Environmental Chambers for Battery Testing.

Similar documents
CSZ s EZ-View Software

Advanced Test Equipment Rentals ATEC (2832)

Analysis of Battery Safety and Hazards Risk Mitigation. Cyrus N. Ashtiani

Batteries in HP notebooks

Lithium Battery Testing Under UN/DOT 38.3

TRANSPORT OF DANGEROUS GOODS

PROGRAMME OF WORK FOR THE BIENNIUM Work on the inclusion of ultra capacitors in the UN Model Regulations

THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY

Safety Issues for Lithium-Ion Batteries

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Compressed Gas Cylinder Safety

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

12 Volt 30 Amp Digital Solar Charge Controller

Vibration Test for Large Lithium-ion Battery Assemblies on UN Transportation Manual of Tests & Criteria JARI

Energizer Non-Rechargeable Batteries: Frequently Asked Questions

Title Li-ion Battery Specifications (Steel) Page 1/11

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

The Future of Battery Technologies Part I

ENVIRONMENTAL TESTING

A Guide to the Safe Use of Secondary Lithium Ion Batteries in Notebook-type Personal Computers

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Battery Technology for Data Centers and Network Rooms: Ventilation of Lead-Acid Batteries

North Carolina State University Emergency Facilities Closure Checklist- Part I

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A.

USB-500/600 Series Low-Cost Data Loggers and Accessories

Safely Transporting Lithium Batteries by Air JANUARY 2015

INTERNATIONAL STANDARD

SAFETY PERFORMANCE OF A LARGE FORMAT, PHOSPHATE BASED LITHIUM-ION BATTERY

LITHIUM BATTERY CR123A SPECIFICATION

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

IEC nd Edition: All you need to know about the new standard

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Wireless Data Logger Monitoring Systems

3000W Power Inverter

AIR-CONDITIONER SPLIT TYPE

Choosing Close-Coupled IT Cooling Solutions

Smart Anytime, Safe Anywhere. Climax Home Portal Platform. Envisage and Enable a Connected Future

MAKING LITHIUM-ION SAFE THROUGH THERMAL MANAGEMENT

Automotive Lithium-ion Batteries

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Spec. No. ICR C Version No. 0.0

Beats Product Information Sheet 20 Watt Hours

USB-500/600 Series Low-Cost Data Loggers and Accessories

Overview of Lithium Battery. Safety

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

lithium iron phosphate

Practical Examples of Galvanic Cells

Application Note: Use of Low Resistivity Surface Mount PPTC in Li-ion Polymer Battery Packs

Addressing the Impact of Temperature Extremes on Large Format Li-Ion Batteries for Vehicle Applications

Understand Hybrid Generator Battery Systems

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

BATTERY SERVICE. This Automotive Series BATTERY SERVICE has been developed by. Kevin R. Sullivan. Professor of Automotive Technology Skyline College

User s Manual Before using the inverter, you need to read and save the safety instructions.

High Energy Rechargeable Li-S Cells for EV Application. Status, Challenges and Solutions

Material Safety Data Sheet

Specification Approval Sheet

DELIVERY SPECIFICATIONS

Tel.X Ni-Cd battery. The compact solution for stationary applications

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Battery Technology for Data Centers and Network Rooms: Lead-Acid Battery Options

Heating and air-conditioning industry

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

PRODUCT SAFETY DATA SHEET

Product Title Abstract

METHOD EXPLOSIVE ATMOSPHERE

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Stationary Storage Battery Systems

Apple Product Information Sheet 20 Watt Hours

Lithium Iron Phosphate High Current Rechargeable Lithium Ion Batteries

Freezers - Ultrafreezers. Platilab & Irilab Series

CNG & Hydrogen Tank Safety, R&D, and Testing

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

MATERIAL SAFETY DATA SHEET

How To Use An Irius Pid Detector

User Manual for CH-PFC76810

Application Requirement

moehwald Bosch Group

Hygro-Thermometer + InfraRed Thermometer Model RH101

User Guide. Temperature and Humidity Datalogger. Model 42280

Portable Air Conditioner

Hazardous Substance Class Definitions & Labels

Compressed Gas Cylinder Storage and Handling Guide

CARING FOR YOUR WATER HEATER

Safety data sheet for product

A&E Specifications RoadRunner HD High Definition Mobile Recording System

Emergency Response Guide

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Pressure Vessels (Air Compressors) and LPG Tanks

THE DETECTION OF GREENHOUSE GASES

PAINT BOOTH LIGHTING

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

All You Ever Wanted to Know About Fire Extinguishers...

