Standard systems. HVAC Products

Similar documents
OZW30. Central Unit SYNERGYR

Engineering and service software For KNX and LPB plants

Operating Software Service Tool

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Heating Controller. Building Technologies HVAC Products

Synco Central Communication Unit OZW771 Basic Documentation

Building Technologies

Temperature & Humidity SMS Alert Controller

Product Release LPB Web server V3.0. Infrastructure & Cities

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Building Technologies. Siemeca AMR

Remote Meter Reading via M-Bus by Klaus-Peter Richter, Energy Management Product Manager GOSSEN METRAWATT GMBH

OZW V2.0. Web server. Synco TM, Synco TM living

NC-12 Modbus Application

GSM ATT Modules Simply effective remote control

Documentation. M-Bus 130-mbx

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

HYDRUS ULTRASONIC METER

RRV934. Multi-controller. Synco living

PCS0100en Persy Control Services B.V. Netherlands

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

OZS Web server. For LPB/BSB plants

OZW672...V5.2. Web-Server. For LPB/BSB plants

ABB i-bus KNX Fan Coil Controller FC/S 1.1

OZW V4.0. Web server. For Synco TM, Synco TM living

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

3873P01. Room controllers. For fan-coil applications FC-10, FC-11, FC12 with Konnex bus communications (S-mode and LTE mode)

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Web-Server OZW V5.2

Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Electronic Control Devices The European Product Catalogue 2007

VAV compact controller KNX / PL-Link

VAV compact controller KNX / PL-Link

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

ABB i-bus EIB Logic Module LM/S 1.1

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

HVAC central apartment unit with consumption data acquisition

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Operating Instructions

Communication in building automation

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

IntesisBox KNX Mitsubishi Heavy Industries AC

YZP : SAUTER Vision Center

RS232 Programming and Troubleshooting Guide for Turbo Controls

Modbus and ION Technology

Permissible ambient temperature Operation Storage, transport

Modular I/O System Analog and Digital Interface Modules

PRODUCT LIST Facility DDC Access WebXL DDC

Industrial Networks & Databases

Passion for Innovation

PD 100A. Printing data system

Digital input modules

ABB PSPS Erich Steinmann; Generator control-2013

Duct Humidity Transmitter

SMS GSM Alarm Messenger

Remote Monitoring and REC 501 Control Unit Product Guide

Electronic Control Devices The European Product Catalogue 2007

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Rev GSM base station. Installation instructions

M-Bus-Logger Data Logger

3466 Building Energy Management Training Systems

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Inwall Room Temperature Unit

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

AMTRON E-30 Compact heat and cooling meter

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Voltage Regulator SPAU 341 C. Product Guide

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

Efficient remote access to machines and plants with SIMATIC

2.24. Pump Controller 704. Data Sheet

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

TX OPEN RS232/485 module

HVAC central apartment unit with consumption data acquisition

Product Information Fire alarm panel 8000 C

Other 555 based and 8051 based projects...

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Disturbance Recoder SPCR 8C27. Product Guide

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

NUEVO With ::::::::::::::::

40.3. Control Relays and Timers

SNMP Web Management. User s Manual For SNMP Web Card/Box

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

T Substation Maintenance and Commissioning Test Equipment

The multi-functional integrator Supercal 531

Programmable Controller G Series. New. Models

Quick Connect. quick - simple - efficient.

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Transcription:

3 Standard systems Standard systeme for: heating, ventilation or air conditioning Synco KNX Heating plants SIGMAGYR, AEROGYR District heating and metering SIGMAGYR, SONOHEAT, Siemeca Control and energy cost SYNERGYR Standard PC software ACS7.. consist of: Service software Operating software Alarm software Batchjob software

Summary of fields of applications Standard systems for: Heating, Heating plants District heating Control and ventilation or and meter readout energy cost air conditioning allocation Main components Synco SIGMAGYR SIGMAGYR SYNERGYR AEROGYR SONOHEAT Siemeca Heating controllers Synco RMH760 SIGMAGYR -Series SIGMAGYR -Series SIGMAGYR -Series 1) RVL400-Heating controllers RVD200-District heating controllers RVP300-Heating controllers RVP500-Energy manager RVD200-District heating contr. Ventilation and Synco RMU710 AEROGYR RWI65 air conditioning Synco RMU720 controllers Synco RMU730 Room controllers Synco RXB WRV-Control and heating cost allocation vaves Energy meters AEW2.1 Pulse adapter SONOHEAT Heat meters WRV-Control and heating Siemeca Heat meters cost allocation valves Siemeca AMR-Radio system AEW2.1 Pulse adapter AEW21 Pulse adapter Communication bus KNX (Konnex) LPB (Local process bus) M-Bus (Metering bus) Batibus Max. bus extansion 2) 1 000 m/700 m 2 500 m/1 200 m up to 10 000 m (without repeater) 2 500 m/600 m Speed 9 600 baude 4 800 baude 300 9 600 baude 4 800 baude Max no. comm. devices 3) 24/64 16/40 /700 / 102 4) Process data exchange No Central data readout System: OCI600 OZW10 Communication central unit OZW771 OCI611.. OZW111 OZW30 Software ACS7.. ACS7.. ACS7.. ACS30 Service tool OCI700.1 OCI700.1 OCI700.1 (for SIGMAGYR ) AZW30/ACS30 1) For the load compensation and the outside temperature transmission 2) Summary cable length/distance to the furthest device 3) With decentralized/centralized bus power supply 4) 96 (user units) and 6 meters (general) 3-2

