Risk Assessment of Mechanical Equipment:



Similar documents
ATEX 94/9/EC Directive Declaration of Conformity: Tips and FAQ s

INTERNATIONAL STANDARD

An Introduction to ATEX -

EXPLOSION SAFETY DOCUMENT FOR THE ATEX 137 DIRECTIVE NEW NAME FOR A FIRE AND EXPLOSION HAZARD ASSESSMENT?

Making sense of Intrinsic Safety and Intrinsically Safe Tools

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Hazardous Locations Training

ATEX GUIDELINES (FIRST EDITION)

ATEX Fans 08/02/2008. Data subject to change without prior notice

of a general nature only and is not intended to address the specific circumstances of any particular individual or entity;

99/92/EC (ATEX 137) USE

Safe and Efficient Hydraulic Systems Review of ISO 4413 Hydraulic Fluid Power General Rules and Safety Requirements for Systems and Their Components

Industrial trucks for use in potentially explosive areas - placing on the market in compliance with Directive 94/9/EC and EN

Controlling fire and explosion risks in the workplace

Equipment vs. Component

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

IGEM/UP/16 Communication 1756

Instructions for Safe Use

Hazardous location. Definitions

Electrical Classification

Understanding the Machinery Directive (2006/42/EC)

FLAMMABLE LIQUIDS COMPLIANCE NOTE

IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

On the Method of Ignition Hazard Assessment for Explosion Protected Non-Electrical Equipment

How To Protect An Explosion

The impact of the New EMC Directive 2004/108/EC

RISK MANAGEMENT IN , THIRD EDITION

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Supplying new machinery

The Committee on Hazardous Substances (AGS)

Fire and Explosion Protection for Stationary Extraction Plants

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service

WORKING IN ISOLATION PROCEDURE

Take care with oxygen Fire and explosion hazards in the use of oxygen

This leaflet provides information on

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

INTERNATIONAL STANDARD

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

COMAH Competent Authority

What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Safety Storage Cabinets

Wilkins Safety Group

Fire & Explosion Risks in Service Stations

IMPORTANT SAFETY NOTICE

WORKING IN CONFINED SPACES GUIDELINES

Contents. 1. Legal Requirement Responsibility of Related Parties What are Confined Spaces Hazards Identification 4

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

Hazardous Substance Class Definitions & Labels

CE Marking and Technical Standardisation

Guide to enclosures for potentially explosive atmospheres

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Combustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS

Breathe In... FRONT COVER. Fresh Air By Design

Jonathan Wilson. Sector Manager (Health & Safety)

HAZARDOUS AREA TECHNICAL GUIDE

CONSULTING Training Courses

Company Header POLLUTION INCIDENT RESPONSE MANAGEMENT PLAN. For [site name] [EPL number]

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Terminal Box. Specifications TNCN

Explosion proof enclosures

Site and Storage Conditions for Class 3.1 Flammable Liquids

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ICHEME SYMPOSIUM SERIES NO. 141

RUSSIAN FEDERATION AND CUSTOMS UNION GOST R Certification Programme INTRODUCTION MAIN OBJECTIVES OF CERTIFICATES TYPES OF CERTIFICATES

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

SEISMIC VELOCITY TRANSDUCER T1-40

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment

PBX Series Quick Fit Connector Bimetallic Steam Traps

HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?

Variable speed drives for synchronous and asynchronous motors

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Your essential guide to CE Marking

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

GEA Bock ATEX Compressors. Semi-hermetic Compressors in Explosion-risk Environments. engineering for a better world. GEA Refrigeration Technologies

SITE CONTRACTOR PROCEDURES

Technical Data. Dimensions

Pressure Vessels (Air Compressors) and LPG Tanks

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS

2CMC300001D0003 November Enclosed switches ATEX

Guidance for Stationary Refrigeration & Air-Conditioning

Installation and safety instructions for AC/DC built-in devices

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

WHMIS After GHS: Preparing for Change. Canadian Centre for Occupational Health and Safety

