PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

Similar documents
SBP270 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

INSTRUCTION MANUAL. MCR1 Memory Card Reader 5/93. Copyright (c) 1993 Campbell Scientific, Inc.

LLAC4 Four-Channel, Low-Level AC Conversion Module Revision: 3/12

CURS Ohm Current Shunt Terminal Input Module Revision: 5/07

APPLICATION NOTE. Measuring Current Output Transducers with Campbell Scientific Dataloggers. App. Note Code: 2MI-B Revision: 1


HIH-4000 Series Humidity Sensors

CURS Ohm Current Shunt Terminal Input Module Revision: 7/13

Model SRMD Setra Remote Monitoring Display

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

BroadBand PowerShield. User Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Absolute and Relative Gas Concentration: Understanding Oxygen in Air

Global Water Instrumentation, Inc.

SDX Submersible Depth Transmitter User Manual

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

PRODUCT PROFILE FEATURES

Temp. & humidity Transmitter Instructions

User's Guide. Integrating Sound Level Datalogger. Model Introduction

INSTRUCTION MANUAL MODEL PCD-88

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

MACTek Corporation. USB HART Interface. Users Manual

Amplified High Speed Fiber Photodetectors

Light Meter (Foot Candles)

SEMICONDUCTOR TECHNICAL DATA

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

PS/2 Extender USER MANUAL.

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Owner s Manual & Safety Instructions

Instructions A Amp AC/DC Current Probe

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

Load Cell Amplifier Module. Instruction Manual LCA

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

ASKING FOR ASSISTANCE

Signal Manager Installation and Operation Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

RGC-IR Remote Gas Calibrator for IR400

Advantium 2 Plus Alarm

VK-250 WARRANTY REGISTRATION FORM

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

Installation and Operation Guide for PD5100 Automatic Transfer Switch

USB Rover port USB m Cat 5 Extender. User Guide

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

This product has the equivalent gain performance with the 14 element Yagi antenna.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Water Leak Detection System

Humidity Sensor. Model HU-224/225

Park 250 Brushless Outrunner Instructions

New MINIMAG Magnetic Stripe Reader

WEATHER STATION FOR SOLAR FARM MONITORING

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

HM1500LF Relative Humidity Module

AAV003-10E Current Sensor

i410/i1010 AC/DC Current Clamp

Sip/Puff Switch User Guide

EzFlex Combustible Gas Leak Detector Model EZ40

Subminiature Load Cell Model 8417

1000 Series Data Loggers PRODUCT MANUAL

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Ground Resistance Clamp-On Tester

TS-300-MSF TS-300 INSTALLATION AND CONFIGURATION MANUAL

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

PIEZOMETER AIRFLOW MEASURING RING

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

ExStik TM ph Waterproof Meters

Dual Laser InfraRed (IR) Thermometer

Original instructions Tina 3A/Aps Adaptor unit

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

Series 510 Submersible Level Transmitters

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Global Water Instrumentation, Inc.

EMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Tina 2A/B Adaptor unit

4 Port Hub User Manual

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Rackmount Intelligent Pressure Scanners

About this Manual. Support for Your Product

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

How to measure absolute pressure using piezoresistive sensing elements

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL. Kramer Electronics, Ltd. Models:

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Residential Standby Extended Warranty Statements


Transcription:

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL REVISION: 4/95 COPYRIGHT 1991, 1995 CAMPBELL SCIENTIFIC, INC.

WARRANTY AND ASSISTANCE The PTA-427 Barometric Pressure Transducer is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah 84321-1784 CAMPBELL SCIENTIFIC, INC. does not accept collect calls. Non-warranty products returned for repair should be accompanied by a purchase order to cover the repair. 815 W. 1800 N. Logan, UT 84321-1784 USA Phone (435) 753-2342 FAX (435) 750-9540 www.campbellsci.com Campbell Scientific Canada Corp. 11564-149th Street Edmonton, Alberta T5M 1W7 CANADA Phone (780) 454-2505 FAX (780) 454-2655 Campbell Scientific Ltd. Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX, U.K. Phone +44 (0) 1509 601141 FAX +44 (0) 1509 601091

