contact with meat does not contain any additives or contaminants that are not approved for food use. Ensuring that water to cool hermetically sealed containers after heat treatment does not contaminate the product. Ensuring that only approved substances are used as directed for the removal of surface contamination from products of animal origin. Arrangements are in place to maintain and monitor the water supply and take corrective action if there is a failure. PART TWO 2.WATER SUPPLY 5

2.3.1 WATER SUPPLY GUIDE TO COMPLIANCE Supply of Potable Water The design and construction of the premises permits good food hygiene practices. An adequate and reliable supply of potable water is provided for food processing, cleaning and other procedures where food contact is possible. A1, B1 Directive 98/83/EC is implemented in England and Wales by The Water Supply (Water Quality) Regulations 2000 (www.legislation.hmso.gov.uk/si/si2000/ 20003184.htm ) For further information contact the Drinking Water Inspectorate Ashdown House, 123 Victoria Street, London, SW1E 6DE, Telephone: 020 7082 8024 (www.dwi.gov.uk) [Directive 98/83/EC is implemented in Scotland by ] Directive 98/83/EC is implemented in Northern Ireland by The Water Supply (Water Quality) Regulations (NI) 2002 (SI 2002 /331 as amended by SI 2002/369). Supply of Potable Water Consider the need for adequate water supplies for food processing, cleaning and other requirements in the design and construction of premises or when buildings are rebuilt, altered or refurbished. See Chapter 1 (Design & Facilities). For technical information contact: the Water Regulations Advisory Scheme (www.wras.co.uk) telephone: 01495 248454 Potable water must meet the minimum requirements of Directive 98/83/EC. It may be drawn from the public mains supply network operated by a water company, or from a private supply, such as a borehole. See Monitoring at 2.3.3 below. Capacity ensure that the water distribution system has sufficient capacity to meet demand at peak times (e.g. during cleaning). Water pressure- an initial mains water pressure of at least 20 psi is likely to be necessary to ensure that sufficient water is available throughout the plant. Water storage tanks - should be made of inert material to avoid chemical contamination of water and corrosion. Keep tanks covered and secured to prevent contamination. Plans - water distribution systems can be complex, especially in larger premises. Detailed plans will help to identify any redundant pipe work that could act as a reservoir of microbiological contamination and to define an area to be isolated if contamination occurs. Keep an accurate and dated plan of the potable and PART TWO 2.WATER SUPPLY 6

any non-potable system, including pipe work, point of entry of water into the premises and numbered outlets (see monitoring below). Update the plan if alterations are made. Plans must be submitted with applications for approval. Water Temperature Washbasins for cleaning hands are provided with hot and cold running water. Water Temperature Supply water at suitable temperatures for effective hand washing without risk of scalding. See also Chapter 7 (Personal Hygiene). A3 Cleaning & Maintenance The premises are to permit adequate maintenance and cleaning. A2 Cleaning & Maintenance Keep water distribution systems in good condition and maintained so that water does not become contaminated. Clean tanks regularly to prevent any build up of organic or mineral material that could act as a source of microbial growth and contamination. Even well maintained water distribution systems suffer from a build up of organic matter over time. To prevent this from affecting water quality, it is good practice to drain and clean the entire system at least annually as well as when any contamination incident occurs. Maintenance inspections carry out regular inspections of the water distribution systems for signs of damage, corrosion, leaks etc. The frequency of inspection will depend on the likelihood of a problem being found (once a month may be sufficient for welldesigned premises that are kept in good order). Keep an accurate, dated account (e.g. in a maintenance notebook) of the date and result of each inspection and of any corrective action taken. Disinfection Where water is drawn from a private supply it may require chlorination or equivalent PART TWO 2.WATER SUPPLY 7

