Water-Cooled Screw Chiller

Similar documents
Absorption. LG HVAC Solution.

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

AIR-CONDITIONER SPLIT TYPE

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

USER S MANUAL HSC-24A

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1


DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Inverter Compressor Technology for Refrigerator. Reciprocating

ECOCIAT. Domestic hot water heat recovery unit

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

SECTION MORTUARY REFRIGERATORS

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43

york air-conditioning products Residential & VRF News 2015

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

AIR CONDITIONER INSTALLATION MANUAL

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

HVAC Systems: Overview

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Maintenance for Energy Efficiency

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Technical data. Danfoss DHP-A

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Hydraulic Control Solutions

RPV - RP - RA air handling units

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Local Dealer:

SWIMMING POOL HEAT PUMP

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Split units TH with hermetic compressors

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Air Conditioners Technical Data

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Failure code manual. content

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

SECTION GENERAL PROVISIONS FOR HVAC WORK

HEAVY DUTY STORAGE GAS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Cool Design for Homes and Offices

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Why and How we Use Capacity Control

Compressors, Chillers & Condensers

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Innovent LASER Packaged Fresh Air Conditioning Units

Direct Fresh Air Free Cooling of Data Centres

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Basic Hydraulics and Pneumatics

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Please keep these operating instructions in a safe place.

Rotary screw compressors kw 5,5 7, , bar MODULO

C18 ACERT Fire Pump Tier bkw/ rpm

Installation Manual CLIFC Fan & Coil Variable Speed

Lesson 36 Selection Of Air Conditioning Systems

MAC-120HE-01 Air-Cooled Chiller

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

300 Series PA Pump and Cooler Assemblies

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Commercial Gas Furnace Upflow

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

HP switch LP switch Discharge thermo Comp. Surface thermo

CB29M Bulletin # February 1996

YCAA-B AIR COOLED LIQUID CHILLER

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Installation and maintenance instructions. Danfoss Vent

A/C refrigerant system, overview

LG Electronics AE Company, Commercial Air Conditioning

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Chilled Water Precision Air Conditioner For Critical Application

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

ARMSTRONG AIR HEAT PUMPS

Glossary of Heating, Ventilation and Air Conditioning Terms

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Water-Cooled Screw Chiller. Service Manual. (T1/R22, R134a)

DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT)

SustainE(Sustainable Energy)

Powers Controls TH 192 S Single Temperature Room Thermostat

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Transcription:

Water-Cooled Screw Chiller A i r C o n d i t i o n i n g S y s t e m R134a 100 to 350RT

New Dream, New Start To become a leader in the competitive global market, LG has been divided into three groups, electronics and chemicals for LG, energy and machineries distribution for GS, Industrial electric electronic materials for LS based on their business specialties. LS' main companies, such as LS Mtron, LS cable, LS industrial systems, LS- Nikko copper, Gaon cable, E1 and Kukdong City gas, are ranked as No.1 in their respective industry. However, LS won't just sit back, satisfied with being the best in Korea. We will pave the way for becoming the world's best in Industrial electric electronics and material industry with the new CI, LS. Your best partner LS Cable is making a fresh start as LS Mtron LS Mtron is No.1 machinery maker in Korea and its business fields are components & materials and machinery. Also, LS Mtron is creating new businesses particularly in component and materials industry. LS Mtron makes its best to accomplish the vision, 'Your No.1 Creative Partner' and be one of the world leaders with high technology and best level of service. Research & Development Tractor Components & Materials Business Air-Conditioning System Injection Molding System

