RFS Microwave Antennas A Comprehensive Selection Guide Edition The Clear Choice
Table of contents PAGE RFS offers a complete portfolio of microwave antennas to meet all of your needs PAGE TO 5 Compact antennas optimized for integrated applications (SB and SC) PAGE 6 TO 9 Antennas for long distances and high capacity applications (UA, DA, PAD) PAGE 0 TO 3 polarized antennas delivering ultra high performance and the highest XPD (UXA) PAGE 4 TO 7 Robust antennas for the harshest environments PAGE 8 Glossary PAGE 9 Mechanical, environmental and electrical testing PAGE 0 Understanding RFS model names PAGE Why RFS?
RFS offers a complete portfolio of microwave antennas to meet all of your needs RFS offers four types of microwave antennas, each one designed for a specific application in your network. Together, our complete portfolio of microwave antennas takes your network from rooftops in dense urban areas, through suburbs and across long stretches of land to the harshest mountaintop and seaside environments. Whether you are a telecom operator, a telecom manufacturer, a government agency, an enterprise or a strategic industry, RFS offers microwave antennas that support your applications and deliver dependable performance at low total cost of ownership (TCO): Stringent design and quality testing procedures ensure that every RFS microwave antenna meets or exceeds electrical, mechanical and environmental performance standards with no compromises and no surprises. Simplified installation and deployment procedures, low maintenance and longterm reliability keep postpurchase costs to a minimum. Compact packaging keeps transportation costs low. Modular designs let you pay as you grow, evolving antennas and adding capacity as needed without the cost of replacing the antenna. We also offer a full range of options and accessories for each antenna type to support your endtoend radio link network (RLN). With manufacturing facilities and teams around the world, RFS is ready to serve customers in any location. RFS offers four types of microwave antennas to meet all of your needs CompactLine and CompactLine Easy: Compact antennas optimized for integrated applications. TrunkLine: Large antennas for long distances and highcapacity applications. PrimeLine: polarized antennas delivering ultrahigh performance and the highest crosspolarization discrimination (XPD). Harsh Areas Line: Robust antennas that can withstand the harshest environmental conditions. Size ft (m) (0.3) (0.6) 3 (0.9) 4 (.) 6 (.8) 8 (.4) 0 (3.0) (3.7) 5 (4.6) Polarizations single dual single dual single dual single dual single dual single dual single dual single dual single dual Antennas (Prefix) Additional antenna variants and customized antenna versions are also available. They include: CompactLine (SB & SBX) TrunkLine Class 3 (UA & UDA) SB SBX SB SBX SB3 SBX3 SB4 SBX4 SB6 SBX6 UA8 UDA8 UA0 UDA0 UA UDA UA5 UDA5 CompactLine EASY (SC & SCX) TrunkLine Class (DA & DAX) SC SCX SC3 SCX3 DA6 DAX6 DA8 DAX8 DA0 DAX0 DA DAX DA5 DAX5 Trunkline FCC A (PAD & PADX ) PAD6 PADX6 PAD8 PADX8 PAD0 PADX0 PrimeLine (UXA) UXA UXA4 UXA6 UXA8 UXA0 UXA UXA5 Harsh Areas Line (SU & SUX, DA & DAX) SU SUX SU4 SUX4 SU6 SUX6 DA8 DAX8 DA0 DAX0 DA DAX Nonparabolic antennas, such as lens antennas that are available in some frequencies Antennas that support higher wind speeds Antennas that are not part of the RFS Harsh Areas Line but are customtreated with our harsh environment protective coatings Progressively phased out and replaced by new generation Available in North America only Antennas that are manufactured in our US facility and optimized for North American standards Antennas with different colors, flanges and mounting options such as those required for 9 mm pipe Please contact your RFS representative to discuss your specific requirements and identify the RFS antenna that best fits your needs.
RFS CompactLine (SB) & CompactLine EASY (SC) Compact antennas optimized for integrated applications Designed for: Dense urban areas, metropolitan and suburban locations, aggregation points Installed on: Rooftop poles or towers Featuring: Available in: Support for integrated radios to reduce costs, installation complexity and time Tested and validated ultrahigh (ETSI EN 30 7 Class 3, FCC Class A) electrical performance Lowprofile design to reduce transportation requirements, wind load and antenna weight Simplified mounting design to accelerate installation Hardcover radomes Support for winds up to 5 km/h (55 mph) Note: Antennas. m (4 ft) and larger support wind speeds up to 00 km/h (5 mph) by default but can be enhanced to support winds up to 5 km/h (55 mph) Supports for winds up to 30 km/h (98 mph) on the new SB/SBX antennas Note: SB/SBX revision C has been introduced in July 03 An optional sway bar for antennas 0.9 m (3 ft) and larger for added assurance in case mistakes are made during installation Frequencies ranging from 5.95 GHz to 5.6 GHz with support for three wideband frequency ranges (5.957.5, 7.58.5 and 0.7) to reduce antenna requirements and simplify logistics Sizes ranging from 0.3 m ( ft) to.8 m (6 ft) and dualpolarized models with the ability to upgrade from single to dual polarization and change frequencies in the field CompactLine EASY models, which are extra light and easy to transport, deploy and upgrade Please contact your RFS representative to verify which RFS CompactLine antenna models support these upgrades in the field. Integrated radios, compact design minimize TCO
Antenna models Frequency Range (GHz) Sizes (m) Sizes (ft) Model Name ( Polarized) Model Name ( Polarized) 5.957.5 0.9 3 SC3W60 SCX3W60. 4 SB4W60 SBX4W60.8 6 SB6W60 SBX6W60 7.58.5 0.6 SCW7 SCXW7 0.9 3 SC3W7 SCX3W7. 4 SB4W7 SBX4W7.8 6 SB6W7 SBX6W7 0.7 0.6 SCW00 SCXW00 0.9 3 SC3W00 SCX3W00. 4 SB4W00 SBX4W00.8 6 SB6W00 SBX6W00.73.5 0.3 SB7 SBX7 0.6 SC7 SCX7 0.9 3 SC37 SCX37. 4 SB47 SBX47.8 6 SB67 SBX67 4.5.35 0.3 SB4 SBX4 0.6 SC4 SCX4 0.9 3 SC34 SCX34. 4 SB44 SBX44.8 6 SB64 SBX64 7.79.7 0.3 SB90 SBX90 0.6 SC90 SCX90 0.9 3 SC390 SCX390. 4 SB490 SBX490.8 6 SB690 SBX690.3.6 0.3 SB0 SBX0 0.6 SC0 SCX0 0.9 3 SC30 SCX30. 4 SB40 SBX40.8 6 SB60 SBX60 4.56.5 0.3 SB50 SBX50 0.6 SC50 SCX50 0.9 3 SC350 SCX350. 4 SB450 SBX450 7.59.5 0.3 SB80 SBX80 0.6 SC80 SCX80 333.4 0.3 SB30 SBX30 0.6 SC30 SCX30 3740 0.3 SB380 SBX380 0.6 SC380 SCX380 40.543.5 0.3 SB40 SBX40 0.6 SC40 SCX40 5.5.6 0.3 SB50 NA Wideband model Planned for Q4 This table summarizes the main RFS CompactLine (SB) and CompactLine EASY (SC) antenna models. Additional antenna variants and customized versions are also available. For example, variants that support specific vendor s radios are available. To confirm proper ordering models, please contact your RFS representative. 3
