Single Loop Controller SDC25/26



Similar documents
DIGITRONIK Digital Indicating Controller SDC10. User s Manual

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

+ A B V B NO NC V COM PV PV

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Safety technique. Emergency stop module BO 5988 safemaster

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multipoint Temperature Controller E5ZE

Temperature Controller USER S MANUAL

Radiant Temperature Sensor TY7321

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

SR1, SR3 Series Digital Controller Instruction Manual

Digital input modules

User Manual Auto Tuning PID Temperature Controller

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

38 Series - Relay interface modules A

CQM1-SF200/CS1W-SF200

Cross-beam scanning system to detect slim objects. 100 mm in

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Multifunction devices

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Control Devices The European Product Catalogue 2007

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Adjustment functions for both span and shift have been incorporated

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS

Absolute Rotary Encoder E6CP

38 Series - Relay interface modules A

Thyristor-controlled power supplies and battery chargers

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Solid-State Timer H3G

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

DC DC DC DC1040

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

How To Read A Pipe From A Sensor

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

ACS-30-EU-EMDR-10-MOD

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Energy Management Power Analyzer Type WM14-96 Basic Version

Smart DeviceNet Remote I/O Terminals

Duct Humidity Transmitter

Circuit Breakers. NRC Series. NRC Series

RY2 miniature industrial relays

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

NC-12 Modbus Application

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

NX safety stand-alone

Drayton Digistat +2RF/+3RF

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485.

INITIAL SETTING MANUAL

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

40.3. Control Relays and Timers

PNOZsigma - Base units

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Single Channel Loop Detector

Temperature & Humidity SMS Alert Controller

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Programming Logic controllers

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Telefon (+45) Telefax (+45) Installation and operating manual

WIND Power Technology: IMD Integrated Motor Drive

RM4TG20 three-phase network control relay RM4-T - range V

TX OPEN RS232/485 module

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

PX-series digital temperature controller Example of Applications and Parameter Functions

Power Supplies 3. SDN-P DIN Rail Series

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Telephone- and leased line modem for industrial applications TD-36

Liquid Leakage Sensor Amplifier

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Transcription:

No. CP SS 89E Single Loop Controller SDC5/6 Features The DigitroniK SDC5/6 is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP" and "Just- FiTTER". Up to two control output points (this number of points may vary depending on the model) can be used, which are selectable from the relay contact, voltage pulse, and current. The smart loader package ensures easy setting operation and monitoring. This controller is compliant to the IEC directives and the CE marking. Space saving design with a depth of 65mm. The mask of the front panel is also only 5mm thick. High accuracy of ±.%FS and sampling cycle of.s (seconds). Multi-range inputs are available for selection, where the input type can be freely changed among thermocouple, RTD, current, and voltage. The control method can be selected from any of the / OFF control and PID control using "RationaLOOP" + "Just-FiTTER". The heat/cool control can be achieved using two control output points and event outputs. The PC loader port is provided as a standard function. The control output types available for selection are relay, voltage pulse, and current outputs. The heat /cool control can be achieved by interfacing with the nd control output in combination with these outputs. Event points or points (independent contact), CT input points, DI 4 points, and RS-485 can be selected in combination. The smart loader package (SLP-C5) can be used. Basic Function Block of SDC5/6 Process variable () input External switch input (4 points) Thermocouple, RTD, linear (current, voltage) input value correction value filter value ratio Set point () value, 4 groups of selections AUTO/MANUAL selection RUN/READY selection Latch cancellation, etc. Current transformer (CT) input ( points) Control operation Either of /OFF control or PID control is selected. Direct/ Heat/Cool operation Relay contact Voltage pulse output Current output Above outputs are combined. upper limit, lower limit, upper/lower limit Deviation upper limit, lower limit, upper/lower limit upper limit, lower limit, upper/lower limit upper limit, lower limit, upper/lower limit Heater burnout, etc. to ma 4 to ma Control () output ( points) Event output ( points) Auxiliary output Communication input/output RS-485 (-wire) Personal computer loader Loader communication Power supply to 4Vac 5/6Hz * 4Vac/4Vdc Units marked with an asterisk (*) will be available in the near future.

