Mini pressure switch Stainless steel switch enclosure Model PXS

Similar documents
Compact pressure switch Flameproof enclosure Ex d Model PCA

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Pressure transmitter For general industrial applications Model A-10

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Bypass level indicator With magnetic display Model BNA

Differential Pressure Transmitter Model DPT-10

Technical Data. Dimensions

Bimetal thermometer Model 52, industrial series

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

B-Series Switches Pressure, Differential Pressure & Hydraulic

Explosion proof enclosures

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

2.12. page Products for Explosion hazardous Environment

Flow switches Series AD/VH

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical data sheet TDS0070

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

B-Series Temperature Switches

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Solenoid Valve Island Type 3965

Control and Distribution Boxes made of Stainless Steel Series 8150

Plastic tube flowmeters Series PT/PS

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Inductive slot sensor

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Technical Information RIA14

Threaded resistance thermometer Model TR10-C, with protection tube

Technical Data. Dimensions

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Precision digital pressure gauge Model CPG1500

distributing & controlling system solutions

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Linear Luminaire with LED Series EXLUX 6402/2

OPTIMASS 6000 Technical Datasheet

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Terminal Boxes Series 8146

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Scraper Passage Indicator. Electrical Indicator. Features

Thermometer in stainless steel with capillary and switch contacts

Assisted lift operated 2/2-way solenoid valves Type EV250B

Connection technology from ifm.

Series 8146/5-V37 and Series 8150/5-V37

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Relative pressure transmitter type 520

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

TEIP11 I/P signal converter for standard signals. Measurement made easy

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

SEISMIC VELOCITY TRANSDUCER T1-40

Solenoid valves 2/2-way direct-operated Type EV210A

SITRANS F flowmeters SITRANS F M

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Worcester DS/DM Series UltraSwitch Switch box

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

A good connection. International approvals.

Micro Motion 3098 Gas Specific Gravity Meter

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Hand-held thermometer Model CTH7000

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

4/2-Way Pneumatic Solenoid Valve

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Terminal Box. Specifications TNCN

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Instructions for Safe Use

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Technical Specifications

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

CAPACITIVE LEVEL METERS CLM 36

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Variable V Area Flowmeter Rotameter The Original

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Operating Instructions

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Solenoid valves Type EVU

Operating Instructions

Microcor Wireless Transmitter (MWT)

3/2-way Solenoid Valve, direct-acting, NC or NO

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Cables. Accessories. For Force, Torque and Strain Sensors

Plug and Socket Devices CES 63 A Series 8579

ISO/VDMA Actuators. Engineering GREAT Solutions

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Micro Motion Model D and DL Coriolis Flow and Density Meters

Operating Instructions

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Transcription:

Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical applications in general process instrumentation, especially in the chemical and petrochemical industries, oil and gas industries, power generation incl. nuclear power plants, water/wastewater industries, mining For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience For measuring points with limited space, e.g. control panels Special features No power supply needed for switching of electrical loads Robust switch enclosure from stainless steel 316L, IP66, NEMA 4X Setting ranges from 1... 2.5 bar to 200... 1,000 bar Intrinsic safety Ex ia available 1 set point, SPDT, high switching power up to AC 250 V, 5 A Mini pressure switch model PXS Description These high-quality pressure switches have been developed especially for safety-critical applications. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested. In order to ensure as flexible operation as possible, the pressure switches are fitted with micro switches, which enable the switching of an electrical load of up to AC 250 V, 20 A directly. For lower switching power ratings, such as for PLC applications, argon gas-filled micro switches with gold-plated contacts can be selected as an option. All wetted materials are from stainless steel as a standard. For applications with special requirements on the wetted parts, versions with materials from Hastelloy are available. Moreover the snap-acting behaviour of the Belleville spring increases stability and vibration resistance. WIKA data sheet PV 34.36 05/2016 Page 1 of 5 Data sheets showing similar products: Pressure switch; Ex d; model PXA; see data sheet PV 34.38

