Specifically designed for concrete basins and porous substrates

Similar documents
Building Owners Guide to a Duro-Last System!

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Waterproofing construction Joints

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

BLACK JACK ALL WEATHER ROOF COATING

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

WATERPROOFING OF WET ROOMS

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Mold Preventing I nterior System

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Material Product Data Sheet Sealers for Thermal Spray Coatings

SikaProof A Technology

Secondary Containment Comparison ATI Ultra COAT vs HDPE

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

The following document contains information on Cypress products.

WATERPROOFING SikaProof -A TECHNOLOGY

Plastics Engineering SYSTEM BEKAPLAST. Mechanically anchored thermoplastic lining for extreme conditions

The Anatomy of a Label

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Winterizing Your Trailer and Storage Ideas

ENVIRONMENTAL EFFECTS ON COATINGS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Rehabilitation of an Aging Concrete Reservoir Adit Tower

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

Automotive Engineered Attachment Systems

Radiation Curable Components and Their use in Hard, Scratch Resistant Coating Applications

GigaCrete Specification PlasterMax

Division 9. SignaFlor Pad and Pour Flooring System

1.5. UL flammability ratings. *Nylon 6.6 = Polyamide 6.6 is Halogen-free and Silicone-free.

BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

Set-Up Instructions. (Liner-Based System) UL LISTED. Important Read set-up instructions before assembly. Report any shortages within 72 hours

Peel & Seal Self-Stick Roofing Solutions

Section Polished Concrete Finishing. Vexcon

PTFE Slide Bearings 04/10 149

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

Application Guide Selection of Type Enclosures

Process Control For Phosphate Coating A new military specification for phosphate coatings...

Phone: FAX: website: GUIDE TO INSULATION FASTENING

Corrosion protection linings. Issue 1

TERMOSIGN APPLICATION INSTRUCTIONS

Oil and Gas Pipeline Design, Maintenance and Repair

OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground

Green Thread Product Data

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Colorado State University. Durrell Center Roof Repair

SC2000 CEMENT BONDING PROCEDURES

PRODUCT DATA SHEET DESCRIPTION:

Low VOC Performance Protection Systems

LASER PRINTING PROBLEM SOLVER

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Aspect Metal Peel & Stick Tile Installation Guide

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Flexible Spill Containment Protecting You And The Environment

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

CHAPTER 8- REDUCING THE MOISTURE

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

List of Frequently Utilized Storage Tank Standards and Practices

Technical Data Sheet February 2014

A. Work on this project shall consist of, but is not limited to, the following:

Liquid Leakage Sensor Amplifier

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Metal Wall Panels. Colorweld 300 Architectural Finishes

3M Scotchkote Urethane Coating 165HB

3.8 HSP (High Solids Polyurethane)

Product Guide Specification

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

GUIDELINE SPECIFICATIONS

Wecryl Waterproofing System under surfacing supplied by others

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION

Renovation instructions

High Performance PSA in Sheet Membrane in Water Protection

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

RHINO HYDE URETHANE SHEETING

Spandrel Glass Types and Recommendations

Are these noise cancelling devices needed to make your chiller quiet??

WOOD FLOORING MAINTENANCE MANUAL

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Solar Heating and You

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

White rust on galvanized and galvanized pre-painted steel. Technical Information

pvc well casing & drop pipe

Transcription:

Specifically designed for concrete basins and porous substrates Team@thermalspraysolutions.com

POLYX LINER is a modified thermoplastic copolymer sheet specifically for the use on concrete or other porous surfaces. Its purpose is to be resistant to everyday environmental stress cracking (ESC), as well as adverse weather conditions, chemical cleansers, salts and typical airborne pollutants and chemical degradation. Features: Eco Friendly PolyX Water repellent capabilities Provides a resilient and lasting coating system Dielectric insulation properties Excellent resistance to impact and abrasion

POLYX LINER Revolutionary Coating Solution For Porous Materials POLYX LINER system is primarily used for coating concrete surfaces, flooring, containers, pipes, tanks, discharge ducts, ceramic areas, and fiberglass bottoms. ECO friendly liner can be used in large walk-in refrigeration units or fresh water tanks. Non- toxic, safe for environment and workers.

Pump for glue adhesive Simple working single-phase feed Positioned POLYX LINER sheets are pressed with a to improve the application and remove blisters Extrusion system joins liner sheets by applying the same POLYX material. Welds are tear-resistant. Preparation of substrate Substrates must have stable dimensions and consistency, solid, flat, smooth and non-absorbent. Substrates need to be dry, free of rising damp or cracks, clean, with NO release agents or dust. Treat for absorbing concrete areas so sub-base is weather-proof using a twin-compound epoxy product. Application Glue is recommended to apply the POLYX LINER sheet to concrete. Welding the POLYX LINER plate is chosen according to type of project proposed on site. Mechanically through anchors or inserts.

POLYX LINER is available with several surface modifications: Standard smooth - Standard for most applications (Water tanks, basins, pools) Anti-slip - Industrial flooring, safety for employees (With seam joint) With Anchors- For anchoring in the concrete during installations of new walls With Metallic Support- Created to give anchoring in concrete extra stability Glow in the dark - for safety areas, markers, walk ways etc. (Not Pictured) Antibacterial- For food areas such as kitchens and freezers (Not Pictured) Liner Versions

POLYX LINER VS. LIQUID PAINTS Painting on concrete substrates does not ensure long-lasting protection in our experience due to: Application on un even substrate (concrete morphology, and chemically unstable) Difficult paint applications due to high humidity and air entrapment. Various thickness and uneven surfaces can cause peeling or entrapment. Painting will NOT allow gases and fluids to reach concrete surface, creating deterioration over time. Most of these issues weaken the concrete structure which cannot be immediately detected without a thorough investigation. Warehouse floor with corrosion from moisture and uneven substrate problems. POLYX LINER on roofing. No damage to the coating or humidity transfer after 1 year.

Substrate: Concrete tank POLYX LINER LONG TERM SUCCESS Galvanizing plant- Italy, 2002 Specifications: Acid resistant liner Results: First POLYX LINER still in excellent conditions after more than 10 years in operation today.

POLYX LINER Data Recommended liner thickness 2000-2500 um Abrasion Taber ASTM D4060/84 weight loss: 60 mg H18, weight: 500g, 1000 cycles Chemical resistance - Diluted acids 60 C Good - Diluted alkali 60 C Good - Salts (except peroxides) 60 C ** Good Resistance to weather conditions QUV ASTM G53-77 2000 hours - No significant change in color or loss of gloss. Florida 45 facing South 3 years - No significant change in color or loss of gloss. Burning characteristics Ignitability BS476: Pt5: 1979 P - not easily ignitable 500 u, coating Surface flame propagation BS476: Pt7: 1979 Class 1 500 u coating Flame propagation BS476: Pt6: 1989 I = 0.2 500 u coating Flammability UL94 V o (see also Material Properties) Safe working temperature (continuous in air) 60 C - 70 C max according to the version used *These values may vary from color to color and according to the copolymers used on the basis of the purpose of use. Storage: Store liner sheet in a dry area at room temperature.