Some Basics of Duct Design and Installation

Similar documents
Residential Duct Systems for New and Retrofit Homes

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

Building Performance Solutions HVAC Design Guide, 2007

FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center

Chapter 8. Duct Design and Sealing

IECC Compliance Guide for Homes in Virginia

Duct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

Duct Construction Standards. Code Reference: 2013 Title 24, Part 6 Standards 150.0(m)1. UL Ratings

Air Conditioning Contractors of America

Your Guide to Buying an Energy-Efficient Central Air Conditioner

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

How to Measure HVAC System Airflow

Heating, Ventilation and Air-Conditioning (HVAC)

Specification of Energy-Efficient Installation and Maintenance Practices for Residential HVAC Systems

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

Glossary of HVAC Terms

HVAC System Installation & Best Practices in New Construction. Anthony Stamatopoulos ACI New Jersey

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

Contract for Weatherization Management Address City & State

Below are detailed instructions for using the EMS load calculator.

Home Energy Evaluation Report

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Advanced Strategy Guideline: Air Distribution Basics and Duct Design

Get the FACTS about SEER and Deliver Better Customer Value

Key energy-efficient features of your new home

Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Duct Design. Presented by Dave Janquart

THREE. Heating and Cooling

Guidelines for Complying with BPI s Technical Standards for the Air Conditioning and Heat Pump Professional

Home Performance with ENERGY STAR. Evaluation Report

Center for Energy Education Laboratory

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

HVAC Systems: Overview

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

Element D Services Heating, Ventilating, and Air Conditioning

Fan Applications & System Guide

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Chapter Eight RESNET Standards

HVAC Code Requirements

!"#$%&'!(()*)#"+,, -#.+)"%,."/,0112)"%3,

2014 British Columbia Building Code Changes

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

HVAC Calculations and Duct Sizing

AABC Specifications for Testing and Balancing HVAC Systems

WHOLE-HOUSE VENTILATION SYSTEMS

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Blower Door Testing by David Keefe

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

Exhaust Calculation Booklet

HV AC CODE CHECKLISTS

Basics of HVAC Cleaning

Air-Source Heat Pumps

SAM HOUSTON STATE UNIVERSITY

2016 HVAC Test and Repair Application Specifications

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

Green Built Texas Protocol v3 Project Summary and Checklist, One and Two Family New Construction

air conditioners how to choose a cooling system

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Before You Start an Energy Efficiency Retrofit The Building Envelope

SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322)

4 Installation Requirements

Single Package Vertical Air Conditioners. Vert-I-Pak

Ductless Heat Pumps. Gary Nordeen January

DUCT DESIGN FOR THE TIME CONSTRAINED WORLD

DRYER VENTING SPECIFICATIONS DRYER SAFETY

2009 IECC Update. Scope. Content. International Energy Conservation Code

Chapter Seven RESNET Standards

White Paper: Residential HVAC Split System Basics

Glossary of Heating, Ventilation and Air Conditioning Terms

Schedule of Work Experience (OJL) and Training considered necessary to develop a skilled and productive worker.

ASTACEA4 Inspect complex/central air conditioning systems

RELEASE NOTES EG USA 3.0.0

Evaluate, Clean, and Tune Guidance

READ AND SAVE THESE INSTRUCTIONS

FIRE DAMPER APPLICATION GUIDE

Diagnostics for Mobile Homes: HVAC

Minneapolis Duct Blaster

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

Transcription:

September 2003 Retrofitting Existing Ducted Systems GasNetworks HVAC Heating Professionals Fall Conference September 18, 2003 Rick Karg R.J. Karg Associates rjkarg@karg.com Topics Addressed in Session Ductwork sizing discussion. Ductwork Specification: Consortium for Energy Efficiency (CEE). Tools for duct design and commissioning. Some duct installation details. Analysis of existing ductwork. Ductwork trouble-shooting. 2003 R.J. Karg Associates 2 Some Basics of Duct Design and Installation Ducted Distribution 3 See Handout 2, Page 1 4 Good Ducts Start With Good Design Design - yeah, right! What constitutes design is usually a mix of afterthought, what happens to be on the truck at the moment, and the need to get the job done quickly. Duct Design Objective Duct delivery system provides year-around comfort with: Efficiency, Little noise, No hazards to occupants, Little maintenance. 5 6 Rick Karg, R.J. Karg Associates 1

