Water Wash Booths. Dynaprecipitor/EnviroTect /No Pump GLOBAL FINISHING SOLUTIONS

Similar documents
Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Water Wash Spray Booth Paint Sludge Recovery

MUELLER FALLING FILM CHILLERS

Downflo workstation DuSt ColleCtorS

Spray Booth Guideline

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

FLASH TANK ECONOMIZER PRODUCT GUIDE

IBC Tote Containment Sumps

A Guide to Trouble-Free Cooling Towers

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Mechanical Rooftop Custom Capabilities

Cooking at the Speed of light!

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Fire Pump Plan Review March 2010

Airless Spray Coating Technology Including Air-Assisted Airless Spray Technology

Grit Removal Systems Simple, low cost, effective grit removal to enhance plant performance

Cooktop Low-Profile Ventilation Hoods

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Filter Aid Filtration

TOP 10 NOISE CONTROL TECHNIQUES

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Commercial Gas Water Heaters

Air Eliminators and Combination Air Eliminators Strainers

Element D Services Plumbing

Element D Services Heating, Ventilating, and Air Conditioning

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Filtration Guide. Introduction. Benefits of Clean Water

Installation Manual CLIFC Fan & Coil Variable Speed

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Cost-effective solutions for all applications.

Innovent LASER Packaged Fresh Air Conditioning Units

Centrifugal Fans and Pumps are sized to meet the maximum

Chemical Fume Hoods. Environmental Health and Safety

Select Radiators Installation Guide

ARTS AND CRAFTS (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

Laminar Flow Cabinets

ColorMax E Engineered Powder Spray System

Installer s Guide 18-AH39D1-13

Class A Foam Mixing and Application Equipment

Spetec. Laminar Flow Box. Portable Clean Room Technology

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

PUBLIC RESTROOMS, DESIGN INTENT

Drum Dispensing Stations

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

In-Line Air Separators

Domino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD

Oil Interceptors. The Most Effective Way to Remove Oil and Grease From Water

Standard Hydraulic Piping Flushing Procedure

DRYER VENTING SPECIFICATIONS DRYER SAFETY

EMERGENCY VAPOR SCRUBBER SYSTEMS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

PLUMBING & CROSS-CONNECTION CONTROL

CITYPLEX TOWERS BOILER INSTALLATION ORU RFP-1138

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III

Rotary screw compressors kw 5,5 7, , bar MODULO

Operation & Maintenance Manual

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Automatic Fire Sprinkler Submittal Requirements

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Desiccant Air Dryers Heatless, Heated and Heated Blower

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

FIRE DAMPER APPLICATION GUIDE

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Commercial Gas Furnace Upflow

Most agencies think about cleaning because of debris in the line.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

AIRLESS SPRAY SYSTEMS

Optimizing Tank Cleaning Operations

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Operating, Installation, and Maintenance Instructions

NFPA Combustible Dust Compliance and the Industrial Ventilation System

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

F-900 HOPEC Bench Hood Framed Vertical Sash

CENTRIFUGAL DRYERS JUNE 2013 GALA INDUSTRIES, INC.

Firefighter Review. Instructor Guide

During Various Aluminum Fabricating Operations

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

DESIGN, TESTING, AND OPERATING EXPERIENCE OF A SALTWATER DISPOSAL SYSTEM OIL-WATER SEPARATOR

Fiberstars Mini Lighted Laminar Flow Fountains

Transcription:

Dynaprecipitor/EnviroTect /No Pump Your spray booth is a considerable investment. The return on your investment is a cleaner painting environment for superior quality finishes, increased productivity, and improved working conditions. 800-88-878 Efficient Airborne Particulate Removal High Volume Capture Efficiency Water Wash Scrubber with Enhanced Impingement Technology Time-Tested Design for Over Fifty Years