Transcription:

Environmental Chambers for Battery Testing www.cszindustrial.com/battery www.cszindustrial.com/green

Battery Testing Solutions Cincinnati Sub-Zero (CSZ) is a leading provider of environmental test chambers with over 75 years of industry experience in designing and manufacturing temperature-humidity controlled products. CSZ supplies a variety of test chambers for testing batteries of any size. We offer extensive experience in chambers designed for testing NIMH, lead acid and lithium ion batteries from small battery cells to large battery packs. Battery testing chambers are supplied to a variety of industries including, automotive, computer, telecommunications, defense, and alternative energy markets. With the goal of reducing automobile emissions and the push toward electric hybrid vehicles, the need for lithium ion battery testing is even more critical. Our proven experience provides the most cost-effective solutions. Each test chamber is built according to specific test requirements and may be interfaced with battery cyclers, control & monitoring data acquisitions systems and other test equipment for a complete integrated test solution. CSZ reach-in and walk-in chambers featured at GM Battery Test Laboratory. 2 TF: 800-989-7373 I PH: 513-772-8810 I www.cszindustrial.com

Environmental chambers are available from small benchtop chambers for testing small battery cells to large walk-in chambers for testing large battery packs. Temperatures range from -70 C to +190 C (-94 F to + 375 F) with an optional humidity range as low as 10% to 95%. Sizes are available from small benchtop units to large walk-in rooms. Products High/Low Temperature Cycling Chambers Humidity Chambers Thermal Shock Chambers AGREE Temperature/Vibration Chambers Altitude Chambers Explosion Proof Chambers Temperature Ranges Single Stage: -34 C to +190 C (-30 F to +375 F) Tundra : -45 C to +190 C (-49 F to +375 F) Tundra II: -50 C to +190 C (-58 F to +375 F) Cascade: -70 C to +190 C (-94 F to +375 F) Exclusive Tundra Refrigeration System The utilities involved with battery testing facilities and electric consumption add to the operating cost of each piece of equipment, a consideration to the bottom line and an important aspect in selecting test equipment. The compressors on an environmental chamber are often a large portion of the electrical load. CSZ offers the patented Tundra system, which utilizes a single compressor to get to -45 C (-49 F), and the Tundra II system which also uses a single compressor and provides the ability to test as low as -50 C (-58 F). By using only one compressor for cold temperature testing at these low temperatures, significant savings can be realized in both operating and maintenance costs. AGREE Temperature, Humidity Chamber interfaced with Vibration Shaker Table 3

Features and Options Features and Options Safety Features and Options CSZ provides safety features for reliability and abuse testing of batteries. Each environmental chamber is designed with safety in mind. Safety features may be incorporated into CSZ test chambers and tailored to the various hazard levels (0-5) to help mitigate potential risks. Hazard Severity Level Description Classification Criteria and Effect 0 No Effect No effect. No loss of functionality 1 Passive Protection No defect; no leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. Cell reversibly damaged. Repair of protection device needed. Activated 2 Defect/Damage No leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. Cell irreversibly damaged. Repair needed. 3 Minor Leakage No venting, fire, or flame*; no rupture; no explosion. Weight loss <50% of electrolyte weight (electrolyte = solvent + salt). 4 Major Leakage/ Venting No fire or flame; no rupture; noo explosion. Weight loss 50% of electrolyte weight (electrolyte = solvent + salt). 5 Fire or Flame No rupture; no explosion (i.e., no flying parts). 6 Rupture No explosion, but flying parts of the active mass. 7 Explosion Explosion (i.e., disintegration of the cell). * The presence of flame requires the presence of an ignition source in combination with fuel and oxidizer in concentrations that will support combustion. A fire or flame will not be observed if any of these elements are absent. For this reason, we recommend that a spark source be use during tests that are likely to result in venting of cell(s). We believe that credible abuse environments would likely include a spark source. Thus, if a spark source were added to the test configuration and the gas or liquid expelled from the cell was flammable, the test article would likely progress from level 3 or level 4 to level 5. Reference: FreedomCAR: Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Vehicle Applications SAND 2005-2123 Failure modes Cracks in membrane separating anode and cathode Overheating Over charging Under charging Battery Testing Risks Chemical reactions Thermal charges & thermal runaways Reactions to overcharge Reactions to fast charge Reactions to damage Rupture Fire & flame from ignition of flammable gas/liquid Explosion 4 TF: 800-989-7373 I PH: 513-772-8810 I www.cszindustrial.com