Standard system for heating, ventilation or air conditioning Synco Low engineering system to easily build complex applications with flexible and modular combinations of standard controllers Synco 700. Standard Systems for HVAC plants are capable to be remote operated and can generate alarms to service centers. Full control without engineering. Bus standards for communications in buildings were originally designed for specific disciplines. The common bus standard Konnex (KNX) was developed by the associations responsible for the 3 bus technologies EIB, Bati- BUS and EHS. This standardization process supports the trend towards the «smart home» in which various plants from the fields of HVAC, lighting and security technology are integrated in a common communications network. The Konnex bus (KNX) uses a network structure derived from the European Installation Bus (EIB). The technical key features are the following: 2-core bus cable, twisted pairs, no shielding required Distributed bus power supply (the Synco 700 controllers supply the bus power) Compatible with EIB The new standard is based on the following principles: Flexibility in the definition of functions for the devices installed in the network Interworking in the same communications network between products from widely differing manufacturers All products with Konnex certification comply with the Konnex standards. Konnex is backward-compatible with EIB (Konnex/EIB devices exclusively in S-mode). 3 OZW771 Communication central units OZW771 Mini telephon gateway Device versions OZW771.04 OZW771.10 No. of comm. devices 1) 4 10 Digital imputs (potential free) 2 As alarm input As counter (operating hours) No Digital output None Operation LED Bus power supply No Alarming Max. telephon no. s 2 ACS Alarm via PC Fax With SMS via GSM Pager With SMS via GSM SMS Printer No e-mail With SMS via GSM General device data Operating voltage AC 230 V ±10 % Frequency 50/60 Hz Power consumption 5 VA Degree of protection IP30 2) 1) Synco controller series 700, RXB, QAW740 2) IP20 without terminal covers 3-3

Standard System for heating plants SIGMAGYR, AEROGYR Low engineering system to easily build complex applications with flexible combinations of standard controllers SIGMAGYR Series RVL400, SIGMAGYR Series RVP300, SIGMAGYR Series RVD200 and AEROGYR RWI65. Standard Systems for heating plants are capable to be remote operated and can generate alarms to service centres: Full control without engineering. OCI600 OCI611 Communication central units OCI600 OCI611 Comm. central unit Mini telephon gateway Device versions OCI600 OCI611.01 OCI611.05 OCI611.16 No. of comm. contollers 16 1 5 16 No. of external I/0 modules Digital input 1) 4 Digital output 2) 4 No. of external pulse inputs 3) 6 No. of external temp. inputs 4) 2 Digital inputs (potential free) 4 2 As alarm input As counter (operating hours) No Digital outputs 2 (max. AC 24 V) None Operation LCD, Operating cards LED Bus power supply No Alarming Max. telephon no. s 4 2 ACS-Alarm via PC Fax With SMS via GSM Pager With SMS via GSM SMS Printer No e-mail No With SMS via GSM Offline trend funktion 6) No General device data Operation voltage AC 24 V AC 230 V ±10 % Frequency 50/60 Hz 50/60 Hz Power consumption 8 VA 5 VA Degree of protection IP40 IP30 5) 1) DOE4IN 2) DOE4RE 3) AEW2.1 with 2 pulse inputs 4) QAB30.600 with 2 temperature inputs 5) IP20 without terminal covers 6) Together with the memory card 3-4

Standard System for district heating and meter SIGMAGYR, SONOHEAT, Siemeca Heat metering and billing system with M-bus, acquisition of heat and water consumption and remote supervision of controls. M-bus central unit for central readout in extensive heat distribution networks and apartment blocks and terraced houses. 3 OZW10 OZW111 Communication central units OZW10 OZW111 Communication central unit Mini telephon gateway No. of comm. devices Up to 700 5 Digital alarm input(potential free) 4 2 Digital alarm relais 1 None Operation LCD, Operating card LED Bus power supply No 1) M-Bus support Adressing Primary und secondary Primary und secondary Baud rate 300, 2400, 9600 300, 2400 Max. Cable extension 2) 10'000 m / 10'000 m 3) 500 m / 100 m Alarming Max. telephone no. s 4 2 ACS Alarm via PC Consumption data Data storage No Read out via RS-232 Read out via memory card None General device data Operating voltage AC 24 V AC 230 V ±10 % Frequency 50/60 Hz 50/60 Hz Power consumption 8 VA 5 VA Degree of protection IP40 IP30 4) 1) Bus power supply WZC-P60 or WZC-P250 necessary. Using the bus power supply WZC-P250 a network extension with repeater WZC-R250 is possible. 2) Sum. cable lenth/distance to remotest device 3) Point to Point connection 4) IP20 without terminal covers 3-5

