SCIENCE. SERVICE. SOLUTIONS. WALL INSULATION. R2+ Polyiso Foam Board Wall Insulation

Similar documents
Continuous Insulation Using Polyiso Wall Sheathing

SCIENCE. SERVICE. SOLUTIONS. ROOF GARDEN. CCW Green Roof Systems By Columbia Green Technologies

CommercialComplete Wall System NFPA 285 Tested Wall Assemblies

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Meeting the Fire Code with Continuous Foam Plastic Insulation

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

CHAPTER 7: Building Systems ROOFING SYSTEMS

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

COMMERCIAL BUILDING APPLICATIONS

Renovating Your Basement

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

EcoTouch Insulation with PureFiber Technology

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Fiberglas, Exterior Wall Thermal Insulation

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

FOAMULAR XPS Roof Insulation FOR COMMERCIAL BUILDINGS

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

PVC ROOFING SYSTEMS BUILDING SOLUTIONS A SINGLE SOURCE FOR SINGLE-PLY ROOFING

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Atlas Roofing Corporation insulating sheathing

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Commercial Air Barrier Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

The Case for Cross Laminated Timber: Part 2

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Built to Last. Built for Beauty. Good. Solid. Logix. TM

GreenGuard Housewrap Installation Guide

Avoiding Air Barrier Pitfalls

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Cement Board Exterior Applications Guide

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Underwriters Laboratories Testing Information

Gridstone Gypsum Ceiling Panels

Insulating Basements: Part 3 Basement Wall Systems

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

MASTERFORMAT SPECIFICATION

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Polyurethane Products

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Commercial Wall Designs using Continuous Insulation (CI) under Cladding BCBEC Vancouver and Victoria May 25 th & 26 th, 2011

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

Proven roofing SyStemS

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

2009 IECC Update. Scope. Content. International Energy Conservation Code

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

Compliance Software COMcheck 2 and ENVSTD 3

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

DESIGN GUIDE. Thermal Design and Code Compliance for Cold-Formed Steel Walls Edition

How To Repair A Boat Landing Deck With A Boat Bed

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Roof Insulation Building. Energy. Environment friendly e-library

3M Products for Solar Energy. Designed for efficiency. Built to last.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

HIGH PERFORMANCE BUILDING ENVELOPES. Dave Seifert

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Comment Form on Proposed Gut Rehabilitation Alternatives

United States. Why You Should Insulate Foundations. There is a science to adding value.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

FOAMULAR Tapered Roofi ng Products Extruded Polystyrene (XPS) Rigid Foam Insulation

3M Dual Lock Reclosable Fastener

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Open-cell spray foam & what every contractor

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

03/05/14 REVISOR RSI/JC RD3945

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Insulation R-Value Comparisons

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Spray Polyurethane Foam Insulation. Creating Cost Effective, Energy Efficient, Green Buildings

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Performance of 8 Passive House Envelopes in Cold Climates

R-Value and Densities Chart

Fire-Rated Glass and Glazing START

DEFAULT HEAT LOSS COEFFICIENTS

CUNO TM Series NB Bags for Liquid Filtration

3 Single-Coated Foam Tapes

Product Guide Specification

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Transcription:

SCIENCE. SERVICE. SOLUTIONS. WALL INSULATION R2+ Polyiso Foam Board Wall Insulation 800.527.7092 www.carlisleccw.com

WALL INSULATION R2+ Wall Insulation Energy efficiency is no longer a goal it s a standard a standard that is constantly being raised. In fact, the provisions of the 2012 International Energy Conservation Code (IECC) are designed to produce buildings at least 30% more energy efficient than those built under the 2006 IECC. With building codes and standards constantly changing, the use of energyefficient building products has never been more important. Since the beginning, Carlisle Coatings & Waterproofing Incorporated (CCW) has provided the commercial construction industry with the most high-performance, energy-efficient waterproofing and air and vapor barrier systems on the market. While waterproofing membranes and air and vapor barriers play a significant role in the energy system of the building envelope, insulation is also vital to creating a total building envelope that will reduce long-term energy costs. That is why CCW is now offering a full product line of continuous insulation for use in interior and exterior wall structures. Introducing R2+, a line of polyiso board foam products ideal for providing continuous insulation for wood frame, steel stud, CMU and masonry exterior wall construction. CCW Support and Expertise Insulation, Weatherization + More CCW Polyiso Insulation CCW Air/Vapor Barrier Technology High Energy Efficiency Effective Moisture Management Fire Safety What is Continuous Insulation? According to model energy codes, continuous insulation (ci) is insulation that runs continuously over structural members and is free of signifi cant thermal bridging. Thermal bridging can rob insulation of more than half of its nominal R-value. Ci can be installed on the interior of the exterior side of the wall assembly. Polyiso foam board insulation is an excellent choice for ci because of its high R-value per inch, excellent moisture resistance, rigidity and ease of installation. Building code also requires that wall assemblies in non-combustible (Type I-IV), multi-story construction be tested to NFPA 285. Code requirements for continuous insulation are increasing. The ASHRAE 90.1 2010 Standard requires nonresidential wall insulation assemblies to include continuous exterior insulation across all climate zones. With these ever-increasing building codes and effi ciency requirements, CCW s R2+ product line offers a long-lasting energy-effi cient solution for virtually any interior or exterior wall application. Energy Efficiency CCW s R2+ continuous wall insulation products will work together with CCW air and vapor barrier systems to create a total wall system that not only protects the interior of the building from moisture infi ltration and water migration but also keeps the building well insulated, reducing the heating and cooling requirements and thereby minimizing long-term energy and operating costs. CCW R2+ is a polyiso insulation, which has the highest R-value per inch of any insulation on the market. This signifi cantly increases the thermal effi ciency of the building while also reducing waste on the jobsite. Because of its high R-value per inch, polyiso requires less material than many other insulation products, reducing the cost of construction and the building s environmental impact. An insulation with higher R-value per inch also facilitates compliance with building codes by making the best use of limited space in the wall cavity.