RFS COMPACTLINE (SB) AND COMPACTLINE EASY (SC) 4 Performance specifications Visit our online ecatalog dataxpress for the latest and most complete data specifications: www.rfsworld.com/dataxpress Frequency (GHz) 5.95 to 7.5 7.5 to 8.5 0 to.7.7 to 3.5 4. to 5.35 7.7 to 9.7. to 3.6 4.5 to 6.5 Polarization Model Number Note: The specifications for the SB/SBX (revision C) and SC/SCX (revision B) reflect the new generation introduced in July 03. Diameter Gain (dbi) ETSI 3 dbbw VSWR/R L XPol IPI F/B US FCC Fine Adjust. Windspeed km/h (mph) Net weight RPE m (ft) Low Mid High (deg) (db) (db) (db) (db) 0 Cat class Az Elev Operational Survival kg (lb) SC3W60 3 0.9 (3) 3.0 33. 33.9 3.00.38 (6.0) 30 60 3 B ±5 ±5 80 () 5 (55) (47) SB4W60. (4) 34.5 34.8 35.5.8.30 (7.7) 30 6 3 B ±5 ±5 00 (5) 00 (5) 35 (77) SB6W60.8 (6) 38.0 38.8 39.4.7.30 (7.7) 30 65 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SCX3W60 3 0.9 (3) 3.0 33. 33.9 3.00.38 (6.0) 30 35 60 3 B ±5 ±5 80 () 5 (55) (47) SBX4W60. (4) 34.5 34.8 35.5.8.30 (7.7) 30 35 6 3 B ±5 ±5 00 (5) 00 (5) 35 (77) SBX6W60.8 (6) 38.0 38.8 39.4.7.30 (7.7) 30 35 65 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SCW7 0.6 () 30.5 3.3 3.9 4.3.38 (6.0) 30 57 3 ±5 ±0 80 () 5 (55) 9 (0) SC3W7 0.9 (3) 34.7 35.6 35.8.6.38 (6.0) 30 6 3 ±5 ±5 80 () 5 (55) 8 (40) SB4W7. (4) 36. 36.9 37.6.3.30 (7.7) 30 63 3 ±5 ±5 00 (5) 00 (5) 35 (77) SB6W7.8 (6) 40. 40.6 4..5.30 (7.7) 30 67 3 ±5 ±5 00 (5) 00 (5) 90 (98) SCXW7 0.6 () 30.5 3.3 3.9 4.3.38 (6.0) 30 35 57 3 ±5 ±0 80 () 5 (55) 9 (0) SCX3W7 0.9 (3) 34.7 35.6 35.8.6.38 (6.0) 30 35 6 3 ±5 ±5 80 () 5 (55) 8 (40) SBX4W7. (4) 36. 36.9 37.6.3.30 (7.7) 30 35 63 3 ±5 ±5 00 (5) 00 (5) 35 (77) SBX6W7.8 (6) 40. 40.6 4..5.30 (7.7) 30 35 67 3 ±5 ±5 00 (5) 00 (5) 90 (98) SCW00 0.6 () 33.8 34.5 35. 3..38 (6.0) 30 6 3 A/B ±5 ±0 80 () 5 (55) 9 (0) SC3W00 0.9 (3) 37.6 38.3 39..0.38 (6.0) 30 64 3 A ±5 ±5 80 () 5 (55) 8 (40) SB4W00. (4) 39.4 39.9 40.3.5.30 (7.7) 30 66 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SB6W00.8 (6) 4.7 43.4 43.9.0.30 (7.7) 30 70 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SCXW00 0.6 () 33.8 34.5 35. 3..38 (6.0) 30 35 6 3 A/B ±5 ±0 80 () 5 (55) 9 (0) SCX3W00 0.9 (3) 37.6 38.3 39..0.38 (6.0) 30 35 64 3 A ±5 ±5 80 () 5 (55) 8 (40) SBX4W00. (4) 39.4 39.9 40.3.5.30 (7.7) 30 35 66 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SBX6W00.8 (6) 4.7 43.4 43.9.0.30 (7.7) 30 35 70 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SB7 0.3 () 3. 3.5 3.8 4.5.38 (6.0) 30 57 3 ±5 ±0 5 (55) 30 (98) 6 (3) SC7 0.6 () 35.8 36.0 36..7.38 (6.0) 30 6 3 ±5 ±0 80 () 5 (55) 9 (0) SC37 0.9 (3) 39.9 40.0 40..6.38 (6.0) 30 66 3 A ±5 ±5 80 () 5 (55) 8 (40) SB47. (4) 4.7 4.9 4..3.30 (7.7) 30 68 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SB67.8 (6) 45. 45.4 45.7 0.9.30 (7.7) 30 7 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SBX7 0.3 () 3. 3.5 3.8 4.5.38 (6.0) 30 35 57 3 ±5 ±0 5 (55) 30 (98) 6 (3) SCX7 0.6 () 35.8 36.0 36..7.38 (6.0) 30 35 6 3 ±5 ±0 80 () 5 (55) 9 (0) SCX37 0.9 (3) 39.9 40.0 40..6.38 (6.0) 30 35 66 3 A ±5 ±5 80 () 5 (55) 8 (40) SBX47. (4) 4.7 4.9 4..3.30 (7.7) 30 35 68 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SBX67.8 (6) 45. 45.4 45.7 0.9.30 (7.7) 30 35 7 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SB4 0.3 () 3.0 3. 3. 4..30 (7.7) 30 55 ±5 ±0 5 (55) 30 (98) 6 (3) SC4 0.6 () 36.7 37. 37.3.3.38 (6.0) 30 65 3 ±5 ±0 80 () 5 (55) 9 (0) SC34 0.9 (3) 40.6 4.0 4.3.5.38 (6.0) 30 69 3 ±5 ±5 80 () 5 (55) 8 (40) SB44. (4) 4.7 4.9 43...30 (7.7) 30 7 3 ±5 ±5 00 (5) 00 (5) 35 (77) SB64.8 (6) 45.9 46. 46.5 0.8.30 (7.7) 30 74 3 ±5 ±5 00 (5) 00 (5) 90 (98) SBX4 0.3 () 3.0 3. 3. 4..30 (7.7) 30 35 55 ±5 ±0 5 (55) 30 (98) 6 (3) SCX4 0.6 () 36.7 37. 37.3.3.38 (6.0) 30 35 65 3 ±5 ±0 80 () 5 (55) 9 (0) SCX34 0.9 (3) 40.6 4.0 4.3.5.38 (6.0) 30 35 69 3 ±5 ±5 80 () 5 (55) 8 (40) SBX44. (4) 4.7 4.9 43...30 (7.7) 30 35 7 3 ±5 ±5 00 (5) 00 (5) 35 (77) SBX64.8 (6) 45.9 46. 46.5 0.8.30 (7.7) 30 35 74 3 ±5 ±5 00 (5) 00 (5) 90 (98) SB90 0.3 () 33.8 34. 35. 3.4.30 (7.7) 30 56 B ±5 ±0 5 (55) 30 (98) 6 (3) SC90 0.6 () 38.5 39.0 39.5.8.38 (6.0) 30 68 3 A ±5 ±0 80 () 5 (55) 9 (0) SC390 0.9 (3) 4.8 43.3 43.8..38 (6.0) 30 7 3 A ±5 ±5 64 (0) 5 (55) 8 (40) SB490. (4) 44. 44.7 45..0.30 (7.7) 30 7 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SB690.8 (6) 47.6 48. 48.8 0.7.30 (7.7) 30 76 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SBX90 0.3 () 33.8 34. 35. 3.4.30 (7.7) 30 35 56 B ±5 ±0 5 (55) 30 (98) 6 (3) SCX90 0.6 () 38.5 39.0 39.5.8.38 (6.0) 30 35 68 3 A ±5 ±0 80 () 5 (55) 9 (0) SCX390 0.9 (3) 4.8 43.3 43.8..38 (6.0) 30 35 7 3 A ±5 ±5 64 (0) 5 (55) 8 (40) SBX490. (4) 44. 44.7 45..0.30 (7.7) 30 35 7 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SBX690.8 (6) 47.6 48. 48.8 0.7.30 (7.7) 30 35 76 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SB0 0.3 () 35.5 35.8 36..7.30 (7.7) 30 6 3 A ±5 ±0 5 (55) 30 (98) 6 (3) SC0 0.6 () 40.5 4.0 4.5.5.9 (8.0) 30 66 3 A ±5 ±0 80 () 5 (55) 9 (0) SC30 0.9 (3) 44. 44.8 45.0.0.9 (8.0) 30 7 3 A ±5 ±5 40 (87) 5 (55) 8 (40) SB40. (4) 45.5 46. 46.6 0.8.30 (7.7) 30 74 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SB60.8 (6) 49.3 50.0 50.5 0.5.30 (7.7) 30 75 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SBX0 0.3 () 35.5 35.8 36..7.30 (7.7) 30 35 6 3 A ±5 ±0 5 (55) 30 (98) 6 (3) SCX0 0.6 () 40.5 4.0 4.5.5.9 (8.0) 30 35 66 3 A ±5 ±0 80 () 5 (55) 9 (0) SCX30 0.9 (3) 44. 44.8 45.0.0.9 (8.0) 30 35 7 3 A ±5 ±5 40 (87) 5 (55) 8 (40) SBX40. (4) 45.5 46. 46.6 0.8.30 (7.7) 30 35 74 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SBX60.8 (6) 49.3 50.0 50.5 0.5.30 (7.7) 30 35 75 3 A ±5 ±5 00 (5) 00 (5) 90 (98) SB50 0.3 () 36.3 36.6 37.0.4.30 (7.7) 30 6 3 ±5 ±0 5 (55) 30 (98) 6 (3) SC50 0.6 () 4.7 4.3 4.5.4.9 (8.0) 30 68 3 A ±5 ±0 80 () 5 (55) 9 (0) SC350 0.9 (3) 45.6 46. 46.5 0.8.9 (8.0) 30 73 3 A ±5 ±5 40 (87) 5 (55) 8 (40) SB450. (4) 46.8 47. 47.6 0.7.30 (7.7) 30 73 3 A ±5 ±5 00 (5) 00 (5) 35 (77) SBX50 0.3 () 36.3 36.6 37.0.4.30 (7.7) 30 35 6 3 ±5 ±0 5 (55) 30 (98) 6 (3) SCX50 0.6 () 4.7 4.3 4.5.4.9 (8.0) 30 35 68 3 A ±5 ±0 80 () 5 (55) 9 (0) SCX350 0.9 (3) 45.6 46. 46.5 0.8.9 (8.0) 30 35 73 3 A ±5 ±5 40 (87) 5 (55) 8 (40) SBX450. (4) 46.8 47. 47.6 0.7.30 (7.7) 30 35 73 3 A ±5 ±5 00 (5) 00 (5) 35 (77)