MAIN CHARACTERISTICS AIR CONDITIONING SYSTEM The high-performance screw chiller is designed depending on 30 years research & development experience of LS Air-Conditioning System. High-performance compressor manufactured by specialized manufacturer is adopted to ensure that the chiller is economical and durable with low vibration and low noise. The primary and secondary selection function the double-head chiller compressor evenly used and hence the service life of entire machine is prolonged. Highly integrated motherboard is adopted and hence the function is strong and reliable. Model description Advanced control algorithm is adopted to control chiller in advance and hence avoid frequent stoppage protection of chiller. We have set complete safety protection function in order to make chiller safely and reliably run. The linkage control and remote monitoring function of peripheral equipments ensure that the chiller can run safely and the operation and monitoring are convenient. The selection of excellent raw materials and fittings is the key to guaranteeing chiller quality. The product is divided into flooded screw chiller SFWW and dry screw chiller SWW. S F W W X X X S A S 3 Y S Model explanation Application : S-air-condition, L-low temperature Starting mode : S-direct start, Y-Y-, I-conversion start Power : 2-220V 50Hz, 3-380V 50Hz 4-440V 50Hz, 5-220V 60Hz 6-380V 60Hz, 7-440V 60Hz Unit type : E- conversion, N- external oil distributor S-Iinner oil distributor, M-downward film type Refrigerant : A-R134a Compressor No. : S-1set, D-2sets, T-3sets, F-4sets capacity : (RT) Evaporator : W-water cooled tube and shell type, P-plate exchanger Condenser : W-water cooled tube and shell type, P-plate exchanger evaporation mode : F-flooded Semi-closed screw chiller 320DAS-3YS This is a flooded double screw chiller which is Water-cooled,with R134a as refrigerant and made in LS Air-conditioning system (Shandong) Co., Ltd. It s nominal capacity is 320USRT 4

SPECIFICATION R134a (50Hz) MODEL UNITS 100SAS 110SAS 120SAS 140SAS 160SAS 180SAS 230SAN USRT 94.1 112.1 120.7 137.4 160.3 172.6 226.0 Capacity Kw 331.1 394.3 424.4 483.4 563.8 607.1 795.0 10 4 kcal/h 28.5 33.9 36.5 41.6 48.5 52.2 68.4 Power input kw 67.6 79.1 85.0 97.5 109.9 118.3 154.9 Power - 3PH-380V-50HZ Rated Current A 113.7 133.0 142.8 163.8 184.8 198.9 260.5 Comp. Starting current A 265.3 310.3 333.2 382.3 431.2 464.1 607.8 Number SET 1 Starting mode - Y- Cooling water Chilled water Dim. Weight Ref. Frozen oil T-Inlet /outlet C 32-37 Flow m 3 /h 69 81 88 100 116 125 163 Pressure kgf/cm 2 0.58 0.57 0.59 0.60 0.58 0.61 0.63 Diameter DN 100 100 100 125 125 125 150 T-Inlet/outlet C 12-7 Flow m 3 /h 57 68 73 83 97 104 137 Pressure kgf/cm 2 0.48 0.44 0.45 0.46 0.44 0.46 0.48 Diameter DN 100 100 100 125 125 125 150 L mm 4300 4300 4300 4326 4326 4326 4351 W mm 1521 1521 1521 1571 1571 1571 1627 H mm 1636 1749 1749 1815 1815 1815 1964 Transporting ton 2.4 2.8 3.0 3.5 3.5 3.6 4.1 Running ton 2.6 3.2 3.4 3.9 3.9 3.9 4.7 Weight kg 125 150 150 180 180 180 280 Type - R134a Volume L 18 23 23 28 28 28 95 Trademark - CP-solest-220 MODEL UNITS 270SAN 310SAN 190DAS 230DAS 250DAS 280DAS 320DAS 350DAS USRT 264.8 308.0 188.3 224.2 246.2 274.9 320.6 345.2 Capacity kw 931.5 1083.2 662.2 788.7 865.8 966.7 1127.5 1214.2 10 4 kcal/h 80.1 93.1 56.9 67.8 74.4 83.1 96.9 104.4 Power input kw 179.3 207.4 135.2 158.2 170.0 194.9 219.8 236.6 Power - 3PH-380V-50HZ Rated Current A 301.5 348.7 113.7*2 133.0*2 142.8*2 163.8*2 184.8*2 198.9*2 Comp. Starting current A 703.5 813.6 265.3*2 310.3*2 333.2*2 382.2*2 431.2*2 464.1*2 Number SET 1 2 Starting mode - Y- Cooling water Chilled water Dim. Weight Ref. Frozen oil T-Inlet /outlet C 32-37 Flow m 3 /h 191 222 137 163 178 200 232 249 Pressure kgf/cm 2 0.62 0.61 0.61 0.62 0.57 0.58 0.55 0.56 Diameter DN 150 200 150 150 150 150 200 200 T-Inlet/outlet C 12-7 Flow m 3 /h 160 186 114 136 149 166 194 209 Pressure kgf/cm 2 0.47 0.47 0.42 0.44 0.43 0.47 0.45 0.46 Diameter DN 150 200 150 150 150 150 200 200 L mm 4393 4393 4430 4430 4393 4393 4522 4522 W mm 1846 1846 1681 1681 1785 1785 1891 1891 H mm 2105 2105 1845 1845 1941 1941 1990 1990 Transporting ton 4.3 4.5 4.1 4.6 5.2 5.4 6.1 6.3 Running ton 4.9 5.1 4.4 4.9 5.6 5.8 6.5 6.7 Weight kg 280 280 210 210 245 245 290 290 Type - R134a Volume L 114 114 36 46 46 56 56 56 Trademark - CP-solest-220 1. 1RT = 3024kcal/h = 3.517kw, 1mH 2 o = 9.8kpa 2. Fouling factor of water in condenser and evaporator is 0.086m 2 k / kw 3. Maximum pressure of chilled water and cooling water system 10kgf/cm 2 4. Specifications subject to change without prior notice L S W A T E R - C O O L E D S C R E W C H I L L E R 5