Fire Resistance & NFPA 285 While foam insulation and membrane air barriers provide enhanced building envelope performance, they are also combustible. In commercial building construction of primarily non-combustible materials, the addition of combustible materials to the assembly prompts various fire tests by IBC, especially when the wall assembly in non-combustible multi-story wall construction (Type I-IV) contains combustible cladding, insulation or membrane. In this instance, the IBC requires an NFPA 285 full wall burn test. CCW s R2+ polyiso insulation and CCW s Fire Resist membrane air barriers enable the addition of high R-value continuous insulation plus a generous 40-mil membrane to the wall assembly without compromising fire safety. CCW s R2+ insulation and Fire Resist membrane air barriers have been vigorously tested to ensure they meet and exceed the industry standards and code requirements for commercial construction. Furthermore, NFPA 285 walls that incorporate R2+ insulation do not require fire blocking at the widow head condition. Due to its thermoset chemistry, polyiso burns slowly when exposed to fire but stays in place. This offers an advantage over thermoplastic foams, such as polystyrene, which typically require fire blocking at the window head because they melt and burn when exposed to flame. Fire blocking adds significant cost and complexity to construction, as shown here. CCW currently offers more than 1,000 NFPA 285 compliant wall assemblies with R2+ insulation, and the selection continues to grow as testing continues. CCW s experienced staff of design and technical experts are available to walk you through the options to determine which assembly is the right choice for your building. R2+ Window Head Insulating Sheathing Directly Over Steel Studs Gypsum Sheathing Over Steel Studs XPS Window Head Fire Blocking Across Window Head Potential LEED Credits for Polyiso Energy and Atmosphere Minimum Energy Performance, Optimize Energy Performance Materials & Resources Building Reuse, Construction Waste Management, Recycled Content, Local and Regional Materials, FSC Wood Products Innovation and Design

WALL INSULATION R2+ Wall Insulation Why Choose CCW R2+? Highest R-value per inch of any insulation Best fi re resistance of any plastic foam board insulation More than 1,000 assemblies that are NFPA 285 compliant Lightweight and easy to install Enhanced moisture resistance closed-cell foam core with moisture-resistant facers Part of a complete wall protection package by CCW - tailored to provide the right insulation, weatherization and fi re safety compliance on your project Manufacturing Locations Manufactured in seven plants throughout the USA by Carlisle Construction Materials, the largest manufacturer of polyiso foam in North America. 1. Kingston, NY 2. Smithfi eld, PA 3. Franklin Park, IL 4. Lake City, FL 5. Terrell, TX 6. Tooele, UT 7. Puyallup, WA 7 1 6 3 2 5 4

Code Compliance CSI Masterformat 2004 Sections 04 27 23 Masonry Cavity Wall Insulation (R2+ SILVER & R2+ MATTE) 06 16 13 Insulating Nail Base (R2+ BASE) 07 21 13 Foam Board Insulation (R2+ SILVER, R2+ MATTE, R2+ SHEATHE) 07 27 23 Board Product Air Barriers (R2+ SILVER, R2+ SHEATHE w/joints sealed and details fl ashed) Standard Specifi cation for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board ASTM C1289,), Grade 2 (20 psi) and Grade 3 (25 psi) 2012 International Building Code (IBC) Section 2603 Plastic Foam Insulation 2012 International Energy Conservation Code (IECC) Table C402.2 walls above-grade continuous insulation ci Section C402.4.1 Air Barriers 2010 ASHRAE 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings Tables 5.5-1 through 5.5-8 walls above-grade continuous insulation ci Section 5.4.3.1 Continuous Air Barrier

