Module 6 - Symbols 6.2 SYMBOLS. Division 01 - General Requirements. -by MasterFormat 2004 Numbers (MF NO) & Symbol Type (Type)

Similar documents
Drawing a Bedroom Floorplan

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

What s New V 11. Preferences: Parameters: Layout/ Modifications: Reverse mouse scroll wheel zoom direction

Diffractive Optical Elements (DOE) for FLEXPOINT Laser Modules

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Perimeter. 14ft. 5ft. 11ft.

Calculating Perimeter

Special Use Commercial Properties

POST AND FRAME STRUCTURES (Pole Barns)

University of Northern Iowa Design Documents Standards. October 2014

The replacement or modification of existing windows shall comply with the following requirements:

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Basic Math for the Small Public Water Systems Operator

Clark County Fire Prevention

Area and Perimeter. Name: Class: Date: Short Answer

Solar Panel Installations

Schematic Design: Quality Management Phase Checklist Project Phase Checklist Series

DATE PERIOD. Estimate the product of a decimal and a whole number by rounding the Estimation

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

12-1 Representations of Three-Dimensional Figures

Layout Tutorial. Getting Started

Area of Parallelograms, Triangles, and Trapezoids (pages )

Kitchen and Bath Design Tutorial

PLAN SUBMITTAL INFORMATION

BOOTH DESIGN RULES NEW!

glass & Glazing Products

Perimeter, Area, and Volume

Chapter 4: The Concept of Area

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Developing Conceptual Understanding of Number. Set J: Perimeter and Area

Area and Circumference

Pizza! Pizza! Assessment

CREATING A 3D VISUALISATION OF YOUR PLANS IN PLANSXPRESS AND CORTONA VRML CLIENT

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Single Family Residential Basement Finish

CHAPTER 3 Drafting Conventions

CAD Standards Guideline For Facility Documentation and Construction Projects

Circumference and Area of a Circle

Residential Building Permits

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Kitchen and Bath Design Tutorial

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

CONSTRUCTION SPECIFICATIONS

Using Excel to find Perimeter, Area & Volume

Installing Window and Door Mouldings

Imperial Length Measurements

City of Riverside Building & Safety Division Phone: (951)

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

WEIGHTS AND MEASURES. Linear Measure. 1 Foot12 inches. 1 Yard 3 feet - 36 inches. 1 Rod 5 1/2 yards /2 feet

Google SketchUp Design Exercise 3

COMMONLY USED RESIDENTIAL BUILDING CODES

Specifications, Product Testing and Terminology

EXHIBIT CONSTRUCTION GUIDELINES

Area of Parallelograms (pages )

Quick Reference ebook

Freehand Sketching. Sections

Residential Adjustments. Overview 4.1

CH. 2 LOADS ON BUILDINGS

How To Build A Basement House

SECTIONALS GUIDE. U-Chaise Sectional* Consists of (L to R): 1 Left-Arm Chaise, 1 Armless Sofa and 1 Right-Arm Chaise

Floorplanner Drawing Manual

SECTION 1 GENERAL REQUIREMENTS

How To Draw In Interior Design

Inv 1 5. Draw 2 different shapes, each with an area of 15 square units and perimeter of 16 units.

Gear Engineering Data. Spur Gear Gear Formulas Drive Selection Horsepower and Torque Tables

COMMONLY USED RESIDENTIAL BUILDING CODES

16 Circles and Cylinders

Standards for Working Drawings

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Roof Tutorial. Chapter 3:

Basic AutoSketch Manual

TeeJay Publishers General Homework for Book 3G Ch 9 - circles. Circles

EXAM GUIDE. Schematic Design. Overview 2. Interior Layout Vignette 3 Sample Passing Solution 5 Sample Failing Solution 6

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

Technical Drawing Specifications Resource A guide to support VCE Visual Communication Design study design

Math Questions & Answers

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

CANING AND RUSH SUPPLIES

Lesson 21. Circles. Objectives

Building Code Clarifications - 7. Fire Resistance

Assignment 3 Floor Plan CAD Fundamentals I Due February 1 Architecture 411

PART 3 MODULE 8 PROBLEMS INVOLVING AREA

Tallahassee Community College PERIMETER

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Everyday Math Online Games (Grades 1 to 3)

PRESERVATION PLANNING ASSOCIATES 519 Fig Avenue, Santa Barbara, CA Telephone (805)

TurboCAD Architectural

General Fire Code Requirements Within Commercial Tenant Spaces

Window Glass Design 5 According to ASTM E 1300

NATIONAL FLOOD INSURANCE PROGRAM (NFIP) SUBSTANTIAL DAMAGE/ SUBSTANTIAL IMPROVEMENT (50% RULE)

digital project V1,R4 Quick Start

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

WFTDA TRACK LAYOUT GUIDE

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

Quality alu LED profiles

3. HERITAGE GRANT APPROVAL 192 MOORHOUSE AVENUE, CHRISTCHURCH

Reference/Training Manual GIZA Technologies

Excerpts from the Canadian National Building Code (NBC)

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Transcription:

Module 6 - Symbols 6.2 SYMBOS -by MasterFormat 2004 Numbers (MF NO) & Symbol Type (Type) Division 01 - General equirements MF NO DESCPTON TYPE SYMBO DV 01 GENEA EQUEMENTS 01 00 00 column, circular symbol O 01 00 00 column, beam symbol O 01 00 00 column, square symbol O 01 00 00 and T 01 00 00 at T 01 00 00 center line T 01 00 00 degree(s) T 01 00 00 divide by, per T 01 00 00 dollar (USD) T 01 00 00 equals, equal to T 01 00 00 foot, feet T 01 00 00 greater than T 01 00 00 greater than or equal to T 01 00 00 inch(es) T 01 00 00 less than T 01 00 00 less than or equal to T 01 00 00 minus T 01 00 00 multiply by, by T 01 00 00 number, pound T