Specifications input Input type Multi-range of inputs - thermocouple, RTD, DC current and DC voltage Input sampling time.s Input bias current Thermocouple input:.µa or less RTD input: ma typical DC voltage input: V range or less... µa or less (Note ) to 5V, to 5V range....5µa or less RTD or A-wire burnout: to V range... 7µA or less Upscale + AL Burnout Thermocouple input: Upscale + alarm display RTD input: Upscale + alarm display (Note ) B-wire or C-wire burnout: DC voltage input: Upscale + alarm display (However, the burnout cannot be detected Upscale + AL, More than -wire burnout: for the to V range.) DC current input: Upscale + alarm display Upscale + AL (However, the burnout cannot be detected for the to ma range.) Indications, indication method 4-digit, 7-segment LED (: Upper green display, : Lower orange display) and setting Number of setting points Max. 4 points Setting range Lower to higher limit value of the range ( upper/lower limit available) Multi-status indicator The control output status, alarm or RUN/READY status is indicated. Indication accuracy ±.%FS± digit In the negative area of the thermocouple, the accuracy is ±.6%FS± digit (at an ambient temperature of ± C.) Indication range See Table. Control output Output type Relay contact Voltage pulse Current Control action proportional PID proportional PID Continuous PID Number of PID groups Max. 4 groups Max. 4 groups Max. 4 groups PID auto-tuning Automatic PID value setting by limit cycle method. However, one of the following control characteristics can be selected: Standard Quick disturbance response Less up/down fluctuations Output rating NO side: 5Vac/Vdc, Open terminal voltage: Output type: A (resistive load) 9Vdc±5% to madc or 4 to madc NC side: 5Vac/Vdc, Internal resistance: 8Ω±.5% Allowable load resistance: A (resistive load) Allowable current: Max. 4mAdc Max. 6Ω Service life: Min. OFF/ time: Output accuracy: ±.%FS NO side: 5, cycles or more When s or less: ms (However, ±%FS for to ma) NC side:, cycles or more When to 9s: Cycle time x ms Min. opening/closing time: 5ms When s or longer: 5ms Cycle time (s) 5 to.,.5,.5, to PID control Proportional band (%FS). to 999.9 Integral time (s) to 9999 Derivative time (s) to 9999 Manual set (%) -. to +. Just-FiTTER Overshoot suppression coefficient to /OFF control Operating differential ( C) to 9999 digit Control operation selection or reverse action (However, reverse action only for heat/cool control) Heat/Cool control selection Control output and event output, auxiliary output Auxiliary Output type to madc or 4 to ma output Load resistance Max. 6Ω Output accuracy ±.%FS (However, ± digit for to ma) External Number of inputs Max. 4 points contact input Function Up to 4 kinds of setting value () selections, PID group selection, RUN/READY selection, AUTO/MANUAL (DI) selection, Auto tuning stop/start, Control action Direct/Reverse selection, ramp enable/disable, value hold, Max. value hold, Min. value hold, r start/stop, All DO latch cancellation Input rating Min. detection holding time.6s or longer Allowable contact Max. 5Ω resistance Non-voltage contact or open collector Allowable OFF contact Min. kω resistance Allowable -state Max..V residual voltage Open terminal voltage 5.5Vdc±V terminal current Approx. 7.5mA (at short-circuit), Approx. 5.mA (at contact resistance of 5Ω)

Event Number of output points to points (according to a model) Number of internal Up to 8 settings event settings Event type high limit low limit shows that the / this value. shows that the / a point that "U" is added to this value. high/low limit Deviation high limit + + Deviation low limit Deviation high/low limit + + high limit low limit high/low limit high limit low limit high/low limit Heater burnout/over-current Heater short-circuit CT at output CT at output CT at output OFF CT at output OFF

Event Event type Loop diagnosis shows that the / this value. shows that the / a point that "U" is added to this value. The event is turned when any change in corresponding to increase/decrease in (Manipulated variable) is not observed. This event is used to detect any fault of final control devices. Setting items : (Manipulated variable) : delay time: Diagnosis time Operation specifications The event is turned when the value does not reach the set in the sub-setting within the diagnosis time ( delay time) even though the exceeding the main setting is held. CAUTI When setting the delay, it is necessary to put in "Multi-function setup". The default setting of the delay before shipment is.s. Heat control Cool control conditions conditions conditions Area satsifying conditions delay EV On delay is started when conditions and are saisfied. delay EV delay is started when conditions and are satisfied. Loop diagnosis The event is turned when any change in corresponding to increase/decrease in (Manipulated variable) is not observed. This event is used to detect any fault of final control devices. Setting items : (Manipulated variable) : Change in from the point that the exceeds the main setting. delay time: Diagnosis time Operation specifications The event is turned when the exceeding the main setting is held (conditions ) and the does not reach the value that the sub-setting is added to (subtracted from) the at the point where the exceeds the main setting within the diagnosis time ( delay time) (conditions ). CAUTI When setting the delay, it is necessary to put in "Multi-function setup". The default setting of the delay before shipment is.s. Heat control Cool control to be used as reference conditions ( or more) to be used as reference conditions ( or more) conditions conditions delay EV delay is started when conditions and are satisfied. delay EV delay is started when conditions and are satisfied. 4

