Dewhot gas geyser manual

Similar documents
E-gas Instant Gas Water Heaters

Gas Instantaneous Water Heater

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Troubleshoot resources for homeowner

Installation Instructions

User's Instructions. Alpha HE CB25/33 and HE SY25

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Operating instructions

Morco House Riverview Road Beverley HU17 0LD

Baxi Combi 80e & 105e

GREENSTAR HEATSLAVE 12/18, 18/25, 25/32

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

San josé OWNER S MANUAL

High Efficiency Boiler Range Technical Guide

1 DESCRIPTION OF THE APPLIANCE

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Operating instructions

HEAVY DUTY STORAGE GAS

orlando OWNER S MANUAL

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

Electric Flow Boiler

Please keep this manual for f uture reference.

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

HeatSource HS1800 Heater

INSTANTANEOUS GAS FIRED

Session 2: Hot Water Supply

This section gives you some helpful information and tips on running your home and the equipment in it.

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

For installation guide see reverse of book

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Endless Hot Water 24/7

Luna 3 Comfort Troubleshooting Guide June 2008

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Combi 30 HE. User s Guide and Important Warranty Information

Mikrofill Ethos Condensing combination boiler


GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Operating instructions

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Safe Method: Gas Safety in Catering Establishments

Commercial Gas Furnace Upflow

High efficiency, cast-iron gas boiler

How to use your Water Heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Response: The combi boiler. Response: The fit anywhere combi

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

CARING FOR YOUR WATER HEATER

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Operators manual Basic water heater

User manual and Installation instructions

Advice for tenants about frozen and burst pipes

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Continuous Flow Water Heaters

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

Fault Finder. A Service Engineers. for Warm Air Heating. Publication No. ZZ April 2015

UDSA - UDSBD unit heater

NAVIEN AMERICA INC FITCH AVENUE

Combi Eco Elite Range. User s Guide and Important Warranty Information

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Vaillant s plain English guide to. simple, concise and precise

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Cooling Capacity CFM in. w.c. (125 Pa)

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

TABLE OF CONTENTS 2 CONGRATULATIONS 3 THE BOSCH STORY 3 PRODUCT OVERVIEW 3 PRODUCT DIAGRAM 4 OPERATING INSTRUCTIONS 5 TROUBLE SHOOTING 6

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

INSTALLATION INSTRUCTIONS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

ECOCIAT. Domestic hot water heat recovery unit

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Technical data. Danfoss DHP-A

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Spare Parts List M96A.24SM/B M96A.28SM/B

BoilerMate SP. benchmark. user instructions A - C L A S S

Transcription:

Dewhot gas geyser manual How to get the best out of your geyser

Safety devices Water over heating protection (75oC) Exhaust over heating (45) Flame out gas cut off Low flow cut off Non return valve Anti frost protection Parameters Gas type, LPG Gas pressure 2 000-2800 pa Solenoid lifetime 300,000 times Water pressure min 0.25 bar Water pressure max 5.0 bar Features Domestic instant water heater with natural exhaust; Water gas linked automatic ignition, No pilot light; Automatic pulse ignition from two standard torch batteries; Stainless steel 30 front panel; LCD temperature gauge; Flame height, gas flow switch; Temperature, water flow rate switch; On & off nob for cold or hot water; Low water pressure starting; Water pressure stabilizing design; Starting indicator light; Hot water output 25~ 6lt 8lt 0lt 2lt 6lt 20Lt Rated input (KW) 2 6 20 24 32 40 Rated output (KW) 0.8 4.4 8 2.6 28.8 36.8 Gas consumption LPG 0.93 kg/hr.24 kg/hr.55 kg/hr.86 kg/hr 2.65 kg/hr 3.0 kg/hr Water flow min 80 lt/hr 240 lt/hr 300 lt/hr 320 lt/hr 360 lt/hr 600 lt/hr Water flow max 360 lt/hr 480 lt/hr 600 lt/hr 720 lt/hr 960 lt/hr 200 lt/hr Flue diameter 90 mm 0 mm 0 mm 0 mm 25 mm 26 mm Dimension (W, H, D) 290*430*30 320*520*50 330*590*50 330*620*50 380*680*80 430*730*80 Packed dimension 350*565*80 385*645*200 395*720*200 395*755*200 436*845*260 485*885*260 Net weight 4.6 kg 6.5 kg 7.2 kg 8.0 kg.5 3.2 kg Gross weight 6 kg 7.5 kg 8.5 kg 9.35 kg 3.5 4.5 kg Page 2 of 2 Page 3 of 2

Q/A Why can I not use a 20lt to run the whole house A 20lt unit runs from 20lt/ min on the cool setting to 0lt/min on the hot. If you are running 8lt/min then the back pressure will switch off the unit. If you are running 0lt then you must have it on the hot setting or it will cut out. Choice of Cylinder or Regulator for units Geyser size 6L, 8L 6L, 8L, 0L 6L, 8L, 0L, 2L, 6L Regulator KG 3KG 3KG Cylinder 9KG 9KG 48KG Choosing the Size of Unit Use Require Temp 6lt 8lt 0lt 2lt 6lt 20lt Hand Basin 4-8lt/min 35-45 x x x x Kitchen 4-8lt/min 50-55 x x x x Shower 5-0lt/min 35-42 x x x Bath 2-20lt/min 48-55 x x x x Spa/ Jacuzzi 20lt/min 32-36 x x x x Page 4 of 2 Page 5 of 2