September 2003 A Well Designed Duct System Properly balanced. Look good. Be inexpensive to install. Help create a comfortable environment. Be very quiet while air handler is operating. Be economical to operate. Proper insulation, tight ducts, no pressure imbalance. Be healthy for occupants (e.g., from pressure imbalances). Be easy to maintain. Low Noise Levels are Important See Handout 2, Page 2 7 8 Duct Design Rules Place air handler in central location. Plan for symmetrical duct system. Keep duct runs short. Support ducts properly. Use minimum number of fittings. Keep aspect ratio low. Select registers properly. Install return in each room having a working door. Etc. Duct System Pressures See Handout 2, Page 3 9 See Handout 2, Page 4 10 Measuring Temperature Rise & Calculating CFM Design Standard is Manual D Available from ACCA 2800 Shirlington Road, Suite 300 Arlington, VA 22206 (703) 575-4477 www.acca.org See Handout 2, Page 5 11 12 Rick Karg, R.J. Karg Associates 2

September 2003 Manual D Procedure Calculate DHL/DCL (Manual J, ACCA). Select blower (Manual S, ACCA & Man. Data). Determine External Static Pressure (ESP) from manufacturer s data. Determine device pressure losses (DPL) that are added to distribution system. Determine Available Static Pressure (ASP). ASP = ESP DPL (Equal to about 0.2 WG, limits of range are 0.10 to 0.35 WG). Manual D Procedure (con.) Plan location of registers and grilles (Manual T). Determine the greatest Total Effective Length (TEL) value for the duct system, supply and return sides. Include measured length and fitting equivalent length. Calculate Friction Rate design value (FR). FR = (ASP x 100)/TEL, or use friction chart. Friction rate should be between 0.06 and 0.18 WG/100 feet of duct. See Handout 2, Pages 6-10 13 See Handout 2, Pages 6-10 14 Manual D Procedure (con.) Calculate heating and cooling airflow factors. HF = (blower CFM)/(Design heating load) CF (blower CFM)/(Sensible cooling design load) Calculate CFM for each register (room). Room CFM = HF or CF x Room DHL Size branch ducts and trunks with use of duct calculator or friction chart. Check velocity. Select registers and grilles (Manual T, ACCA). Balance system with branch balancing dampers. Ductwork Specification 1 Quick Reference for HVAC Installation Specification Ducts and Air Handlers Section/Specification Element Specification Element Potential Benefits Verification Test or Method 5. Ducts and Air Handlers 5.1 Duct Location - All ducts should be located within the conditioned spaces - Reduces conduction and air-leakage - Visual inspection. whenever possible. losses. - No ducts in exterior wall cavities. - Always install ducts, don t use building cavities. - No panned floor joists. - Don t use crawl spaces as plenums. 5.2 Duct System Design - Use Residential Duct System, Manual D, 1995 edition or later. - If ducts are not sized large enough to - Residential Duct System, permit adequate airflow, system efficiency Manual D, 1995 edition or can be adversely affected. later. 5.3 Allowable Duct Leakage, New Air - 25 CFM of leakage for every 400 CFM of measured airflow, or - Can save 15% in energy costs per year for - Tests for Ensuring Proper Air Distribution Systems - The sum of supply and return leakage divided by air handler new systems. Handler Airflow 3.13 and 4.9. fan flow shall be a maximum of 6%. - Total Duct Leakage and Percentage Duct Leakage Test 5.13.1. 5.3 Allowable Duct Leakage, Existing Air - 40 CFM of leakage for every 400 CFM of measured airflow, or - Can save 10% in energy costs per year for - Tests for Ensuring Proper Air Distribution Systems - The sum of supply and return leakage divided by air handler existing systems. Handler Airflow 3.13 and 4.9. fan flow shall be a maximum of 10%. - Total Duct Leakage and Percentage Duct Leakage Test 5.13.1. 5.4 Duct Sealing Materials and Methods - Refer to Duct Installation and Sealing Specification. - Use of the proper materials and methods - Visual inspection. extends the life of the ducted system, retaining duct efficiency. 5.5 Insulation, New and Existing Installations - Follow insulation manufacturer s recommendations. - Duct insulation slows heat transfer, - Visual inspection. - Refer to Duct Installation and Sealing Specification making the ducted distribution network more efficient. 