Risk Engineering Guideline

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

HOT WORK PERMIT PROCEDURES

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved

Accident/Incident Investigation & Reporting Procedure

A Code of Practice for Pressure Equipment in the Department of Physics

Transcription:

Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com

Contents Contents... 1 Overview... 1 Changes between EN1127-1:2007 and EN1127-1:2011... 2 The inclusion of Tightness of Equipment... 2 Equipment which is durably technically tight:... 2 Examples of equipment which is durably technically tight are:... 3 Preventing Explosions... 3 Reduce the risk... 4 How do we approach the Risk Assessment?... 5 (Source: EN 1127-1 4.1 p8/9)... 5 How is the Risk Assessment adopted for ATEX categories?... 6 Routes to compliance with your Non-Electrical equipment (Group II)... 6 Is EN1127-1 applicable to my mechanical equipment?... 8 Assemblies... 8 What ignition sources do we need to consider?... 9 How can Intertek help?... 10 Overview EN 1127-1 2011 Edition, Explosive atmospheres Explosion prevention and protection Part 1: Basic concepts and methodology, has been released and gives guidance in the area of explosion prevention and protection. Hazards from explosions are to be considered in accordance with this standard along side EN ISO 12100, which specifies basic terminology, principles and a methodology for achieving safety in the design of machinery. It specifies principles of risk assessment and risk reduction to help designers achieve safety in design. These principles are based on knowledge and experience of the design, use, incidents, accidents and risks associated with machinery. Procedures are described for identifying hazards and estimating and evaluating risks during relevant phases of the machine life cycle, and for the elimination of hazards or sufficient risk reduction. Guidance is given on the documentation and verification of the risk assessment and risk reduction process. As indicated in Section 1 of the Standard, understanding the application of EN 1127-1 will help designers and manufacturers in achieving explosion safety in the design of equipment, protective systems and components at all stages of its use. It is applicable to any equipment, protective systems and components intended to be used in potentially explosive atmospheres, under atmospheric conditions. www.intertek.com 1

Changes between EN1127-1:2007 and EN1127-1:2011 The risk assessment now includes reference to EN15198 Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres in addition to EN ISO 12100. With this change, the risk assessment aspect has been modified to include the frequency of occurrence of the potential ignition source and the flammable atmosphere. The potential ignition sources are classified according to the likelihood in the following manner: Sources of ignition which can occur continuously or frequently; Sources of ignition which can occur in rare situations; Sources of ignition which can occur in very rare situations. The inclusion of Tightness of Equipment The formation of a hazardous explosive atmosphere outside the equipment can be prevented or limited by means of the tightness of the equipment. Here, a differentiation is made between: equipment which is durably technically tight; technically tight equipment where the escape of flammable materials is due to operation. Equipment which is durably technically tight: a) In the case of equipment which is durably technically tight, no release is to be expected. b) Equipment is regarded as durably technically tight, if: 1. it is constructed such that it remains technically tight due to its design; or 2. its technical tightness is permanently ensured by means of maintenance and supervision. c) Equipment with a durably technically tight construction does not cause any hazardous areas in its surroundings while closed. www.intertek.com 2

Examples of equipment which is durably technically tight are: 1. welded equipment with: I. detachable components where the required detachable connections are rarely detached due to operation and are designed like the belowmentioned detachable pipework connections (exception: metallically sealing connections); II. detachable connections with pipeworks, fittings or blind covers where the required detachable connections are rarely detached and are designed like the below-mentioned detachable pipework connections; 2. shaft passages with double-acting axial seal ring (e.g. pumps, agitators); 3. canned motor pumps; 4. magnetically coupled seal-less pumps; Please refer to EN1127-1:2011 Annex B p35. Preventing Explosions EN 1127-1 page 5 specifically addresses explosion hazards that can occur from: a) materials processed or used by the equipment, protective systems and components; b) materials released by the equipment, protective systems and components; c) materials in the vicinity of the equipment, protective systems and components; d) materials of construction of the equipment, protective systems and components. The standard provides guidance and specifies methods for the identification and assessment of hazardous situations leading to explosion. By conducting a well defined risk assessment and applying risk reduction techniques as prescribed by the Standard, appropriate measures can be applied to achieve the higher levels of safety and explosion prevention. www.intertek.com 3