Performance specifications Frequency (GHz) Polarization Model Number Gain (dbi) ETSI Fine Adjust. Windspeed km/h (mph) Diameter 3 dbbw VSWR/R L XPol IPI F/B US FCC Net weight RPE m (ft) (deg) (db) (db) (db) 0 Cat Low Mid High (db) class Az Elev Operational Survival kg (lb) SB80 0.3 () 37.7 37.9 38.5..30 (7.7) 30 63 3 ±5 ±0 5 (55) 30 (98) 6 (3) SC80 0.6 () 4.7 43.0 43.4..9 (8.0) 30 70 3 ±5 ±0 80 () 5 (55) 9 (0) 7.5 to 9.5 SBX80 0.3 () 37.7 37.9 38.5..30 (7.7) 30 35 63 3 ±5 ±0 5 (55) 30 (98) 6 (3) SCX80 0.6 () 4.7 43.0 43.4..9 (8.0) 30 35 70 3 ±5 ±0 80 () 5 (55) 9 (0) SB30 0.3 () 39. 39.5 39.7..30 (7.7) 30 63 3b ±5 ±0 5 (55) 30 (98) 6 (3) SC30 0.6 () 43.8 44. 44.4.0.9 (8.0) 30 70 3b ±5 ±0 64 (0) 5 (55) 9 (0) 3 to 33.4 SBX30 0.3 () 39. 39.5 39.7..30 (7.7) 30 35 63 3b ±5 ±0 5 (55) 30 (98) 6 (3) SCX30 0.6 () 43.8 44. 44.4.0.9 (8.0) 30 35 70 3b ±5 ±0 64 (0) 5 (55) 9 (0) SB380 0.3 () 40.0 40.3 40.5.6.30 (7.7) 30 65 3b A ±5 ±0 5 (55) 30 (98) 6 (3) SC380 0.6 () 44.8 45.4 45.8 0.8.9 (8.0) 30 70 3b A ±5 ±0 40 (87) 5 (55) 9 (0) 37 to 40 SBX380 0.3 () 40.0 40.3 40.5.6.30 (7.7) 30 35 65 3b A ±5 ±0 5 (55) 30 (98) 6 (3) SCX380 0.6 () 44.8 45.4 45.8 0.8.9 (8.0) 30 35 70 3b A ±5 ±0 40 (87) 5 (55) 9 (0) SB40 0.3 () 40.8 4.3 4.6.4.30 (7.7) 30 60 3b ±5 ±0 5 (55) 30 (98) 6 (3) SC40 0.6 () 45.5 45.8 46. 0.7.9 (8.0) 30 65 3b ±5 ±0 40 (87) 5 (55) 9 (0) 40.5 to 43.5 SBX40 3 0.3 () 40.8 4.3 4.6.4.30 (7.7) 30 30 60 3b ±5 ±0 5 (55) 30 (98) 6 (3) SCX40 3 0.6 () 45.5 45.8 46. 0.7.9 (8.0) 30 30 65 3b ±5 ±0 40 (87) 5 (55) 9 (0) 5. to 5.6 SB50 0.3 () 4.7 4.8 4.9..30 (7.7) 30 6 3a / ±3 ±30 40 (87 5 (55) 6 (3) A in 0.550.68 GHz, B in 0.7.7 GHz 3a in Vertical polar, in Vertical and Horizontal polar 3 Planned for Q4 The windspeed performance specifications of 4 and 6 feet in this table apply to antennas categorized under Configuration in the associated wind speed and sway bar selection guide. All Configuration antennas with a survival wind speed of 00 km/h are also available in models that offer higher survival wind speed performance ( Configuration ). Wind speed and sway bar selection guide A wind kit, perimeter sway bar and sway bar connecting kit are available to complement your RFS CompactLine and CompactLine EASY antennas: A wind kit increases antenna survival wind speed support from 00 km/h (5 mph) to 5 km/h (55 mph). Wind kits give customers the flexibility to upgrade survival wind speed support levels in the field during installation if wind conditions are more severe than anticipated. Note that: The wind kit is available for. m (4 ft) antennas 0.3 m ( ft) have a survival wind speed of 30 km/h (98 mph) 0.6 m ( ft) and 0.9 m (3 ft) antennas have a survival wind speed of 5 km/h (55 mph).8 m (6 ft) antennas are available in either in 00 km/h (5 mph) or 5 km/h (55 mph) versions and cannot be upgraded in the field An optional perimeter sway bar provides added assurance on antennas that are 0.9 m (3 ft) and larger in case mistakes are made during installation. A universal sway bar tower connecting kit allows sway bars to be attached to pipes or Lstructures without drilling a hole in the pipe or structure. Sizes (ft) 3 4 6 Model (Prefix) SB/SBX SC/SCX SC/SCX SB/SBX SB/SBX Wind Speed (km/h) 30 5 5 Configuration Configuration Configuration Configuration 00 5* 00 5* Sway Bar Qty 0 0 0 SMAWK4A 5 km/h Windkit Not Available** Additional Perimeter Sway Bar Sway Bar Tower Fixation Kit Not Available Not Available SMASK3 SMASK4 SMASK6 SMASKOUNIVERSAL SMASKOUNIVERSALL * Order as a unique model number. For example: SB67AB is the standard 00 km/h (5 mph) version; SB67AB is the 5 km/h (55 mph) version. See page 0 for details. ** It is not possible to upgrade in field a SB6/SBX6 antenna from 00km/h to 5km/h. 5
RFS TrunkLine Class 3 (UA & UDA), Class (DA & DAX) & FCC A (PAD & PADX) For long distances and highcapacity applications Designed for: Microwave backbone networks, long distances, highcapacity links Installed on: Towers Featuring : Fieldproven reliability and long life A choice between tested and validated ultrahigh (ETSI EN 30 7 Class 3 and FCC Class A) electrical performance or high (ETSI Class and FCC Class B) performance Support for winds up to 00 km/h (5 mph) with highwind versions that support winds up to 5 km/h (55 mph) and an optional sway bar for added assurance in case mistakes are made during installation A singlepiece or a splitreflector configuration and compact packaging to reduce transportation costs A full line of waveguides, options and accessories 6 Available in: Frequencies ranging from 3.6 GHz to 5.35 GHz with support for two wideband frequency ranges (5.756.875 and 7.58.5) to reduce antenna requirements and simplify logistics Sizes ranging from. m (4 ft) to 4.6 m (5 ft) and dualpolarized models with the ability to upgrade from single to dual polarization and change frequencies in the field in most cases 3 North Americaonly antennas (PAD and PADX models) feature: Improved performance that meets Federal Communications Commission (FCC) category A standards without a shroud Good radiation performance, particularly in the back end An efficient feed design and a deepdish reflector to improve fronttoback ratio Support for an ultrawideband frequency range (5.757.5) and two wideband frequency ranges (5.756.875 and 5.956.875) Antenna sizes ranging from.8 m (6 ft) to 3 m (0 ft) and dualpolarized models with the ability to upgrade from single to dual polarization and change frequencies in the field in most cases 3 RFS TrunkLine antennas go the distance RFS TrunkLine antennas are proven around the world: In Russia, a microwave backbone network based on RFS TrunkLine antennas provides cellular coverage along the main road and train arteries between Moscow and St. Petersburg In Arizona, USA, RFS TrunkLine antennas, waveguides and accessories provide the lifeline for the state s highway patrol, Emergency Medical Services (EMS) providers and other public safety services operating across long distances. These features and model ranges apply to RFS TrunkLine DA, DAX, UA and UDA antenna models. Features and models for RFS TrunkLine PAD and PADX antennas are described separately. The splitreflector configuration is available on antennas.4 m (8 ft) and larger. piece is the default configuration for antennas.4 m (8 ft) and 3 m (0 ft). Splitreflector is the default configuration for antennas 3.7 m ( ft) and 4.6 m (5 ft) 3 Please contact your RFS representative to verify which RFS TrunkLine antenna models support these upgrades in the field.
