Care and Maintenance of Steam Systems

Similar documents
Best Practice in Boiler Water Treatment

The National Board of Boiler and Pressure Vessel Inspectors 1055 Crupper Avenue Columbus, Ohio

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

BASIC WATER TREATMENT OF STEAM BOILERS

2014 Service Technician Training Program Closed Loop Systems

WATER TREATMENT THE NEED FOR CONTROL COMMON IMPURITIES FOUND IN WATER. CALCIUM CARBONATE (CaCO3) CALCIUM SULFATE (CaSO4) MAGNESIUM SULFATE (MgSO4)

A Primer on Protecting Idle Boilers By Howard Benisvy, Member ASHRAE

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Case History Report The Dolphin Nonchemical Device Boilers and Cooling Tower

Some Criteria for Choosing a Steam Boiler for a Microbrewery

steam centre of excellence Steam Boiler System Optimization

THE USE OF OZONE IN COOLING TOWERS

Boiler Preparation, Start-Up and Shutdown

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.

Technical Presentation IMPORTANT TOPICS

Boiler Blowdown Analysis In An Industrial Boiler

Sulfites for Oxygen Control

12 Ways To Avoid Boiler Tube Corrosion

ALS TRIBOLOGY Engine Coolant Reference Guide

WATER CHEMISTRY AND POOL WATER BALANCE

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

A Guide to Trouble-Free Cooling Towers

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

NON-HAZARDOUS CHEMICAL TREATMENTS FOR HEATING AND COOLING SYSTEMS

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

IGEMA BOILER LEVEL & TDS CONTROLS

Energy Efficient Operations and Maintenance Strategies for Boilers

Inferred ph in Steam Plant Water Chemistry Monitoring

BOILER EFFICIENCY F7 Energy eco-efficiency opportunities in Queensland Foundries

Chapter 2.2: Boilers

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Routine and Emergency Boiler Operation

This chapter is devided into two sections:

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

COOLING WATER MANAGEMENT

Cat S O SSM. Services. Understanding Your Results. Understanding Your: S O S Oil Reports S O S Oil Results S O S Coolant Reports S O S Coolant Results

TABLE OF CONTENT

Hydrogen Exchange Resin. Steam Purity Analysis

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

I. STEAM GENERATION, BOILER TYPES

SUGAR MILL BOILER CYCLE CHEMISTRY: AN UPDATE ON BEST PRACTICES DAVID RODMAN. Nalco Australia Pty Ltd, Townsville

Corrosivity of Water Supplies

Scale and Deposit Formation in Steam Assisted Gravity Drainage (SAGD) Facilities

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

WATER-SOLUBLE METALWORKING FLUIDS

CHALLENGES IN A DILUTION STEAM GENERATOR SYSTEM

C. Provide temporary water treatment for chilled, hot and condenser water until facility has final connections.

Industrial Water Reuse and Wastewater Minimization

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

INTAC PARTS & SERVICES ( H)

Water Treatment Program Manual

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

FLASH TANK ECONOMIZER PRODUCT GUIDE

Energy Efficiency in Steam Systems

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

High-Pressure Steam Cycle and Boiler Water Treatment

Food Protection Services

Energy Saving Fact Sheet Boilers

Troubleshooting tips Key. What colour is the water? Reddish-orange. Yellowish-brown or tea-coloured

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Introducing an All New Line of Cleaning Chemicals

DEGASSED CATION CONDUCTIVITY MEASUREMENT

Organic Chemistry Lab Experiment 4 Preparation and Properties of Soap

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

NORKOOL Industrial Coolants

Ion Exchange Softening

REQUEST FOR QUOTE FOR WATER TREATMENT SERVICES OKALOOSA COUNTY BOARD OF COMMISSIONERS, FLORIDA

Steam Generation Efficiency Module Blowdown Losses Section

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

MILKING SYSTEM CLEANING AND SANITIZING: TROUBLESHOOTING MILK BACTERIA COUNTS. Alan Monken and Winston Ingalls West Agro, Inc. Kansas City, Missouri

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

WATER TABLE WINNERS!

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

WATER TREATMENT GLOBAL PRODUCT SELECTION GUIDE

Boiler Efficiency. Charles Stark Department of Poultry Science.

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Steam System Efficiency. Bill Lumsden Leidos Engineering

Petroleum refining water/wastewater use and management

How To Clean Up A Reactor Water Cleanup

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.