Event Event type Loop diagnosis shows that the /. this value. This event is used to detect any fault of final control devices. shows that the / a point that "U" is added to this value. The event is turned when any change in corresponding to increase/decrease in (Manipulated variable) is not observed. Setting items : Change in from the point that the reaches the upper limit (%) or lower limit (%). : Range of absolute value of deviation ( ) allowing the event to turn OFF. delay time: Diagnosis time OFF delay time: A period of time from power allowing the event to turn OFF. Operation specifications The direct action is used for the heat control. The event is turned when the increase in becomes smaller than the main setting after the diagnosis time ( delay time) has elapsed from the time that the had reached the upper limit, or when the decrease in becomes smaller than the main setting from the time that the diagnosis time ( delay time) has elapsed from the time that the had reached the lower limit. The reverse action is used for the cool control. The event is turned when the decrease in becomes smaller than the main setting after the diagnosis time ( delay time) has elapsed from the time that the had reached the upper limit, or when the increase in becomes smaller than the main setting after the diagnosis time ( delay time) has elapsed from the time that the had reached the lower limit. The event is turned OFF regardless of other conditions when the absolute value of the deviation ( ) becomes less than the sub-setting. The event is turned OFF regardless of other conditions when a period of time after starting of operation from the time that the power has been turned becomes less than the OFF delay time. However, the event is turned OFF when the absolute value of the deviation is the (sub-setting hysteresis) value or less after the absolute value of the deviation has become the sub-setting or more. CAUTI When setting the delay and OFF delay, it is necessary to put in "Multi-function setup". The default settings of the delay and OFF delay before shipment are.s. Heat control Cool control to be used as reference conditions to be used as reference conditions ( or more) Main setting ( or more) to be used as reference conditions ( or more) ( or more) conditions ( or more) to be used as reference Upper limit Lower limit conditions conditions delay delay EV delay is started when conditions and are satisfied. Upper limit Lower limit conditions conditions delay delay EV delay is started when conditions and are satisfied. alarm (status) if alarm (alarm code AL to 99) occurs, OFF if alarm (alarm code AL to ) occurs, OFF in other cases. in other cases. READY (status) in the READY mode. OFF in the READY mode. OFF in the RUN mode. in the RUN mode. MANUAL (status) in the MANUAL mode. OFF in the MANUAL mode. OFF in the AUTO mode. in RUN mode. During AT (Auto tuning) while AT is running. OFF while AT is running. OFF while AT is being stopped. while AT is being stopped. During ramp during ramp. OFF during ramp. OFF when ramp is not performed or is completed. when ramp is not performed or is completed. Control operation (status) during direct action (cooling). OFF during direct action (cooling). OFF during reverse action (heating). during reverse action (heating). ST (Smart Tuning) setting standby (status) in the ST setting standby. OFF in the ST setting standby. OFF in the ST setting completion. in the ST setting completion. 5

