Energy measurement. Instantaneous parameter measurement

Similar documents
Polyphase kwh Electricity Meter

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Energy Management Energy Meter Type EM23 DIN

KÖHLER ELEKTRİK SAYAÇLARI SAN. VE TİCARET A.Ş. ELECTRONİC ELCTRIC ENERGY METER TECHNICAL DATA

User Manual Single Phase Energy Meter

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Quick Connect. quick - simple - efficient.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Voltage Regulator SPAU 341 C. Product Guide

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

HYDRUS ULTRASONIC METER

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Power Meter Series 700

A project to optimise quality and energy efficiency must include metering

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

SNMP Web Management. User s Manual For SNMP Web Card/Box

Temperature & Humidity SMS Alert Controller

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Elster Metering Systems. EC Directive 2004/22/EC

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Duct Humidity Transmitter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Indoor / Outdoor Antenna

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Dale Pennington, Managing Director, Utiliworks Consulting LLC, New York, USA

User's Guide. Integrating Sound Level Datalogger. Model Introduction

AS220 Single phase Smart Meter. Product manual

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

3-phase, bidirectional energy meter

Preset Counter signo 721

Solar Controller / Battery Charger User s Manual

Multifunction devices

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

NC-12 Modbus Application

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Digital and Analog I/O

MOUNTING AND OPERATING INSTRUCTIONS

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Applications. diris_826_a_1_gb_cat

AZ DISPLAYS, INC. LCD MODULE SPECIFICATION MODULE TYPE : AGM1616A

O C M III. Open Channel Flow Monitor

Fingerprint Based Biometric Attendance System

Thyristor-controlled power supplies and battery chargers

Main catalog. Electricity meters For modular enclosures and DIN rail

Safety automation solutions

Maximum Demand Control

Counter for Energy. We make energy measurable and secure your future.

Flexible Counter Series in DIN size 24 x 48 mm

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Installation and operating instructions

ST800K-U Optical Power Meter. User Manual V1.0

Contents & P-LCD Modules Cross Reference Table

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

How To Use A Corona Mdi 110

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

HERZ-Thermal Actuators

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Digital input modules

Electrical Measuring Instruments

8051 MICROCONTROLLER COURSE

Impedance 50 (75 connectors via adapters)

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Safety Relays ESM/ESM-F

PCS0100en Persy Control Services B.V. Netherlands

Disturbance Recoder SPCR 8C27. Product Guide

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

PD 100A. Printing data system

ABB i-bus EIB Logic Module LM/S 1.1

Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters

OZW30. Central Unit SYNERGYR

Smile. The All-In-One Heating Controller

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

MGL x64 Graphic LCD Module User Manual

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Transcription:

E3000-0 Three Phase Multi-function Meter The E3000-0 is a 3P4W multifunctional energy meters. It adopts the advanced technology of LSI (Large Scale Integrated circuit) and digital signal processing. The craftworks of our product are exquisite and the functions provided are comprehensive and client-oriented. The function of E3000-0 meter includes delivered and received active energy metering, LCD display, infrared communication ports, pushed billing with ECC signatures, important parameters modification event log and power outage event log etc. The E3000-0 meter can work with an additional EWM KM, which can gather the instantaneous data from the E3000-0 BM and processes and manages such information. The performance of our product is highly stable, the metering of energy is precise and the operations provided are very convenient and client-oriented. Ite m Standard DIN EN 62053-2 Description Wechselstrom-Elektrizitätszähle r; Besondere Anforderungen, Teil 2: Elektronische Wirkverbrauchszähler der Genauigkeitsklassen und 2 2 DIN EN 62052-3 DIN EN 62056-2 4 DIN EN 62056-6 Wechselstrom-Elektrizitätszähle r - Allgemeine Anforderungen, Prüfungen und Prüfbedingungen, Teil : Messeinrichtungen Elektrizitätszähler, Zählerstandsübertragung, Teil 2: Datenübertragung für festen und mobilen Anschluß Messung der elektrischen Energie Zählerstandsübertragung, Teil 6: OBIS Objekt Identification System Energy measurement Active import and export energy measurement Up to 5 month s history energy data At the time of 00:00 on the first day in one month, the current energy will be frozen and be saved to the history registers. All this history data can be read out via MMS. Instantaneous parameter measurement The instantaneous parameter can be displayed on LCD and be read out via communication. Instantaneous parameter measurements support: Positive and negative active power for total and each phase Voltage and current for each phase - -