SPECIFICATION R134a (60Hz) COMP. COOLING WATER CHILLED WATER DIM. WEIGHT MODEL UNITS 110SAS 130SAS 145SAS 165SAS 190SAS 200SAS CAPACITY USRT 110.9 132.1 145.1 167.0 188.9 203.4 kw 390.1 464.7 510.2 587.25 664.3 715.5 10 4 kcal/h 33.5 40.0 43.9 50.5 57.1 61.5 POWER INPUT kw 80.1 93.7 100.7 115.5 130.3 140.2 Power - 3PH-380V-60Hz Rated Current A 134.7 157.6 169.2 194.1 219.0 235.6 Starting current A 314.3 367.7 394.8 452.9 511.0 549.7 Number SET 1 Starting mode - Y-D T-Inlet /outlet C 32-37 Flow m 3 /h 81 96 105 121 137 147 Pressure kgf/cm2 0.80 0.84 0.90 0.79 0.82 0.91 Diameter DN 100 125 125 125 125 125 T-Inlet/outlet C 12-7 Flow m3/h 67 80 88 101 114 123 Pressure kgf/cm2 0.60 0.60 0.61 0.61 0.63 0.63 Diameter DN 100 125 125 125 125 125 L mm 4290 4290 4290 4290 4290 4320 W mm 1200 1200 1200 1300 1300 1400 H mm 1800 1850 1850 1900 1900 1900 Transporting ton 2.8 3.0 3.5 3.5 3.6 3.8 Running ton 3.2 3.4 3.9 3.9 3.9 4.2 REF. Trademark - R134a FROZEN OIL Volume L 18 23 23 28 28 28 Trademark - CP-solest-220 Comp. Cooling water Chilled water Dim. Weight MODEL UNITS 220DAS 260DAS 290DAS 330DAS 380DAS 410DAS Capacity USRT 221.8 264.3 290.1 333.9 377.8 406.9 Kw 780.2 929.4 1020.4 1174.5 1328.6 1431.0 10 4 kcal/h 67.1 79.9 87.7 101.0 114.2 123.0 Power input kw 80.1*2 93.7*2 100.7*2 115.5*2 130.3*2 140.2*2 Power - 3PH-380V-60Hz Rated Current A 134.7*2 157.6*2 169.2*2 194.1*2 219.0*2 235.6*2 Starting current A 314.3*2 367.7*2 394.8*2 452.9*2 511.0*2 549.7*2 Number SET 2 Starting mode - Y-D T-Inlet /outlet C 32-37 Flow m 3 /h 162 192 210 242 273 294 Pressure kgf/cm 2 0.84 0.85 0.89 0.86 0.89 0.91 Diameter DN 150 150 150 200 200 200 T-Inlet/outlet C 12-7 Flow m 3 /h 134 160 175 202 228 246 Pressure kgf/cm 2 0.63 0.65 0.65 0.66 0.66 0.67 Diameter DN 150 150 150 200 200 200 L mm 4320 4320 4470 4470 4650 4650 W mm 1400 1400 1580 1580 1700 1700 H mm 1950 1950 2010 2010 2040 2040 Transporting ton 4.6 5.2 5.4 6.1 6.5 6.5 Running ton 4.9 5.6 5.8 6.5 6.9 6.9 Ref. Trademark - R134a Frozen oil Volume L 36 46 46 56 56 56 Trademark - CP-solest-220 1. 1RT = 3024kcal/h = 3.517kw, 1mH 2 o = 9.8kpa 2. Fouling factor of water in condenser and evaporator is 0.086m 2 k / kw 3. Maximum pressure of chilled water and cooling water system 10kgf/cm 2 4. Specifications subject to change without prior notice 6

