GE Industrial Solutions. Residential Electronic Circuit Interrupters

Similar documents
Arc Fault Circuit Interrupters Frequently Asked Questions

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

Protect your home and family with Advanced Technology from Cutler-Hammer

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

AFCIs Come of Age. by Douglas Hansen

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put it into perspective: Electrocutions can be Prevented

CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

WHITE PAPER: HOME REMODELING & AFCI PROTECTION

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

HOUSING QUALITY STANDARDS (HQS)

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Home Electrical Safety

For Models #6-5001, #6-7501, # & #10-12K1

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Retail Reference Guide Answers for infrastructure.

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Help protect your home, possessions and family.

Electrical Resistance Resistance (R)

A guide to understanding and maintaining your home s electrical system. A publication presented by the Electrical Safety Foundation International

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

HOME ELECTRICAL Safety Checklist

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

GENERAL ELECTRICAL REQUIREMENTS

Electrical Grounding. Appendix C

Electrical Wiring Guide

Residential Electrical Inspection Checklist

Electrical Safety Tips. Help us keep you safe

Understanding Emergency Power Off (EPO)

GENERAL WIRING RULES FOR HOUSES

Top Commercial / Residential Electrical Requirements *

Electrical Contractors. and the. New Jersey. Rehabilitation Code

Residential Electrical Inspection. Checklist

Construction Electrical Terminology. Electricians

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Residential Electrical Inspection. Checklist

Title: Grounding and Bonding Rev-01

Electrical Code Regulation

Siemens STEP 2000 Course Basics of Electrical Products

Reverse-feed applications for circuit breakers

Residential Electrical System Aging Research Project. Dave Dini Sr. Research Engineer Underwriters Laboratories

12-Volt 10-Amp Regulated Power Supply

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Electrical Safety In and Around the Home

Stay Safe Around Electricity and Natural Gas Teacher s Guide

How to reduce exposure to arc flash hazards

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

Home Electrical Safety Challenge

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Extension Cord Safety Policy

Your Guide to. Electrical Safety

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

The Association of Electrical and Medical Imaging Equipment Manufacturers Arc Fault Circuit Interrupter

City of Riverside Building & Safety Division Residential Electric Vehicle (EV) Charger Guidelines

Parallel Circuits. Objectives After studying this chapter, you will be able to answer these questions: 1. How are electrical components connected

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

3053 Electrical Safety Training Program Course Outline

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Installation Instructions

Beware; the Multiwire Branch Circuit

How Much Voltage Drop Is Acceptable?

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

October Safety Subject

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

INSPECTION GUDELINES

Generator Transfer Switch Model # HTS15-AUTO

Laboratory Safety Guideline Electrical Safety

BRANCH CIRCUIT AND FEEDER REQUIREMENTS

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Notes. Material 1. Portable Ground Fault Interrupter 2. PPE (safety glasses, gloves, other) 3. Circuit Tester

Section B: Electricity

TSn SERIES Surge Protective Device

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

ELECTRICAL SAFETY RISK ASSESSMENT

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Electrical Hazards. Power Tools. Extension Cords

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

VLT Series 300 Watt True Sine Wave Inverter

HomeOwner Wiring. Please remember you are required to contact your inspector for inspections

VS CONTROL PACK INSTALLATION INSTRUCTIONS

Freedom SW Sine Wave Inverter/Chargers

Hot-Shot Operating Instructions

Single Phase Soft Starter

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO

Electrical Design TABLE OF CONTENTS FOREWORD BASIC ELEMENTS OF ELECTRICITY... 2 Electricity works much like water Ohm s Law

Bypass transfer switch mechanisms

Thermal Imaging for Home Inspectors

Grounding & Bonding Why it is done And How to Install Properly

INSTALLATION & SERVICE MANUAL. Display Panel

Best Methods for Safe Hipot Testing

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

ELECTRICAL INFORMATION

Transcription:

GE Industrial Solutions Residential Electronic Circuit Interrupters

Dual Function Circuit Interrupter (DFCI) Provides ground fault and arc fault circuit protection in one unit The 2014 National Electric Code has mandated Ground Fault and Arc Fault circuit protection on many 15 and 20 amp kitchen and laundry circuits. General Electric s Dual Function Circuit Interrupter (DFCI) offers both Ground Fault and Combination Arc Fault (GFCI and AFCI) protection in a simple to apply and cost-effective package. Dual function circuit interrupters utilize both GFCI and AFCI detection technology. GFCI protection guards against ground faults, and is an AFCI protection guards against damage or fires that can effective means of preventing electrical shocks. GFCI result from arcing and sparking. Arc Faults can arise from circuit breakers accomplish this by detecting when current deteriorated wires, poor connections and breaches in wire is leaking somewhere outside its intended path. If your insulation. With more than 67,000 home fires claiming more body provides the path to ground for this leakage you than 485 lives and injuring 2,300 victims annually, the added could be burned, shocked or even electrocuted. safety provided by AFCI protection is an important step forward in reducing this risk. Wiring diagram Bathroom 1 Bathroom 2 Kitchen Kitchen Refrigerator Dishwasher Range Clothes washer Laundry room Clothes dryer Unfinished basement Water heater Free Bedroom 1 Bedroom 2 Bedroom 3 Bedroom 4 Family room Dining room Finished basement Den Closets Hallways Sunroom Rec room HVAC Air handler DFCI AFCI Other device 2 Residential Electronic Circuit Interrupters