Event Event type r (status) shows that the / this value. shows that the / a point that "U" is added to this value. The direct and reverse action settings are disabled for the timer event. When using the timer event, it is necessary to set the operation type of the DI allocation to "r Start/Stop". Additionally, when setting the event channel designation of the DI allocation, multiple timer events are controlled from individual internal contacts (DI). Setting items delay time: A period of time necessary to change the event from OFF to after DI has been changed from OFF to. OFF delay time: A period of time necessary to change the event from to OFF after DI has been changed from to OFF. Operation specifications The event is turned when DI continues for delay time or longer. The event is turned OFF when DI OFF continues for OFF delay time or longer. In other cases, the current status is continued. DI delay OFF delay Internal event CAUTI When setting the delay and OFF delay, it is necessary to put in "Multi-function setup". The default settings of the delay and OFF delay before shipment are.s. The default setting of the event channel designation of the DI allocation before shipment is "". In this case, the timer event start/stop can be set for all internal events from one internal contact (DI). Additionally, as one or more event channel designation is set, the timer event start/stop can be set for one internal event specified by one internal contact (DI). However, when setting the event channel of the DI allocation, it is necessary to put in "Multi-function setup". Direct/, standby, and READY operations can be set when setting up each event (E.C to E5.C). Operating differential to 9999 digit Output operation /OFF operation Output type ST relay contacts, Common for points/independent contact for points Output rating 5Vac/Vdc, A (resistive load) Life, cycles or more Min. opening and 5V, ma (reference value) closing specifications Communica- Communication system Communication protocol RS-485 tion Network Multidrop, This device is provided with the slave station function. to units max. Data flow Synchronization method Half-duplex Start/stop synchronization Interface Transmission system Balance (differential) type Data line Communication lines Transmission speed Communication distance Protocol Bit serial transmit/receive lines 48, 96, 9, 84 bps 5m max. RS-485 (-wire type) Message characters Character configuration 9 to bits/character Data length Stop bit length Parity bit Loader Communication line -wire communica- Transmission speed Fixed at 9 bps tion Recommended cable Dedicated cable, m long 7 or 8 bits or bits Even parity, odd parity, or non-parity Current Number of inputs points transformer Detection function Control output is.: Detection of heater line break or overcurrent input Control output is OFF.: Detection of final control devices short-circuit Input object Number of current transformer windings: 8 turns QN6A (5.8mm-hole diameter) Optional QNA (mm-hole diameter) Optional Measurement current.4 to 5A range Indication accuracy ±5%FS± digit Indication range. to 7.A Indication resolution.a Output Selected from control output and control output, or event output, event output, and event output. Min. detection time Burnout detection: Min. control output time.s or more Final control device short-circuit detection: Min. control output OFF time.s or more 6

General Memory backup Semiconductor non-volatile memory specifications Power supply voltage AC power supply model: 85 to 64Vac, 5/6Hz±Hz Power consumption Insulation resistance Dielectric strength Power inrush current AC power supply model: Max. VA Between power supply terminal and secondary terminal, 5Vdc, MΩ or more AC power supply model: Between power supply terminal and secondary terminal, 5Vac for min. AC power supply model: A or less Operating conditions Ambient temperature to 5 C ( to 4 C for side-by-side mounting) Ambient humidity Vibration resistance Shock resistance to m/s to 9%RH (No condensation allowed) Mounting angle Reference plane ± to m/s ( to 6Hz for hrs. in each of X, Y, and Z directions) Transportation Ambient temperature - to +7 C conditions Ambient humidity to 95%RH (No condensation allowed) Package drop test Drop height, 6cm, ( corner, sides, 6 planes, free fall) Console and case Console: Polycarbonate material Case: Modified PPE Case color Light gray (DIC65) Conformed standards EN6-, EN66- Overvoltage category Category II (IEC664-4-4, IEC644-) Mounting Panel mounting (with dedicated mounting bracket) Weight SDC5: Approx. 5g (including dedicated mounting bracket) SDC6: Approx. g (including dedicated mounting bracket) Standard Part name Model Q'ty Optional parts Part name Model Q'ty accessories Mounting bracket 849654- (sold Mounting bracket 849654- separately) User s manual CP-UM-588E Current transformer QN6A (5.8mm-hole dia.) QN6A (mm-hole dia.) Hard cover 844695- (for SDC5) 844696- (for SDC6) Terminal cover 84469- (for SDC5) 84469- (for SDC6) Smart loader package SLP-C5J5 (common for SDC5 and SDC6) 7