Standard version Switch enclosure Stainless steel 316 Tamper-proof Laser-engraved product label from stainless steel Ingress protection IP66 per EN/lEC 60529, NEMA 4X Permissible temperature Ambient T amb : -40... +85 C Medium T M : See table on next page. Depending on measuring element. Switch contact Hermetically sealed micro switches with fixed dead band. 1 x SPDT (single pole double throw) Ignition protection type (option) Ex ia I Ma (mines) Ex ia IIC T6/T4 1) Ga (gas) Ex ia IIIC T85/T135 1) Da (dust) 1) The temperature class is related to the ambient temperature range. See the type examination certificate for further details. Safety-related maximum values (only for Ex ia versions) Maximum values Voltage U i Current l i Power P i Internal capacitance C i Internal inductance L i DC 30 V 100 ma 0.75 W 0 μf 0 mh Contact version Electrical rating (resistive load) Suitable for AC DC Ex ia option E 1 x SPDT, silver, hermetically sealed 250 V, 5 A 24 V, 5 A Yes J 1 x SPDT, gold-plated, hermetically sealed 250 V, 0.5 A 24 V, 1 A Yes Set point adjustment The set point can be specified by the customer or factory-set within the setting range. Subsequent adjustment of the set point on site is made using the adjustment screw, which is covered by the access cover plate with lead seal option. Repeatability of the set point 1 % of span Please specify: Set point, switching direction for the contact, e.g.: Set point: 5 bar, rising After removing the access cover plate, set point adjustment can be made using the adjustment screw. The set point is selectable within the entire setting range. For optimal performance we suggest to adjust the set point between 25... 75 % of the setting range. Example Setting range: 1... 2.5 bar with one switch contact Repeatability: 1 % of 1.5 bar = 0.015 bar Dead band: 0.3 bar (see table setting ranges) 2 x repeatability + dead band = 2 x 0.015 bar + 0.3 bar = 0.33 bar Rising pressure: Adjust set point between 1.33... 2.5 bar. Falling pressure: Adjust set point between 1... 2.17 bar. Process connection (A) Stainless steel 316L ¼ NPT female (standard) ½ NPT, G ½ A, G ¼ A male via adapter ½ NPT, G ¼ female via adapter M20 x 1.5 male via adapter Electrical connection Connection cable Length: 1.5 m Wire cross-section: 0.5 mm² (20 AWG) Insulation material: Silicone Threaded connection (B) Material: AISI 316 - ½ NPT male (standard) - M20 x 1.5 male (adapter) - M20 x 1.5 female (adapter) - ½ NPT female (adapter) - ¾ NPT female (adapter) Terminal box Dielectric strength Safety class I (IEC 61298-2: 2008) Mounting option Direct Wall bracket from stainless steel Option: Mounting bracket for 2 pipe mounting Weight 0.6 kg (standard) 1.1 kg, with terminal box Page 2 of 5 WIKA data sheet PV 34.36 05/2016

Measuring element Measuring element Wetted parts Permissible medium temperature (T M ) M Welded diaphragm with antagonist spring Hastelloy C276-40... +200 C G Piston with antagonist spring and welded diaphragm Hastelloy C276-40... +140 C P Piston with antagonist spring Stainless steel 316L, O-ring FPM 1) 0... 200 C 1) The measuring element is a piston, therefore particularly suited for liquid media. Setting range Measuring range Measuring element Setting range depending on the switching direction in bar Working range Proof pressure in bar rising falling in bar in bar in bar 1... 2.5 M 1.3... 2.5 1... 2.2 0... 10 16 0.3 1.6... 4 M 2.1... 4 1.6... 3.5 0... 10 16 0.5 2.5... 10 M 3.5... 10 2.5... 9 0... 10 16 1.0 6... 20 M 7.5... 20 6...18.5 0... 40 60 1.5 14... 40 M 17... 40 14... 37 0... 40 60 3.0 20... 100 P, G 35... 100 20... 85 0... 500 750 15 40... 160 P, G 65... 160 40... 135 0... 500 750 25 50... 400 P, G 85... 400 50... 365 0... 500 750 35 150... 700 2) P 250... 700 150... 600 0... 1,000 1,500 100 200... 1,000 2) P 345... 1,000 200... 855 0... 1,000 1,500 145 Max. dead band 2) Repeatability of the set point 1.6 % of span Options Cleaned for oxygen service Drying of wetted parts Measuring element piston with O-ring NBR (permissible medium temperature: -10... +110 C) NACE compliant to MR 0175, ISO 15156 and MR 0103 Terminal box, aluminium alloy, copper-free epoxy resin, coated with 3 connections ½ NPT female, ingress protection IP65 Grounding cable cross-section: max. 4 mm² Other cable length: 3 m, 5 m Offshore version Assembly (Option) Shut-off valve model 910.11, see data sheet AC 09.02 Barstock valve model 910.81, see data sheet AC 09.18 Diaphragm seals, see website WIKA data sheet PV 34.36 05/2016 Page 3 of 5

Approvals Logo Description Country EC declaration of conformity Pressure equipment directive Low voltage directive ATEX directive 1) II 1 GD IECEx 1) per IEC 60079-0, IEC 60079-11, IEC 60079-26 (option) Ex ia I Ma Ex ia IIC T6/T4 2) Ga Ex ia IIIC T85/T135 2) Da European Community IECEx member states EAC (option) Hazardous areas (option) KOSHA (option) Hazardous areas Eurasian Economic Community South Korea 1) Double marking ATEX and IECEx on the same product label. 2) The temperature class is related to the ambient temperature range. Certificates (option) 2.2 test report per EN 10204 3.1 inspection certificate per EN 10204 Approvals and certificates, see website Page 4 of 5 WIKA data sheet PV 34.36 05/2016

Dimensions in mm Standard version Measuring element M Measuring element G Measuring element P Legend Access cover plate Stainless steel wire A Pressure connection Lead seal Adjustment screw B Electrical connection Set point adjustment rod Ø 3 mm Option: Terminal box Option: Wall bracket Ordering information Model / Measuring element / Contact version / Measuring range / Process connection / Electrical connection / Options 2009 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. WIKA data sheet PV 34.36 05/2016 Page 5 of 5 05/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de