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER 1. GENERAL The PTA-427 Barometric Pressure Sensor is designed to be installed in the same enclosure that the datalogger is housed. The enclosure must be vented to the atmosphere and kept stocked with active desiccant. A two foot power switching cable is provided to connect the sensor to the datalogger. If the PTA-427 is going to be housed outside of the datalogger enclosure, a longer cable must be ordered. The PTA-427 sensor outputs a 0-5 VDC signal for use with the 21X and CR7. For use with the CR10, a 2 to 1 voltage divider is incorporated into the power switching cable. The voltage divider converts the output from the sensor to 0-2.5 volts. The PTA-427 uses Vaisala's patented silicon capacitive pressure sensor. A linear output of 0-5 VDC is proportional to 800-1060 millibars (other ranges optional). The transmitter is temperature compensated over an operating range of -40 C to +60 C. The PTA-427 requires 11-30 VDC and a three second warmup time. 2. PTA-427 SPECIFICATIONS The following pressure transmitter specifications were provided by Vaisala, Inc.: TABLE 1. PTA-427 Specifications OPERATING RANGE Pressure Range (1 mb = 1 hpa) PTA-427 800 to 1060 mb PTA-427A 600 to 1060 mb Temperature Range -40 C to +60 C Humidity Range non-condensing ACCURACY PTA-427 Linearity * ±0.3 mb Hysteresis * Repeatability * Calibration uncertainty ** ±0.2 mb Accuracy @ 20 C *** ±0.4 mb PTA-427A Linearity * Hysteresis * Repeatability * Calibration uncertainty** Accuracy @ 20 C *** ±0.6 mb ±0.2 mb ±0.6 mb * Defined as ±2 standard deviation limits of end-point non-linearity, pressure hysteresis error and pressure repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the primary and working standards in reference to international standards. *** Defined as the root sum of the squares of end-point non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature. Temperature dependence at 1000 mb ±0.02 mb/ C at 800 mb ±0.08 mb/ C at 600 mb ±0.12 mb/ C Stability systematic offset drift ±0.2 mb/year effect of thermal and mechanical shocks less than ±0.3 mb GENERAL Supply voltage Supply voltage sensitivity Current consumption Output voltage Load resistance Settling time full accuracy after power on Warm-up shift Acceleration sensitivity Housing material Pressure fitting 1/8" I.D. tubing Overpressure limit Electrical connector Weight Dimensions: 11 to 30 VDC less than 0.1 mb 7 ma typical 0 to 5 VDC 10 kohm minimum 2 seconds to reach less than 0.1 mb less than ±0.05 mb/g aluminum barbed fitting for 2000 mb screw terminals 160 g 128 mm x 69 mm x 31 mm (5.0 in. x 2.7 in. x 1.2 in.) 1

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER 3. WIRING WHITE is not used on the 21X or the CR7 installation; it should be taped or cut to protect from shorting. FIGURE 3-1. Wiring for the PTA-427 4. DATALOGGER PROGRAMMING Instruction 4 is used to measure the PTA-427 barometric pressure transmitter. Instruction 4 excites the switching circuit which provides 12 VDC power to the sensor. The instruction delays three seconds after power-up and then makes a single-ended measurement of the output signal. Sample program for a 21X or CR7: 01: P4 Excite-Del-SE 01: 1 Rep 02: 5 5000 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 5000 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.052 Mult (Range in mbar / Output) 09: 800 Offset (Low Range of PTA-427) * Proper entries will vary depending on the program and datalogger channel usage. Sample program for the CR10: 01: P4 Excit-Del-SE 01: 1 Rep 02: 5 2500 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 2500 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.104 Mult (Range in mbar / Output) 09: 800 Offset (Low Range of PTA-427) * Proper entries will vary depending on program and datalogger channel usage. 5. MULTIPLIER AND OFFSET CALCU- LATIONS Output from the PTA-427 is 0-5 VDC, which corresponds to 800-1060 millibars (other ranges optional). The multiplier and offset used to convert the voltage measurements to millibars of pressure are: 2

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER Multiplier = Pressure range/output voltage range = 1060 mbar - 800 mb 5000 mv - 0 mv = 260 mb / 5000 mvolts = 0.052 The offset of the PTA-427 sensor is equal to the lower limit of the sensor range (i.e., the sensor range is 800 to 1060 mb, the offset is 800 mb). The measurement result using a multiplier of 0.052 and an offset of 800 is true barometric pressure in millibars. The weather service and most airports, radio stations and TV stations correct the pressure recorded at a particular station to what it would be if the station was located at sea level. This is done so that weather forecasters can obtain a clearer picture of what is happening as a storm crosses over mountains or high plateaus. The following equation is used to determine the pressure correction factor, which is added to the 800 mbar offset in Instruction 4 to have the datalogger output barometric pressure corrected to sea level. Because barometric pressure is strongly affected by elevation, the elevation of the site should be as accurate as possible. CR10 example with pressure correction factor: 01: P4 Excit-Del-SE 01: 1 Rep 02: 5 2500 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 2500 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.104 Mult (Range in mbar / Output) 09: 952.68 Offset CONVERSION FACTORS mbar * 0.0145 = PSI mbar * 0.75006 = mm of Hg mbar * 0.02953 = in. of Hg mbar * 0.00102 = kg/cm 2 mbar * 0.1 = kpa REFERENCES Wallace, J.M., and Hobbes, P.V., Atmospheric Science an Introductory Survey, Academic Press, New York, N.Y., 1977, pp. 59-61. P=1013.25[1-(1-E/44307.69231) 5.25328 ] where E is the elevation in meters above sea level. For example, the correction factor (P) for Logan, Utah, at 4450 Ft elevation is: 4450 ft * m/3.281 ft = 1356.29m Pressure correction factor (P) = 152.68 mbar Transducer offset = 800.00 mbar Pressure correction factor (P) = 152.68 mbar Offset for sea level correction = 952.68 3