5.5.2 Insulation, New Installations - No insulation required for ducts in conditioned spaces, except - Duct insulation slows heat transfer, - Visual inspection. to prevent condensation. making the ducted distribution network - In unconditioned spaces a minimum R-value of 6 is required. more efficient. - Ducts located on the exterior of building require a minimum R- value of 8. 5.5.3 Insulation, Existing Installations - No insulation required for ducts in conditioned spaces, except - Duct insulation slows heat transfer, - Visual inspection. to prevent condensation. making the ducted distribution network - In unconditioned spaces a minimum R-value of 6 is required. more efficient. - Parts of ductwork that are not accessible do not require insulation. - If ducts are already insulated to R-4 or greater, no additional insulation is needed. - Ducts located on the exterior of building require a minimum R- value of 8. See Handout 2, Pages 6-10 15 See Handout 2, Pages 11-16 16 Ductwork Specification 2 Quick Reference for HVAC Installation Specification Ducts and Air Handlers (continued) Section/Specification Element Specification Element Potential Benefits Verification Test or Method 5. Ducts and Air Handlers (continued) 5.6 Room Pressure Imbalances - While air handler is operating and house is closed up, pressure - High-pressure differences between spaces - Room Pressure Imbalances differences between 1) closed room and the outdoors and 2) the in a house and the outdoors can increase air Test 5.14.1. main body of the house with all the interior doors closed should leakage to and from the outdoors. be no more than 0.01 inches water gauge (3 Pascals), positive or Decreasing these pressures can save energy. negative. - Room depressurization may cause hazardous back drafting of combustion gases. 5.7 Selection and Location of Supply Registers - At least one supply-air register should be installed in each - Proper selection and placement of supplyair - Visual inspection. conditioned room. registers can increase occupant comfort. - Each register should be able to handle the required heating and cooling CFM and air velocity. - Maximum velocity of 700 feet per minute. - Select for proper throw, drop, and spread. 5.8 Selection and Location of Return Grilles - Return-air grilles should be located to provide pressurebalanced - The proper placement of return-air grilles - Visual inspection. air circulation during air handler operation. minimized indoor pressure imbalances - Max. velocity of 500 feet per minute. during air handler operation, thereby conserving energy lost due to forces air leakage. 5.9 Duct Support - Ducts should be supported so as to prevent dislocation or - Supporting ducts in a proper and durable - Visual inspection. damage. fashion helps maintain duct system - Refer to Duct Installation and Sealing Specification. efficiency. 5.10 Volume Dampers - Supply branch ducts should be equipped with volume dampers - A properly balanced duct system increases - Visual inspection. to allow for manual balancing of distribution airflow. occupant comfort and reduces occupant - After installation, the ducted system should be properly complaints. balanced. 5.11 Access for Installation and Maintenance - Adequate clearance should be provided on all sides of the - Adequate clearance for the maintenance of - Visual inspection. equipment to allow for easy access for periodic maintenance. important equipment components allows - All doors leading from the mechanical room to the outdoors the equipment to be serviced properly and should be large enough to allow easy passage of equipment. regularly, thereby ensuring the maintenance of maximum equipment efficiency. 5.12 Maintenance Items - Inspect the following items at servicing: - Proper maintenance of the forced-air - Visual inspection. - Filters, distribution system will help retain system - Duct obstructions and debris, efficiency. - Duct leaks and disconnections, - Volume dampers, - Duct balancing, - Duct insulation, and - Room pressure imbalances. Tools for Duct Design & Testing Page See Handout 20 2, Pages 11-16 17 18 Rick Karg, R.J. Karg Associates 3

September 2003 Duct Calculator From ACCA Duct Calculator From ACCA See Handout 2, Page 45 Also Page 36 Friction Chart See Handout 2, Page 45 19 20 Duct Blower Trueflow Air Meter The Energy Conservatory Duct Blaster The Energy Conservatory 21 22 Digital Manometer Duct Leakage Testing If you don t test, you don t know. Duct leakage testing is essential to producing comfort and efficiency. 23 24 Rick Karg, R.J. Karg Associates 4