Antenna models Frequency Range (GHz) 3.64. 4.45 5.756.875 5.757.5 5.956.45 5.956.875 6.457.5 7.58.5 0.30.7 0.7.7 Sizes (m) Sizes (ft) Model Name ( Polarized High performance) Model Name ( Polarized UltraHigh performance) Model Name ( Polarized High performance) Model Name ( Polarized UltraHigh performance).8 6 DA636 DAX636.4 8 DA836 DAX836 3 0 DA036 DAX036 3.7 DA36 DAX36 4.6 5 DA536 DAX536. 4 DA444 DAX444.8 6 DA644 DAX644.4 8 DA844 DAX844 3 0 DA044 DAX044 3.7 DA44 DAX44 4.6 5 DA544 DAX544.8 6 PAD6W57,, 3.4 8 3 0 DA8W57, PAD8W57,, 3 DA0W57, PAD0W57,, 3 PADX8W57,, 3 PADX0W57,, 3.8 6 PADX6U57, 3.4 8 PADX8U57, 3 3 0 PADX0U57, 3.8 6 PAD659, 3 UA659.4 8 3 0 DA859 PAD859, 3 DA059 PAD059, 3 UA859 UA059 DAX859 DAX059 3.7 DA59 UA59 DAX59 4.6 5 DA559 DAX559.8 6 PADX6W59.4 8 PADX8W59,, 3 3 0 PADX0W59,, 3.8 6 PAD665, 3 UA665.4 8 DA865 PAD865, 3 DA065 PAD065, 3 UA865 UA065 DAX865 DAX065 3 0 3.7 DA65 UA65 DAX65 4.6 5 DA565 DAX565.4 8 DA8W7 UA8W7 DAX8W7 UDA8W7 3 0 DA0W7 UA0W7 DAX0W7 UDA0W7 3.7 DAW7 UAW7 DAXW7 UDAW7 4.6 5 DA5W7 UA5W7 DAX5W7 UDA5W7.4 8 DA803 DAX803 3 0 DA003 DAX003 3.7 DA03 DAX03.8 6 PAD607, 3 PADX607, 3.4 8 3 0 DA807 PAD807, 3 DA007 DAX807 PADX807, 3 DAX007 PADX007, 3 3.7 DA07 DAX07.4 8 DA87 UA87 DAX87.73.5 3 0 DA07 UA07 DAX07 4.5.35.4 8 DA84 UA84 DAX84 3 Wideband model Available only in North America PAD and PADX antenna models offer improved performance This table summarizes the main RFS TrunkLine antenna models. Additional antenna variants and customized versions are also available. To confirm proper ordering models, please contact your RFS representative. 7
RFS TRUNKLINE CLASS 3 (UA & UDA), TRUNKLINE CLASS (DA & DAX) AND TRUNKLINE FCC A (PAD & PADX) Performance specifications UA & UDA, DA & DAX Visit our online ecatalog dataxpress for the latest and most complete data specifications: www.rfsworld.com/dataxpress 8 Frequency (GHz) 3.6 to 4. 4.4 to 5 5.75 to 6.875 5.95 to 6.45 6.45 to 7.5 7.5 to 8.5 0.3 to 0.7 Polarization Model Number Diameter Gain (dbi) ETSI 3 dbbw VSWR/R L XPol IPI F/B US FCC Fine Adjust. Windspeed km/h (mph) RPE Net weight m (ft) Low Mid High (deg) (db) (db) (db) (db) 0 Cat class Az Elev Operational Survival kg (lb) DA636.8 (6) 33.7 34.4 35 3.0.08 (8.3) 30 56 ±5 ±5 90 (8) 00 (5) 95 (09) DA836.4 (8) 36.5 37. 37.8.3.06 (30.7) 30 60 ±5 ±5 90 (8) 00 (5) 80 (396) DA036 3 (0) 38.4 39. 39.7.8.06 (30.7) 30 6 ±5 ±5 90 (8) 00 (5) 90 (638) DA36 3.7 () 40.0 40.7 4.3.5.06 (30.7) 30 63 B ±5 ±5 90 (8) 00 (5) 40 (94) DA536 4.6 (5) 4.0 4.7 43.3..06 (30.7) 30 65 A ±5 ±5 90 (8) 00 (5) 750 (650) DAX636.8 (6) 33.7 34.4 35 3.0.08 (8.3) 30 35 56 ±5 ±5 90 (8) 00 (5) 95 (09) DAX836.4 (8) 36.5 37. 37.8.3.06 (30.7) 30 35 60 ±5 ±5 90 (8) 00 (5) 80 (396) DAX036 3 (0) 38.4 39. 39.7.8.06 (30.7) 30 35 6 ±5 ±5 90 (8) 00 (5) 90 (638) DAX36 3.7 () 40.0 40.7 4.3.5.06 (30.7) 30 35 63 B ±5 ±5 90 (8) 00 (5) 40 (94) DAX536 4.6 (5) 4.0 4.7 43.3..06 (30.7) 30 35 65 A ±5 ±5 90 (8) 00 (5) 750 (650) DA444. (4) 3 3.5 33 3.7.0 (6.4) 8 5 ±5 ±5 90 (8) 00 (5) 45 (99) DA644.8 (6) 35.9 36.5 37.4.06 (30.7) 30 6 ±5 ±5 90 (8) 00 (5) 95 (09) DA844.4 (8) 38.5 39. 39.6.8.06 (30.7) 30 65 ±5 ±5 90 (8) 00 (5) 80 (396) DA044 3 (0) 40.4 4 4.5.5.06 (30.7) 30 67 ±5 ±5 90 (8) 00 (5) 90 (638) DA44 3.7 () 4 4.6 43...06 (30.7) 30 68 ±5 ±5 90 (8) 00 (5) 40 (94) DA544 4.6 (5) 43.7 44.3 44.8 0.9.06 (30.7) 30 68 ±5 ±5 90 (8) 00 (5) 750 (650) DAX444. (4) 3 3.5 33 3.7.5 (3.) 30 35 54 ±5 ±5 90 (8) 00 (5) 45 (99) DAX644.8 (6) 35.6 36. 36.7.4.06 (30.7) 30 35 60 ±5 ±5 90 (8) 00 (5) 95 (09) DAX844.4 (8) 38. 38.8 39.6.8.06 (30.7) 30 35 64 ±5 ±5 90 (8) 00 (5) 80 (396) DAX044 3 (0) 40. 40.7 4..5.06 (30.7) 30 35 66 ±5 ±5 90 (8) 00 (5) 90 (638) DAX44 3.7 () 4.7 4.3 4.8..06 (30.7) 30 35 67 ±5 ±5 90 (8) 00 (5) 40 (94) DAX544 4.6 (5) 43.7 44.3 44.8 0.9.06 (30.7) 30 35 67 ±5 ±5 90 (8) 00 (5) 750 (650) DA8W57.4 (8) 40.7 4.5 4.3.4.5 (3.) 30 68 A ±5 ±5 90 (8) 00 (5) 80 (396) DA0W57 3 (0) 4.6 43.5 44...5 (3.) 30 70 A ±5 ±5 90 (8) 00 (5) 90 (638) UA659.8 (6) 38.5 39 39.3.9.06 (30.7) 30 64 3 A ±5 ±5 90 (8) 00 (5) 95 (09) DA859.4 (8) 4. 4.6 4.5.06 (30.7) 30 66 A ±5 ±5 90 (8) 00 (5) 80 (396) UA859.4 (8) 4. 4.6 4.5.06 (30.7) 30 70 3 A ±5 ±5 90 (8) 00 (5) 80 (396) DA059 3 (0) 43 43.4 43.7..06 (30.7) 30 69 A ±5 ±5 90 (8) 00 (5) 90 (638) UA059 3 (0) 43 43.4 43.7..06 (30.7) 30 7 3 A ±5 ±5 90 (8) 00 (5) 90 (638) DA59 3.7 () 44.8 45. 45.4 0.9.06 (30.7) 30 70 A ±5 ±5 90 (8) 00 (5) 40 (94) UA59 3.7 () 44.8 45. 45.4 0.9.06 (30.7) 30 74 3 A ±5 ±5 90 (8) 00 (5) 40 (94) DA559 4.6 (5) 46.3 46.6 47 0.8.06 (30.7) 30 7 A ±5 ±5 90 (8) 00 (5) 750 (650) DAX859.4 (8) 40.9 4.3 4.7.5.06 (30.7) 30 35 66 A ±5 ±5 90 (8) 00 (5) 80 (396) DAX059 3 (0) 4.9 43. 43.5..06 (30.7) 30 35 69 A ±5 ±5 90 (8) 00 (5) 90 (638) DAX59 3.7 () 44.6 44.8 45. 0.9.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 00 (5) 40 (94) DAX559 4.6 (5) 46.3 46.6 47 0.8.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 00 (5) 750 (650) UA665.8 (6) 39.4 39.8 40..7.06 (30.7) 30 67 3 A ±5 ±5 90 (8) 00 (5) 95 (09) DA865.4 (8) 4.9 4.3 4.8.3.06 (30.7) 30 66 A ±5 ±5 90 (8) 00 (5) 80 (396) UA865.4 (8) 4.9 4.3 4.8.3.06 (30.7) 30 70 3 A ±5 ±5 90 (8) 00 (5) 80 (396) DA065 3 (0) 43.7 44. 44.6.0.06 (30.7) 30 69 A ±5 ±5 90 (8) 00 (5) 90 (638) UA065 3 (0) 43.7 44. 44.6.0.06 (30.7) 30 7 3 A ±5 ±5 90 (8) 00 (5) 90 (638) DA65 3.7 () 45.3 45.8 46. 0.8.06 (30.7) 30 70 A ±5 ±5 90 (8) 00 (5) 40 (94) UA65 3.7 () 45.3 45.8 46. 0.8.06 (30.7) 30 74 3 A ±5 ±5 90 (8) 00 (5) 40 (94) DA565 4.6 (5) 47 47.5 47.9 0.7.06 (30.7) 30 7 A ±5 ±5 90 (8) 00 (5) 750 (650) DAX865.4 (8) 4.8 4. 4.7.3.06 (30.7) 30 35 68 A ±5 ±5 90 (8) 00 (5) 80 (396) DAX065 3 (0) 43.5 43.9 44.4.0.06 (30.7) 30 35 70 A ±5 ±5 90 (8) 00 (5) 90 (638) DAX65 3.7 () 45. 45.6 46.0 0.8.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 00 (5) 40 (94) DAX565 4.6 (5) 47 47.5 47.9 0.7.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 00 (5) 750 (650) DA8W7.4 (8) 4.6 43.3 44...0 (6.4) 30 68 ±5 ±5 90 (8) 00 (5) 80 (396) UA8W7.4 (8) 4.6 43.3 44...0 (6.4) 30 7 3 ±5 ±5 90 (8) 00 (5) 80 (396) DA0W7 3 (0) 44.6 45.3 46. 0.9.0 (6.4) 30 70 ±5 ±5 90 (8) 00 (5) 90 (638) UA0W7 3 (0) 44.6 45.3 46. 0.9.0 (6.4) 30 73 3 ±5 ±5 90 (8) 00 (5) 90 (638) DAW7 3.7 () 46. 47 47.7 0.7.0 (6.4) 30 7 ±5 ±5 90 (8) 00 (5) 40 (94) UAW7 3.7 () 46. 47 47.7 0.7.0 (6.4) 30 74 3 ±5 ±5 90 (8) 00 (5) 40 (94) DA5W7 4.6 (5) 47.9 48.7 49.4 0.6.0 (6.4) 30 7 ±5 ±5 90 (8) 00 (5) 750 (650) DAX8W7.4 (8) 4.4 43. 43.9..0 (6.4) 30 35 68 ±5 ±5 90 (8) 00 (5) 80 (396) UDA8W7.4 (8) 4.4 43. 43.9..0 (6.4) 30 35 7 3 ±5 ±5 90 (8) 00 (5) 80 (396) DAX0W7 3 (0) 44.4 45. 45.9 0.9.0 (6.4) 30 35 70 ±5 ±5 90 (8) 00 (5) 90 (638) UDA0W7 3 (0) 44.4 45. 45.9 0.9.0 (6.4) 30 35 73 3 ±5 ±5 90 (8) 00 (5) 90 (638) DAXW7 3.7 () 46.0 46.7 47.5 0.7.0 (6.4) 30 35 7 ±5 ±5 90 (8) 00 (5) 40 (94) UDAW7 3.7 () 46.0 46.7 47.5 0.7.0 (6.4) 30 35 74 3 ±5 ±5 90 (8) 00 (5) 40 (94) DAX5W7 4.6 (5) 47.7 48.6 49.4 0.6.0 (6.4) 30 35 7 ±5 ±5 90 (8) 00 (5) 750 (650) UDA5W7 4.6 (5) 47.7 48. 48.4 0.6.0 (6.4) 30 35 76 3 ±5 ±5 90 (8) 00 (5) 750 (650) DA803.4 (8) 45.7 45.9 46 0.8.08 (8.3) 30 68 A ±5 ±5 90 (8) 00 (5) 80 (396) DA003 3 (0) 47.6 47.8 47.9 0.7.08 (8.3) 30 70 A ±5 ±5 90 (8) 00 (5) 90 (638) DA03 3.7 () 49 49. 49.3 0.5.08 (8.3) 30 7 A ±5 ±5 90 (8) 00 (5) 40 (94) DAX803.4 (8) 45.6 45.8 45.9 0.8.08 (8.3) 30 35 68 A ±5 ±5 90 (8) 00 (5) 80 (396) DAX003 3 (0) 47.5 47.7 47.8 0.7.08 (8.3) 30 35 70 A ±5 ±5 90 (8) 00 (5) 90 (638) DAX03 3.7 () 48.9 49. 49. 0.5.08 (8.3) 30 35 7 A ±5 ±5 90 (8) 00 (5) 40 (94)
