Leica DFC550. Top-Quality Digital Camera Technology for Professional Documentation. industry Division

Similar documents
Leica DFC450 & DFC450 C. Digital Microscope Cameras for Analysis and Documentation

Living up to Life. Leica LAS Live Image Builder Dynamic Software for Fast Widefield Imaging and Extended Depth of Focus

Living up to Life. Leica KL300 LED. Compact, modular cold light source for routine stereomicroscopes

A New Perspective On Things

Leica DMS1000 & DMS1000 B

Tandem Scanner. Leica TCS SP5 II: The Broadband Confocal High Speed and High Resolution All in One

Super Cool Sputter Coater

Leica Stereo Explorer. Visualizing and Analyzing Microstructures in 3D. Living up to Life

Bullets, documents, tools: Compare for yourself - with optimum precision

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

Basler scout AREA SCAN CAMERAS

Basler. Line Scan Cameras

AxioCam HR The Camera that Challenges your Microscope

Computer Specifications

Leica EM SCD500. High Vacuum Sputter Coater For Highest Resolution FE-SEM Analysis

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter

How To Use An Edge 3.1 Scientific Cmmos Camera

KS732 Family. Rev KS732. 1/3 CCD Color USB Camera

Basler pilot AREA SCAN CAMERAS

White Paper. "See" what is important

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

High Definition Imaging

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

SNC-VL10P Video Network Camera

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Industrial vision cameras CAMERA LINK DVI-D FULL HD CAMERA LINE

Basler. Area Scan Cameras

Leica EM ACE. New Generation Coaters

Leica Microdissection Objectives

Leica DM4 P, DM2700 P, DM750 P

Séries U3-CMOS. Nouvelles. Caméras Numériques USB3. Ultra rapides

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate

Leica StereoZoom line. Complete solutions for industry, laboratory and training

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Leica A60 S / Leica A60 F

Grasshopper3 U3. Point Grey Research Inc Riverside Way Richmond, BC Canada V6W 1K7 T (604)

Noise Monitoring Software, version 7.0 Types 7802 and 7840

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

HIGH-RESOLUTION LED MODULES PERFECT VISUAL SOLUTIONS

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

AxioCam MRm Pure Sensitivity

Basler dart AREA SCAN CAMERAS. Board level cameras with bare board, S- and CS-mount options

Basler IP Cameras. Superior image quality Industrial-grade reliability Megapixel High sensitivity CCD sensor technology Efficient H.

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Leica Map Start. Surface imaging and Metrology Software. The Extension for Leica Application Suite. Living up to Life

digital backs Cable free operation with all V System cameras including 202FA/203FE/205FCC cameras.

Network Camera SNC-P1

VarioCAM high resolution

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

The Universal DAQ Device. Connect and measure immediately!

scmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary

Image Lab Software for the GS-900 Densitometer

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Agilent Television Power Consumption Testing. Application Note

Leica Application Suite. System Requirements V3.8.0

ENGLISH VERSION. ueye LE. Your imagination is our challenge

How To Use The Dc350 Document Camera

QuickSpecs. Model. HP USB HD 720p v2 Business Webcam. Overview

Datasheet Preliminary

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

Data Sheet FUJITSU Thin Client FUTRO A300

G8-VOIPREC. VoIP Recording Card G8-VOIPREC. Datasheet

How To Use Bodescan For 3D Imaging Of The Human Body

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

AXIS 262+ Network Video Recorder

AN974 APPLICATION NOTE

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Baumer Industrial Cameras Innovative Vision Components for Automated Image Processing

ViewLinker USB 2.0 Graphics Adapter

ProScan DC Linear Servo Stage Technology

DeCyder Extended Data Analysis (EDA) Software

MIRAX SCAN The new way of looking at pathology

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

How To Use An Amd Ramfire R7 With A 4Gb Memory Card With A 2Gb Memory Chip With A 3D Graphics Card With An 8Gb Card With 2Gb Graphics Card (With 2D) And A 2D Video Card With

MONOCHROME RGB YCbCr VIDEO DIGITIZER

Vicon Flash Upgrade Software

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

If you are working with the H4D-60 or multi-shot cameras we recommend 8GB of RAM on a 64 bit Windows and 1GB of video RAM.