INSTALLATION AND DIMENSION Chiller room requirements The design and location of central air conditioner room is a comprehensive work, which must be closely coordinated with architecture, structure, water supply and drainage, building electricity and other professional work. 1. The air conditioner room should be located as near as possible to the cooling load center. For High-rise buildings with basement available for use, it should be located in the basement; for super high-rise building, it may be located at middle floor (technical equipment floor) in accordance with system division; for air conditioning modification or addition works, it may also be reconstructed outside air conditioning building or located at the roof or other place of air conditioning building, while it must be guaranteed that the building structures have enough bearing capability. 2. The equipments in the air conditioner room should be arranged closely to save covered building area. The equipment arrangement and pipe connection should accord with technological flow requirement and be easy to install, maintain and repair. 3. When the tube shell and the heat exchanger of chiller are arranged, the possibility to clean and replace tube nest should be considered. Generally, a space with length equal to chiller length will be left on one end of chiller. If there is no enough space, one end of chiller in the length direction may be directly faced to window with proper height for lighting or to gate with proper height. 4. The air-conditioner room should be made of Grade II refractory materials or incombustible materials with good sound insulation property. The room should have two exits as far as possible from each other, of which at least one should directly face to outside. Also, the direction of opening should be towards the outdoor. 5. please refer to Air conditioner Room Guaranteed Space for room height. 7. When the central air conditioner room is located in the basement, it Space between equipments in machinery room should be equipped with mechanical ventilating equipment and the least air displacement of such equipment should not less than 36.5G2/3(m3/H), where: G is the total cooling capacity of chiller. In order to reduce air displacement under non-emergency conditions, it is recommended to use multi-speed blower. The inlet and conduit of exhausting blower should be near to chiller with proper protection. 8. The central air conditioner room inside should be equipped with water discharging facilities and toilets and if available, with telephone. Also, emergency lighting should be taken into consideration. 9. The inflammable and explosive materials are not allowed to be stored in the air conditioner room except refrigerant existing in the chiller. Space between equipments in machinery room ITEMS SPACE (M) Width of main channel and operation channel >1.5 Distance between jut of chiller and switch-house >1.5 Distance between jet of chiller >1.0 Distance between chiller and wall >0.8 Width of subordination channel >0.8 Distance between side jut of the chiller >1.5 Distance between sides of absorption chill and wall >1.2 6. The host air conditioner in the central air conditioner room should be separated from pump room and control room and the repairing room and storage room should be arranged in accordance with practical conditions. If there are fuel absorption chiller or fuel central water heater in the air conditioner room, the idlest method is to obtain fuel from special oil depot through oil pipeline. If the fuel tank is placed in the room, then the floor arrangement should strictly follow relative fire codes and the house should be equipped with necessary fire-fighting equipments. L S W A T E R - C O O L E D S C R E W C H I L L E R 7