DYNAPRECIPITOR WATER WASH SPRAY BOOTHS Global Finishing Solutions (GFS) Dynaprecipitor Water Wash Spray Booth handles a larger variety of paints in a wider range of viscosities and drying speeds, at higher production rates than any of the conventional spray booths. This booth employs two well-known engineering principles to remove paint particles from exhaust air in painting operations. First, by drawing air through a continuous curtain of moving water, suspended paint particles are scrubbed out. Second, when air carrying paint particles makes a sudden change in direction of flow, centrifugal force slings the solid particles out of the air stream (called impingement). Entrained paint particles are thrown against adjacent walls and curtains. Water then flushes the particulate into the collecting pan. Through these two actions the air reaching the exhaust stack is virtually free of airborne particles keeping the stack area cleaner longer. A Upper Centrifugal Wash Chamber: Here, most of the paint particles are separated from the exhaust air. This separation is accomplished by centrifugal force on the paint particles as the air abruptly changes direction of flow while simultaneously being forced to pass through powerful water sprays. Tube Axial Exhaust Fan Access Door A B Lower Wash Chamber: In the lower wash chamber, the exhaust air must pass through an unbroken curtain of water. Again, water scrubbing and centrifugal force combine to remove the remaining paint particles before the air passes to the exhaust chamber. Air flow through a typical Dynaprecipitor Water Wash Booth. B C Water Level C Recessed Drain: The recessed drain supplied insures complete removal of water from the collecting pan. This feature simplifies the cleaning operation. Standard Features These booths are constructed of 8-gauge galvanized panels for field assembly: > An upper and lower wash chamber > Large capacity collecting pan > Slotted water intake pipe to ensure sediment free water > Circulating water to maintain a constantly flushed system > Removable manifold for easy maintenance > Hinged water curtain to allow easy access to the rear of the collecting pan > Access door located just below the fan for easy maintenance > External float box with level control Space Saver: The booth saves floor space. Its short-depth wash unit gives water-wash-spray-booth advantages while occupying conventional booth space. Easy Maintenance: Hinged front water curtain permits easy skimming of coagulated paint particles from collecting pan. Optional automatic centrifugal separators are available. Circulating System: Circulating water forms a continuous, constantly flushed system that has no sediment-accumulating dead ends. Rate of water flow is quickly adjustable. An automatic water level control supplies make-up water to compensate for slight daily evaporation loss. NOTE: Check with local codes for disposal. Dynaprecipitor is a registered trademark of GFS. The wash water should be treated (compounded). This causes the paint particles to coagulate and allows convenient skimming when cleaning out the collection pan. GFS recommends that the end user enlist the support of an experienced chemical supplier that will provide the paint testing required to support the chemical treatment for controlling the ph, foaming and detactifier agent to enhance the performance of the water wash equipment. Correctly engineered water wash spray booths provide an extremely efficient means for removing paint particles from the exhausted air. In addition, they are the most acceptable type of spray booth for all health, fire, and building codes. Custom Enclosed Dynaprecipitor Water Wash Booth

STANDARD MODELS Depth Height Depth WWDE-060706 0'-" '-" 0 " (MPA)* 8 WWDE-00706 0'-0" 0'-" '-" 870 0 WWDE-0708 '-0" 7 Ft. Height WWDE-0708 WWDE-60708 WWDE-80708 WWDE-00708 '-0" 0'-0" 0'-" 0'-" 0'-" 0'-" 0'-" 0'-" '-" 7000 000 000 HP GPM HP 0 70 () () 6" () 8 700 Pump Diameter " Fan and Motor 96 08 6 () 8 Light Fixtures WWDE-060806 0'-" '-" 6000 " 8 WWDE-00806 0'-0" 0'-" '-" 0000 0 WWDE-0808 '-0" 000 WWDE-080806 8 Ft. Height Overall Dimensions Width WWDE-080706 WWDE-0808 WWDE-60808 WWDE-80808 WWDE-00808 WWDE-08006 0 Ft. Height Working Dimensions Air Flow SCFM @. SP Model No. '-0" 0'-0" 0'-" 0'-" 0'-" 0'-" 000 6000 6" 6" () 0000 () 0000 '-0" 0'-" 000 6" 0'-0" 0'-" 0'-" 0'-" 0'-" 0'-" '-" 00 700 0000 00 000 Front Elevation 8000 Note: Contact GFS for Conveyor Type Models 8 8 96 08 6" 0 () 08 () 6 () 96 () " 8 0 0 () () 6 8 * Medium Pressure Axial Working Width - Float Box Clearance Working Height Overall Clear Height Side Elevation Standard Pump Location (Right-hand Side) 800-88-878 '-" '-0" WWDE-0008 0'-" 8000 0'-" WWDE-008 WWDE-8008 '-" 0'-0" WWDE-6008 0'-" WWDE-0006 WWDE-008 Working Depth - Overall Tank Depth Overall Depth