Safety Features and Options Safety Door Interlock - Prevents entry either during tests or after an event Custom Pressure Relief Vent - Protects chamber from a sudden release of high pressure gas Fresh Air Exchange System - Aids in removing all gases from inside the chamber prior to opening the door Temperature Limited Sheath Heaters - Standard ni-chrome wire heaters can reach temperatures of +540 C (+1000 F). Temperature is set below ignition temp. of gases Intrinsically Safe Barriers - Prevents the potential of high voltage pulses Gas Monitors - O2, H2, CO, etc - Can be interlocked to controller to shut down chambers Air Exchange System Protective Enclosure/Structure - External structure that would contain any fire or explosion Non Sparking Fan Blades or Blower Wheels - Prevents sparking/explosion Fire Suppression-Inert Atmosphere Uses N2 or CO2 to eliminate Oxygen - does not prevent thermal runaway but can help contain Gas Monitor System C02 Fire Suppression System Reinforced Chamber Floor - To support weight of heavy product and extreme temperature LN2 Test Article Surface Cooling - Used to cool cells or packs if they overheat - may help prevent thermal runaway GN2 Purge - Helps flush out outgassing from product under test 5

EZT-570S Controller The Next Generation Controller with Smartphone Technology Save valuable time with the ease of use of the EZT-570S featuring fewer steps to accomplish your daily testing needs while incorporating simplified operation and programming to test faster. Communications & Connectivity Remotely monitor and/or Control the chamber for anytime, anywhere access from any device (PC, smarphone or tablet) using LAN/VNC. Alarm notification system sends email and/or text phone messages in the event of a test chamber alarm, saving valuable tests while reducing downtime. Multiple chambers may also be managed using VNC or CSZ s optional EZ-View PC software to monitor & control CSZ chambers and download profiles. Profiling Profiling includes up to 99 steps and 1000 cycles. Program ramp steps entering time or C/min. Easily review profile using trend chart or list of steps Profile status view displays current step, estimated start/stop date and time. Profiles may be transferred to different chambers via USB or optional EZ-View software. Automated delay profile start. Data Logging Configurable log interval, data file length, filename, operator entered batch & lot information as well as an unlimited number of operator notes saved to the data file. Easily download profiles, alarm files, audit trail files and data files using USB or email from controller in a compatible.csv file format. Files may automatically be backed up using FTP. Email built-in to send data, alarm, audit trail files directly from controller. Also create and send new emails. Open and plot historical data files. User Convenience & Flexibility Controller may be configured in any of one of 28 languages one setting updates icons, menus and help screen. Selectable power failure/recovery options. Full system security allows up to 30 different users with four different levels of security. Audit trail files track changes in settings by each user. Import/export configuration settings to other controllers saving time. (Personalized to your use) Configurable alarms and maintenance alerts. 6 TF: 800-989-7373 I PH: 513-772-8810 I www.cszindustrial.com

Battery Test Specifications for Environmental Testing Test Specification IEC 62660-2 SAE J2464 IEC 60086-4 UL 1642 UN Lithium Battery Testing IEC 61960 IEC 62133 UL 2054 IEEE 1625 IEEE 1725 Description Reliability & Abuse Testing for Lithium Ion Cells in Electric Vehicles EV & HEV Rechargeable Energy Storage System Safety & Abuse Testing Primary Batteries, Part 4: Safety of Lithium Batteries Standard for Lithium Batteries UN Lithium Battery Testing Requirements Secondary lithium cells and batteries for portable applications Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications Household and Commercial Batteries Laptop Rechargeable Batteries Phone Rechargeable Batteries Battery Cell Testing 7

The Experience you Rely on... Cincinnati Sub-Zero (CSZ) Products, Inc. is an ISO-9001 certified company with over 75 years of industry experience designing and manufacturing temperature-controlled products of the highest quality, with a commitment to total customer satisfaction. At CSZ, we offer a complete line of both standard and custom-designed environmental simulation chambers including: Temperature Cycling HALT/HASS Humidity Freezers Stability Cabinets & Rooms Liquid Chillers Thermal Shock Wind & Rain Stress-Screening Sand & Dust Altitude Other Temperature AGREE Vibration Management Solutions Sizes range from benchtop to full walk-in/drive-in chambers. CSZ is your one stop solution for... Environmental Chambers Freezers System Upgrades Preventative Maintenance Calibration Services Contract Testing Services Testing Services CSZ Testing Services is an A2LA Accredited Test Laboratory utilizing the latest test technology. CSZ is your one stop source for all of your environmental simulation testing needs. Our testing laboratory is here to help with your product qualification testing, overflow testing and /or third party product validation. Testing capabilities include Temperature, Humidity, and/or Vibration, Thermal Shock, Burn-in, Radiator Testing, Altitude, Vibration, HALT/HASS, Shock, Salt Spray, and Cyclic Corrosion test. Serving you from two locations in Cincinnati, OH and Sterling Heights, MI. For more information please call CSZ Testing headquarters at 513-793-7774 or visit www.csztesting.com. Cincinnati Sub-Zero Products, Inc. 12011 Mosteller Road Cincinnati, OH 45241 (p) 513-772-8810 (f) 513-772-9119 www.cszindustrial.com Cincinnati Sub-Zero Products, Inc. 95027 12/15