A SHORT INTRODUCTION TO CORROSION AND ITS CONTROL

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Metal Rescue Rust Remover Technical Data

Water Treatment & Purification Chemicals

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

The chemical components of detergents and their roles in the washing process

NALCO BT-25 Boiler Internal Treatment

Forgotten savings: Heat recovery from surface blowdown

AIR-CONDITIONERS CONDENSATE RECOVERY SYSTEM FOR BUILDINGS

Adjusting Chemical Levels in a Swimming Pool

Factory owners must ensure the boiler is:

HVAC Schedule. Contract # GS-07F-9452S Contract # GS-06F-0091S 2008 NCH CORPORATION 2009 NCH CORPORATION

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

Transcription:

Care and Maintenance of Steam Systems February 2010 Brrr. It's been a cold winter so far. Good thing we've all got heating systems that take care of us and take care of themselves, right? Of course not. One of the primary concerns in a heating system is maintenance. Lack of maintenance can ultimately lead to premature boiler failure, which does not reflect well on a capital improvement program and makes for an even colder season. Care and maintenance includes: proper chemical treatment daily blowdown proper inspections Contaminants in Steam Systems Steam systems require careful attention to water treatment needs. After being used for heating or power, the steam condenses and is returned to the boiler through the condensate lines. Not all of the water that was turned to steam comes back. Steam systems need makeup water to compensate for the water lost as the steam circulates through a system. Both the condensate and the makeup water can bring contaminants into the system. In fact, the feedwater that is piped into the boiler usually contains solids. These solids join the solids that were left behind by the water that has already turned to steam. The concentration of solids in the water increases every time makeup water is added to a boiler, so these solids must be treated or purged to prevent problems. Steam systems are most affected by scale, foaming and carryover, and corrosion. Sludge buildup and caustic embrittlement can also reduce boiler efficiency. Scale in Boilers Scale in boilers inhibits efficient heat transfer. Scale buildup of 1/8 inch can reduce heat transfer by 15 percent. Take a look at how scale increases your energy costs:

Steam Scale Condition Generation lbs/hr 1/64 in. (2% heat loss) 1/32 in. (4% heat loss) 1/16 in. (6% heat loss) 5,000 $5,600 $11,600 $18,000 10,000 $11,200 $23,200 $36,000 20,000 $22,400 $46,400 $72,000 50,000 $56,000 $116,000 $180,000 Assumptions: 1) 100 psi boiler operating on natural gas 24 hours/day, 365 days/year 2) Gas cost = $0.40/therm ($4.00/M Cu. Ft.) 3) Boiler efficiency = 80% Scale in boilers needs to be controlled to ensure system efficiency. Sodium phosphate compounds can be added to boiler water to help prevent scale formation. The sodium phosphate compound helps precipitate scale-forming material so that the precipitated material can be blown down in boilers. Boilers can be cleaned with power tools designed to cut or knock scale from the tubes. In firetube boilers, scale forms on the outside surface of the tubes. The scale is knocked loose by running a vibrating hammer or rattler through the tube. When the scale is knocked loose, it can then be flushed down a boiler drain. In watertube boilers and cooling tower condensers, scale forms on the inside of the tubes. The scale is removed from the inside surface by using rotary brushes or cutters. This procedure is called rodding. Foaming and Carryover in Boilers Foaming is an excess of turbulence on the surface of the water in the boiler. This is caused by a high concentration of impurities in the water. Foaming prevents the operator from determining if the water level in the boiler is correct or not. Carryover happens when the water level is too high and particles of liquid water from the boiler are transported into the steam lines. Carryover is harmful because these small water droplets can cause damage to the steam pipes as they change direction in the lines. There are several ways to prevent foaming and carryover. Using silicone and ethoxylated-alcohol reduces foaming. Maintaining an appropriate schedule for blowdowns can reduce foaming and carryover. Using a centrifugal separator with vanes that take water out of steam before it goes into the lines can prevent carryover.