NO PUMP WATER WASH SPRAY BOOTHS NO PUMP Spray Booths Features: Without benefit of pump or water-spraying manifold, GFS NO PUMP SPRAY BOOTH uses the highly effective scrubbing action of a water wash to separate paint particles from exhaust air. By ingenious channeling of the paint-laden exhaust air through a water tunnel the NO PUMP system eliminates pumps, piping, filters, manifolds, and nozzles. > and gauge galvanized welded washer assembly. How It Works Paint-laden air is drawn into the washing chamber at high velocity through an opening between the entrainment plate and water surface. The controlled dimension of this opening and the specially designed profile of the entrainment plate force the high velocity air to become severely turbulent, splash up water, and become thoroughly mixed with the overspray. > Standard panel work area enclosure, 8 gauge galvanized. > Automatic water level control for maintaining air velocity through entrainment plate gap to within + %. > Low sound, high efficiency mixed flow in line fan. > Inside-accessible ETL-listed -tube light fixtures (includes color corrected T-8 tubes). > Wash chamber works equally well in both Crossdraft and Downdraft booth configurations. > Access door located on back wall for inspection and fan maintenance. > External float box with level control. Exhaust Stack Water Treatment Distribution Plate Baffles Precise Water Level Control Entrainment Plate Collector Pan Trough Water Tank Next, this rapidly moving mixture of air, paint particles, and water droplets strikes the distribution plate. The mixture is forced to change direction abruptly and to flow upward through a series of baffles. The mixture flow changes direction times during its passage through the baffle section. At each change centrifugal force separates air from paint particles and from water droplets. The resulting rain of water, particularly from the lower baffles, serves as an additional water curtain for scrubbing the incoming spray laden air. All of the paint spray that is separated from the air falls back into the water tank. The water in the tank should be treated with the proper compound to suit the material being sprayed in order that the paint particles be made non-tacky and settle to the bottom of the tank where they agglomerate as a soft, foamy residue. Residue buildup may approach to within inches of the water surface without adversely affecting the NO PUMP action in the water tunnel. Residue removal is very infrequent, even in high production painting. Optional automatic centrifugal separators are available. The gap between the water surface and entrainment plate is kept with + % of its optimum dimension. This is accomplished with a GFS Float Box with Water Level Control Unit. This unit is located outside the booth proper - isolated from contaminating water and spray. Yet it is directly connected hydraulically to the water tank and senses water level changes immediately and accurately. Its external location gives it maximum accessibility for inspection and calibration. Easy Assembly NO PUMP washer is shipped in major all-welded sections for ease of field assembly: Pan, Wash Chamber, and Booth Adapter (Closure Panels).

STANDARD MODELS 7 Ft. Height Fan & Motor Width Depth Height Depth WWNP-060706 '-8 /" '-" 0 " 7 / 0" WWNP-00706 0'-0" '-" '-" 870 0" 0 " WWNP-0708 '-0" WWNP-080706 WWNP-0708 WWNP-60708 WWNP-80708 WWNP-00708 '-0" 0'-0" '-8 /" '-6 /" '- /" '-6 /" '-" '-" 7000 000 000 0 Diameter HP Duct Diameter 6" 0 " " " " 6" 6" 70 8" () 0 () " () 700 0" () 0 () " () Light Fixtures WWNP-060806 '-8 /" '-" 6000 " 7 / 0" WWNP-00806 0'-0" '-6 /" '-" 0000 " 0 6" WWNP-0808 '-0" '- /" 000 '-" WWNP-080806 8 Ft. Height Overall Dimensions Air Flow SCFM @." SP Model No. WWNP-0808 WWNP-60808 WWNP-80808 WWNP-00808 WWNP-08006 0 Ft. Height Working Dimensions '-0" 0'-0" 000 0 " " " 6" 6000 8" () 0 () " () 0000 " () 0 () 6" () 8000 0" () 0 () " () '-6 /" '-" 0000 " 0 6" '-0" '- /" 000 " 0 0'-0" '- /" '-" '-6 /" '-6 /" '-6 /" 8" '-6 /" '-0" WWNP-0008 8000 WWNP-008 WWNP-8008 '-6 /" '-" 0'-0" WWNP-6008 WWNP-0006 WWNP-008 '-" 00 700 0" () 0 () " () 00 " () () 6" () 0000 " 000 " () 0 () " () () 6" () 6" () Note: Contact GFS for Conveyor Type Models Front Elevation Working Width - Float Box Clearance Working Height Overall Clear Height Side Elevation Working Depth - Overall Tank Depth Overall Depth Float Box and Access Door Clearance 800-88-878