Reduce the risk A significant amount of cost in any product can be removed by ensuring safety and explosion prevention is designed into it right from the start. EN1127-1 provides for a common sense approach to ensure: a) Appropriate design (without using safeguarding). The prevention approach, which is covered in Clause 6; b) Safeguarding. The protection approach, which is covered in Clause 6; c) Information for use. Safe use and operation, which is covered in Clause 7; d) Any other preventive measures. This approach is not specified in this Standard. You should refer to EN ISO 12100:2010, Clause 6. It is also very important to note that EN1127-1 1 page5/6 clearly states; The preventive and protective measures described in EN 1127-1 will not provide the required level of safety unless the equipment, protective systems and components are operated within their intended use and are installed and maintained according to the relevant codes of practice or requirements. Since safety depends not only on equipment, protective systems and components but also on the material being handled and its use, this standard also includes aspects related to the intended use and foreseeable misuse, that is, the manufacturer should consider in which way and for which purpose the equipment, protective systems and components will be used and take this into account during their design and construction. This is the only way hazards inherent in equipment, protective systems and components can be reduced. This reiterates that safety is everyone s responsibility from the OEM to the installer and to the end user. www.intertek.com 4

How do we approach the Risk Assessment? (Source: EN 1127-1 4.1 p8/9) A risk assessment shall be carried out for each individual situation in accordance with EN ISO 12100 and/or EN 15198, unless other standards can be identified as being more appropriate to the situation: a) Identification of explosion hazards and determination of the likelihood of occurrence of a hazardous explosive atmosphere; b) Identification of ignition hazards and determination of the likelihood of occurrence of potential ignition sources; c) Estimation of the possible effects of an explosion in case of ignition; d) Evaluation of the risk and whether the intended level of protection has been achieved; e) Consideration of measures to reduce of the risks. A comprehensive approach should be taken, especially for complicated equipment, protective systems and components, plants comprising individual units and, above all, for extended plants. The risk assessment shall take into account the ignition and explosion hazard from: 1. The equipment, protective systems and components themselves; 2. The interaction between the equipment, protective systems and components and the substances being handled; 3. The particular industrial process performed in the equipment, protective systems and components; 4. The surroundings of the equipment, protective systems and components and possible interaction with neighbouring processes. www.intertek.com 5

How is the Risk Assessment adopted for ATEX categories? The ignition hazard assessment will identify sources of ignition; these are then dealt with either through compliance with the EN 13463 series of standards. Category 3 equipment, Zone 2/22 Assessment of potential ignition sources under normal operation and under certain operating conditions of the equipment. This is the main task and performed for all categories. Category 2 equipment, Zone 1/21 Assessment of potential ignition sources under expected malfunction. Category 1 equipment Zone0/20 Assessment of potential ignition sources under rare malfunction. Routes to compliance with your Non-Electrical equipment (Group II) Category 3 equipment, Zone 2/22 Internal Control of Production (Manufacturers Declaration) Category 2 equipment, Zone 1/21 Internal Control of Production & Communicate the Technical Documentation to a Notified Body Category 1 equipment, Zone0/20 EC Type Examination and Quality Assurance Notification All of above may be subjected to Unit Verification Certification. www.intertek.com 6

Classification of hazardous places (Source: Reference Directive 1999/92/EC) Hazardous places are classified in terms of zones on the basis of the frequency and duration of the occurrence of an explosive atmosphere. The extent of the measures to be taken in accordance with Annex II, Part A, is determined by this classification. Zone 0 A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is present continuously or for long periods or frequently. Zone 1 A place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally. Zone 2 A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. Zone 20 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently. Zone 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. Zone 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. www.intertek.com 7