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

SABRE Lite Development Kit

IMAGING SOFTWARE. Image-Pro Insight Image Analysis Made Easy. Capture, Process, Measure, and Share

Transcription:

Leica DFC550 Top-Quality Digital Camera Technology for Professional Documentation industry Division

2 Top-Quality Digital Camera Technology for Professional Documentation The new Leica DFC550 digital camera offers excellent color reproduction and the highest resolution for all light microscope related contrast methods. Superior image quality and high flexibility are the outstanding features of this camera. With its high precision Microscanning and Co-site Color Sampling, the hermetically sealed, thermoelectrically cooled 1.4 megapixel color sensor generates an image resolution of up to 12.5 megapixels in true colors. The Leica DFC550 offers a high dynamic range at an excellent signal-to-noise ratio. The camera delivers precisely detailed digitized images, 14-bit per color channel. The sensor s selectable read out, 24.6 MHz for fast live mode and fast image rates of 12.3 MHz for more image data, combine an optimum workflow and top image quality in a single camera. Robust and reliable interfaces such as FireWire-B and C-mount offer easy adaptation of the Leica DFC550 to all current microscopes and PC s. Greater detail, more information excellent results under all microscopy conditions Flexible for all applications Users requiring the greatest detail from their images benefit from the high-quality resolution offered by the Leica DFC550: Up to 12.5 megapixels at a color depth of 42-bit RGB is possible as a result of 36 partial exposures. Now, even the subtlest structures and color shades can be visually observed and digitally recorded. The Leica DFC550 ensures pin-sharp detail without moiré effect, color fringing or blooming. In addition to all common microscope modes, such as incidental and transmitted light, the Leica DFC550 digital camera is ideal for weak fluorescence and poorly illuminated samples. With combined cooling from a Peltier element and fan, the camera s CCD sensor provides perfect image and color quality even from long exposures. The 2/3" CCD Sensor is encapsulated in a sealed nitrogen chamber to avoid condensation on the optics, even with difficult-to-image samples. The Leica DFC550 is designed for all common contrast, light and dark procedures in microscopy, as well as for difficult fluorescence imaging. A choice of recording modes and resolutions provide excellent image quality in all applications. Semiconductor inspection Fiber inspection Polarizing inspection Polarizing inspection Metallographic sample Metallographic sample

4 High-performance Leica LAS software Leica Application Suite (LAS) integrates Leica microscopes, macroscopes, digital cameras, and software into one common environment to provide an easy-to-use and consistent imaging solution with unrivalled performance. The versatility of LAS makes it suitable for a diverse range of life science and industrial applications such as materials quality control, pathology, pharmaceutical testing, and many more. LAS accelerates the visualization, enhancement, measurement, documentation, and archiving of digital images. This powerful software solution can control all functions of Leica compound microscopes, stereomicroscopes, and macroscopes. By providing all the necessary tools for the installed applications to communicate with each other and with peripheral devices connected to the computer, LAS simplifies routine and research analysis. Leica DFC550: Fast, full color live images for easy focusing and monitoring of the image composition. Many user selectable resolutions from super fast 5 5 binning up to 12.5 Mpixel multishot mode to suit all imaging requirements. Co-site Color Sampling and sub sample readout modes no color interpolation required for fast and absolutely clean true color images without moiré artifacts. Sensitive Sony CCD color sensor with high precision piezo micro scanner to capture the subtlest structures and color shades Single FireWire-B connection for data and power for ease of use and simple installation. Complete camera kit with FireWire-B-B cable and FireWire-B board no need for additional computer accessory (optional notebook kit available). Improved color calibration and color rendering for the most demanding applications in industry and life science when the highest color quality is needed. v Active peltier cooling system with sealed sensor chamber and fan to ensure the same image quality even with long exposure times. New low light image noise detection and reduction algorithm to further reduce noise in the live image at low illumination levels. High Dynamic Range (HDR) Mode in LAS to capture more details in delicate or challenging samples. w Easy and standard camera control panels to concentrate on sample setup and for the best focus position.

