SABROE packaged ammonia heat pump

Similar documents
Food industry Prosecc industry Heat & power (Production of district heating & cooling) Food industry Process industry Logistic centres Sport arenas

LG Electronics AE Company, Commercial Air Conditioning

ARP Food Industry, Portugal

ECOCIAT. Domestic hot water heat recovery unit

Chapter 3.4: HVAC & Refrigeration System

Geothermal Ice Arenas

Nirvana. Cycling Refrigerated Dryers

Thermal Coupling Of Cooling and Heating Systems

2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES

TRAINING, EXAMINATION AND CERTIFICATION

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY

RS-44 (R424A) : Q & A

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Part A: Fluid properties

Hot Water. Heat pump water heaters. Residential and Commercial R410a

REFRIGERANT REFERENCE GUIDE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Rusty Walker, Corporate Trainer Hill PHOENIX

District heating and district cooling with large centrifugal chiller - heat pumps

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

High Pressure Ammonia Systems New Opportunities

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Crowne Plaza Copenhagen Towers The world s greenest hotel

Air-cooled Chillers with High Speed Centrifugal Compressors

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

Split units TH with hermetic compressors

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

How To Clean Water From An Ammonia Refrigeration System

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Air conditioners Heating & Cooling

THE REPLACEMENT OF R-22

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

The GEA Group. May GEA Group Aktiengesellschaft

News in Data Center Cooling

Energy consumption and heat recovery of refrigeration system in modern Arena

8. Heat pumps, heat pipes, cold thermal energy storage

Mechanical Engineering Technician- Plant Technician

Air-conditioning with natural refrigerants

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Cooling kw Heating kw

The phase out of R22. Phase out of HCFCs

Energy Efficiency Best Practice Guide Industrial Refrigeration

HVAC Made Easy - Selection Tips for Chiller Compressors

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Top Technology for Industry, Agriculture, Business and Communities

Planning for the ban on R22 in building air conditioning

ThermoSorb Desiccant Dryers

How To Power A Power Plant With Waste Heat

imagine SOLAR AIR CONDITIONING MADE EASY

Refrigeration & Air-conditioning Technician

Inverter and programmable controls in heat pump applications

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

In touch with heat pumps for industry and commerce

How To Calculate The Performance Of A Refrigerator And Heat Pump

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

EU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Commercial CO 2 Refrigeration Systems

UNIT 2 REFRIGERATION CYCLE

Creating Efficient HVAC Systems

Direct Fresh Air Free Cooling of Data Centres

Mohan Chandrasekharan #1

DESIGN AND APPLICATION OF AMMONIA HEAT PUMP SYSTEMS FOR HEATING AND COOLING OF NON-RESIDENTIAL BUILDINGS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

HVAC Basic Science - System Capacity

HVAC Systems: Overview

HEATING, VENTILATION & AIR CONDITIONING

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Refrigeration Air Dryers. Catalogue

Guide to good leak testing

Making a world of difference. Turbocor centrifugal compressors for air-conditioning systems

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

1 Overview of applications and system configurations

Technical data. Danfoss DHP-A

Refrigerated Air Dryers. Catalogue

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

AdSORPTION CHILLER NAK

ASTACEA4 Inspect complex/central air conditioning systems

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Building Energy Systems. - HVAC: Heating, Distribution -

Transcription:

SABROE packaged ammonia heat pump

Ammonia - the natural choice Ammonia has a number of characteristics which make it the ideal refrigerant for future refrigeration purposes: Ammonia is the only refrigerant with no negative impact on the environment No ozone depleting potential (ODP) No global warming potential (GWP) A well-known and acknowledged refrigerant which has been used safely in refrigeration for more than 100 years Ammonia has the best thermodynamic efficiency A natural refrigerant which easily breaks down into nitrogen If refrigerant leaks should occur they will be easy to detect, as the distinct smell of ammonia serves as a natural built-in alarm It is inexpensive and significantly cheaper than other refrigerants

Why choose ammonia? What are the advantages? Known technology and plant design Better energy efficiency (COP) Better heat transfer coefficient Available and low-priced all over the world Non-mixable with oil Less sensitive to humidity in the plant Smaller compressor - same capacity Smaller heat exchangers - same capacity Smaller circulated quantity