LED indicators Yellow 1 Yellow 2 Last known trip condition OFF OFF Overcurrent ON OFF Arc fault or PTT passed ON ON Arc fault to ground ON ON Ground fault Arc fault indicator (Yellow 1) Ground fault indicator (Yellow 2) Push to test Features The GE DFCI has important features for assisting you or your electrician in troubleshooting a trip. Should the DFCI trip, the yellow LED will blink to indicate the last known trip condition. Here is how it works: Turn the DFCI to the ON position. Observe LED indications and compare that to the chart at left. Last known trip condition LED indications will appear for 5 seconds each time the DFCI is turned on for up to 30 days. Note: Breaker must be energized to reset or turn on. Clearing the last known trip condition The DFCI has a self-test feature that meets a June 2015 requirement from UL on all ground fault circuit breakers. This self-test feature enables the DFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself in a lockout mode. Once in the lockout mode the breaker cannot be reset and must be replaced. This effortless system guarantees that only the best protection is provided at all times. Specifications Combination Arc Fault Circuit Interrupter Class A 5mA Ground Fault Circuit Interrupter 120VAC, 60 Hz Catalog Number Amps Poles Volt Plug-in THQL1115DF 15 THQL1120DF 20 1 120 Vac THHQL1115DF 15 THHQL1120DF 20 Interrupting Rating AIC 10k 22k Standard Pack Master Pack Plug-in 1 10 Wire Range #14-8 AWG UL Listed Arc Fault Circuit Interrupters No. 1699 UL Listed Ground Fault Circuit Interrupters No. 493 UL Listed Molded Case Circuit Breakers No. 489 3 Residential Electronic Circuit Interrupters

Combination Arc Fault Circuit Interrupter (AFCI) Provides arc fault protection Electrical fires in homes break out more then 67,000 times each year in the U.S. alone. Many result from arc faults. Arc faults are unintended electrical arcs that may ignite combustible materials in the home. Four types of arc faults may occur: line-to-line, line-to-ground, line-to-neutral, or a series arc fault, which is arcing over a gap within a single wire. Arc Faults may arise from a number of situations Damaged wires Shorted wires Wires pinched to grounded metal box Wires or cords in contact with vibrating metal Worn electrical insulation Overheated or stressed electrical cords and wires Corroded connections Misapplied/damaged appliances Loose electrical connections GE Combination AFCIs help protect against all types of arc faults An arc fault circuit interrupter (AFCI) detects arc faults and de-energizes the circuit before a fire can start. GE Combination AFCIs offer multiple kinds of protection. 1. Parallel protection Combination AFCIs can detect and interrupt parallel arc faults (line-to-line, line-to-ground, line-to-neutral, or a series arc fault). 2. Series Protection A series arc fault is the unintended flow of electricity over a gap within a single wire. These arc faults were not detectable until advanced technology allowed the development of the Combination AFCI breaker. 3. Overload protection. 4. Short circuit protection. These combination AFCIs electronically identify unique current and voltage characteristics of all arc faults and de-energize the entire circuit when one occurs. GE is one of the few companies to offer AFCI in a 1 inch standard breaker package freeing up valuable wire space. Fulfills 2008 National Electric Code (and later) requirements for all dwelling units. 2 position Push button test validates the arc detection capability of the breaker (Series and Parallel). Protects the entire circuit with an easy plug-in breaker design. Combination AFCIs are able to detect series and parallel arcs at a very low current level. Catalog Number Amps Pole Volt Interrupting Rating AIC Standard Pack THQL1115AF2 15 THQL1120AF2 20 THHQL1115AF2 15 THHQL1120AF2 20 1 120/240 1 Vac 1 Combination AFCI compliant with 2008 NEC and later 10k 22k 10 Combination AFCI detects both series and parallel arcs Trip indication window Push button test validates the arc detection capability of the breaker Specifications 1 pole 15A or 20A 10kAIC or 22kAIC 120/240 VAC Wire Range #14-8 AWG CU / #12-8 AWG AL UL listed Arc Fault Circuit Interrupters No. 1699 UL Listed Molded Case Circuit Breakers No. 489 4 Residential Electronic Circuit Interrupters