Leica DFC550 Top-Quality digital camera Technology for Professional Documentation Technical Details Digital camera Housing Size Weight Exposure Live image Cooling External manual trigger Flash synchronization Shading correction Sensor Leica DFC550 Aluminum die cast (L W H) 157 mm 93 mm 123 mm 800 g 0.25 milliseconds 600 seconds On computer screen Active (Peltier cooling), fan Present Present Present CCD sensor 2/3" CCD ICX285AQ Progressive scan Sensitive surface 8.8 mm 6.6 mm Pixel size 6.45 μm 6.45 μm Number of pixels 1360 pixels 1024 pixels, 1.4 Mpixels Total pixels (highest resolution) 4080 pixels 3072 pixels, 12.5 Mpixels Color filter RGB Bayer Signal-to-noise ratio 2050:1; 67 db (at 24.6 MHz readout clock) AD converter 14-bit Protective filter Hoya C-500S Binning mode 3 3, 5 5 Analogue gain 1 8 Resolution Live image speed IMAGE & File SIZE 272 204 (5 binning) 40 fps 0.06 MP 163 KB 340 256 (1 shot subsample) 56 fps 0.09 MP 256 KB 452 340 (3 binning) 30 fps 0.15 MP 450 KB 680 512 (2 shot subsample) 45 fps 0.35 MP 1 MB 1360 1024 (1 shot) 13 fps 1.4 MP 4 MB 1360 1024 (4 shot co-site color) 1.4 MP 4 MB 2000 1500 (9 shot subsample) 3.0 MP 9 MB 2720 2048 (16 shot co-site color) 5.5 MP 16 MB 4080 3072 (36 shot) 12.5 MP 36 MB Piezo-Shift Technology If the 4-shot capture mode is selected, the camera captures four images of the same object using pixel shifting technology. In between the single captures the complete CCD sensor is precisely shifted one pixel s width. Thereby each image point is captured once by a red, green, and blue pixel. The four images then combine to produce a true color image in the sensor s resolution, and complete color information is measured. As a result no color artifacts or aliasing will occur, and the color resolution is optimal. Single-shot mode: Left: part of the on-chip Bayer-type mosaic mask. Right: single-shot interpolation of missing green color information for a blue pixel by inspecting the neighboring pixels. 4-shot mode: 1. 2. Computer Supported operating systems PC Win XP, Win 7 Software PC DFC Twain, Leica LAS, Leica LAS-AF 3. 4. Interfaces Optical C-Mount Recommended video adapter 0.63 / 0.7 Data FireWire-B 9-pin single cable (400 MB/s) Power supply 12 33V via computer Power consumption 8 W Computer FireWire-B interface MISCELLANEOUS Minimum PC configuration Operating temperature range Air humidity Intel Core Duo >2.5 GHz, or Intel Core-i series 2 GB RAM, Graphics card 256 MB RAM, shared memory not recommended, powered FireWire-B onboard or 1 free PCI express slot +5 to +35 C max. 80%, non condensing True color by Co-site Color Sampling with 4-shot technique. Left: the true color image is combined from 4 single images. Right: shifting pattern for sampling color information. 36-shot mode: 36 1 2 3 4 5 6 Microscanning increases spatial and color resolution. Left: the first 6 out of 36 total images that will combine to create a high-resolution image. Right: shifting pattern for the 36-shot. The width of each single step is 1/3 pixel pitch.

www.leica-microsystems.com Assembly Diagram u DFC550 12 730 455 w Cables 12 730 186 FW-B-B, 2.5 m x FireWire-Cards 12 730 446 Notebook Kit FW-B 12 730 447 FW-B, PCI-Express Low Profile 11 541 510 1 11 541 543* 0.7 10 446 307 0.8 10 447 367* 0.63 Compound Microscopes Stereomicroscopes *recommended ORDER NUMBERS 12 730 455 Leica DFC550 Camera kit comprising: Leica DFC550 Camera, PCI-Express FireWire-B card, FireWire-B-B cable, 2.5 m, Leica software order numbers (Options/Extras) 12 730 447 x PCI-Express FireWire-B card for PCs without FireWire (2 ports) low profile 12 730 446 x FireWire-B notebook kit, comprising PCI-Express card (2 ports), power supply 100-240 V, FireWire-A-B adapter 12 730 186 w FireWire-B-B cable, 2.5 m, 9/9-Pin The statement by Ernst Leitz in 1907, With the User, For the User, describes the fruitful collaboration with end users and driving force of innovation at Leica Microsystems. We have developed five brand values to live up to this tradition: Pioneering, High-end Quality, Team Spirit, Dedication to Science, and Continuous Improvement. For us, living up to these values means: Living up to Life. Industry Division The Leica Microsystems Industry Division s focus is to support customers pursuit of the highest quality end result. Leica Microsystems provide the best and most innovative imaging systems to see, measure, and analyze the microstructures in routine and research industrial applications, materials science, quality control, forensic science investigation, and educational applications. Leica Microsystems an international company with a strong network of worldwide customer services: Active worldwide T tel. fax Australia North Ryde +61 2 8870 3500 2 9878 1055 Austria Vienna +43 1 486 80 50 0 1 486 80 50 30 Belgium Diegem +32 2 790 98 50 2 790 98 68 Canada Concord/Ontario +1 800 248 0123 847 405 0164 Denmark Ballerup +45 4454 0101 4454 0111 France Nanterre Cedex +33 811 000 664 1 56 05 23 23 Germany Wetzlar +49 64 41 29 40 00 64 41 29 41 55 Italy Milan +39 02 574 861 02 574 03392 Japan Tokyo +81 3 5421 2800 3 5421 2896 Korea Seoul +82 2 514 65 43 2 514 65 48 Netherlands Rijswijk +31 70 4132 100 70 4132 109 People s Rep. of China Hong Kong +852 2564 6699 2564 4163 Shanghai +86 21 6387 6606 21 6387 6698 Portugal Lisbon +351 21 388 9112 21 385 4668 Singapore +65 6779 7823 6773 0628 Spain Barcelona +34 93 494 95 30 93 494 95 32 Sweden Kista +46 8 625 45 45 8 625 45 10 Switzerland Heerbrugg +41 71 726 34 34 71 726 34 44 United Kingdom Milton Keynes +44 800 298 2344 1908 246312 USA Buffalo Grove/lllinois +1 800 248 0123 847 405 0164 10IDC19010EN Leica Microsystems (Switzerland) Ltd CH-9435 Heerbrugg, 2012 Printed in Switzerland V.2012 galledia Illustrations, descriptions and technical data are not binding and may be changed without notice. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.