BTL5-A/C/E/G -M/U -P-S32/KA Technical Description User's Guide



Similar documents
BTL5-P1 _-M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

BTL5-S1 -M -HB/WB-FA /F -C Micropulse Linear Transducer - Rod Style

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive sensor NI10-M18-Y1X-H1141

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Adjustment functions for both span and shift have been incorporated

Series 7500 Torque Sensor

Series 6000 Torque measured metal bellow coupling

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

PROFIBUS-DP BTL5-T1 -M/U -B/Z-S103. Technical Description User's Guide. english

DS 600. A contact free flux gate based current measurement sensor 600A rms

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Subminiature Load Cell Model 8417

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Air damper actuators

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Analog signal converters CC-E I/I Current / current isolators

Digital input modules

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Modular I/O System Analog and Digital Interface Modules

Cable Plug acc. to DIN EN , Form A

Power Supplies 3. SDN-P DIN Rail Series

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

D. PARAMETER SPECIFICATION Measured Variable: Displacement

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Three-phase monitoring relay CM-PFE

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

How To Use A Flowmeter

Duct Humidity Transmitter

Redundancy Module QUINT-DIODE/40

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

48 SERIES Relay interface modules 10 A

TECHNICAL DATASHEET Incremental Encoder RI 58-H

38 Series - Relay interface modules A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MasterINTERFACE 39 Series - Relay interface modules

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

HERZ-Thermal Actuators

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

49 Series - Relay interface modules A. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

38 Series - Relay interface modules A

BOS 73K... BOS 74K...

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Proximity Switches RS (Reed Switch)

1701/22 FieldMonitor Management Interface Module

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

STRATO LED Drivers 70W, Single output

Mounting instructions. Force transducer. A en

Telephone- and leased line modem for industrial applications TD-36

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Technical Data. Dimensions

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Instruction Manual Differential Pressure Transmitter

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Digital display DA 48

Encoder WDGI 58H.

Cross-beam scanning system to detect slim objects. 100 mm in

SEISMIC VELOCITY TRANSDUCER T1-40

Conductive Level Switch FK 2 Technical Data:

Displacement encoders

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Energy Management Energy Meter Type EM23 DIN

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RM4TG20 three-phase network control relay RM4-T - range V

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

QR12 (1.22 ) Diameter Optical Encoder

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Transcription:

Technical Description User's Guide Gebhard Balluff GmbH & Co. Gartenstrasse 21 25 D-73765 Neuhausen/Germany Phone (+49 71 58) 1 73-0 Fax (+49 71 58) 50 10

Safety Advisory These transducers together with processor card and/or programmable controller comprise a positioning system and may be used for this purpose only. Installation and Operation Installation and operation should be performed only by trained technical personnel. Unauthorized intervention and usage will result in loss of warranty and liability claim rights. When assembling the transducer, all specifications included in the section on Installation and Wiring must be observed. Special care with respect to selection and polarity of the connections should be taken when connecting the transducer to external controllers, including the power supply and form and duration of the control signals. Refer to the section on Technical Data for details. Only approved, regulated power supplies may be used for the positioning system. Usage and Checking All relevant safety regulations must be complied with when using the transducer system. In particular, precautions must be taken to ensure that any defect in the positioning system will not result in risk to persons or property. This may include the use of additional safety limit switches, E-STOP switches, and maintaining the permissible ambient conditions. The functionality of the positioning system and all associated components must be checked and documented regularly. Function Disturbances Whenever there are indications that the positioning system is not working properly, it should be taken out of service and guarded against unauthorized use. Scope This description is valid for the Micropulse TM linear displacement transducer series BTL5-A/C/E/G...P.... Features and Advantages Micropulse transducers feature: Very high resolution, repeatability and linearity. Function and Design The transducer contains a tubular waveguide, protected by an aluminum extruded housing. A position magnet attached to the moving member of a machine or component to be positioned travels along the housing (Fig. 1). Notch on housing to mark the beginning of the stroke range Nominal length = stroke El. connection Fig. 1: The positioning magnet defines the position to be measured on the waveguide. An externally generated INIT pulse in conjunction with the magnetic field produces a torsional wave in the waveguide (magnetostriction), which propagates at ultrasonic velocity. The wave component reaching the far end of the waveguide is absorbed by a damping technique. The component reaching the connection end passes through a coil, generating an Versions (indicated on product label) Immunity to shock, vibration, contamination and electrical noise. An absolute output signal. IP 67 per IEC 529. electrical signal. The wave propagation time is used to derive the position. Depending on the version the corresponding value is output as a voltage or a current either with rising or falling characteristic. This process takes place with extremely high precision and repeatability within the stroke range defined as nominal length. On either side of the stroke range is a zone within which no reliable signal is available, but which may be entered by the magnet. The electrical connection between the transducer and the processor or controller is made with a cable, which is either fixed to the transducer or detachable via a connector. For optimal adaptability, a wide variety of nominal stroke lengths and magnet form factors are available. Magnets and control arms must therefore be ordered separately. Dimensions for the Micropulse transducer are shown in Figs. 2 and 3. For magnet and control arm dimensions, see Figs. 6ff. Nominal Lengths The following nominal lengths are available in the increments given: from 50 to 1000 mm every 50 mm, from 1000 to 2000 mm every 100 mm, from 2000 to 3750 mm every 250 mm, other lengths upon request. Supply voltage 1 = 24 V DC, 2 = ±15 V DC Electr. connection (S32: with connector), BTL5-A11-M0450-P-S32 (KA05: with 5 m cable) Profile form factor Nom. length (4 digits), M = metric in mm U = inches in 1/10 inch Micropulse TM Linear Transducer Current position of magnet Micropulse Transducer Machine Basic arrangement Moving machine part Damping zone Analog interface: Voltage output A_1 = 10... 0 V and 0... 10 V G_1 = 10... 10 V and 10... 10 V Current output C_0 = 0... 20 ma E_0 = 4... 20 ma C_7 = 20... 0 ma E_7 = 20... 4 ma 2