WALL INSULATION R2+ Wall Insulation R2+ Insulation Wall Assemblies R2+ Silver Foil-Faced Polyiso Insulation R2+ Matte Coated-Glass-Faced Polyiso Insulation Closed-cell polyiso foam core with tri-laminate foil facers on both sides Continuous insulation suitable for many wall assemblies Qualifi es as an air barrier material according to IECC 2012 and 2010 ASHRAE 90.1 R-values of 6.7 24.6 Available thicknesses: 1" 3.5" Offered in 4' x 8', 16" x 8' and 24" x 8' boards Suitable for masonry cavity wall applications Flame spread <75, Smoke Generation <450 (burn test of polyiso core), ASTM E84 Note: R2+ Silver is not suitable for exposed interior applications. Closed-cell polyiso foam core with coated glass facers on both sides Continuous insulation suitable for many commercial wall assemblies R-values of 6.0 21.7 Available thicknesses: 1" 3.5" Offered in 4' x 8', 16" x 8' and 24" x 8' boards Flame spread <75, Smoke Generation <450 (burn test of polyiso core), ASTM E84 Note: R2+ Matte is not suitable for exposed interior applications.

R2+ Base Commercial Grade Insulating Nail Base R2+ Sheathe Foil-Faced Polyiso Insulating Sheathing Closed-cell polyiso foam core with coated glass facers, laminated to fi re-treated plywood Optimal substrate for mechanically attaching cladding materials Insulating nail base, suitable for many commercial wall assemblies Polyiso foam core: Flame Spread <75, Smoke Generation <450, ASTM E84 Fire-treated plywood: Flame Spread <25, Smoke Generation <450, ASTM E84 R-values of 6.6 19.1 Available thicknesses of 1.6" 3.7" ( 5 /8" fi re-treated plywood with 1" 3"-thick polyiso) FSC Certifi ed wood available R2+ BASE is not suitable for exposed interior applications Enhanced fi re-resist, closed-cell polyiso foam core with embossed aluminum facers, one side silver, one side white Continuous insulated sheathing, suitable for many commercial wall assemblies Qualifi es as an air barrier material according to IECC 2012 and 2010 ASHRAE 90.1 Provides an air barrier and water resistant barrier with secure fastening, taping of joints and fl ashing of details Can be installed directly on steel studs in a variety of wall assemblies without the need for exterior gypsum sheathing Can be installed with the refl ective or the matte side facing the exterior Flame Spread <25, Smoke Generation < 450, ASTM E84 R-values of 6.3 19.5 Available thicknesses: 1' 3.1', optimized thicknesses available for compliance with local code requirements UL Classifi ed Note: R2+ Sheathe is not suitable for exposed interior applications.

R2+ Accessories Insulation Adhesive: CCW LM-800XL solvent-based synthetic rubber Insulation Joint Tape: CCW FOIL-GRIP 1402 17-mil foil/butyl tape Detail fl ashing: Fire Resist CCW-705FR 40-mil glass-backed foil/butyl Transition Membrane: CCW Sure-Seal Pressure-Sensitive Uncured Elastoform Fasteners: Plastic Capped Screws as recommended by CCW* Portable Can Foam: as recommended by CCW* *CCW has tested and verifi ed of these components by other manufacturers. Consult CCW specifi cations and details for latest list of approved products. CCW Fire Resist Membrane Air Barriers CCW-705FR 40-mil Self-Adhered Sheet Air & Vapor Barrier Barritech NP 40-mil Spray/Roller-Applied Air & Vapor Barrier Barritech VP 40-mil Spray/Roller-Applied Vapor-Permeable Air Barrier Limited Warranty Carlisle Coatings & Waterproofi ng, Incorporated (Carlisle) warrants this product to be free of defects in workmanship and materials only at the time of shipment from our factory. If any Carlisle materials prove to contain manufacturing defects that substantially affect their performance, Carlisle will, at its option, replace the materials or refund its purchase price. This limited warranty is the only warranty extended by Carlisle with respect to its materials. There are no other warranties including the implied warranties of merchantability and fi tness for a particular purpose. Carlisle specifi cally disclaims liability for any incidental, consequential or other damages including, but not limited to, loss of profi ts or damages to a structure or its contents arising under any theory of law whatsoever. The dollar value of Carlisle s liability and buyer s remedy under this limited warranty shall not exceed the purchase price of the Carlisle material in question. Carlisle Coatings & Waterproofing 900 Hensley Lane Wylie, TX 75098 800.527.7092 www.carlisleccw.com 06.25.15 2015 Carlisle. REPRINT CODE: 606935 - R2+ Wall Insulation System Brochure Carlisle, R2+, FOIL-GRIP, Sure-Seal and Barritech NP are trademarks of Carlisle.