disinfection treatment to ensure that it is of potable quality. It is advisable to consult a water treatment specialist to help identify the most effective method. Chlorination - if used, chlorination systems should allow a minimum contact time of 15 minutes during periods of maximum demand, and require a suitably sized storage tank to hold the water before it enters the distribution system. An automatic chlorination system is preferable, with an analyser fitted with an alarm and a recorder to monitor the process continuously and indicate any malfunction. Have the system checked periodically to confirm it is functioning correctly and periodically to ensure that the correct free residual chlorine level (Note: not total chlorine) is being maintained within the range of 0.2-0.4 parts per million (ppm). Chlorine levels should not exceed 0.5ppm see Corrective Action below. Alternatives to chlorination these include filtration and disinfection with ultra-violet light. They require maintenance e.g. filter systems need to be cleaned and/or changed regularly to maintain performance. Water softening - in hard water areas water softening may be applied to prevent the build up of scale and reduce the use of detergents. If used, keep water softeners in good condition so that they do not become sources of contamination. 2.3.2 USE OF POTABLE WATER GUIDE TO COMPLIANCE Training and instruction Food business operators ensure that food handlers are supervised and instructed and/or trained in food Training and instruction Instruct staff (and any contract cleaners) about the need to use potable water (including ice and steam if appropriate), to use only water from the correct PART TWO 2.WATER SUPPLY 8

hygiene matters commensurate with their work activity. 852/2004 Annex II Chapter XII point 1 outlets and report problems promptly. Staff who take or test water samples need to be adequately trained so that results are reliable. Supervise as appropriate and issue reminders if lapses occur. See also Chapter 6 (Training). Keep accurate, dated records to show what instruction/training individuals have received. Use of non-potable water Where supplies of non-potable water are used (e.g. for fire control, non-food contact steam generation, or refrigeration), they are carried in completely separate and clearly identified distribution systems. Non-potable water does not connect with, or allow reflux into, potable water systems. Use of non-potable water Clearly identify potable and non-potable water systems and particularly water outlets to avoid misuse of non-potable water. See also Plans above. Make sure there are no opportunities for non-potable water to enter the potable distribution system, for example, through siphoning back from a drain. B2 Recycled Water Where water is recycled for use in processing or as an ingredient, it is the same standard as potable water, unless the competent authority is satisfied that the quality of the water cannot affect the wholesomeness of the foodstuff in its finished form. Recycled Water If recycled or re-circulated water is used, carry out daily tests and keep a record of the results. B3 Use of ice Ice which comes into contact with food or which may contaminate food is made from potable water. It is made, handled and stored under conditions that protect Use of ice Keep ice storage containers covered. Clean and periodically disinfect them to ensure that they do not become contaminated. PART TWO 2.WATER SUPPLY 9

it from contamination. B4 Use of Steam Use of Steam If steam is used for direct contact with meat, it is generated from potable water, and does not contain potentially harmful contaminants. B5 Heat Treatment Heat Treatment If water is used to cool hermetically sealed containers after heat treatment it does not contaminate the product B6 Water for Disinfecting Tools Water is used for disinfecting tools has a minimum temperature of 82 o C. Water for Disinfecting Tools Make sure water temperatures reach at least 82 o C, but avoid temperatures above 90 o C. C1 Removal of Surface Contamination Only potable water or EU approved substances are used for the removal of surface contamination from meat or other products of animal origin. The conditions of use are followed. Removal of Surface Contamination Submit proposals for alternative systems to the Veterinary Director, Food Standards Agency, 125 Kingsway, London WC2 6NH. B7 2.3.3 MAINTAINING AND MONITORING THE WATER SUPPLY GUIDE TO COMPLIANCE Operator Responsibilities The operator is responsible for food safety in the food business. Operator Responsibilities Operator Responsibility includes maintaining and monitoring the company s water supply and taking PART TWO 2.WATER SUPPLY 10

852/2004 Article1 point 1a corrective action if there is a failure. Delegation responsibility for maintaining and monitoring water quality procedures may be delegated to a nominated person who knows the layout of the water distribution system, to whom problems are reported, and has sufficient authority to ensure that corrective action is taken when necessary. Monitoring there should be regular checks that company procedures are being followed regarding use of potable water, inspections of the water distribution system, reporting of problems, maintenance, and any microbiological monitoring. Frequency of monitoring - this will depend on the likelihood of a problem being found. Once a month may be sufficient if staff are experienced and procedures are unchanged. The work of new or temporary people who are less familiar with the procedures and premises may need to be monitored more frequently. Records keep an accurate, dated account (e.g. in a maintenance notebook) of the date and result of the periodic monitoring checks, test results and of any corrective action taken. Microbiological monitoring mains water Monitor the following microbiological parameters to check that the water being used is of potable quality and that contamination is not occurring after the water enters the premises: Total viable count at 22 o C after 72h. Total viable count at 37 o C after 48h. E.coli Coliform Bacteria PART TWO 2.WATER SUPPLY 11