Transducer, Installation NL Nominal length Fig. 2: Dimensional drawing for BTL5...P-S32 (with magnet BTL5-P-3800-2) Ensure that no strong electrical or magnetic fields are introduced in the immediately vicinity of the transducer. The installation orientation is not critical. Attach the transducer to a level surface on the machine using the supplied mounting clamps and cylinder head screws. Sufficient quantity of mounting clamps will be supplied. These should be spaced evenly (Fig. 2). Recommended spacing for long transducers and/or strong shock and vibration: A = ca. 80 mm; spacing between the individual clamps B = ca. 250 mm each. The supplied isolation bushings serve to electrically isolate the transducer from the machine (see Fig. 3 and section "Start up/noise Elimination"). NL Nominal length Round, black marking Magnet Mounting clamps with isolation bushings and cylinder head screws M5 x 22, DIN 912, max. torque 2 Nm Fig. 3: Dimensional drawing with profile dimensions (tansducer BTL5...P-KA.. with magnet BTL5-F-2814-1S) Wiring To avoid coupled noise, avoid proximity to high-current lines when routing cable between transducer, controller and power supply. Inductive coupled noise from AC harmonics (e.g., from phase controls) are especially critical, against which the cable shield offers no protection. Cable length max. 500 m; Ø 6 to 8 mm. Longer lengths may be used if construction, shielding and routing are such that external noise fields will have no effect on signal integrity. transducer BTL5-E10... 4...20 ma 0 V 10...0 V 0...10 V GND +24 V GND YE GY PK GN BU BN WH processor/ controller with analog input Fig. 4: BTL5-E10...KA with processor card/controller, wiring example 3