Frequency (GHz) 0.7 to.7.7 to 3.5 4. to 5.35 Polarization Model Number Diameter Gain (dbi) ETSI 3 dbbw VSWR/R L XPol IPI F/B US FCC Fine Adjust. Windspeed km/h (mph) RPE Net weight m (ft) Low Mid High (deg) (db) (db) (db) (db) 0 Cat class Az Elev Operational Survival kg (lb) DA807.4 (8) 46. 46.4 46.9 0.8.06 (30.7) 30 7 A ±5 ±5 90 (8) 00 (5) 80 (396) DA007 3 (0) 48 48.4 48.6 0.7.06 (30.7) 30 7 A ±5 ±5 90 (8) 00 (5) 90 (638) DA07 3.7 () 49.4 49.8 50 0.5.06 (30.7) 30 7 A ±5 ±5 90 (8) 00 (5) 40 (94) DAX807.4 (8) 45.9 46. 46.7 0.8.06 (30.7) 30 35 69 A ±5 ±5 90 (8) 00 (5) 80 (396) DAX007 3 (0) 47.8 48. 48.4 0.7.06 (30.7) 30 35 70 A ±5 ±5 90 (8) 00 (5) 90 (638) DAX07 3.7 () 49. 49.6 49.9 0.5.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 00 (5) 40 (94) DA87.4 (8) 47.6 47.7 47.9 0.7.08 (8.3) 30 7 A ±5 ±5 90 (8) 00 (5) 80 (396) UA87.4 (8) 47.6 47.7 47.9 0.7.08 (8.3) 30 74 3 A ±5 ±5 90 (8) 00 (5) 80 (396) DA07 3 (0) 49.4 49.5 49.7 0.6.08 (8.3) 30 7 A ±5 ±5 90 (8) 00 (5) 90 (638) UA07 3 (0) 49.4 49.5 49.7 0.6.08 (8.3) 30 76 3 A ±5 ±5 90 (8) 00 (5) 90 (638) DAX87.4 (8) 47.4 47.5 47.7 0.7.08 (8.3) 30 35 70 A ±5 ±5 90 (8) 00 (5) 80 (396) DAX07 3 (0) 49. 49.3 49.5 0.6.08 (8.3) 30 35 7 A ±5 ±5 90 (8) 00 (5) 90 (638) DA84.4 (8) 48.3 48.5 48.8 0.6.0 (6.4) 30 70 ±5 ±5 90 (8) 00 (5) 80 (396) UA84.4 (8) 48.3 48.5 48.8 0.6.0 (6.4) 30 73 3 ±5 ±5 90 (8) 00 (5) 80 (396) DAX84.4 (8) 48.3 48.5 48.8 0.6.0 (6.4) 30 35 69 ±5 ±5 90 (8) 00 (5) 80 (396) Performance specifications PAD and PADX 5.75 to 6.875 5.75 to 7.5 5.95 to 6.45 5.95 to 6.875 6.45 to 7.5 PAD6W57.8 (6) 38. 38.9 39.7.9.5 (3.) 30 55 A ±5 ±5 90 (8) 00 (5) 65 (4) PAD8W57.4 (8) 40.6 4.4 4..4.5 (3.) 30 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PAD0W57 3 (0) 4.6 43.5 44...5 (3.) 30 6 A ±5 ±5 90 (8) 00 (5) 64 (585) PADX8W57.4 (8) 40.4 4. 4.0.4.0 (6.4) 30 35 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PADX0W57 3 (0) 4.3 43. 43.9..0 (6.4) 30 35 59 A ±5 ±5 90 (8) 00 (5) 64 (585) PADX6U57.8 (6) 37.9 38.9 39.8.7.5 (3.) 30 35 55 A ±5 ±5 90 (8) 00 (5) 65 (4) PADX8U57.4 (8) 40.4 4.4 4.3.3.5 (3.) 30 35 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PADX0U57 3 (0) 4.3 43. 44...5 (3.) 30 35 59 A ±5 ±5 90 (8) 00 (5) 64 (585) PAD659.8 (6) 38.4 38.7 39..8.06 (30.7) 30 55 A ±5 ±5 90 (8) 00 (5) 84 (85) PAD859.4 (8) 40.9 4.3 4.6.4.06 (30.7) 30 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PAD059 3 (0) 4.8 43. 43.5..06 (30.7) 30 6 A ±5 ±5 90 (8) 00 (5) 64 (585) PADX6W59.8 (6) 38. 38.9 39.5.7.0 (6.4) 30 35 55 A ±5 ±5 90 (8) 00 (5) 65 (4) PADX8W59.4 (8) 40.7 4.4 4.0.3.0 (6.4) 30 35 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PADX0W59 3 (0) 4.7 43.4 44.0..0 (6.4) 30 35 59 A ±5 ±5 90 (8) 00 (5) 64 (585) PAD665.8 (6) 39. 39.6 40.6.06 (30.7) 30 57 A ±5 ±5 90 (8) 00 (5) 84 (85) PAD865.4 (8) 39. 39.6 40.6.06 (30.7) 30 57 A ±5 ±5 90 (8) 00 (5) 30 (85) PAD065 3 (0) 43.5 43.9 44.3..06 (30.7) 30 63 A ±5 ±5 90 (8) 00 (5) 64 (585) PAD607.8 (6) 43.5 43.9 44.3.06 (30.7) 30 60 A ±5 ±5 90 (8) 00 (5) 65 (4) PAD807.4 (8) 46 46.4 46.8 0.7.06 (30.7) 30 6 A ±5 ±5 90 (8) 00 (5) 30 (85) 0.7 to.7 PADX607.4 (8) 43.5 43.9 44.3.06 (30.7) 30 35 60 A ±5 ±5 90 (8) 00 (5) 65 (4) PADX807.4 (8) 46 46.4 46.8 0.7.06 (30.7) 30 35 6 A ±5 ±5 90 (8) 00 (5) 30 (85) PADX007 3 (0) 47.9 48.3 48.5 0.7.06 (30.7) 30 35 64 A ±5 ±5 90 (8) 00 (5) 64 (585).5 @ 5.755.85 GHz 4 @ 5.755.85 GHz The performance specifications in this table apply to antennas categorized under Configuration in the associated wind speed and sway bar selection guide. In most cases, Configuration antennas offer a survival wind speed of 00 km/h. However, most 00 km/h antennas (except 4.6 m (5 ft) models) are also available in models that offer higher survival wind speed performance. Wind speed and sway bar selection guide A wind speed, perimeter sway bar and sway bar connecting kit are available to complement your RFS TrunkLine antennas: A wind kit increases antenna survival wind speed support from 00 km/h (5 mph) to 5 km/h (55 mph). Wind kits give customers the flexibility to upgrade survival wind speed support levels in the field during installation if wind conditions are more severe than anticipated. An optional perimeter sway bar provides added assurance in case mistakes are made during installation. A universal sway bar tower connecting kit allows sway bars to be attached to pipes or Lstructures without drilling a hole in the pipe or structure. Sizes (ft) 6 8 0 5 Model (Prefix) DA/DAX/UA/UDA DA/DAX/UA/UDA DA/DAX/UA/UDA DA/DAX/UA/UDA DA/DAX/UA/UDA Wind Speed Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration (km/h) 00 5* 00 5* 00 5* 00 5* 00 Not Available Sway Bar Qty 4 Not Available 5 km/h Windkit Additional Perimeter Sway Bar Sway Bar Tower Fixation Kit SMAWK6A SMASK60000A SMAWK8 SMAWK0 SMASK603000A SMASKOUNIVERSALL SMAWK Not Available Not Available * Order as a unique model number. For example: DAX865AD is the standard 00 km/h (5 mph) version; DAX865AD is the 5 km/h (55 mph) version. See page 0 for details. 9
UXA antenna RFS PrimeLine (UXA) polarized antennas delivering ultrahigh performance and the highest XPD 0 0 HH Horizontally polarized antenna HV VH Vertically polarized antenna VV Engineering A 0 Scale Change Scale Change Copolar 0 db db 0 0 Designed for: All applications that require the best RF performance, especially where interference could be an issue 30 40 50 CrossPolar 30 40 50 Installed on: Rooftop poles or towers Featuring: Extremely high XPD for complete isolation between the radios in each polarization Tested and validated ultrahigh (ETSI EN 30 7 Class 3 and FCC Class A) electrical performance 60 70 Expanded Scale 80 80 80 5 0 5 0 5 0 5 0 0 40 40 60 60 80 80 00 00 0 0 40 40 60 60 80 Degrees RFS PrimeLine antennas offer XPD that is typically higher than 40 db, very low secondary lobe levels and excellent fronttoback ratios 60 70 Excellent radiation pattern envelope (RPE), particularly in the crosspolar area Support for winds up to 00 km/h (5 mph) with highwind versions that support winds up to 5 km/h (55 mph) and an optional sway bar for added assurance in case mistakes are made during installation Ability to change frequencies in the field in most cases Available in: Frequencies ranging from 3.6 GHz to 3.6 GHz with support for two wideband frequency ranges (5.756.875 and 5.956.875) to reduce antenna requirements and simplify logistics Sizes ranging from 0.6 m ( ft) to 4.6 m (5 ft) Configurations with singlepiece or split reflectors; RFS recommends singlepiece reflectors for optimal performance Please contact your RFS representative to verify which RFS PrimeLine antenna models support this upgrade in the field Split reflectors are available on request for.4 m to 3.7 m (8 ft to ft) antennas. 0