INSTALLATION AND DIMENSION Installation and size Installation requirements The installation space should be considered when the chiller are installed in order that LS service personnel are convenient to dismantle and hoist compressors and other parts. The minimum space can be determined in accordance with the table below. For multiple chiller, the space between two chiller should be not less than 120% that of single chiller. If the room space is too small, please contact LS for consultation and solution. During installation, special attention should be paid to : 1. The water pump should be installed on the side of inlet of cooled water/cooling water, if it needs to install on the outlet side, please contact LS. 2. The two sides of water pump should be installed with flexible connection to insulate pipe vibration. For water pump, the speed 2900RPM should be not chosen to the extent possible in case of resonance. TYPE MODEL A B C D E R134a (50Hz) R134a (60Hz) SFWW100SAS~SFWW120SAS 1500 3600 1500 1200 1000 SFWW140SAS~SFWW310SAN 2000 3600 2000 1200 1000 SFWW190DAS~SFWW350DAS 2500 2500 2000 1500 1500 SFWW110SAS~SFWW130SAS 1500 3600 1500 1200 1000 SFWW140SAS~SFWW360SAS 2000 3600 2000 1200 1000 SFWW220DAS~SFWW410DAS 2500 3600 2000 1500 1500 8

DIMENSION OF FLOODED TYPE SCREW CHILLER R134a(50Hz) - Single compressor series MODEL L W H E A B C D SFWW100SAS 4300 1521 1636 563 683 443 485 695 SFWW110SAS~120SAS 4300 1521 1749 613 650 410 510 700 SFWW140SAS~180SAS 4326 1571 1815 663 658 418 485 695 L S W A T E R - C O O L E D S C R E W C H I L L E R 9

DIMENSION OF FLOODED TYPE SCREW CHILLER R134a(50Hz) - Dual compressor series Model L W H E A B C D SFWW190DAS~SFWW230DAS 4430 1681 1845 718 730 430 550 830 SFWW250DAS~SFWW280DAS 4393 1785 1941 770 840 540 615 875 SFWW320DAS~SFWW350DAS 4522 1891 1990 823 840 490 567 867 10

DIMENSION OF FLOODED TYPE SCREW CHILLER R134a(50Hz) - Single compressor series MODEL L W H E A B C D SFWW230SAN 4351 1627 1964 718 730 430 550 830 SFWW270SAN~SFWW310SAN 4393 1846 2105 798 867 567 540 840 L S W A T E R - C O O L E D S C R E W C H I L L E R 11

DIMENSION OF FLOODED TYPE SCREW CHILLER R134a(50Hz) - Single compressor series MODEL L W H E A B C D SFWW110SAS 4290 1200 1800 613 625 385 668 792 SFWW130SAS~145SAS 4290 1200 1850 663 650 410 703 523 SFWW165SAS~190SAS 4290 1300 1900 663 673 433 728 518 SFWW200SAS 4320 1400 1900 718 700 450 750 530 12

DIMENSION OF FLOODED TYPE SCREW CHILLER R134a(50Hz) - Dual compressor series MODEL L W H E A B C D SFWW220DAS~SFWW260DAS 4320 1400 1950 718 730 430 833 650 SFWW290DAS~330DAS 4470 1580 2010 770 805 455 900 710 SFWW380DAS~410DAS 4650 1700 2040 823 805 455 900 755 L S W A T E R - C O O L E D S C R E W C H I L L E R 13