Table Input Types and Ranges Input type C No. Sensor type Range Thermo- K - to + C - to + F couple K to C to F K to 8 C to 5 F 4 K. to 6. C to F 5 K. to 4. C to 7 F 6 K -. to +4. C - to +7 F 7 K -. to +. C - to +4 F 8 J to C to F 9 J. to 8. C to 5 F J. to 6. C to F J -. to +4. C - to +7 F E. to 8. C to 5 F E. to 6. C to F 4 T -. to +4. C - to +7 F 5 R to 6 C to F 6 S to 6 C to F 7 B to 8 C to F 8 N to C to F 9 PL II to C to F Wre5-6 to 4 C to 4 F Wre5-6 to C to 4 F Ni-NiMo to C to F PR4- to 9 C to 4 F 4 DIN U -. to +4. C - to +7 F 5 DIN L -. to +8. C -5 to +5 F 6 Golden iron chromel.k to 6. K. to 6. K Handling Precautions The accuracy is ±.%FS± digit, and ±.6%FS± digit for a negative area of the thermocouple. The accuracy varies according to the range. The accuracy of the No.7 (sensor type B) is ±4.%FS for a range of 6 C or less, ±.4%FS for 6 to 8 C. The accuracy of the No. (sensor type PR4-) is ±.5%FS for to of C, and ±.5%FS for to 8 C, ±.5%FS for 8 to of 9 C. The accuracy of the No.6 (sensor type golden iron chromel) is ±.5K. For ranges with a decimal point, tenths are displayed on the line underneath point. Input type C No. Sensor type Range RTD 4 Pt -. to +5. C - to +9 F 4 JPt -. to +5. C - to +9 F 4 Pt -. to +. C - to +4 F 44 JPt -. to +. C - to +4 F 45 Pt -. to +. C -5 to +5 F 46 JPt -. to +. C -5 to +5 F 47 Pt -. to +. C -5 to +4 F 48 JPt -. to +. C -5 to +4 F 49 Pt -. to +5. C -5 to + F 5 JPt -. to +5. C -5 to + F 5 Pt -5. to +. C -5 to +4 F 5 JPt -5. to +. C -5 to +4 F 5 Pt -5. to +. C -5 to + F 54 JPt -5. to +. C -5 to + F 55 Pt -6. to +4. C -6 to + F 56 JPt -6. to +4. C -6 to + F 57 Pt -4. to +6. C -4 to +4 F 58 JPt -4. to +6. C -4 to +4 F 59 Pt -. to +6. C - to +4 F 6 JPt -. to +6. C - to +4 F 6 Pt. to. C to F 6 JPt. to. C to F 6 Pt. to. C to 4 F 64 JPt. to. C to 4 F 65 Pt. to. C to 5 F 66 JPt. to. C to 5 F 67 Pt. to 5. C to 9 F 68 JPt. to 5. C to 9 F Input type C No. Sensor type Range Linear 8 to mv Scaling in the range of -999 to +9999 input 8 to +mv Decimal point position changeable 8 to mv 84 to V 86 to 5V 87 to 5V 88 to V 89 to ma 9 4 to ma 8

Model Selection Guide I II III IV V VI VII VIII Example: C5TRUA I II III IV V VI VII VIII Basic Mount- Control Power Option Option Additional model ing output input supply process- No. ing C5 C6 T Note. Can not be selected for DC model. Note. Current transformer is sold separately. Mask size 48mm x 96m Mask size 96mm x 96mm Panel mounting type Specifications Control output Control output R Relay contact output V Voltage pulse output (for SSR drive) VC Voltage pulse output (for SSR drive) Current output VV Voltage pulse output (for SSR drive) Voltage pulse output (for SSR drive) C Current output CC Current output Current output U A D (Note ) (Note ) Universal AC model ( to 4Vac) 5/6Hz DC model (4Vac/dc) (available soon) Event relay output: points Event relay output: points, Auxiliary output (current output) 4 Event relay output: points (independent contact), 5 Event relay output: points (independent contact), Auxiliary output (current output) (Note ) (Note ) Current transformer inputs: points, Digital inputs: 4 points Current transformer inputs: points, Digital inputs: 4 points, RS-485 Communication No additional processing D Y Inspection Certificate provided Complying with the traceability certification 9

Dimensions C5 48 SDC5 5 65 Mounting bracket (Accessory) Terminal screw M (Unit: mm) pv sp out 96 man ev ev ev ot ot 8 mode display enter para C6 96 5 65 Mounting bracket (Accessory) Terminal screw M man pv SDC6 ev ev 96 ev ot ot sp out 8 mode display para enter Handling Precautions To fasten this controller onto the panel, tighten a mounting bracket screws, and turn one more half turn when there is no play between the bracket and panel. Excessively tightening the screws may deform the controller case. Panel cutout diagram C5 C6 Stand-alone mounting min. Gang-mounting +.5 44 (48xN 4) +.5 min. Stand-alone mounting 9 +.5 Gang-mounting (96xN 4) +.5 min. 9 +.5 9 +.5 min. 9 +.5 9 +.5 Handling Precautions When three or more units are gang-mounted horizontally, the maximum allowable ambient temperature is 4 C. For water-proof installation, install the attached gasket and then mount the device as a stand-alone device.