SABROE Ammonia heat pump compressor The natural choice

The natural choice Sabroe ammonia 40 bar heat pump compressors Types HPO and HPC Features: Ammonia is an ozone-friendly refrigerant Heat pump systems reduce the CO 2 emission The series covers the entire water temperature range up to 70 C. Compared with CFC, HCFC and HFC systems you will gain the following advantages: - higher efficiency (COP) - reduced compressor size - smaller evaporators - smaller condensers - smaller pipe and valve dimensions Capacity range: 100-1500 kw (one compressor) Multiple applications HPC104-106-108S HPO 24-26-28

Sabroe packaged ammonia heat pumps: Advantages Compact design Small ammonia charge Evaporator and condenser in suitable materials Efficient closed oil and oil recovery system High COP and energy optimal solution even at part load First charge of PAO5(P100) full synthetic oil Unisab II - a complete control and monitoring system with external communication facilities Flooded system with ammonia gives an optimum thermal solution and secures an optimum operating economy Tested with ammonia before dispatch

EOL - End Of Line Test centre All units are tested with ammonia A capacity test is available as an option Specified performance is confirmed Trouble-free on-site start-up and operation Shorter and safer start-up and commissioning periods

Sabroe packaged ammonia heat pump: Application areas Dairies Ice rinks Airports Slaughterhouses Breweries Poultry industries District heating Process Industries

Applications Sabroe ammonia heat pump compressors are perfectly suited for a large number of applications, such as: Heat reclaim for hot/warm water production in ammonia refrigeration plants within the food industry (abattoirs, dairies, ice cream factories, fish processing, freeze drying, breweries, slaughter houses etc.) Condenser heat reclaim from refrigeration systems Upgrading of industrial waste heat for use in industrial processes, district heating, individual buildings, etc. Heat pump systems based on natural heat sources such as sea water, air and geothermal energy Special applications such as wood seasoning, fish drying, exhaust gas cooling in power plants, etc. Heating in ice rinks or other sports arenas. Hot water for baths and swimming pools.

One-stage heat pump unit: Example: Brewery/district heating Performance: Heating capacity 2131 kw Evaporating temperature +30ºC Sink temperature in/out 60/70ºC Condensing temperature 73.5 ºC Flow 187 m 3 /h COP 5.6 Shaft power 381 kw

Two-stage heat pump unit: Combined chiller - heat pump unit 65ºC 55ºC Performance: Cooling capacity 210 kw Sink temp. in/out 55/65ºC Water temp. in/out 15/8ºC Flow 25.5 m 3 /h Chilled water flow 26.1 m 3 /h Shaft power LP compressor 29 kw Heating capacity 290 kw Shaft power HP compressor 53 kw

Sabroe packaged ammonia heat pump: Cascade or water / one- or two-stage One-stage HPO26 Twin Two stage HPC108/SMC116 Twin One-stage HPO28 Twin

Sabroe packaged two-stage ammonia heat pump unit Two stage HPC108/SMC116 Twin Technical information Product-type : Heat pump Compressor type : Reciprocating compressors Electrical options: Heat exchangers : Plate heat exchangers / Terminal box shell & tube Control panel Refrigerant : R717, flooded Starter panel Capacity-range : 200 4000 kw (Low/high voltage, 50/60 Hz) Temperature range : 72 o C water temperature Variable speed control on condenser Softstarter Secondary media : Water Approval : PED, others on request Design-pressure : 40 Bar A

Sabroe packaged two-stage ammonia heat pump unit Technical information Two stage HPC108/SMC116 Twin Duty (Condenser) Media : 4000 kw / 72 O C : Water Number of compressors : 4 Power Voltage : 2x 250 kw / 2x 400 kw : 400 V

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

Sabroe packaged ammonia heat pump: Application areas

NSPAC HPC108S Traditional design of heat pump unit

Safe use of ammonia plants SABROE & YORK will support the use of natural refrigerants - invest and develop products for the purpose only! SABROE & YORK will support the use of R717 for many years to come - and is therefore reluctant to see this unique refrigerant fall into discredit due to lack of knowledge.