September 2003 Blower Door Pressure Pan & Flowbox A blower door is often needed for duct leakage testing. 25 26 Measuring Air Flow The volumetric capture bag. AKA garbage bag. Works by timing how long it takes to fill a known volume with air. 27 See Handout 2, Page 17 28 Room-to to-room Pressure Testing with Ducted Distribution Room-to-Room Pressure Differences - 1 Occupants live within the ducted system. Return air paths are critical to a good airflow. A closed door can serve as an air distribution damper!! 29 30 Rick Karg, R.J. Karg Associates 5

September 2003 Room-to-Room Pressure Differences - 2 Pressure difference across door should be 3 Pascals or less. Determine with digital manometer. Relieve higher pressures by: Undercutting doors. Installing a grille in door or wall. Installing a jump or transfer duct. Adding a return to the problem room. Some Duct Installation Details 31 32 Try to Keep Duct Inside Inside vs. outside the thermal envelope of the house. If the ducts are outside, more work is required to make them efficient. Do not use duct tape on ducts! But, it s really good for many other needs. 33 34 Ducts Should Be Permanently Tight Love that Duct Mastic Mechanically Fastened Sealed with Mastic Pay attention to gores 35 36 Rick Karg, R.J. Karg Associates 6

September 2003 Provide Ability to Adjust Airflow Temperature Measurements Balancing damper handle If duct are large enough, airflow can be adjusted to met individual comfort levels or differences in heating and cooling loads Simple temperature readings can help locate leaks or loss of cooling or heating energy in a ducted system. Cooling coil Cooling duct 37 See Handout 2, Page 18 38 Impact of an Air Handler What happens to air leakage as a result of the closed bedroom door? What if a return is installed in the basement return trunk? What if the supply trunk leaks to the outdoors? Multiple Returns are Essential Return air paths are critical to a good duct system. A closed door can serve as an air distribution damper!! See Handout 2, Page 19 39 40 Return Side Retrofit Analysis of Existing Ductwork See Handout 2, Page 20 For a furnace/ac to operate at maximum efficiency and capacity, the volumecarrying capacity of the return air must equal that of the supply air. However, many residential systems are undersized on the return side, causing pressure imbalances and discomfort. To balance the return and supply sides, additional return grilles and ductwork might have to be added. 41 Source: Journal of Light Construction, 2/94, page 49 42 Rick Karg, R.J. Karg Associates 7

September 2003 Analysis of Existing Ductwork 1 Interview occupants about thermal comfort of existing system. Ask such things as: Uncomfortable rooms. Excessive noise. Frequent cycling of air handler blower. Analysis of Existing Ductwork 2 Inspect air handler and ductwork for such things as: Anticipator setting. Duct leakage. Restricted returns. Panned floor joists. Ducts in unconditioned spaces. Balancing dampers. See Handout 2, Pages 21 22 and 23 24 (Manual D) 43 See Handout 2, Pages 21 22 and 23 24 (Manual D) 44 Analysis of Existing Ductwork 3 Do technical appraisal of duct system and equipment: Temperature rise. Static pressure measurements. Blower CFM. Analysis of Existing Ductwork 4 Do pressure testing of existing system: Room-to-room pressures. Duct leakage testing Blower door. Duct blower. See Handout 2, Pages 21 22 and 23 24 (Manual D) 45 See Handout 2, Pages 21 22 and 23 24 (Manual D) 46 Analysis of Existing Ductwork 5 Now, Perform the Work! Determine strategies for duct repair: Write down possible problems. Check trouble-shooting list. Determine required alterations to furnace/ac and ductwork. Decide on consumer education strategies. See Handout 2, Pages 21 22 and 23 24 (Manual D) 47 48 Rick Karg, R.J. Karg Associates 8

September 2003 Duct Trouble- Shooting Tables Ductwork Troubleshooting 1 49 See Handout 2, Page 25 50 Ductwork Troubleshooting 2 Ductwork Troubleshooting 3 See Handout 2, Page 26 51 See Handout 2, Page 27 52 Ductwork Troubleshooting 4 Remainder of Handout 2 Duct design and analysis: equations, etc (pg 29 32). Effective length diagrams (pg 33). Effective length of fittings (pg 34). Friction rate chart (pg 35). Friction chart (pg 36). Round to rectangular conversion chart (pg 37). Air velocity chart (pg 38). Manufacturer s register info. (pg 39). Duct sizing example, Manual D (pg 40 43). ACCA ordering information (44 46) See Handout 2, Page 28 53 54 Rick Karg, R.J. Karg Associates 9