Enterococci Clostridrum Perfringens (including spores) if water originates from or is influenced by surface water e.g. boreholes. Mains Water The water supplier is required to monitor the quality of mains water entering the premises. A copy of their test results can be obtained. Mains water with intermediate storage tanks If mains water is stored in tanks before use and/or if the water distribution system is complex and/or the system is old, it can become contaminated after entering the premises. Periodic testing of water samples from cold or mixed hot/cold water outlets where the water could come into direct contact with food, food processing equipment, or food handlers, will indicate whether microbiological contamination is occurring on site or whether the water is potable. [Current Commission guidance on Meat Plant Inspections expects monthly testing.] Microbiological monitoring private supplies Local councils monitor the quality of private supplies, but this may not happen often. A copy of their test results can be obtained. Extra tests or tests on a new supply may be arranged with the council for a charge or can be arranged using a private laboratory. A test can only indicate the quality of the water at the time of that test. The quality of the water may change at different times. Testing samples at least once a month will indicate whether microbiological contamination is occurring on site or whether the water is potable. [Current Commission guidance on Meat Plant Inspections expects monthly testing.] PART TWO 2.WATER SUPPLY 12

Sampling of Water Water samples need to be taken carefully so that no contamination is introduced when the sample is taken. Staff should receive training to ensure that results are accurate and consistent. Label all samples with the correct sample point as inaccurate labelling will delay the identification of the source of any contaminated samples. If the water has been chlorinated, the sample bottle should contain sodium thiosulphate to neutralise the effect of any remaining chlorine. For further information on sampling see The Microbiology of Drinking Water (2002) - Part 2 - Practices and procedures for sampling obtainable on www.environment-agency.gov.uk Laboratories Ideally use laboratories that are accredited by a recognised body for E.coli etc test methods in water samples or that participate in proficiency testing schemes such as LEAP (e-mail leap@csl.gov.uk), Health Protection Agency WEQA scheme (www.hpaweqa.org.uk) or Quality Management (www.qualitymanagement.co.uk). Interpretation of results Total viable count (TVCs) - the results of TVC tests can be used to assess the water quality around the plant. Guideline figures for acceptable TVC values are: TVC at 22 o C after 72h - 100 per ml. TVC at 37 o C after 48h - 10 per ml. Regular samples from the same points on the system can indicate a developing contamination problem. PART TWO 2.WATER SUPPLY 13

Any two-fold or greater increase in counts that are above these guideline figures should be classified as a low level positive. Coliform Bacteria - If coliform bacteria are found at levels above 3 per 100 ml of water, in two consecutive samples, or in more than 5% of samples taken within a year, this may indicate contamination in the water distribution system, and action must be taken see high level positives below. Coliform levels below this are classified as a low level positive and further sampling is advisable see below. E.coli - If E.coli is detected in water, this is evidence of contamination by animal or human faeces. This is a serious food safety risk and action must be taken see below. Follow up actions High level positives Do not use the water outlet or tank from which the sample was taken (and associated outlets if necessary) until the contamination has been investigated and eliminated and satisfactory microbiological results have been obtained from further samples taken at the point of entry, the outlet from which the contaminated sample was taken and any other associated outlets Follow up actions Low level positives Re-sample and test for all faecal indicators. If a further low level positive result is obtained, but there is no evidence of faecal contamination, investigate the source of the problem. Corrective action Water supply entering the premises - if this becomes contaminated, it is the water supplier s or PART TWO 2.WATER SUPPLY 14

local authority s responsibility to restore potable water quality. Follow their directions concerning water use and product safety. Contamination after entering the premises - if the water supply becomes contaminated after entering the premises or non-potable water comes into contact with food, take corrective action to ensure food safety, such as: Isolating appropriate water outlets/tanks until satisfactory microbiological test results are obtained; Stopping production if necessary; Dealing with any product that has been contaminated; Reviewing sampling and testing procedures; Establishing the underlying cause and what needs to be done to prevent similar incidents in the future; and Improving staff instructions and training. PART TWO 2.WATER SUPPLY 15