LAMINATED VENEER LUMBER

Similar documents
FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

SECTION METAL WALL PANELS

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

FLOOR TREATMENT 09610

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

SECTION METAL ROOF & WALL PANELS

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PART 1 GENERAL 1.1 SECTION INCLUDES

MASTERFORMAT SPECIFICATION

SECTION WARDROBE AND CLOSET SPECIALTIES PART 1 - GENERAL

SECTION STORAGE SHELVING. Copyright ARCAT, Inc. - All rights reserved

Residential Deck Safety, Construction, and Repair

Product Guide Specification

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section: SPECIFIER NOTE:

SECTION STANDING SEAM METAL ROOFING

STANDARD OPEN PATIO COVER

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Code of Standard Practice for Timber Frame Structures

2. Division 05 Structural Steel Framing for steel framework requirements

Chapter 6 ROOF-CEILING SYSTEMS

Bracing Webs in Trusses that have Dissimilar Configurations

Uncovered Decks & Porches

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Toll Free:

SECTION PREFORMED METAL STANDING SEAM ROOFING

City of San Diego, CWP Guidelines

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Discipline: Structural Issued

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

SECTION WINDOW WASHING SYSTEMS

TYPICAL PATIO COVERS 111

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION GUARDA SECURITY WINDOW SCREENS

POST AND FRAME STRUCTURES (Pole Barns)

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

LANSING COMMUNITY COLLEGE TLC BUILDING SERVER ROOM UPGRADES SECTION SUBMITTAL PROCEDURES PART 1 - GENERAL 1.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Acceptance Codes APPENDIX - A. Acceptance Criteria

ABOUT CWB CERTIFICATION/ QUALIFICATION The work CWB does on behalf of our clients can be divided into five main categories:

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

CLEAR-DIVISIONS CENTERFOLD

December J-Ply Roofing, Flooring and Decking

March 14, Installation of Bay, Bow and Garden Windows

High Strain Dynamic Load Testing of Drilled Shafts

Component Solutions Software Suite

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Preformed Metal Roofing and Siding

Patio Covers / Carports

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

Typical Deck Details

SECTION 1 GENERAL REQUIREMENTS

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Chapter 3 Pre-Installation, Foundations and Piers

INSTALLATION. General. Important Note. Design. Transport

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

CSC-DIVISION 1-MASTER SECTIONS Description

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION SERIES 1500 VINYL PATIO DOORS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Post and Beam Construction

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Pigeon Spike Stainless Economy Bird Spikes Includes specifications for: Pigeon Spike Stainless models, hardware and surface cleaning.

CITY OF LOS ANGELES CALIFORNIA

Wall braces with a swivel head are included to accommodate all roof pitches.

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

Residential Decks. Planning and Development Services Department

PDmB, Inc. Definitions

GYPSUM AREA SEPARATION FIREWALLS GA

PERFORMANCE RATED I-JOISTS

DESIGN CLARIFICATION (DC)

LP OSB Sheathing & Structural 1 Sheathing

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Architectural Concrete Masonry

CLEAR-DIVISIONS APERTO

ADDENDUM #2 FORMAL BID

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Page & Turnbull imagining change in historic environments through design, research, and technology

Transcription:

This Manu-Spec utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM), including MasterFormat, SectionFormat and PageFormat. A Manu-Spec is a manufacturer-specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate product model numbers, styles and types are used in Specifier Notes and in the specification text Article titled Acceptable Material. Metric conversion, where used, is soft metric conversion. This Manu-Spec specifies laminated veneer lumber (LVL) headers, beams and studs. These products are manufactured by. Revise Manu-Spec section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. 10599 Old Hwy 99 South Dillard, OR 97432 Phone: (800) 245-1115 Fax: (541) 679-2543 E-mail: ewpsales@rfpco.com Web: www.roseburg.com SECTION 06 17 13 LAMINATED VENEER LUMBER PART 1 GENERAL 1.1 SUMMARY A. Section Includes: This Section specifies laminated veneer lumber (LVL) headers, beams and studs. Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI MasterFormat and specifier s practice. B. Related Sections: 1. Connectors and Brackets, Anchor Bolts, Bearing Plate Anchors, and Hardware: Division 05 metal fabrication sections. 2. Permanent Bridging and Bracing and Sheathing: Division 06 carpentry sections. 3. Framing Connectors and Hangers: Division 06 carpentry sections. Specifier Note: Paragraph below may be omitted when specifying manufacturer s proprietary products and recommended installation. Retain References Paragraph when specifying products and installation by an industry reference standard. List retained standard(s) referenced in this section alphabetically. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Contract Conditions or Section 01 42 00 - References may establish the edition date of standards. This Paragraph does not require compliance with standard(s). It is a listing of all references used in this section. Only include here standards that are referenced in the body of the specification in PARTS 1, 2 and/or 3. Do not include references to building codes at any level. 1.2 REFERENCE STANDARDS A. The Engineered Wood Association (APA): 1. Product Report: PR-L289 B. ASTM International (ASTM): 1. ASTM D5456 Standard Specification for Evaluation of Structural Composite Lumber Products. 1

2. ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials. C. Canadian Construction Materials Centre (CCMC): 1. CCMC Report Number 13310-R. D. Forest Stewardship Council A.C. (FSC): 1. STD-40-003 Standard for Multi-site Certification of Chain of Custody Operations. 2. STD-40-004 V2.0 FSC Standard for Chain of Custody Certification. 3. STD-40-005 V2.1 Standard for Company Evaluation of FSC Controlled Wood. E. ICC Evaluation Service Inc. (ICC-ES): 1. ICC-ES Report Number ESR-1210. 1.3 ADMINISTRATIVE REQUIREMENTS A. Coordination: Coordinate work of this Section with work of other trades for proper time and sequence to avoid construction delays. Comply with Section [01 31 00 - Project Management and Coordination]. Specifier Note: Add additional text to specify unusual or detailed coordination requirements affecting the work results of this Section. 1. [ ]. 1.4 ACTION SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Section [01 33 00 - Submittal Procedures]. B. Product Data: Submit for specified products as follows: 1. Manufacturer s product data, including descriptions of component materials, dimensions of specified products, design properties, allowable spans and construction details. 2. Manufacturer s installation instructions. 3. Catalog pages illustrating products to be incorporated into project. 4. Material Safety Data Sheets (MSDS). Specifier Note: Retain the following paragraph only if members are to be designed by the contractor. C. Shop Drawings: Submit drawings sealed by the designer indicating member types, sizes, locations and connection details. D. Design Data: Submit design calculations sealed by the designer for representative structural members. Specifier Note: Article below should include prerequisites, standards, limitations and criteria that establish an overall level of quality for products and workmanship for this section. Coordinate article below with Division 01 Quality Assurance Section. 1.5 INFORMATION SUBMITTALS Specifier Note: Specify submittal of test reports or evaluation service reports intended to document required tests without repeating the test requirements specified in Division 01. A. General: Submit listed submittals in accordance with Contract Conditions and Section [01 33 00 - Submittal Procedures]. Specifier Note: Specify submittals intended to document manufacturer installation, storage and other instructions. B. Manufacturer s Instructions: Submit manufacturer s [storage] [and] [ ] installation instructions. C. Source Quality Control: Submit documentation verifying that components and materials specified in this Section are from a single manufacturer. 1.6 CLOSEOUT SUBMITTALS A. General: Submit listed submittals in accordance with Contract Conditions and Section [01 33 00 - Submittal Procedures]. 2

1. Warranty Documentation: Submit warranty documents specified. 1.7 QUALITY ASSURANCE Specifier Note: Retain paragraph below only if members are to be designed by the contractor. A. Designer Qualifications: A professional structural engineer registered in the [State of ] [state where the project is located]. 1.8 DELIVERY, STORAGE & HANDLING A. General: Comply with Section [01 61 00 - Common Product Requirements]. B. Delivery and Acceptance Requirements: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. Unload material in accordance with manufacturer s recommendations. C. Storage and Handling Requirements: Handle and store materials in accordance with manufacturer s recommendations. Protect from exposure to harmful environmental conditions. D. Packaging Waste Management: Specifier Note: The disposal of packaging waste into landfill sites demonstrates an inefficient use of natural resources and consumes valuable landfill space. Specifying appropriate packaging and construction waste management and disposal procedures may contribute to points required for USGBC s LEED construction project certification. Specifier Note: Include the following Subparagraphs to specify information that will provide direction to the Contractor for the disposal of construction waste materials using environmentally responsible methodology other than landfill resources. 1. Separate waste materials for [reuse] [and] [recycling] in accordance with [Section 01 74 19 - Construction Waste Management and Disposal]. Specifier Note: USGBC s LEED certification includes credits for the diversion of construction waste from landfill. Diversion can be tracked by either weight or volume but must be consistent for all materials. Manufacturer may reclaim packaging and delivery materials for recycling. 2. Remove packaging materials from site and dispose of at appropriate recycling facilities. 3. Collect and separate for disposal [paper] [plastic] packaging material [in appropriate onsite bins] for recycling. 4. Fold metal and plastic banding; flatten and place in designated area for recycling. Specifier Note: Add additional Subparagraphs to include pallets, crates, padding and other packing materials that are typically associated with the specified products. 5. Remove: a. Pallets from site [and return to supplier or manufacturer]. b. [ ]. PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal, or approved equal or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal products. 2.1 LAMINATED VENEER LUMBER Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to Manu-Spec. Retain or delete paragraph below per project requirements and specifier s practice. 3