Is EN1127-1 applicable to my mechanical equipment? (Source: Reference ATEX Guidelines 3.7.3) If non-electrical equipment has a potential ignition source, (in most cases this is due to moving parts able to create a potential ignition risk either from hot surfaces, or friction sparks) then EN1127-1 is applicable. Examples are: gears, fans, pumps, compressors, mixers, brakes. Mechanical equipment of this type usually has to be connected to a power source, such as an electric motor. Together placed on the market in this form, it might be an assembly (an assembly, formed by combining two or more pieces of equipment, together with components if necessary, has to be considered as a product falling under the scope of Directive 94/9/EC). Assemblies (Source: Reference ATEX Guidelines 3.7.5) An assembly consisting of different compliant pieces of equipment as defined by Directive 94/9/EC (ATEX Certified) which were previously placed on the market by different manufacturers has to conform with the Directive, including being subject to proper conformity assessment, CE-marking, etc. A manufacturer may choose to supply an assembly - e.g. a pump and motor - with one declaration of conformity for the assembly as a whole. In this case further clarification is required as to the obligation of the assembler where only ATEX CE compliant products are used. Here it is clear that the assembler needs to undertake an ignition risk assessment (EN1127-1:2011) to ensure that the nature of the incorporation and assembly has not altered the explosion characteristics of the products with respect to the Essential Health and Safety Requirements. If there are additional ignition hazards, a further conformity assessment of the assembly regarding these additional risks is necessary. This might be the case, for example, if a assembler of mechanical equipment needs to connect different pieces of ATEX electrical equipment together as part of the assembly. Once the assembler has successfully undertaken such an assessment and no additional ignition risk has been identified, the general agreement is that the assembler produces a technical file for the assembly. Affixes the CE and Ex marking to the assembly, indicating intended use. www.intertek.com 8

Signs the EC Declaration of Conformity covering the whole of the assembly indicating the technical specifications/ standards applied (for example, for electrical inter-connection) and provide instructions for safe use. The assembler therefore takes complete responsibility for the assembly. What ignition sources do we need to consider? In accordance with the EN1127-1 standard all key ignition sources likely to occur in operation of the equipment are: Hot surfaces Flames and hot gases (including hot particles) Mechanically generated sparks Electrical apparatus Stray electric currents, cathodic corrosion protection Static electricity Lightning Radio frequency (RF) electromagnetic waves from 104 Hz to 3 x 1011 Hz Electromagnetic waves from 3 x 1011 Hz to 3. x 1015 Hz Ionizing radiation Ultrasonics Adiabatic compression and shock waves Exothermic reactions, including self-ignition of dusts www.intertek.com 9

How can Intertek help? Intertek offers market leading services from our knowledgeable team of hazardous locations testing engineers located in facilities around the world. Our experienced, global teams provide comprehensive services required in today s competitive market. Our service levels range from EC Type Examination (required only for Category 1 & M1) to storing your Technical Documentation (minimum requirement for Category 3 equipment). Although in some cases non-electrical equipment does not require Notified Body involvement, Intertek can offer manufacturers of Category 2 and Category 3 non-electrical equipment a service level appropriate to their needs, as a minimum we can provide; Ignition Hazard Assessment Technical File Storage Technical File Gap Analysis Testing to applicable standards Certification Body Services To understand our full capabilities and services for ATEX compliance reducing your costs and improving speed to market, please contact us. For more information on specific testing and certification information, please contact Intertek at 1-800-WORLDLAB, email icenter@intertek.com, or visit our website at www.intertek-hazloc.com. This publication is copyright Intertek and may not be reproduced or transmitted in any form in whole or in part without the prior written permission of Intertek. While due care has been taken during the preparation of this document, Intertek cannot be held responsible for the accuracy of the information herein or for any consequence arising from it. Clients are encouraged to seek Intertek s current advice on their specific needs before acting upon any of the content. www.intertek.com 10