FOUNDATION R134a - Flooded screw chiller Notes: 1. Floor installation is the standard installation mode of chiller. For floor installation, the rubber shock pad along with the chiller should be installed. 2. For floor installation, please refer to building codes for floor requirements and fixation methods of foundation bolt. 3. Spring damper should be installed when the chiller floor is installed, which should be noted in the contract to purchase during purchase of chiller. 4. It should be guaranteed that the horizontal tolerance in the direction of the whole length and width of chiller should be less tan 3mm. 5. After the chiller is leveled, the respective space of each spring damper should be not less than 6mm. TYPE MODEL A B C D R134a (50Hz) R134a (60Hz) SFWW100SAS 4250 3824 1371 971 SFWW110SAS ~SFWW120SAS 4250 3824 1471 1071 SFWW140SAS ~SFWW180SAS 4250 3824 1571 1171 SFWW230SAN 4250 3824 1681 1281 SFWW270SAN~310SAN 4250 3824 1891 1491 SFWW190DAS ~SFWW230DAS 4250 3824 1681 1281 SFWW250DAS ~SFWW280DAS 4250 3824 1785 1385 SFWW320DAS ~SFWW350DAS 4250 3824 1891 1491 SFWW110SAS ~SFWW145SAS 4250 3824 1450 1017 SFWW165SAS ~SFWW190SAS 4250 3824 1550 1121 SFWW200SAS 4250 3824 1650 1225 SFWW220DAS ~SFWW260DAS 4250 3824 1650 1225 SFWW290DAS ~SFWW330DAS 4250 3824 1800 1385 SFWW380DAS ~SFWW410DAS 4250 3824 1900 1491 14

PIPELINE AND ACCESSORY FACILITIES Pipeline and accessory facilities Construction cautions 1. For parts outside broken line, the customers will independently prepare materials and carry out construction. 2. The water system pressure of evaporator and condenser of water chiller should be not more than 10kgf/cm2 and if so, the chiller is special type. 3. All chiller should be equipped with special water pump and cooling water pump to the extent possible. 4. The pipeline of cooled water and cooling water should be equipped with 10-mesh filter. 5. In order for convenient management and maintenance of chiller, the following devices should be installed besides stop valves which are installed on respective pipeline of inlet/outlet of cooler water and cooling water: (1) Install thermometer and pressure gauge near the inlet/outlet of cooler water and cooling water (2) Install exhaust valve on respective pipeline of cooler water and cooling water 6. The start and stop of peripheral equipments must be controlled by control system of water chiller to guarantee interlock protection. 7. The power line inducted into starting cabinet of each compressor and connecting wire of peripheral equipments will be supplied by users and please ask for electric diagram of water chiller from the Company during design and construction Electric wiring COM2 114 300 301 302 303 304 305 52CO 52C The wire between the starting cabinet and the major motor, the starting cabinet and control cabinet, the staring cabinet and electric actuating elements, the control cabinet and such sensors as pressure, temperature, etc have been connected when the chiller leave factory; the parts within the broken line in the field wiring diagram above will be supplied by the users. T2 224 223 T2 220 117 COM2 SW1 Notes : 1. The interlock contact of this part will be supplied by the users and it has no voltage (dry contact) and the maximum impedance is 100. 2. The contact of this part is used for starting/stopping peripheral equipments, which is lower than 250VAC 0.1A. 3. 250VAC 0.1A The contact of this part is used for indicating progressive running status, which is lower than 250VAC 0.1A. 4. The signal of this part will be supplied by the users. L S W A T E R - C O O L E D S C R E W C H I L L E R 15

www.lsaircondition.com Overseas Sales Office in Korea Air conditioning Overseas Business Dept. 6F Sungji Building, 1505-17, Gwanyang-dong, Dongan-gu, Anyang-si, Gyeonggi-do, Korea Tel. 82-31-450-3531~3538 Fax : 82-31-450-3540 Factory in China 266109, Yu-Huangling Industrial Area,Xiazhuang, Chengyang District, Qingdao, China Tel. 86-532-8096-5648 Fax. 86-532-8096-5688 Distributed by Specifications subject to change without prior notice. ACOS-01-3000-0901 / Printed in Korea