A. Manufacturer:. 1. Contact: 10599 Old Hwy 99 South, Dillard, OR 97432; Telephone: (800) 245-1115; Fax: (541) 679-2612; E-mail: ewpsales@rfpco.com; website: www.roseburg.com. 4 2. Single Source Responsibility: Provide components and materials specified in this section from a single manufacturer. Specifier Note: Substitution procedures must appear either in the Contract Conditions or in Section 01 25 00 - Substitution Procedures. Do not include substitution procedures here. 3. Substitution Limitations: a. Substitutions: [In accordance with [Contract Conditions] [Section 01 25 00 - Substitution Procedures]] [No substitutions permitted]. Specifier Note: Include an overall description of the system, assembly, product or material. Include required properties or characteristics that do not obviously belong under other titles. Examples: Configuration, size and color. B. Description: Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Contract Conditions and Section 01 41 00 - Regulatory Requirements. Repetitive statements should be avoided. 1. Regulatory Requirements: a. In accordance with Section [01 41 00 - Regulatory Requirements]. Specifier Note: Select appropriate code reference(s) below. b. Comply with ICC-ES Report Number ESR-1210. c. Comply with CCMC Report Number 13310-R. d. Comply with APA Product Report PR-L289. e. [ ]. 2. Sustainability Characteristics: a. Comply with the following FSC Standards: 1) STD-40-003. 2) STD-40-004 V2.0. 3) STD-40-005 V2.1. b. [ ]. 3. Compatibility: a. Ensure components and materials are compatible with specified accessories and adjacent materials. Specifier Note: The term Design Criteria is used when describing the intended characteristics of a product for which the Contractor is assigned design responsibility. Retain Paragraph below only if members are to be designed by the contractor. C. Design Criteria: Specifier Note: Select and/or insert loading criteria to conform to project requirements. 1. Design Live [and Dead] Load for Floors: [ ] psf (kg/m 2 ) with live load deflection limited to [ 1 600] [ 1 480] [ 1 360] [ ] of span or a maximum of [ ] inches of live load deflection and total load deflection limited to [ 1 360] [ 1 240] [ 1 180] of span or a maximum of [ ] inches of total load deflection. 2. Design Live [and Dead] Load for Roofs: [ ] psf (kg/m 2 ) with live load deflection limited to [ 1 480] [ 1 360] [ 1 240] [ ] of span or a maximum of [ ] inches of live load deflection and total load deflection limited to [ 1 360] [ 1 240] [ 1 180] of span or a maximum of [ ] inches of total load deflection. D. Materials: 1. Laminated Veneer Lumber: To ASTM D5456.

a. Laminated Veneer Lumber Studs: To ASTM E119. Specifier Note: Retain type(s) below to conform to project requirements. If more than one is retained, create designators and coordinate with the drawings. If members are to be designed by the contractor, delete the next two paragraphs. 2. Plies: [1 ply] [2 ply] [3 ply] [4 ply]. 3. Thickness: [1 1 2 inches (38 mm)] [1 3 4 inches (44 mm)] [3 1 2 inches (89 mm)] [5 1 4 inches (133 mm)] [7 inches (178 mm)]. 4. Grade: [1.3E] [1.5E] [2.0E] [2.2E] [2.3E] RigidLam LVL. Specifier Note: Insert height below unless indicated on the drawings. 2.2 ACCESSORIES 5. Depth: [ ] [As indicated on drawings]. Specifier Note: Retain fastener type below to conform to project requirements. A. Fasteners: [Galvanized steel] [Stainless steel], sized to suit application. 1. Acceptable Manufacturers: a. Simpson Strong-Tie. b. USP Structural Connectors. PART 3 EXECUTION 3.1 EXAMINATION A. Verification of Conditions: Verify that conditions of substrates previously installed under other sections or contracts are acceptable for product installation in accordance with manufacturer s instructions prior to laminated veneer lumber (LVL) headers, beams and studs installation. 1. Inform [Owner] [Architect] [Consultant] of unacceptable conditions immediately upon discovery. 2. Proceed with installation only after unacceptable conditions have been remedied [and after receipt of written approval from [Owner] [Architect] [Consultant]]. 3. [ ]. 3.2 INSTALLATION A. Coordinate installation of laminated veneer lumber (LVL) headers, beams and studs in accordance with Section [01 73 19 - Installation]. B. Coordinate laminated veneer lumber (LVL) headers, beams and studs work with work of other trades for proper time and sequence to avoid construction delays. C. Comply with manufacturer s product data, including product technical bulletins, product catalog installation instructions and product carton instructions, for installation. D. Install members plumb, level and as indicated. E. Fasten members to supporting framing as recommended by the LVL manufacturer and the hanger manufacturer. F. Provide temporary bracing to hold members in position until permanently secured. G. Cut holes in members only as allowed by the manufacturer. 3.3 CLEANING A. Perform cleanup in accordance with Section [01 74 00 - Cleaning and Waste Management] and Section [01 74 13 - Progress Cleaning]. B. Upon completion and verification of performance of installation, remove surplus materials, rubbish, tools and equipment in accordance with Section [01 74 23 - Final Cleaning]. 5

Specifier Note: Specify special measures needed to minimize waste, collect recyclable waste and dispose of or recycle fieldgenerated construction waste created during demolition, construction or final cleaning. C. Waste Management: 1. Coordinate recycling of waste materials in accordance with Section [01 74 19 - Construction Waste Management and Disposal]. 2. Collect recyclable waste and dispose of or recycle field generated construction waste created during demolition, construction or final cleaning. 3. Remove recycling containers and bins from site. END OF SECTION 6