Power factor for each phase Frequency Phase angle between the U~U2, U~U3, U~I, U2~I2, U3~I3 Communication There are two optical communication ports in E3000-0 BM. The user interface is on the meter cover, and the D0 interface is at the low side of the meter. The configuration of these two ports is 9600bps, 8N. The D0 interface is used to communicate with the E3000-0 KM. The cycle for the pushing period is two seconds. If the E3000-0 KM sends one connection message to the E3000-0 BM, the E3000-0 BM will start pushing data at once. Otherwise, the E3000-0 BM will send data to the E3000-0 KM every 40 seconds in order to detect whether there s E3000-0 KM present. The user can get or set any supported information from the meter via user optical interface. Digit signature The meter use digit signature for communication data, this crypto algorithm is ECC with 92 bits. The hash value is calculated with SHA-256, FIPS 80-2. The high 24 Bytes of the hash value are used for signature calculation. So the data is very safety and steady when it communication and transmission. Display The meter use dot matrix LCD, and it s with backlight. The meter with the display mode of standard, standard backlight, request, service, dial test, and under each display mode, it have it s own display item and display interval. When the data item displayed, it with OBIS code, unit, and other information. Real time clock The super capacitor can supply 7 days in minimum after at least 24 hours of operation of the meter. The accuracy of the real time is better than 0.5s/day at 20 C environment temperature. When the super capacitor elapsed the clock is set to the time at power failure. The calendar support from the year 2000 to the year 2099, the DST function can be enabled or disabled. For the communication interface, E3000-0 BM also supports the timestamp in the Unix time format. Pulse output The meter can be provided with active pulse output, it s can be used for calibration. Event log The meter can detect current status and record event, with the function of following event detect and record. Last 20 times meter Parameter modify Last 0 times meter Power Outage Last 0 times meter Phase disconnection Last 0 times meter Phase over voltage Last 0 times meter Phase under voltage Last 0 times meter Phase overload - 2 -

Last 0 times meter Phase reversed active energy Last 0 times meter Cover Open Last 0 times meter RTC error Technical data Type Voltages: Nominal voltage U n Voltage range Frequency: Nominal frequency f n Frequency range Currents: Reference current I ref = I b = 0 I tr Maximum current I max Minimum current I min Starting current I st Accuracy: Measurement: Three-phase, 4 wire direct connected active energy meter for domestic customers 3 x 230/400 V 0.8.5 U n 50 Hz 0.98.02 f n 5 A 00 A 0. A < 0.04 A Class B 2 Energy flow directions Cumulated active energy (total import) Cumulated active energy (total export) Calibration Typical power consumption: Voltage circuit active/apparent power Current circuit apparent power Temperature range: +W = +W L +W L2 +W L3 -W = -W L W L2 W L3 Software calibration for the entire life time < W / VA at U n < 0. VA at I ref Operation: -25 C to +55 C no extension modules -0 C to +40 C with extension modules - 3 -

Storage: -40 C to +85 C Enclosure: According to DIN 43857 Material: Recyclable polycarbonate with 0% fibre glass, self-extinguishing to EN 62053-2 Protection class II Protection degree IP 5 Optical test and function indicator: LED (infrared) Pulsating (meter constant) 0,000 pulses/kwh Illuminated Power on, no load current (standstill) Display: Life cycle Com-Module Communication: Interface Data transmission rate Mode (controlled by the Com-Module) Interface to Com-Module Functionality HHU Communication Interface Data transmission rate Mode Dot matrix > 2 years SML Protocol (Residential Profile) Optical 9,600 bps - Push mode - Pull mode Optical (D0) Real time data transfer every 2 seconds Digitally signed billing data transfer every minute On request data retrieval Parameterization and settings Control / monitoring SML Protocol Optical (D0) 9,600 bps Pull - 4 -

Outside dimensions Connection diagram - 5 -