i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

Similar documents
It s all open from here.

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

HVAC and Lighting Control Products for Open Building Automation Systems

Product Catalog BAS-PRC010-E4. Tracker Version 12 Building Automation System. August 2010

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

CATALYST Frequently Asked Questions

Metering for today s systems

Company Profile. Building Automation / Management system: Capabilities: Supply,Testing and Commissioning

Retail & Commercial Solutions. Siemens EcoView. Energy Management Made Easier.

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

Bring the fresh in. Dedicated Outside Air Systems

Smart Thermostat page 1

Aurora UPC ZS Zone Sensors User Guide

Workshop 7 PC Software - Tracker

Variable Air Volume - VAV

eq Top/TopMaster Air Magic by Fläkt Woods

Daikin VRV Retrofit Provides Comfortable, Quiet Rooms for Residents

Tracer Summit Web Server

KNX for building and room automation simple and efficient

Using Time-of-Day Scheduling To Save Energy

Proper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems. History

February 1, Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

POWER. Your Partners in Availability POWER

WEBs AX Security. Integrated Security With Simple, Web-Based Management

Integrating fire alarm systems with building. Fire Alarm Systems with Building Automation and Control Systems INTEGRATING INTRODUCTION

Controller Operator Guide. VariTrac TM Central Control Panel VAV-SVU01A-EN

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL.

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

HVAC System Optimization

PNNL VOLTTRON TM Application Development

Temperature Control from Lutron

Introduction to Building Automation Systems (BAS)

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

TAC Vista Family TAC Xenta 700 Everything You Need to Monitor and Control Your Building


Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Electronic Control Devices The European Product Catalogue 2007

3466 Building Energy Management Training Systems

Electronic Control Devices The European Product Catalogue 2007

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

Energy-Saving Systems For Small Buildings

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

FX07 Field Controller

Evolution Extreme Heat Pump

Healthcare Solutions Room Pressure Monitors and Controls

CITY OF PORT COLBORNE

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Fundamentals of HVAC Control Systems

Comprehensive Data Center Energy Management Solutions

Integrated Building Management and Security System. Building Automation & Security.

Comprehensive Data Center Energy Management Solutions

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

Tim Sisson - Trane HVAC OVERVIEW

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

ULTIMATE GUIDE TO BUILDING AUTOMATION SYSTEM (BAS)

Guide Specification SECTION COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY

Designer. of control solutions NA O7.124A

Hudson High School Delivering savings through greater efficiency

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

HVAC Systems in Schools & Commercial Buildings and Radon

Infrastructure & Cities Sector

BSD Technical Standard Division 23: HVAC

Integrated Controls & Monitoring System for Apartments. Solution for southern countries.

FULL DC INVERTER SYSTEMS

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

2010 Duct-Free Splits Line Card

T7560A,B,C Digital Wall Module

All the best brands all under one roof

Galaxy VM. Three-phase power protection. schneider-electric.com

The Benefits Really Add Up

Building Technologies

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

FX07 Field Controller

Zoning Reference Guide

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

Supporting ANY PRODUCT employing

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Moving Forward With BACnet

Facilities Management System That Reduces Environmental Burden of Buildings

PRODUCT LIST Facility DDC Access WebXL DDC

Integrated Building Management and Security System. Building Automation & Security.

AMD-33 Air Measuring Station with VCD-33 Control Damper

Tuxedo Touch INFORMATION FOR SECURITY DEALERS. Connect to Opportunity with the Connected Home and Business

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Tracker. Tracker Version 12 Building Automation System BAS-PRC010-EN. March 2008

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

How To Make A Green Building

SAUTER EY-modulo 5. The complete building management solution

HVAC Processes. Lecture 7

EC-Net AX Supervisor with 0 Niagara network connections - for. EC-Net AX Supervisor with 100 Niagara network connections. Includes

Transcription:

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

Comfort and Control for Small to Medium Sized Commercial Buildings In the 1990 s, Carrier invented the first variable volume/variable temperature (VVT ) zoning system for heating, ventilation, and air conditioning. The VVT system provides small to medium-sized commercial buildings with efficient zoned comfort that requires only a single constant volume air source, such as a rooftop unit or heat pump. VVT buildings typically have many spaces with comfort needs that change with the time of day, occupancy patterns and the season. Since its origin, Carrier has fully integrated digital controls into the VVT system, creating a smart network that functions as a seamless unit, responsive to occupants and optimized for efficiency. The system uses an intelligent demand strategy to look at the comfort needs of all the spaces simultaneously and operate in the mode (heating, cooling or ventilation) that best meets those diverse needs. What could be better than this level of comfort and control? Even more control...from anywhere in the world. Today s Carrier i-vu VVT Zoning System delivers precisely controlled comfort by integrating the intelligent VVT network with the Carrier i-vu Building Automation System. This system gives facility managers access to the entire VVT system locally through a wall-mounted touchscreen interface in the building or from anywhere in the world using a standard web-enabled device. With full setpoint control, scheduling, trending, alarming and reporting capabilities, the i-vu Building Automation System provides facility managers with everything they need to accurately manage the VVT system in their building either locally or from any remote location.

Features and Benefits Energy Savings Demand limiting strategy adjusts space setpoints and equipment operation before energy rates increase Demand Controlled Ventilation (DCV), eliminates over-ventilation Setpoint control limits useradjustments Integrated economizer control and night-time free cooling minimize mechanical cooling by using outside air Heating and cooling lockouts prevent mechanical cooling and heating based on outside air conditions Linkage algorithms integrate diverse building demands with mechanical heating and cooling sources Occupant Comfort Adjust individual comfort levels easily with attractive space sensors Convenient i-vu scheduling tool provides temperature control at any time weekdays, weekends, holidays, or after-hours Demand Controlled Ventilation (DCV), ensures ample fresh air at all times Built-in humidity control Integrated optimal start algorithm for conditioning space before occupants arrive Simple and Flexible Fully scalable network architecture - build small or large systems easily and quickly Application-specific controllers - can be factory installed or field-mounted, and include built-in equipment graphics, trends, and alarms for i-vu Pre-engineered control algorithms - simplify system set-up and minimize the need for field programming Streamlined system - eliminates the need for expensive system coordination modules Complete Control Powerful i-vu operator interface Plug-and-play with all Carrier systems Monitor your facility locally through a powerful touchscreen interface, or from anywhere in the world using a standard web browser or mobile device Create schedules, view trends, alarms, custom reports, and much more Easily monitor and control ancillary equipment such as variable speed drives, lighting, and electric meters by adding our programmable controllers Investment Protection Carrier s complete system promises: Reliability - designed by experts and backed by decades of engineering expertise Open standards - built on the widely accepted, ASHRAE standard BACnet protocol Open service - serviceable by a wide variety of trained, tested, and certified Carrier Controls Experts Carrier provides it all equipment and controls coupled with local service and support

How It Works Typical Building System Components 1. Carrier Rooftop Unit Provides efficient, environmentallysustainable heating, cooling and humidity control using a multi-stage compressor and non-ozone depleting Puron (R410a) refrigerant. 2. RTU Open Controller Continuously monitors and precisely regulates constant volume rooftop operation. It controls up to 2 stages of heating (or up to 4 stages in heat pump mode), and 2 stages of cooling (3 stages for 48/50 LC WeatherExpert ). 3. VVT Bypass Damper with Integrated Bypass Controller Because the rooftop unit is supplying a constant volume of air to spaces with varying air requirements, the VVT Bypass Controller tells the VVT Bypass Damper when to open and close in order to maintain the desired static pressure in the supply duct. The VVT Bypass Controller thus enables constant airflow through the air source, while allowing variable airflow to be delivered to the spaces. 4. VVT Zone Damper with Integrated Zone Controller The VVT Zone Controller provides temperature and air quality control by modulating the VVT Zone Damper in order to maintain the space temperature and humidity setpoints in each space. 5. ZS Space Sensors The ZS communicating space sensors tell the VVT Zone Controller when heating or cooling is needed in the space, thus allowing a variable amount of air to be delivered to the space as load dictates. The ZS sensors are available in a variety of space sensing combinations to address your application needs, including temperature, relative humidity, and indoor air quality (CO 2 ). They also offer LCD displays, setpoint adjustment, and local override capabilities to provide highly individualized comfort for occupants. 6. i-vu System Touch This integrated component of the i-vu Building Automation System features an illuminated, 4.3 color pixel touchscreen display and connects directly to the BACnet network. Designed for wall mounting, it provides building occupants, facility managers, and installers a powerful user interface for managing the VVT system in their building. 4. VVT Zone Damper with Integrated VVT Zone Controller 5. ZS Space Sensors 3. VVT Bypass Damper w Int VV Co The i-vu Building Automation System provides everything you need to access, manage, and control your building, including the powerful i-vu user interface, plug-and-play BACnet controllers, and state-of-the-art Carrier equipment. 6. i-vu System Touch