Antenna models Frequency Range (GHz) Sizes (m) Sizes (ft) Model Name ( Polarized) 3.64. 4.45 5.756.875 5.757.5 5.956.45 5.956.875 6.457.5 7.57.75 7.758.5 0.30.7 0.50.7 0.7.7.73.5 4.5.35 7.79.7.3.6.8 6 UXA636.4 8 UXA836 3 0 UXA036 3.7 UXA36 4.6 4 UXA536.8 6 UXA644.4 8 UXA844 3 0 UXA044 3.7 UXA44 4.6 4 UXA544.8 6 UXA6W57,.4 8 UXA8W57, 3 0 UXA0W57,.8 6 UXA6U57.4 8 UXA8U57 3.0 0 UXA0U57. 4 UXA459.8 6 UXA659.4 8 UXA859 3 0 UXA059 3.7 UXA59 4.6 5 UXA559.8 6 UXA6W59,.4 8 UXA8W59, 3 0 UXA0W59, 3.7 UXAW59,. 4 UXA465.8 6 UXA665.4 8 UXA865 3 0 UXA065 3.7 UXA65 4.6 5 UXA565. 4 UXA47.8 6 UXA67.4 8 UXA87 3 0 UXA07 3.7 UXA7 4.6 5 UXA57. 4 UXA478.8 6 UXA678.4 8 UXA878 3 0 UXA078 3.7 UXA78 4.6 5 UXA578. 4 UXA403.8 6 UXA603.4 8 UXA803 3 0 UXA003 3.7 UXA03. 4 UXA405.8 6 UXA605. 4 UXA407.8 6 UXA607.4 8 UXA807 3 0 UXA007 3.7 UXA07. 4 UXA47.8 6 UXA67.4 8 UXA87 3 0 UXA07 0.6 UXA4. 4 UXA44.8 6 UXA64.4 8 UXA84 0.6 UXA90. 4 UXA490.8 6 UXA690 0.6 UXA0. 4 UXA40.8 6 UXA60 This table summarizes the main RFS PrimeLine models. Additional antenna variants and customized versions are also available. For example, RFS PrimeLine antennas can be upgraded with our specialized epoxy paints and corrosionresistant hardware so you can bring ultrahigh performance and the highest XPD levels to the harshest environments. Antenna models that are designed to meet North American standards are also available. To confirm proper ordering models, please contact your RFS representative. Wideband model Available only in North America
RFS PRIMELINE (UXA) Performance specifications Visit our online ecatalog dataxpress for the latest and most complete data specifications: www.rfsworld.com/dataxpress Frequency (GHz) Polarization Model Number Gain (dbi) Diameter 3 dbbw VSWR/R L ETSI Fine Adjust. Windspeed km/h (mph) XPol IPI F/B US FCC Net weight RPE m (ft) (deg) (db) (db) (db) 0 Cat Low Mid High (db) class Az Elev Operational Survival kg (lb) UXA636.8 (6) 33.5 34. 34.8 3.0 (6.4) 35 40 60 3 ±5 ±5 90 (8) 00 (5) 95 (09) UXA836.4 (8) 36.5 37. 37.8.3.08 (8.3) 40 45 66 3 ±5 ±5 90 (8) 00 (5) 80 (396) 3.6 to 4. 4.4 to 5 5.75 to 6.875 5.75 to 7.5 5.95 to 6.45 5.95 to 6.875 6.45 to 7.5 7.5 to 7.75 7.75 to 8.5 0.3 to 0.7 0.5 to 0.7 0.7 to.7 UXA036 3 (0) 38.4 39. 39.7.8.06 (30.7) 40 45 67 3 B ±5 ±5 90 (8) 00 (5) 90 (638) UXA36 3.7 () 40 40.7 4.3.5.06 (30.7) 40 45 70 3 A ±5 ±5 90 (8) 00 (5) 40 (94) UXA536 4.6 (5) 4 4.7 43.3..06 (30.7) 38 45 7 3 A ±5 ±5 90 (8) 00 (5) 750 (650) UXA644.8 (6) 35.6 36. 36.7.4.0 (6.4) 35 40 64 3 ±5 ±5 90 (8) 00 (5) 95 (09) UXA844.4 (8) 38. 38.8 39.6.8.06 (30.7) 40 45 66 3 ±5 ±5 90 (8) 00 (5) 80 (396) UXA044 3 (0) 40. 40.7 4..5.06 (30.7) 40 45 68 3 ±5 ±5 90 (8) 00 (5) 90 (638) UXA44 3.7 () 4.7 4.3 4.8..06 (30.7) 40 45 69 3 ±5 ±5 90 (8) 00 (5) 40 (94) UXA544 4.6 (5) 43.7 44.3 44.8 0.9.06 (30.7) 38 45 7 3 ±5 ±5 90 (8) 00 (5) 750 (650) UXA6W57.8 (6) 38. 38.9 39.7.08 (8.3) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA8W57.4 (8) 40.6 4.4 4..5.08 (8.3) 40 45 77 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA0W57 3 (0) 4.5 43.4 44...08 (8.3) 40 45 79 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA6U57.8 (6) 38. 39 40.7. (5) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA8U57.4 (8) 40.6 4.6 4.6.3. (5) 40 45 77 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA0U57 3 (0) 4.5 43.4 44.4.. (5) 40 45 79 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA459. (4) 34. 34.5 34.8.8.0 (6.4) 38 4 60 3 B ±5 ±5 90 (8) 00 (5) 45 (99) UXA659.8 (6) 38.3 38.7 39.9.06 (30.7) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA859.4 (8) 40.9 4.3 4.7.5.06 (30.7) 40 45 7 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA059 3.0 (0) 4.9 43. 43.5..06 (30.7) 40 45 74 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA59 3.7 () 44.6 44.8 45. 0.9.06 (30.7) 40 45 76 3 A ±5 ±5 90 (8) 00 (5) 40 (94) UXA559 4.6 (5) 46.3 46.6 47 0.8.06 (30.7) 38 45 77 3 A ±5 ±5 90 (8) 00 (5) 750 (650) UXA6W59.8 (6) 38.4 39. 39.7.9.08 (8.3) 40 45 75 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA8W59.4 (8) 40.9 4.6 4..4.08 (8.3) 40 45 77 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA0W59 3.0 (0) 4.9 43.5 44..08 (8.3) 40 45 73 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXAW59 3.7 () 44.6 45. 45.7 0.8.08 (8.3) 40 45 75 3 A ±5 ±5 90 (8) 00 (5) 40 (94) UXA465. (4) 34.8 35.3 35.7.5.0 (6.4) 38 4 6 3 B ±5 ±5 90 (8) 00 (5) 45 (99) UXA665.8 (6) 39. 39.7 40..7.06 (30.7) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA865.4 (8) 4.8 4. 4.7.3.06 (30.7) 40 45 7 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA065 3 (0) 43.5 43.9 44.4.06 (30.7) 40 45 74 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA65 3.7 () 45. 45.6 46 0.8.06 (30.7) 40 45 76 3 A ±5 ±5 90 (8) 00 (5) 40 (94) UXA565 4.6 (5) 47 47.5 47.9 0.8.06 (30.7) 38 45 77 3 A ±5 ±5 90 (8) 00 (5) 750 (650) UXA47. (4) 35.7 36. 36.4..0 (6.4) 38 4 6 3 ±5 ±5 90 (8) 00 (5) 45 (99) UXA67.8 (6) 39.9 40.3 40.6.5.06 (30.7) 40 45 68 3 ±5 ±5 90 (8) 00 (5) 95 (09) UXA87.4 (8) 4.4 4.8 43...06 (30.7) 40 45 7 3 ±5 ±5 90 (8) 00 (5) 80 (396) UXA07 3 (0) 44.4 44.7 45. 0.9.06 (30.7) 40 45 74 3 ±5 ±5 90 (8) 00 (5) 90 (638) UXA7 3.7 () 46 46.4 46.8 0.7.06 (30.7) 40 45 76 3 ±5 ±5 90 (8) 00 (5) 40 (94) UXA57 4.6 (5) 47.9 48.3 48.6 0. 6.06 (30.7) 38 45 77 3 ±5 ±5 90 (8) 00 (5) 750 (650) UXA478. (4) 36.8 37. 37.6..08 (8.3) 38 4 6 3 ±5 ±5 90 (8) 00 (5) 45 (99) UXA678.8 (6) 40.6 4. 4.4.5.06 (30.7) 40 45 70 3 ±5 ±5 90 (8) 00 (5) 95 (09) UXA878.4 (8) 43. 43.6 43.9..06 (30.7) 40 45 73 3 ±5 ±5 90 (8) 00 (5) 80 (396) UXA078 3.0 (0) 45. 45.5 45.9 0.9.06 (30.7) 40 45 76 3 ±5 ±5 90 (8) 00 (5) 90 (638) UXA78 3.7 () 46.7 47. 47.5 0.7.06 (30.7) 40 45 77 3 ±5 ±5 90 (8) 00 (5) 40 (94) UXA578 4.6 (5) 48.6 49 49.4 0.6.06 (30.7) 38 45 78 3 ±5 ±5 90 (8) 00 (5) 750 (650) UXA403. (4) 39.5 39.7 39.8.7.0 (6.4) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 40 (88) UXA603.8 (6) 43. 43.3 43.4.08 (8.3) 40 45 73 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA803.4 (8) 45.6 45.8 45.9 0.8.08 (8.3) 40 45 76 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA003 3 (0) 47.5 47.7 47.8 0.7.08 (8.3) 40 45 78 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA03 3.7 () 48.9 49. 49. 0.5.08 (8.3) 40 45 78 3 A ±5 ±5 90 (8) 00 (5) 40 (94) UXA405. (4) 39.7 39.8 39.9.7.08 (8.3) 40 45 69 3 A ±5 ±5 90 (8) 00 (5) 45 (99) UXA605.8 (6) 43. 43.3 43.4..06 (30.7) 40 45 75 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA407. (4) 40 40.4 40.8.5.08 (8.3) 40 45 70 3 A ±5 ±5 90 (8) 00 (5) 40 (88) UXA607.8 (6) 43.5 43.8 44.3.06 (30.7) 40 45 73 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA807.4 (8) 45.9 46. 46.7 0.8.06 (30.7) 40 45 75 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA007 3 (0) 47.8 48. 48.4 0.7.06 (30.7) 40 45 77 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA07 3.7 () 49. 49.6 49.9 0.5.06 (30.7) 40 45 78 3 A ±5 ±5 90 (8) 00 (5) 40 (94)