< Part Names and Functions (5) pv sp out SDC5 man ev ev ev ot ot mode para display enter () () () (4) (6) (5) (9) () mode (8) (7) (8) (7) man ev ev ev ot ot pv sp out para display enter SDC6 (6) (9) () () Upper display: Displays values (present temperature, etc.) or setup items. () Lower display: Displays values (set temperature, etc.) and other parameter values. When the lower display shows the value, the "sp" lamp lights up. When the display shows the manipulated variable (), the "out" lamp lights up. () () Mode indicator man: Lights when MANUAL (manual mode). ev to ev: Lights when event relays are. ot, ot: Lights when the control output is. (4) Multi-status indicator: In the combination of the lighting condition and the lighting status as a group, the priority groups can be set. (5) [mode] key: The operation which has been set beforehand can be done by pushing the key for s or more. (6) [display] key: Used to change the display contents in the operation display mode. Display is returned from bank setup display to operation display. (7) <,, key: Used for incrementing numeric values and performing arithmetic shift operations. (8) [para] key: Switches the display. (9) [enter] keys: Used to set the setup values at the start of change and during the change. () Loader connector: Connects to a personal computer by using a dedicated cable supplied with the Smart Loader Package. < Connection of C5/6 Power supply Control outputs to 4Vac 4 5 Relay Relay Relay (independent contact) Current Transformer inputs Thermocouple RTD Current Voltage Event outputs 4 5 6 4 5 6 Inputs CT CT COM 7 8 9 inputs + C B A ma V + + 4 5 6 7 8 9 4 5 6 7 8 9 4 + 4 Voltage pulse 4 5 6 7 + + + 4 Current 4 5 + + Auxiliary output COM + DI 4 8 9 Digital input Communication DA DB SG 4 Voltage pulse Current/Voltage pulse Current Current Current RS-485

Precautions on the use of self-tuning function The final control devices must be powered up simultaneously with or prior to the instrument when the self-tuning function is to be used. Precautions on wiring. Isolation within instrument Solid line portions " " are isolated. Dotted line portions " " are not isolated. Power supply Control output input Control output Current Transformer input Auxiliary output Current Transformer input Loader communication Internal Digital input Circuit Event output (Note ) Digital input Event output (Note ) Digital input Event output Digital input 4 RS-485 Communication Availability of input and output is based on a model number. Note In case of independent contact, the part between the event output and the event output is isolated.. Preventive measures against noise of instrument power supply () Reduction of noise Even though the noise is small, the noise filter is used to eliminate the effect of the noise as much as possible. Instrument power supply to 4Vac Noise filter C5 C6 () When noise is excessive If a large amount of noise exists, appropriate isolation transformer and line filter are used to eliminate the effect of the noise. Instrument power supply to 4Vac Other circuit Insulation transformer (/V) (/V) Line filter Yamatake's model No. E844664- (Equivalent to ZAC5-U made by TDK) Grounding E GND 4. Installation environment noise sources and preventive measures Generally, the following may be the noise sources in the installation environment: Relay and contact, electromagnetic coil, solenoid valve, power supply line (particularly, Vac or more), motor commutator, phase angle control SCR, radio communication device, welding machine, high-voltage ignitor, etc. Preventive measures against fast rise noise Use of CR filter is effective to prevent fast rise noise. Recommended filter: Yamatake's model No. 844665- (Equivalent to 95M5 made by Matsuo Electric.) 4. Wiring precautions () After taking the noise preventive measures, do not bundle the primary and secondary power cables together or put both power cables in the same conduit or duct. () Keep the input/output and communication lines 5 cm or more away from the power lines and power supply lines having a voltage of Vac or more. Additionally, do not put these lines together in the same conduit or duct. 5. Inspection after wiring After the wiring work has been completed, always inspect and check the wiring status. Great care should be taken since incorrect wiring may cause the instrument to malfunction or severe personal injury. C5 C6 RESTRICTIS USE This product has been designed, developed and manufactured for general-purpose application in machinery and equipment. Accordingly, when used in the applications outlined below, special care should be taken to implement a fail-safe and/or redundant design concept as well as a periodic maintenance program. Safety devices for plant worker protection Start/stop control devices for transportation and material handling machines Aeronautical/aerospace machines Control devices for nuclear reactors Never use this product in applications where human safety may be put at risk. Specifications are subject to change without notice. Advanced Automation Company -- Kawana, Fujisawa Kanagawa 5-85 Japan URL: http://www.azbil.com Printed in Japan. (H) st Edition: Issued in Jan., 4 No part of this publication may be reproduced or duplicated without the prior written permission of Yamatake Corporation.