Wiring (cont.) Output signals Pin Cable BTL5-A_1 -C_0 -C_7 -E_0 -E_7 -G_1 1 YE yellow not used 0...20 ma 20...0 ma 4...20 ma 20...4 ma not used 2 GY grey 0 V ➀ 3 PK pink ➁ 10...0 V 10...0 V 10...0 V 10...0 V 10...0 V 10... 10 V 4 not used 5 GN green ➁ 0...10 V 0...10 V 0...10 V 0...10 V 0...10 V 10...10 V Supply voltage (external) Pin Cable BTL5-A/C/E/G1_ BTL5-A/C/E/G2_ 6 BU blue GND ➀ ➂ GND ➀ ➂ 7 BN brown +24 V DC +15 V DC 8 WH white GND 15 V DC Important wiring note: To ensure electromagnetic compatibility (EMC), which Balluff verifies by the CE Marking, the following points must be strictly observed. BTL transducer and processor / controller must be connected using shielded cable. Shield: Copper-stranded mesh, 80 % coverage. The shield must be connected in the BKS connector (Fig. 12) to the body of the connector; see instructions packaged with the connector. The shield must be grounded on the control side, i.e., connected to the protection ground. Unused leads can be tied to GND on the control side, but they must never be connected to the shield. Refer to the table for wiring assignments. Connections on the controller side may vary according to the controller and configuration used. BKS connector, view towards solder side of female BKS-S 32M-00 or BKS-S 33M-00 Fig. 5: Start-up Pin assignments BKS, connector type BTL Check your connections Even though the connections are protected against polarity reversal, components may be damaged by incorrect wiring and overvoltage. Before you power up, check your connections carefully. Turning on the system Please note that when the system is turned on, uncontrolled movement can result, especially at first powerup and when the transducer is part of a closed-loop feedback system whose parameters are not yet set. Therefore ensure that start-up cannot lead to hazardous conditions. If there is no magnet in the stroke range, the integrated function monitor provides the following defined output signals: Voltage output 10 V increasing decreasing U A > 10 V < 0 V Note: 1 The analog transducer outputs are potential-free. When connecting to a module with non-potential-free inputs, ground loops may cause erroneous signals. Avoid this by defeating the potentialfree function in the transducer: jumper Pin 2 and Pin 6 in the female connector (Fig. 5). ➁ A small voltage difference (< 10 mv) appears between pin 3 and 5 due to seperate output drivers. ➂ Reference GND for supply voltage and EMC! Current output 20 ma increasing decreasing I A > 20 ma 0 ma for BTL5-C... I A > 20 ma < 4 ma for BTL5-E... Check signal values After installing a repaired or new transducer, we recommend you manually check the values given for the start and end position of the magnet. If you read different values* than before the change or repair, be sure to compensate accordingly. * Slight variations due to manufacturing tolerances or product improvement are possible. Eliminating noise To avoid potential compensation - current flow - through the cable shield, we recommend use of the isolation bushings. Potential compensation occurs when the ground potential between control cabinet and machine is not the same. 4

Magnets, Installation Floating magnets Fig. 6: Magnet BTL5-P-3800-2 The Micropulse transducer in profile housing can be used with either a floating (non-contact) magnet (see Figs. 2 and 6 to 8) or the captive (guided) magnet design (see Figs. 3, 9 and 11). Floating magnet The floating magnet (Figs. 6 to 8) is attached to the moving machine member using non-magnetizable screws (brass, aluminum). To assure accuracy of the transducer system, the moving member of the machine must carry the magnet along a parallel axis to the transducer. The following table show specifications in [mm] for distance between magnet and transducer as well as the permissible offset from center: Magnet type Distance " D " Offset " C " BTL5-P-3800-2 0.1... 4 ± 2 BTL5-P-5500-2 5... 15 ± 15 BTL5-P-4500-1 0.1... 2 ± 2 Captive magnets When using the guided magnets (Figs. 9 and 11), lateral forces should be avoided. This calls for connections which allow a corresponding freedom of motion along the magnet axis of travel. The warranty assumes that the BTL5-F-2814-1S magnet is connected with the machine member using a control arm. The BTL2-GS10...A control arm (Fig. 10) is available as an accessory (specify length LG when ordering). Captive magnets Ball joint "B", DIN 71805, turns 360 Round, black marking Fig. 7: Magnet BTL5-P-5500-2 Fig. 9: Magnet BTL5-F-2814-1S Connector with LED Lock nut M5 DIN 934 Swivel eye DIN 648 Ball joint "B" DIN 71805 (part of magnet type BTL5-F-2814-1S) Fig. 10: Control arm BTL2-GS10...A Threaded bolt M5 firmly fastened mechanically Fig. 8: BTL5-P-4500-1 Electromagnet (24 V/100 ma) Advantages: Multiple magnets on a single transducer can be individually switched on and off (e.g., from a programmable controller digital output card). 2 nuts M5 BTL5-M-2814-1S X = 48,5 Y = 57 BTL5-N-2814-1S X = 51 Y = 59,5 Fig. 11: Magnet BTL5-M/N-2814-1S 5