Performance specifications Frequency (GHz) Polarization Model Number Gain (dbi) ETSI Fine Adjust. Windspeed km/h (mph) Diameter 3 dbbw VSWR/R L XPol IPI F/B US FCC Net weight RPE m (ft) (deg) (db) (db) (db) 0 Cat Low Mid High (db) class Az Elev Operational Survival kg (lb) UXA47. (4) 4.3 4.4 4.6.7.0 (6.4) 40 45 67 3 A ±5 ±5 90 (8) 00 (5) 45 (99) UXA67.8 (6) 45 45. 45.3 0.9.0 (6.4) 40 45 73 3 A ±5 ±5 90 (8) 00 (5) 95 (09).7 to 3.5 UXA87.4 (8) 47.4 47.5 47.7 0.7.0 (6.4) 40 45 75 3 A ±5 ±5 90 (8) 00 (5) 80 (396) UXA07 3.0 (0) 49. 49.3 49.5 0.6.0 (6.4) 40 45 76 3 A ±5 ±5 90 (8) 00 (5) 90 (638) UXA4 0.6 () 36.3 36.5 36.8.3.3 (4.3) 36 40 64 3 ±3 ±30 90 (8) 5 (55) 5 (33) UXA44. (4) 4.3 4.5 4.8..0 (6.4) 36 40 70 3 ±5 ±5 90 (8) 00 (5) 40 (88) 4. to 5.35 UXA64.8 (6) 45.8 46 46.3 0.8.0 (6.4) 38 40 75 3 ±5 ±5 90 (8) 00 (5) 95 (09) UXA84.4 (8) 48.3 48.5 48.8 0.6.0 (6.4) 38 40 76 3 ±5 ±5 90 (8) 00 (5) 80 (396) UXA90 0.6 () 37.8 38.3 38.7.9.3 (4.3) 36 40 66 3 A ±3 ±30 90 (8) 5 (55) 5 (33) 7.7 to 9.7 UXA490. (4) 44 44.5 44.9 0.9.3 (4.3) 36 40 7 3 A ±5 ±5 90 (8) 00 (5) 40 (88) UXA690.8 (6) 47.5 48 48.4 0.7.3 (4.3) 36 40 76 3 A ±5 ±5 90 (8) 00 (5) 95 (09) UXA0 0.6 () 39.5 40 40.5.6.5 (3.) 36 40 66 3 A ±3 ±30 90 (8) 5 (55) 5 (33). to 3.6 UXA40. (4) 45.5 46 46.4 0.8.3 (4.3) 36 40 7 3 A ±5 ±5 90 (8) 00 (5) 40 (88) UXA60.8 (6) 49 49.5 49.9 0.5.3 (4.3) 36 40 76 3 A ±5 ±5 90 (8) 00 (5) 95 (09).5 @ 5.755.85 GHz 4 @ 5.755.85 GHz The performance specifications in this table apply to antennas categorized under Configuration in the associated wind speed and sway bar selection guide. In most cases, Configuration antennas offer a survival wind speed of 00 km/h. However, most 00 km/h antennas (except 4.6 m (5 ft) models) are also available in models that offer higher survival wind speed performance. Wind speed and sway bar selection guide A wind kit, perimeter sway bar and sway bar connecting kit are available to complement your RFS PrimeLine antennas: A wind kit increases antenna survival wind speed support from 00 km/h (5 mph) to 5 km/h (55 mph). Wind kits give customers the flexibility to upgrade survival wind speed support levels in the field during installation if wind conditions are more severe than anticipated. An optional perimeter sway bar provides added assurance in case mistakes are made during installation A universal sway bar tower connecting kit allows sway bars to be attached to pipes or Lstructures without drilling a hole in the pipe or structure. Sizes (ft) 4 4 6 8 0 Model (Prefix) UXA UXA (below 0GHz) UXA UXA UXA UXA UXA Wind Speed (km/h) 5 Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration 00 5* 00 5* 00 5* 00 5* 00 5* 00 5* Sway Bar Qty 0 0 SMAWK4 SMAWK4A SMAWK6A SMAWK8 SMAWK0 SMAWK 5 km/h Windkit Additional Perimeter Sway Bar Sway Bar Tower Fixation Kit Not Available Not Available SMASKOUNIVERSAL SMASK4 SMASK60000A SMASK603000A SMASKOUNIVERSALL *Order as a unique model number. For example: UXA665BD is the standard 00 km/h (5 mph) version; UXA665BD is the 5 km/h (55 mph) version. See page 0 for details. 3
RFS Harsh Areas Line Robust antennas for the harshest environmental conditions Designed for: Marine environments, offshore locations, industrial and highly corrosive locations, volcanic areas, tropical climates, mountaintops with severe wind, ice and snow conditions Installed on: Rooftop poles or towers RFS Harsh Areas Line antennas help Pioneer Cellular maintain communications after a severe ice storm in Oklahoma, United States Despite the damage they sustained, the RFS microwave antenna systems that comprise approximately 98 percent of the 00hop microwave backhaul network remained functional. Featuring: Reflectors and shrouds painted inside and outside with a twocomponent epoxy paint Feeds painted with a twocomponent epoxy paint Mounting hardware and attachment hardware in corrosionresistant ISO 3506 A4 (SAE 36L) steel stabilized with molybdenum Steel mounting with an extended galvanic layer Additional silicon sealant applied to screws, connectors and couplings during installation Factoryinstalled equipment to support winds up to 5 km/h (55 mph) A singlepiece reflector to ensure all antenna surfaces are treated and protected A flexible radome that is designed to avoid snow accumulation Available in: Frequencies ranging from 3.6 GHz to 6.5 GHz with support for a wideband frequency range (7.58.5) to reduce antenna requirements and simplify logistics Sizes ranging from 0.6 m ( ft) to 3.7 m ( ft) and dualpolarized models with the ability to upgrade from single to dual polarization and change frequencies in the field Provided on all RFS Harsh Areas Line antennas. m (4 ft) and larger. Please contact your RFS representative to verify which RFS Harsh Areas Line antenna models support these upgrades in the field. 4
Antenna models Frequency Range (GHz) Sizes (m) Sizes (ft) 3.64. 4.45 5.956.45 6.457.5 7.58.5 0.30.7 0.7.7.73.5 4.5.35 7.79.7.3.6 4.56.5 Wideband model Model Name ( Polarized) Model Name ( Polarized).4 8 DA836**H DAX836**H 3 0 DA036**H DAX036**H 3.7 DA36**5H DAX36**5H.4 8 DA844**H DAX844**H 3 0 DA044**H DAX044**H 3.7 DA44**5H DAX44**5H. 4 SU459**H SUX459**H.8 6 SU659**H SUX659**H.4 8 DA859**H DAX859**H 3 0 DA059**H DAX059**H 3.7 DA59**5H DAX59**5H. 4 SU465**H SUX465**H.8 6 SU665**H SUX665**H.4 8 DA865**H DAX865**H 3 0 DA065**H DAX065**H 3.7 DA65**5H DAX65**5H 0.6 SUW7**H. 4 SU4W7**H SUX4W7**H.8 6 SU6W7**H SUX6W7**H.4 8 DA8W7**H DAX8W7**H 3 0 DA0W7**H DAX0W7**H 3.7 DAW7**5H DAXW7**5H 0.6 SU03**H. 4 SU403**H SUX403**H.8 6 SU603**H SUX603**H.4 8 DA803**H DAX803**H 3 0 DA003**H DAX003**H 3.7 DA03**5H DAX03**5H 0.6 SU07**H. 4 SU407**H SUX407**H.8 6 SU607**H SUX607**H.4 8 DA807**H DAX807**H 3 0 DA007**H DAX007**H 3.7 DA07**H DAX07**5H 0.6 SU7**H SUX7**H. 4 SU47**H SUX47**H.8 6 SU67**H SUX67**H.4 8 DA87**H DAX87**H 3 0 DA07**H DAX07**H 0.6 SU4**H SUX4**H. 4 SU44**H SUX44**H.8 6 SU64**H SUX64**H.4 8 DA84**H DAX84**H 0.6 SU90**H SUX90**H. 4 SU490**H SUX490**H.8 6 SU690**H SUX690**H 0.6 SU0**H SUX0**H. 4 SU40**H SUX40**H.8 6 SU60**H SUX60**H 0.6 SU50**H SUX50**H. 4 SU450**H SUX450**H This table summarizes the main RFS Harsh Areas Line antenna models. Additional antenna variants and customized versions are also available. For example: RFS PrimeLine antenna models can be upgraded with our specialized epoxy paints and corrosionresistant hardware so you can bring ultrahigh performance and the highest XPD levels to the harshest environments. RFS can develop customized Harsh Areas Line antennas to meet requirements for specific projects or specific wind, humidity, ice, snow, volcanic ash or pollution challenges. An antenna ice shield is also available in North America. ** : these digits indicates the antenna revision index and the flange option see the RFS naming structure in page 0 for more details. To confirm proper ordering models, please contact your RFS representative. 5