The GE AFCI Advantage Multi-wire circuits, shared neutrals, and mixed neutrals = No Problem! New construction applications Our competitors often use some form of Ground Fault measurement to aid in the detection of Arc Fault signatures. The only way for them to have a shared neutral solution is to create a two pole breaker with one neutral input shared by both poles of the breaker. Purchasing a 2 pole AFCI breaker that is specific to the shared application is generally quite a bit more expensive than two 1 pole breakers. Installers must inventory a completely different breaker catalog number and plan the number of shared neutrals runs. Installers must keep track of the neutrals as they would with a standard 1 pole installation. GE s simple solution uses (2) 1 pole breakers tied together with a handle tie. The handle tie is the only added expense quite small. You don t have to carry a separate catalog number just use two of the standard 1 pole breakers. GE s AFCI does not monitor the neutral at all. Only the pigtail on the breaker has to be connected to energize the breaker as with our competition. See DET-719 for additional information and wiring instructions Wiring diagram Tie handle bars together with THT104 Neutral lug of second AFCI can be left open Panel AFCI pigtails Neutral bar Retrofit applications Black conductor White conductor Red conductor 12/14-3 NM-B Note: for simplicity the ground wires are not shown Branch Circuit #1 (A-phase) Branch Circuit #2 (B-phase) 12/14-2 NM-B Junction box 12/14-2 NH-B GE sets itself apart in its ability to ignore mixed and shared neutrals commonly found in existing installations. The risk of having shared or non-isolated neutrals in retrofit situation is very high and will cause breakers that use a ground fault scheme in their AFCI detection to nuisance trip. Disadvantaged breakers that use a ground fault scheme in their AFCI detection: The circuit s neutral must come back to the specific breaker from which the hot leg originated. The neutral cannot be combined with other neutrals downstream. If the above conditions are not met the AFCI will trip as a result of its ground fault detection. All circuits with the above conditions must be cleaned up to achieve AFCI protection. The GE solution is a one pole AFCI breaker Period! Install the GE AFCI as you would any traditional circuit breaker. The GE AFCI does not need to monitor the neutral to provide full protection. The GE AFCI will not trip if the neutral for the protected circuit is combined downstream with neutrals of other circuits. The GE solution is the superior alternative when compared to receptacle options as well. The entire circuit is AFCI protected regardless of the length of the home run. Contractors and homeowners need not worry about: Accessibility issues either code driven or due to the location of the receptacles. Trip reset procedures are always conducted at the load center reducing callbacks when customers cannot figure out where to reset a trip device. 5 Residential Electronic Circuit Interrupters

Ground Fault Circuit Interrupter with Self-Test (GFCI) Provides ground fault protection The National Electrical Code requires GFCI protection of receptacles located outdoors, in bathrooms, garages and spa areas. This applies not only to new construction, but also to existing homes. When an electrical outlet is replaced in a location that requires ground-fault protection, the new outlet must be GFCI protected, according to the NEC. The GFCI circuit interrupter provides protection against overloads, short circuits and ground faults. It detects very low levels of electrical current leakage (ground faults), and acts quickly to shut off power, preventing serious shock. What is a Ground Fault? Normally, the electrical current traveling to an electrical appliance is identical to the current traveling from that appliance. However, an imbalance in that flow indicates a current leak also referred to as a ground fault, because the leaking current is escaping to the ground. If the leaking current is traveling through a person, that person could be injured, burned, severely shocked or electrocuted. For example, when a hair dryer is dropped into a sink full of water, some of the electrical current leaks out of the appliance and into the water. This current leak could be enough to kill someone who comes in contact with the water, but not be large enough to trip a non-ground fault circuit interrupter. (Standard circuit breakers only guard against over-loads and short circuits. They are not designed to protect people from electrical shocks.) 6 Residential Electronic Circuit Interrupters

Why GE Ground Fault Circuit Interrupters with Self-Test? Trip indicators Push button test validates the ground fault detection capability of the breaker Specifications Class A 5mA Ground Fault Circuit Interrupter 1 or 2 pole 15A, 20A, 25A, 30A, 40A, or 50A 10kAIC 120 Vac or 120/240 Vac Wire Range #14-8 AWG CU / #12-8 AWG AL UL listed Molded Case Circuit Breakers No. 489 Self-test functionality is a UL requirement on all GFCI devices commencing in June of 2015. This variant of the GFCI ensures its ground fault circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. When installed in a home s load center, the GE GFCI Self-Test does everything a circuit breaker does and it helps protect people against dangerous electrical shock caused by ground faults. Whenever it detects a ground fault, it almost instantaneously shuts off power, helping to prevent an electrical shock. Self-test functionality is a UL requirement commencing in June of 2015 on all GFCI devices. Catalog Number Amps Poles Volt Interrupting Rating AIC Standard Pack THQL1115GFT 15 THQL1120GFT 20 THQL1125GFT 25 THQL1130GFT 30 THQL2115GFT 15 THQL2120GFT 20 THQL2125GFT 25 THQL2130GFT 30 THQL2140GFT 40 1 1 120 Vac 10k 10 2 120/240 Vac 10k 10 THQL2150GFT 50 1 1 These units are UL and CSA rated 7 Residential Electronic Circuit Interrupters

Imagination at work GE 41 Woodford Avenue Plainville, CT 06062 www.geindustrial.com * Indicates a trademark of the General Electric Company and/or its subsidiaries. Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. DET-838B 0715