Standard System for control and energy cost SYNERGYR Heat metering and billing system with integrated room temperature control, especially for new apartment blocks that use horizontal piping. Central acquisition of water and heat at the heating inlet to the apartment. Following versions are available: Comfort: Heat metering system with individual room control. Eco: Heat metering system with integrated reference room control. Standard: Proper heat metering system without room temperature control. 1 Control and heating cost allocation valve WRV.. 2 Room unit QAW10 3 Room unit QAW20 4 Pulse adapter AEW2.1 5 Central unit OZW30 6 Memory card ALC30.128 7 Conduit box ALW30 8 Remote temperature detector QAW44 (for use with the QAW20) OZW30 Communication central units OZW30 Communication central units No. of comm. devices Up to 96 (user units) and 6 meters (general) Digital inputs 2 as counter or alarm inputs 2 as fixed alarm inputs Digital alarm relais 1 Operation LCD, Operating cards Bus power supply Alarming Max. telephon no. s 2 ACS Alarm via PC Consumption data Data storage Read out via RS-232 Read out via memory card Data exchange With LPB controllers General devices data Operating voltage AC 24 V Frequency 50/60 Hz Power consumption 10 VA Degree of protection IP40 3-6

Software tools ACS7..-, Operating, service, alarm and batchjob software PC software for the remote operation, monitoring and commissioning of heating, ventilation and district heating plant and remote readout of consumption data. (Windows version) Remote management with the OZW771 central communication units: Remote operation and monitoring of HVAC plant whose devices (controllers, RXC room controller and room units) are connected via KNX TP1 (Konnex) Bus. Remote management with the OCI600 and OCI611 central communication units: Remote operation and monitoring of heating plant whose devices (controllers, pulse adapters, temperature sensors/adapters, digital input modules and relay modules) are connected via LPB (Local Process Bus) Remote management with the M-bus central units OZW10 and OZW111: Remote operation and monitoring of M-bus-compatible devices (controllers and meters) in community and district heat substations. Acquisition of consumption data of M-bus-compatible meters for consumption cost billing. Acquisition of consumption data from radiobased consumption meters of the Siemeca AMR system, transmitted to the M-bus central unit OZW10 via the Mbus interface of the WTT16 network node. Diagnosis and commissioning of LPB controllers with OCI700 service interfaces Diagnosis and commissioning of KNX controllers with OCI700 service interface 3 Operating software Application Plant overview Remote operation and parameterization Troubleshooting Meter readings Properties Device-oriented operation Extended data access Standard functions Low engineering (plug & play) User can customize the user interface Applications Plant diagram: Fast checking of plant parts Plant overview Standard graphics for controllers with applicationspecific plant diagrams: One graphic with predefined data point display for each device type and for each application. Definition of user-defined graphics: Based on standard graphics Based on own graphics in bitmap format Display of additional data points and information. Links to other graphics 3-7

Software tools Pop card: Checking of device status Checking and changing of settings One standard pop card per device type Application-oriented structure of the pop card pages Several user-defined pop cards per device type Change between standard and user-defined pop card Online-/Offline-Trend: Plant optimization Verification of time response Simultaneous logging of data points for several devices Online visualization of the logged data in the online trend Automatic saving of the logged data Save, load, and export of the logged data Commissioning report: Saving of the commissioning state of one or several devices The data to be saved is predefined for each device type Application-oriented visualization of saved data Save and export of commissioning reports File transfer: Read and save the billing data saved in the OZW10 for devices on the M-bus system Read the alarm history of the OCI600 Read data of the communication stations' memory card Formatting of memory cards Parameterization: Creating standard parameter sets Compare parameter settings Remote adjustment of parameters Track parameter changes Several parameter sets per device type Save, load, and export parameter sets 3-8

Software tools Alarmsoftware Application Receive alarm annunciations/messages and system reports Archive alarm messages Print messages received Supplement alarm messages by additional information Properties Option to customize the display Export alarm messages 3 Batch job software Application Time control of parameters (setpoints, etc.) in heating plants: e. g. for load management Time controlled registration of selected process and consumption values in heating plants, community and district heating plants: e. g. for further data analysis in separate, user-specific programs Cyclical transfer of billing data with consumption data on M-bus capable meters to the PC Properties Actions on data points of any devices in the system Sequential and prioritized task execution 3-9

Software tools ACS7.. Standard packages ACS7.. is available in different standard variants that can be ordered via ASN directly, and that are optimized to certain user groups and plant sizes: 3-10