Installation Guide. DEVIreg 316. Electronic Thermostat.

Similar documents
DEVIreg 330 (+5 to +45 C)

Installation Guide. DEVIreg 530. Electronic Thermostat.

Installation Instructions

GB/DAS User Instruction

HERZ-Thermal Actuators

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Danfoss Link Mobile Phone Butler

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

ACS-30-EU-EMDR-10-MOD

Data sheet ECC 12 and 22

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Drayton Digistat +2RF/+3RF

RRV934. Multi-controller. Synco living

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

The original heating cable just got better

Article: Version:

Product and functional description

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Wiring Diagram. Diplomat 400V 3N.

Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual

BG or BGE Brake Rectifier

User Manual THR840DUK Digital Thermostat

Installation & operating instructions

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Manual. Solar Fountain Mobile Phone Charger

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Meaco 30L and Meaco 40L dehumidifier instruction manual

Infrarot-Bewegungsmelder IP44

Digital input modules

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

TIG INVERTER INSTRUCTION MANUAL

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Heating Controller. Building Technologies HVAC Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

WD-AMX Water Detection Controllers

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Automatic Bypass Control AVDO

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

IO-RM3 3-Stage Relay Module

Installation and maintenance instructions. Danfoss Vent

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

AXIS T81B22 DC 30W Midspan

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Split Controller. User Manual SM-SS-F 2009/01/04

Product and Application Description

Portable Air Conditioner

Cable Plug acc. to DIN EN , Form A

RY2 miniature industrial relays

Controls for fan coil units and cassettes

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Contents. Document information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

US Installation Manual Smappee Monitor

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MOUNTING AND OPERATING INSTRUCTIONS

Three-phase monitoring relay CM-PFE

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

DALI RC BASIC SO. Control unit Operating instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

ELECTRIC INSTANTANEOUS WATER HEATER

Thermistor motor protection

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

PHOENIX CONTACT Features

Operating Instructions

MINI MCR-SL-R-UI(-SP)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Mounting instructions. Force transducer. A en

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Duct Humidity Transmitter

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Please also see 10 golden rules for correct Saniflo installation on

Transcription:

Installation Guide DEVIreg 316 Electronic Thermostat www.devi.com

The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC)

DEVIreg 316 Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 5 2 Mounting Instructions......... 6 3 Settings................. 8 3.1 Hysteresis............. 8 3.2 Minimum Temperature Limiter 9 3.3 Temperature Set-back...... 10 4 Warranty................. 10 5 Disposal Instruction.......... 10 1 Introduction DEVIreg 316 is an electronic thermostat to be installed in electric cabinets with DIN rail attachment. The thermostat must be installed via an all-pole disconnection switch. DEVIreg 316 applies to the control of room temperature, floor temperature, ventilation, cooling or to the control of snow melting in gutters and similar installations. For measuring purposes either a wire sensor or an external air sensor is used. Installation Guide 3

The thermostat has a button to adjust the temperature setting with a scale from -10 C to +50 C. An LED indicator shows standby periods (green light) and heating periods (red light). More information on this product can also be found at: devireg.devi.com 1.1 Technical Specifications Operation voltage 220-240V~, 50Hz Standby power consumption Max 0.25W Relay: Resistive load Inductive load Max 16A / 3680W @ 230V cos φ= 0.3 max1a Sensing units NTC 15kOhm at 25 C Sensing values: 0 C 25 C 50 C 42kOhm 15kOhm 6kOhm Hysteresis 0 to 6 C Ambient temperature 10 C to +45 C Lowering in economy periods 0 to 8 C Temperature range -10 C to +50 C DEVIreg 316 4 Installation Guide

DEVIreg 316 Minimum temperature range -10 C to +5 C Cable specification max 1x4mm 2 or 2x2,5mm 2 Ball pressure temperature 75 C Pollution degree Type Storage temperature 2 (domestic use) 1B IP class 30-20 C to +65 C Protection class Class II - Dimensions Weight 86 x 36 x 58mm 180g The product complies with the EN/IEC Standard "Automatic electrical controls for household and similar use": EN/IEC 60730-1 (general) EN/IEC 60730-2-9 (thermostat) 1.2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation. IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 C. Installation Guide 5

Please also note the following: The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. The thermostat must be connected to a power supply via an all-pole disconnection switch. Always connect the thermostat to continuous power supply. Do not expose the thermostat to moisture, water, dust, and excessive heat. 2 Mounting Instructions DEVIreg 316 Please observe the following placement guidelines: Install the thermostat in an electric cabinet with DIN rail attachment or a separate DIN attachment according to local regulation on IP classes. Do not place the thermostat in a way that it will be exposed to direct sunlight. Follow the steps below to mount the thermostat: 1. Click the thermostat on to the DIN rail attachment. 6 Installation Guide

7 8 2 9 3 4 5 DEVIreg 316 2. Connect the thermostat according to the connection diagram. Min. Sensor 10 11 12 1 N 6 L 250V~ 16 (1) A Mains 220-240V~ Danfoss A/S Ulvehavevej 61 7100 Vejle Denmark IP20-10T50 D316 The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Note: When you use the wire sensor for floor heating, always install the sensor in a conduit. 3. Turn on the power supply. Protective separation The thermostat is designed so that the sensor circuit is galvanically separated from the high voltage part which means that the sensor part is regarded as a low voltage part. Installation Guide 7

DEVIreg 316 3 Settings A B C Night set-back Minimum temperature limiter Hysteresis 3.1 Hysteresis When the thermostat is used to apply with either heating systems or refrigerating systems, and the requested temperature is between -10 C to +50 C, then it is recommendable also to adjust the hysteresis C according to the requested regulating range. As an example if the temperature is set at 18 C and the hysteresis at 3 C the thermostat will switch on at 18 C and off at 21 C. For controlling of room temperature the Hysteresis is recommended to the set point of 1 C. 8 Installation Guide

DEVIreg 316 3.2 Minimum Temperature Limiter When the thermostat is used in connection with snow and ice melting systems, it is recommendable also to use and adjust the minimum temperature limiter (B) which ensures both an upper and lower temperature range in between which the thermostat allows the system to heat. The requested maximum temperature range has to be between -10 C to +50 C and the requested minimum temperature range has to be between -10 C to +5 C. An link between terminal 9+10 must be connected to activate the use of the minimum temperature feature when the thermostat controls snow and ice melting in gutters, valley gutters and down pipes, where the waste of unnecessary energy must be avoided. In particular by extremely cold weather where flowing water or moisture does not occur. When the temperature drops below the minimum temperature set value, the thermostat stops heating and the LED indicator turns yellow. When the temperature exceeds the maximum temperature setting, the thermostat stops heating and both the indicator for minimum and maximum temperature disappears. Installation Guide 9

DEVIreg 316 3.3 Temperature Set-back By connecting an external timer to terminals 4 and 6, the thermostat can be set to reduce the temperature by 0 C to 8 C (A). 4 Warranty 5 Disposal Instruction 10 Installation Guide

DEVIreg 316 Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.devi.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logotype are trademarks of Danfoss A/S. All rights reserved. 08095512 & VICKF402 Produced by Danfoss 06/2012

DEVIreg 316-10<>+50 140F1075 220-240V~ 50-60Hz~ -10 to +50 C ECO Set back 0-8 C 16A/3680W@230V~ Product Documentation DK EL 7224215331 SE EL 8581194 NO EL 5491480 FI SSTL 3531017 Designed in Denmark for Danfoss A/S 5 703466 209240