GLOBAL FINISHING SOLUTIONS Custom ENVIROTECT Unique Patented Technology > EnviroTect meets the highest production needs > Proven track record for over three decades EnviroTect washer section employs a built-in trough which provides an initial wetting action on the particulates. This enables the EnviroTect booth to perform efficiently with even the most difficult coating materials. Straight line, non-turbulent air flow through this spray curtain improves paint particulate capture and cleaning action while reducing energy consumption. EnviroTect water wash booth are custom booths, please contact GFS for ordering information. Exhaust Stack Baffles Liquid Supply Separation Chamber Air / Liquid Nozzle Floor Grating EnviroTect Trough Water Level Water Wash with a Difference Air/liquid nozzles are spaced as necessary depending on production and air volume requirements. Interior surfaces are wetted to eliminate paint overspray build-up which reduces booth cleaning and captures the paint within the eliminator for removal. Floor Grating Horizontal Flood Sheet Air/Liquid Nozzles For illustration purposes floor grating was removed 6

EnviroTect Specifications EnviroTect F7 EnviroTect F0 This model of water wash spray booth is for standard industrial applications. It is rated as passing less than grains solids per 000 CFM*. The F7 water wash can be used to convert existing booths and could use the existing fan and pump, this model also features reduced energy requirements. This model of water wash spray booth is a high efficiency booth for heavy industrial painting. It is rated as passing less than grains solids per 000 CFM*. Vertical Flow Models > Static Pressure: WC Vertical Flow Models > Air Nozzle Diameter: minimum I.D. > Static Pressure:. WC > Air Nozzle Diameter: 7 minimum I.D. > Liquid Nozzle: 0 GPM > Liquid Nozzle Pressure: psi > Liquid Nozzle: 0 GPM > Liquid Nozzle Pressure: psi > Air and liquid nozzles are made of 6 stainless steel > Air and liquid nozzles are made of 6 stainless steel * Based on handling 000 CFM of contaminated air per Air/Liquid Nozzle and using chemically compounded water as the wash medium. CUSTOM ENGINEERING GFS engineers will work with you to adapt our water wash spray booths to your requirements. Whether your requirements are new or you want to convert to a more efficient system, GFS engineers can help you make the right decision. Backed by a company with over 8 years experience...gfs knows the finishing business. As a purchaser of a GFS water wash system, you are assured complete servicing by trained and experienced personnel. Contact GFS for your custom ordering information. Custom Conveyorized Ordering Notes (Applies to all Models):. Wash chamber works equally well in both Crossdraft and Downdraft booth configurations.. Right side water level control valve and drain outlet are standard. Left side and Rear are available on special order, contact GFS for pricing.. Top exhaust is standard. Consult GFS if more than feet of exhaust duct is required.. Outside mounting of exhaust blower on heavy gauge steel stack available on special order, contact GFS.. TEFC motors are standard. Motor starters and explosion-proof motors are available, contact GFS for pricing. 6. Chemically treated water will remove the paint from the water to a collection unit for removal (optional.) Not supplied by GFS, contact local compounds supplier. 800-88-878 7

All designs, specifications and components are subject to change at the manufacturer s sole discretion at any time without notice. Data published herein is informational in nature and shall not be construed to warrant suitability of the unit for any particular purpose as performance may vary with the conditions encountered. 800-88-878 info@globalfinishing.com WWW.GLOBALFINISHING.COM 0 Global Finishing Solutions. All Rights Reserved. WATERWASH 000 8