01 00 00 percent T 01 00 00 plus T 01 00 00 plus or minus T 01 00 00 property line T elevation indicator, fine line, 4mm (5/32") diameter with lines extending 1mm (1/32") beyond circle boring indicator elevation indicator, finish monument indicator property corner indicator, existing, 5 mm (3/16") diameter, property corner indicator, new temporary ground point indicator, existing, 4 mm (5/32") square, temporary ground point indicator, new center line indicator; thin line, 2 mm (5/64") dash, 2 mm (5/64") space contract limit line; wide line with dot, 1 mm (1/16") diameter dot, 3 mm (1/8") space demolition line; medium line, 4 mm (5/32") dash, 2 mm (5/64") space existing to remain line; thin line features above line indicator; thin dashed line

fire resistive rated line, 1 hour; fine line, 14 mm (9/16") repeat fire resistive rated line, 2 hour; fine line, 12 mm (29/64") repeat fire resistive rated line, 3 hour; fine line, 8 mm (21/64") repeat fire resistive rated line, 4 hour; fine line, 7 mm (9/32") repeat fire-rated, smoke barrier line, 1 hour; fine line, 2.5 mm (3/32") text, 3.2 mm (1/8") space, 14 mm (9/16") repeat fire-rated, smoke barrier line, 2 hour; fine line, 2.5 mm (3/32") text, 3.2 mm (1/8") space, 12 mm (29/64") repeat fire-rated, smoke barrier line, 3 hour; fine line, 2.5 mm (3/32") text, 3.2 mm (1/8") space, 8 mm (21/64") repeat fire-rated, smoke barrier line, 4 hour; fine line, 2.5 mm (3/32") text, 3.2 mm (1/8") space, 7 mm (9/32") repeat hidden features line; thin line new line; medium line property line; wide line, 5 mm (3/16") dash, 3 mm (1/8") space smoke barrier line; fi ne line, 2.5 mm (3/32") text, 14 mm (9/16") repeat

break, round (user defines size) break, straight (see section indicators, building, with break standards) MF NO DESCPTON TYPE SYMBO detail indicator, dashed circle, 2.5 mm (3/32") text, detail indicator, dashed rectangle, 2.5 mm (3/32") text, detail indicator for small conditions, 45 degree arrow, 2.5 mm (3/32") text, medium line dimension line: continuous, thin line with medium line for terminator dimension line: continuous, thin line with medium line for slash terminator or thin line with 3:1 filled arrows for arrow terminators,

door opening/borrowed light identifier, 2.5 mm (3/32") text, medium line, drawing block title, elevation indicator, exterior, 16 mm (5/8") diameter elevation indicator, interior, multiple view, 16 mm (5/8") diameter; for two, three or four views elevation indicator, interior, single view, 16 mm (5/8") diameter furniture, fixture, & equipment indicator, medium line, 1:5000 1:2000 1:1000 1:500

1:200 1:100 1:50 1:30 1:20 1:10 1:5 1:2 1:1 1" = 1000'-0" 1" = 500'-0" 1" = 200'-0" 1" = 100'-0" 1" = 50'-0" 1" = 40'-0" 1" = 30'-0" 1" = 20'-0" 1" = 10'-0" 1/16" = 1'-0" 3/32" = 1'-0" 1/8" = 1'-0" 1/4" = 1'-0" 3/8" = 1'-0" 1/2" = 1'-0"

3/4" = 1'-0" 1" = 1'-0" 1 ½" = 1'-0" 3" = 1'-0" 6" = 1'-0" 1" = 1" identification device indicator, 2 mm (5/64") text, 3 mm (1/8") sides insertion point, 4 mm (5/32") wide/high hidden line keynote indicator, 2.5 mm (3/32") text, 60 degree angles, 6 mm (1/4") high, medium line leader, curved, 3:1 fi lled arrow, 3 mm (1/8") text, medium line leader, straight, 3:1 filled arrow, 3 mm (1/8") text, medium line louver type identifier, = louver, 3 = type, similiar to window type identifier, medium line match line indicator, extra wide center line, 3 mm (1/8") text, medium line,

north indicator, user-defined diameter (optional symbol may be replaced by user-defined north indicator symbol or north arrow) azimuth indicator, 1 inch diameter, medium line, 2.5 mm (3/32) text reference grid indicator with reference grid lines, medium line, revision indicator (shown with revision cloud), room identifier with room name and number, medium line,

room identifier with room name and number, optional finishes A = floor finish type 2 = base finish type C = wall finish type 3 = ceiling finish type section indicators for building with break standards, section indicators for partial building, wall type indicator, medium line,

window type identifier, 2.5 mm (3/32") text, medium line, DENTTY (), NE (), MATEA (M), OBJECT (O), EFEENCE (), AND TEXT (T) SYMBOS National nstitute of Building Sciences An Authoritative Source of nnovative Solutions for the Built Environment 1090 Vermont Avenue, NW, Suite 700 Washington, DC 20005-4950 (202) 289-7800 Fax (202) 289-1092 2011 National nstitute of Building Sciences. All rights reserved.