Typical System Components BACnet MS/TP Network The VVT system is comprised of native BACnet, plug-and-play components that talk to each other intelligently using the ASHRAE standard BACnet protocol. 2. RTU Open Controller 1. Carrier Rooftop Unit ith egrated T Bypass ntroller

Optional System Components System User Interface Options The powerful i-vu user interface is available in a variety of options and keeps facilities staff connected to their VVT System at all times. Whether you need local access through a wall-mounted touchscreen or remote access via the web, i-vu connects you immediately, effortlessly and in real time. With i-vu, it s easy to accomplish all of the essential building management functions, including monitoring, control, scheduling, trending, and alarming. i-vu System Touch: Manage your facility locally using a powerful touchscreen interface. Ideal for the facility manager s office. Equipment User Interface and Space Sensor Options i-vu Equipment Touch This touchscreen provides building occupants and facility managers with a powerful user interface for managing a single piece of heating, ventilation and air conditioning (HVAC) equipment in the building (such as a rooftop unit). Designed for wall mounting, it features built-in temperature and humidity sensing, and allows occupants to change setpoints and initiate timed local overrides. i-vu Standard/Plus: Through any web-enabled device, remotely achieve building systems management via a dedicated compact web server that comes with i-vu software pre-installed. Your choice of i-vu Standard or i-vu Plus packages. ZS Space Sensors Carrier s line of intelligent ZS space sensors provides the function and flexibility you need to manage the conditions important to the comfort, productivity, and sustainability of your building. i-vu Pro: Through any web-enabled device, remotely achieve building systems management via i-vu software that has been installed on your PC of choice. Great for applications that require unlimited trending and alarming capabilities, or applications where IT compliance specifications determine what type of i-vu server should be used in the building. The ZS sensors are available in a variety of space sensing combinations to address your application needs, including temperature, relative humidity, and indoor air quality (CO 2 ). ZS Standard ZS Plus ZS Pro

General Purpose Controller Options i-vu s line of general purpose controllers provides auxiliary building control to interface with lighting, fans, pumps, and other heating, ventilation and air conditioning (HVAC) equipment. A library of control programs is available for common applications, and custom programs can be created using Snap graphical programming. All i-vu controllers feature native BACnet communications. UC Open Controller 11 I/O points -> 6 inputs, 5 outputs AppController 14 I/O points -> 6 inputs, 8 outputs UC Open XP Controller 24 I/O points -> 12 inputs, 12 outputs. Supports point expanders to support up to 48 I/O points i-vu Open Link Supports integration using BACnet, Modbus, and LonWorks protocols. Why Choose the Carrier i-vu / VVT Zoning System? Carrier rooftop units or heat pumps provide reliable, efficient, environmentally responsible heating and cooling. Carrier controls provide precise, intelligent adjustment of system components. Carrier i-vu user interfaces provide easy access to system data and system management capabilities. Carrier i-vu VVT Zoning System provides maximal occupant comfort with optimized efficiency and convenient system access from any web-enabled device. Open Service / The Carrier Controls Expert Advantage Wondering which contractor is the best choice to service your building automation system or individual controls? Protect your investment by choosing a factory-authorized Carrier Controls Expert Certified Contractor. The Carrier Controls Expert program trains and certifies an elite class of heating, ventilation and air conditioning (HVAC) contractors who have chosen to install and service the i-vu Building Automation System in commercial buildings. Through thorough training of their specialized service technicians and rigorous, ongoing testing at various Carrier Controls Expert Training Centers certified contractors maintain extensive knowledge of the i-vu Building Automation System and its components. The Carrier Controls Expert Certified Contractor is more than just a vendor. They are a partner dedicated to ensuring that individual controls and the i-vu BAS are correctly maintained. This serves to maximize the value of your systems, to optimize the performance of the facility and to protect your investment in equipment and controls. Select your choice of the Carrier Controls Expert certified contractors in your area, and you ll be sure your installer has the expertise and backing of Carrier whenever they serve your facility. www.carrier.com/controls-experts