A daily test of the condensate water can determine if carryover is occurring. If the condensate has a high TDS (total dissolved solids) reading or chemicals are present, carryover is occurring. A surface skimming blowdown valve is one method for controlling impurity levels. This valve, unlike a regular valve, has a meter scale attached to it so that the operator can adjust how open the valve is. By opening this valve in precise measurements, boiler water impurities can be removed gradually over a long period of time by skimming water from the top of the boiler. When maintenance work is done on a boiler, extreme care should be taken to prevent oil from getting into the system. Oil is harmful because it makes sludge sticky and increases the possibility of foaming and carryover. Oil in water will act as insulation on the water side of metal surfaces, causing an increase of the temperature of that part of the metal. This can eventually lead to blistering. If a small amount of oil gets into the system: add a highly alkaline compound, boil flush To combat large amounts of oil: drain the boiler clean with a commercial solvent. Corrosion in Boilers Corrosion can be a serious problem in boiler maintenance. Chemicals are used to prevent corrosion that can come from high ph (alkalinity) or from oxygen dissolved in the water. Corrosion in boilers also occurs when water is too acidic. Boiler water should be maintained at a ph of 10.1 to 11. Sodium hydroxide can be used to increase ph. In steam boilers, a slightly alkaline water system will help control scale and prevent corrosion in the steam lines. In the closed loops of hot-water systems and chilled-water systems, it will prevent rust and corrosion. Steam that leaves the boiler is usually acidic and requires neutralizing or filming amines treatment to prevent corrosion in the steam and condensate lines. However, amines cannot be used if the steam is used for humidity control in an air-handler system. Oxygen carryover into the steam and condensate lines can lead to pitting corrosion. Pitting corrosion is directly related to the dissolved oxygen that is present in boiler water systems. Sodium sulfite can be fed into a boiler to prevent pitting caused by dissolved oxygen. Sodium sulfite should be fed directly and simultaneously to the area where the feedwater make-up is occurring. If a condensate tank is used in the steam system, the treatment should occur in the condensate tank. A high feedwater temperature reduces the oxygen level in the water, therefore it is recommended to keep the feedwater temperature as high as possible. The presence of 30 to 60 ppm of residual sodium sulfite in boiler

water will help remove dissolved oxygen because sodium sulfite acts as an oxygen scavenger. However, too much sodium sulfite can cause an acidic condition. A precise chemical treatment is important to keep costs and maintenance reasonable. Sludge in Boilers Suspended solids are dispersed and eliminated from the system through periodic blowdown. Chemicals are used to disperse suspended solids, which are then purged from the boiler through blowdown. The water column, feedwater controller, and city water make-up controller need to be blown down as well to reduce sludge and ensure that the float mechanisms work properly. Blowdown is the release of water from a valve that draws water from the bottom of the boiler. In boilers, this process causes calcium and magnesium to precipitate, fall out of solution, and create sludge. After these minerals are changed into sludge, they can be purged by blowdown. Polymers, tannins, lignins, and alginates can be used as sludge conditioners. These organic materials surround the scale precipitates and prevent them from adhering to metal in the boiler. The chemicals used to cause calcium and magnesium to precipitate and form sludge are a combination of sodium hydroxide, sodium carbonate, and sodium phosphate and organic treatment such as lignins or tannins. Some of the chemicals commonly found in boiler water and heating water systems are listed below. Chemical Closed water system Steam boiler Corrosion Inhibitors Scale Inhibitor Sodium Nitrite Sodium Metaborate Sodium Molybdate Phosphonates Caustic adds alkalinity to systems Sulfite oxygen pitting inhibitor Neutralizing Amines corrosion inhibitor Polymers Phosphonates EDTA-Chelants Phosphate Boiler Blowdown Connection Steam boilers are designed with two blowdown connections: one to remove the dirt and oil that collect on top of the water in the boiler (the evaporation surface) and one to purge the boiler of sediments that collect on the bottom of the boiler shell. The device used to bleed off water on the top of the boiler is called a surface blowdown. A surface blowdown (or skimmer) uses a special metered ball valve which can be adjusted. For instance, a valve can be set to allow 1/2 gallon of water an hour to be skimmed off of the surface of the boiler. The valve setting would be set to 0.5. This process allows the water to be exchanged with new water over a period of time, for

instance 24 hours. Blowdown connections should be opened on a daily basis to remove foreign matter from the heating system. More Information This article is adapted from BOMI International's The Design, Operation, and Maintenance of Building Systems, Part 1. This is one of several BOMI courses recently approved by the US Green Building Council for maintaining your LEED-AP credential. More information regarding this is available by calling 1-800- 235-2664, or by visiting BOMI International's website.