RFS HARSH AREAS LINE Performance specifications Visit our online ecatalog dataxpress for the latest and most complete data specifications: www.rfsworld.com/ Frequency (GHz) 3.6 to 4. 4.4 to 5 5.95 to 6.45 6.45 to 7.5 7.5 to 8.5 0.3 to 0.7 0.7 to.7 Polarization Model Number Diameter Gain (dbi) ETSI Fine Adjust. Windspeed km/h (mph) 3 dbbw VSWR/R L XPol IPI F/B US FCC Net weight RPE m (ft) (deg) (db) (db) (db) 0 Cat Low Mid High (db) class Az Elev Operational Survival kg (lb) DA836**H.4 (8) 36.5 37. 37.8.3.06 (30.7) 30 60 ±5 ±5 90 (8) 5 (55) 90 (49) DA036**H 3 (0) 38.4 39. 39.7.8.06 (30.7) 30 6 ±5 ±5 90 (8) 5 (55) 30 (706) DA36**5H 3.7 () 40.0 40.7 4.3.5.06 (30.7) 30 63 B ±5 ±5 90 (8) 5 (55) 470 (037) DAX836**H.4 (8) 36.5 37. 37.8.3.08 (8.3) 30 35 60 ±5 ±5 90 (8) 5 (55) 90 (49) DAX036**H 3 (0) 38.4 39. 39.7.8.06 (30.7) 30 35 6 ±5 ±5 90 (8) 5 (55) 30 (706) DAX36**5H 3.7 () 40.0 40.7 4.3.5.06 (30.7) 30 35 63 B ±5 ±5 90 (8) 5 (55) 470 (037) DA844**H.4 (8) 38.5 39. 39.6.8.06 (30.7) 30 65 ±5 ±5 90 (8) 5 (55) 90 (49) DA044**H 3 (0) 40.4 4 4.5.5.06 (30.7) 30 67 ±5 ±5 90 (8) 5 (55) 30 (706) DA44**5H 3.7 () 4 4,6 43...06 (30.7) 30 68 ±5 ±5 90 (8) 5 (55) 470 (037) DAX844**H.4 (8) 38. 38.8 39.6.8.06 (30.7) 30 35 64 ±5 ±5 90 (8) 5 (55) 90 (49) DAX044**H 3 (0) 40. 40.7 4..5.06 (30.7) 30 35 66 ±5 ±5 90 (8) 5 (55) 30 (706) DAX44**5H 3.7 () 4.7 4.3 4.8..06 (30.7) 30 35 67 ±5 ±5 90 (8) 5 (55) 470 (037) SU459***H. (4) 34.9 35.3 35.6.8.5 (3.) 30 6 3 B ±5 ±5 90 (8) 5 (55) 45 (99) SU659***H.8 (6) 38.3 38.8 39..9.5 (3.) 30 64 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DA859***H.4 (8) 4. 4.6 4.5.06 (30.7) 30 66 A ±5 ±5 90 (8) 5 (55) 90 (49) DA059***H 3 (0) 43 43.4 43.7..06 (30.7) 30 69 A ±5 ±5 90 (8) 5 (55) 30 (706) DA59***5H 3.7 () 44.8 45. 45.4 0.9.06 (30.7) 30 70 A ±5 ±5 90 (8) 5 (55) 470 (037) SUX459***H. (4) 34. 34.5 34.8.8.5 (3.) 30 35 60 3 B ±5 ±5 90 (8) 5 (55) 45 (99) SUX659***H.8 (6) 38. 38.6 38.9.9.5 (3.) 30 35 64 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DAX859***H.4 (8) 40.9 4.3 4.7.5.06 (30.7) 30 35 67 A ±5 ±5 90 (8) 5 (55) 90 (49) DAX059***H 3 (0) 4.9 43. 43.5..06 (30.7) 30 35 69 A ±5 ±5 90 (8) 5 (55) 30 (706) DAX59***5H 3.7 () 44.6 44.8 45. 0.9.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 5 (55) 470 (037) SU465***H. (4) 35.6 36 36.5.5.5 (3.) 30 6 3 B ±5 ±5 90 (8) 5 (55) 45 (99) SU665***H.8 (6) 39. 39.7 40..7.5 (3.) 30 65 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DA865***H.4 (8) 4.9 4.3 4.8.3.06 (30.7) 30 66 A ±5 ±5 90 (8) 5 (55) 90 (49) DA065***H 3 (0) 43.7 44. 44.6.06 (30.7) 30 69 A ±5 ±5 90 (8) 5 (55) 30 (706) DA65***5H 3.7 () 45.3 45.8 46. 0.8.06 (30.7) 30 70 A ±5 ±5 90 (8) 5 (55) 470 (037) SUX465***H. (4) 34.8 35.3 35.7.5.5 (3.) 30 35 6 3 B ±5 ±5 90 (8) 5 (55) 45 (99) SUX665***H.8 (6) 39.0 39.5 39.9.7.5 (3.) 30 35 65 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DAX865***H.4 (8) 4.8 4. 4.7.3.06 (30.7) 30 35 68 A ±5 ±5 90 (8) 5 (55) 90 (49) DAX065***H 3 (0) 43.5 43.9 44.4.06 (30.7) 30 35 70 A ±5 ±5 90 (8) 5 (55) 30 (706) DAX65***5H 3.7 () 45. 45.6 46.0 0.8.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 5 (55) 470 (037) SUW7***H 0.6 () 30.8 3.3 3.9 4.3.0 (0.8) 30 55 ±3 ±30 90 (8) 5 (55) 5 (33) SU4W7***H. (4) 36. 36.9 37.6..5 (3.) 30 63 3 ±5 ±5 90 (8) 5 (55) 45 (99) SU6W7***H.8 (6) 40 40.8 4.6.5.5 (3.) 30 67 3 ±5 ±5 90 (8) 5 (55) 5 (54) DA8W7***H.4 (8) 4.6 43.3 44...0 (6.4) 30 68 ±5 ±5 90 (8) 5 (55) 90 (49) DA0W7***H 3 (0) 44.6 45.3 46. 0.9.0 (6.4) 30 70 ±5 ±5 90 (8) 5 (55) 30 (706) DAW7***5H 3.7 () 46. 47 47.7 0.7.0 (6.4) 30 7 ±5 ±5 90 (8) 5 (55) 470 (037) SUX4W7***H. (4) 36. 36.8 37.5..9 (.) 30 35 63 3 ±5 ±5 90 (8) 5 (55) 45 (99) SUX6W7***H.8 (6) 39.8 40.6 4.4.5.9 (.) 30 35 67 3 ±5 ±5 90 (8) 5 (55) 5 (54) DAX8W7***H.4 (8) 4.4 43. 43.9..0 (6.4) 30 35 68 ±5 ±5 90 (8) 5 (55) 90 (49) DAX0W7***H 3 (0) 44.4 45. 45.9 0.9.0 (6.4) 30 35 70 ±5 ±5 90 (8) 5 (55) 30 (706) DAXW7***5H 3.7 () 46.0 46.7 47.5 0.7.0 (6.4) 30 35 7 ±5 ±5 90 (8) 5 (55) 470 (037) SU03***H 0.6 () 33.4 33.6 33.8 3..0 (0.8) 30 59 3 ±3 ±30 90 (8) 5 (55) 5 (33) SU403***H. (4) 39.6 39.8 39.9.6.5 (3.) 3 65 3 A ±5 ±5 90 (8) 5 (55) 45 (99) SU603***H.8 (6) 43. 43.4 43.5.5 (3.) 3 70 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DA803***H.4 (8) 45.7 45.9 46 0.8.08 (8.3) 30 68 A ±5 ±5 90 (8) 5 (55) 90 (49) DA003***H 3 (0) 47.6 47.8 47.9 0.7.08 (8.3) 30 70 A ±5 ±5 90 (8) 5 (55) 30 (706) DA03***5H 3.7 () 49 49. 49.3 0.5.08 (8.3) 30 7 A ±5 ±5 90 (8) 5 (55) 470 (037) SUX403***H. (4) 39.5 39.7 39.8.6.0 (0.8) 3 35 65 3 A ±5 ±5 90 (8) 5 (55) 45 (99) SUX603***H.8 (6) 43. 43.3 43.4.0 (0.8) 3 35 70 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DAX803***H.4 (8) 45.6 45.8 45.9 0.8.08 (8.3) 30 35 68 A ±5 ±5 90 (8) 5 (55) 90 (49) DAX003***H 3 (0) 47.5 47.7 47.8 0.7.08 (8.3) 30 35 70 A ±5 ±5 90 (8) 5 (55) 30 (706) DAX03***5H 3.7 () 48.9 49. 49. 0.5.08 (8.3) 30 35 7 A ±5 ±5 90 (8) 5 (55) 470 (037) SU07***H 0.6 () 33.8 34. 34.6 3..0 (0.8) 30 60 ±3 ±30 90 (8) 5 (55) 5 (33) SU407***H. (4) 40. 40.5 40.9.5.5 (3.) 3 66 3 A ±5 ±5 90 (8) 5 (55) 45 (99) SU607***H.8 (6) 43.7 44 44.5.5 (3.) 3 70 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DA807***H.4 (8) 46. 46.4 46.9 0.8.06 (30.7) 30 7 A ±5 ±5 90 (8) 5 (55) 90 (49) DA007***H 3 (0) 48 48.4 48.6 0.7.06 (30.7) 30 7 A ±5 ±5 90 (8) 5 (55) 30 (706) DA07***5H 3.7 () 49.4 49.8 50 0.5.06 (30.7) 30 7 A ±5 ±5 90 (8) 5 (55) 470 (037) SUX407***H. (4) 40.0 40.4 40.8.5.0 (0.8) 3 35 66 3 A ±5 ±5 90 (8) 5 (55) 45 (99) SUX607***H.8 (6) 43.6 43.9 44.4.0 (0.8) 3 35 70 3 A ±5 ±5 90 (8) 5 (55) 5 (54) DAX807***H.4 (8) 45.9 46. 46.7 0.8.06 (30.7) 30 35 69 A ±5 ±5 90 (8) 5 (55) 90 (49) DAX007***H 3 (0) 47.8 48. 48.4 0.7.06 (30.7) 30 35 70 A ±5 ±5 90 (8) 5 (55) 30 (706) DAX07***5H 3.7 () 49. 49.6 49.9 0.5.06 (30.7) 30 35 7 A ±5 ±5 90 (8) 5 (55) 470 (037) 6