System Components Carrier Equipment (includes factory-mounted controller) Part# WeatherExpert, WeatherMaster, or WeatherMaker OPNDRddZC OPND8XwwZC Description Carrier constant-volume, packaged rooftop unit with integrated RTU Open controller. VVT Round Zone Damper with factory-integrated VVT Zone controller, where dd=damper diameter: 08, 10, 12, 14, or 16 inches. VVT Rectangular Zone Damper w/factory-integrated VVT Zone controller, where ww=damper width: 10, 14, 18, or 24 inches. Controls (for field mounting on Carrier or non-carrier HVAC equipment) OPN-RTUM2 OPN-VVTZC OPN-VVTBP RTU Open controller; supports up to 2 stages of heating (or up to 4 stages in heat pump mode), and 2 stages ofcooling (3 stages for 48/50 LC WeatherExpert ). Wiring harnesses (part numbers 48TMHSRADR-A00 and OPN-RTUHRN), provide quick field installation. VVT Zone Controller with integrated actuator (35 in-lb), for single-duct and parallel fan-powered air terminals and supports 2-position hot water, modulating hot water, 2-stage electric heat, or combination baseboard and electric ducted heat. VVT Bypass Controller with integrated actuator (35 in-lb) Space Sensors ZS-CAR ZS Standard Temperature Only ZS-C-CAR ZS Standard Temperature/CO 2 ZS-H-CAR ZS Standard Temperature/RH ZS-HC-CAR ZS Standard Temperature/RH/CO 2 ZSPL-CAR ZS Plus Temperature only. Includes setpoint adjust and local override ZSPL-C-CAR ZS Plus Temperature/CO 2., Includes setpoint adjust and local override ZSPL-H-CAR ZS Plus Temperature/RH. Includes setpoint adjust and local override ZSPL-HC-CAR ZS Plus Temperature/RH/CO 2. Includes setpoint adjust and local override ZSP-CAR ZS Pro Temperature only. Includes LCD display, setpoint adjust, and local override ZSP-C-CAR ZS Pro Temperature/CO 2. Includes LCD display, setpoint adjust, and local override ZSP-H-CAR ZS Pro Temperature/RH. Includes LCD display, setpoint adjust, and local override ZSP-HC-CAR ZS Pro Temperature/RH/CO 2. Includes LCD display, setpoint adjust, and local override General Purpose Controllers (optional) OPN-UC OPN-APP OPN-UCXP OPN-UCXPIO CIV-OL System User Interfaces (optional) SYST1-4-CAR CIV-OPN CIV-OPNPL CIV-OPNPR Equipment User Interfaces (optional) EQT1-4-CAR UC Open controller, supports 11 I/O points total (6 universal inputs, 5 binary outputs). AppController, supports 14 I/O points total (6 universal inputs, 5 binary outputs, 3 analog outputs). UC Open Expandable Controller, supports 24 I/O points total (12 universal inputs, 6 binary outputs, 6 analog outputs). UC Open XP Expander, supports 24 I/O points total (8 binary inputs, 8 analog inputs, 8 binary outputs). i-vu Open Link, supports integration using BACnet, Modbus, or LonWorks protocols. i-vu System Touch touchscreen user interface; manages to up to 60 BACnet MS/TP controllers. i-vu Standard web server with pre-installed i-vu web-based software. i-vu Plus web server with pre-installed i-vu web-based software. i-vu Pro web-based software for installation on any PC. i-vu Equipment Touch touchscreen user interface manages a single piece of HVAC equipment. Includes built-in temperature and humidity sensor for space mounting. For more information, contact your local Carrier Controls Expert. Controls Expert Locator: www.carrier.com/controls-experts Carrier Corporation Cat. No. 11-808-527-01 Rev. 05/16 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs, without notice and without incurring obligations. Trademarks are properties of their respective companies and are hereby acknowledged.