Dewhot gas geyser trouble shooting for customers Faults are either Electical - Flat Batteries, Physical - Flow pressure low or blocked, Mechanical - Damaged or faulty component Symptom Possible fault Solution Geyser is totally dead when the water is turned on. Batteries are inserted incorrectly 2. Batteries are totally flat Insert correctly, rear battery must be + down and front battery + up Replace with a brand new set of good quality batteries such as duracell Ignitors are firing, but the geyser is not igniting. Batteries are too weak to lift and hold the solenoid 2. Gas supply is low or not turned on Replace with a brand new set of good quality batteries such as duracell Turn on the gas or replace the bottle Ignitors are firing, geyser is coming on and going out after a very short time. Water inlet may be blocked at the water junction 2. The gas regulator may be blocked, particularly if a new bottle has just been fitted without first cracking the seal and letting a little gas bleed off Remove the water inlet pipe and check the sieve is not blocked on the geyser Change the regulator Water is flowing through the geyser, the LCD is illuminating but the geyser does not ignite. The micro switch is not activating enough to switch the geyser on 2. On-Off switch may be faulty Turn the RH knob to the right (clockwise) to increase the pressure and activate the geyser. This maybe experienced where you have low water pressure Call your installer Geyser comes on and after a short time the water comes through cold. The geyser temperature is set too high and the addition of any cold water will shut it off, either due to back pressure or the temperature has risen too high and the geyser shuts itself off The temperature with the hot water on only must be lowered, by turning down the flame. Do this by turning the LH Knob to the left (anti-clockwise) until the temperature is in the correct range. (refer to the chart on our website for the correct temperature setting; http://www.dewhot.co.za/compare_geysers.pdf The geyser is igniting loudly. The gas may be low or the gas regulator may be faulty Check gas level in bottle if low change If still no change, change the regulator The geyser is noisy when running. The water is causing resonance as it flows through the radiator Change the flowrate setting, RH knob either slightly to the left or right unit it disappears My geyser is very hot in the basin and cool for the bath. The setting and the use of the geyser needs to be understood Please watch the video how to control the temperature from the website; http://www.dewhot.co.za/dewhot-videos/ Page 6 of 2 Page 7 of 2

Installation of Gas Mimimun distances from doors, windows, drains and electrics Cascading To run a household with its multiple requirements a solution is to cascade. Use an 8lt to run a kitchen, a 0lt for the shower and run both to the bath giving 8lt/min. Fit non return valves so that the kitchen and shower can only run off their units May be reduced to 300 mm provided that a non combustible roof is installed between the containers and the window Outdoor light Electrical source of ignition, switchbox, distibution board, motor etc 8lt 0lt 3.5 LPG containers 2 5 Forced draught inlet for airconditioner Non Return Valve Non Return Valve 8lt 8lt 0lt Airbrick Page 8 of 2 Page 9 of 2

d Safety instructions: If you smell gas: Turn off the gas cock. Do not operate any electrical switches. Do not telephone from inside the danger area. Open windows and ventilate room. From outside, call the gas company and your approved installer. Do not use or store easily combustible materials in the vicinity of the appliance. Installation and Operating Instructions Installation and servicing of the appliance may only be carried out by a registered gas installer. The appliance should be regularly maintained in order to ensure that it remains in perfect and safe working order. If there is a risk of freezing, the appliance must be switched off and drained. If the appliance has not been drained during a cold spell then when it is switched on again check that it produces hot water. If problems occur, contact your installer Function This water heater is fitted with automatic electronic ignition that provides for easy commissioning. All that is required is to switch on a hot water tap. The appliance will then ignite automatically as soon as a hot water tap is turned on. The igniters fire (tick, tick, tick sound) the gas solenoid opens (clack sound) and then a second later the burners ignite and the ingniters stop firing. When you switch the water off the gas solenoid closes (faint thud noise). The appliance is substantially more economical because there is no pilot flame and only remains lit while water flows, thus no further gas is used, in contrast with conventional appliances which have a pilot flame that remains alight permanently. Air in the gas pipe when the appliance is commissioned must be vented, this can cause ignition failure. In such cases, the hot water tap should be turned off and then on again so that the appliance repeats the ignition cycle. The procedure should be repeated as necessary until the gas pipe is purged of air and ignition is achieved.. Chimney 2. Flue sensor 3. Heat exchanger 4. Thermostat 5. Temperature Probe 6. Base plate 7. Impluse 8. Impulse bracket 9. Ignition pin 0. Ignition pin. Flame sensor pin 2. Burner 3. Valve left bracket 4. Valve right bracket 5. Water and Gas valve 6. Micro switch 7. Battery 8. Battert 9. Battery box bracket 20. Battery box 2. Switch off for cold 22. Battery indicator 23. LED display (Optional models) 24. Front cover 25. Adjustment knob 26. Adjustment knob a. Hot water outlet b. Gas inlet c. Cold water inlet d. Flue pipe joint 2 7 3 5 6 8 9 0 3 a 4 4 2 b c 5 25 26 24 22 2 23 22 23 2 9 20 7 8 6 Page 0 of 2 Page of 2

www.dewhot.co.za