Technical Data Typical values at 24 V DC and 25 C. Ready for operation at once, full accuracy after warm-up (approx. 15 min after switching on). With a constant gap to transducer when using magnets BTL5-P-3800-2, BTL5-P-4500-1 or BTL5-P-550-2 or with guided magnets BTL5-F/M/N-2814-1S (exceptions see magnets): Outputs BTL5-P-4500-1 (Fig. 8) Weight ca. 90 g BTL5-A... Output voltage 0...10/10...0 V BTL5-F-2814-1S (Fig. 9) Load current < 5 ma Weight ca. 28 g Ripple < 5 mv BTL5-G... BTL5-M-2814-1S (Fig. 11) Output voltage 10...10/10... 10 V Weight ca. 32 g Load current < 5 ma Housing anodized aluminum Ripple < 5 mv Contact surface plastic BTL5-C... BTL5-N-2814-1S (Fig. 11) Output current 0...20/20...0 ma Weight ca. 35 g Load resistance < 500 Ohm Housing anodized aluminum BTL5-E... Contact surface plastic Output current 4...20/20...4 ma Load resistance < 500 Ohm Control arm (optional) BTL2-GS10- -A Connection to processor Aluminum, see Fig. 10 for dimensions Various standard lengths LG (specify when ordering) Resolution < ±2 µm + Hysteresis < ±4 µm = Repeatability < ±6 µm ^= Voltage < ±0.1 mv ^= Current < ±0.16 µa Sampling rate f Standard = 1 khz Non-linearity Nom. length < 500 mm > 500 mm in µm ±100 ±0.02 % FS in mv < 1000 nom. length/mm < ±2 mv Temperature coefficient Voltage output: [150 µv/ C + (5 ppm/ C * P * V/NL)] * DT Current output: [0,6 µa/ C + (10 ppm/ C * P * I/NL)] * DT V = output voltage range in [V] I = output current range in [ma] NL = nominal length in [mm] DT = temperature coefficient in [K] P = magnet position in [mm] Shock 100 g/6 ms per IEC 68-2-27 Vibration 12 g, 10 to 2000 Hz per IEC 68-2-6 Dimensions, weight, ambient Nominal length < 3750 mm Dimensions see Figs. 2 and 3 Weight ca. 1.4 kg/m depending on version and stroke Housing anodized aluminum Housing attachment Mounting clamps with isolation bushings and screws Operating temp. 40 to +85 C Humidity < 90 %, non-dewing Protection rating per IEC 529 IP 67 with connector attached Supply voltage (external) Regulated voltage BTL5-_1... 24 V DC ±20 % Ripple < 0.5 V pp BTL5-_2... ±15 V DC ±2 % Current draw < 150 ma (at 1 khz) Inrush < 1 A Time constant ca. 10 ms Polarity reverse protection built-in Overvoltage protection Transzorb protection diodes Isolation voltage GND to housing 500 V Analog interface: With S32 connector for shielded cable (max. length, see "Wiring"), diameter 6 to 8 mm, or with integral cable (5 m long) Magnets (please order separately) Re: distance, offset and installation dimensions, see pages 3 and 5 Operating temp. 40 to +85 C BTL5-P-3800-2 (Fig. 6) Weight ca. 12 g BTL5-P-5500-2 (Fig. 7) Weight ca. 40 g Non-linearity: Nom. length< 500 mm > 500 mm ±150 µm ±0,03 % FS The CE Marking verifies that our products comply with the requirements of EC Directive 89/336/EWG (EMC Directive) and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for Testing Electromagnetic Compatibility, has shown that Balluff products meet the EMC requirements of the Generic Standard EN 50081-2 (Emission) EN 50082-2 (Noise Immunity) Accessories (optional) Connectors Types, dimensions see Fig. 12 straignt right-angle BKS-S 32M-00 BKS-S 33M-00 No. 99-5672-19-08 No. 99-5672-78-08 (Binder part no.) Cable entry (PG 9 fitting) Fig. 12: Connector (optional) Emissions tests: Radio frequency emission EN 55011 Group 1, Class A Noise immunity tests: Static electricity (ESD) IEC 1000-4-2 Severity Level 3 Electromagnetic fields (RFI) IEC 1000-4-3 Severity Level 3 Fast transients (BURST) IEC 1000-4-4 Severity Level 4 Line transmitted noise disturbances, induced by high-frequency fields IEC 1000-4-6 Severity Level 3 No. 810 937 E Edition 9802; Specifications subject to change Replaces edition 9710. 6